USER’S GUIDE
A
L
E
R
T
S
Y
S
T
E
M
M
A
I
N
T
E
N
A
N
C
E
PATENT PENDING
H, J, AND HJ
GH
THIS PRODUCT IS TO BE
INSTALLED AND SERVICED
BY A TRAINED DOOR
SYSTEMS TECHNICIAN
ONLY.
Operators are shipped in C2
operating mode.
Visit www.liftmaster.com to locate
a professional installing dealer in
your area.
T AND APT
GT
2 YEAR WARRANTY
Serial # Box
Installation Date
CONTACT INFORMATION
THIS OPERATOR FEATURES THE ENHANCED
The Maintenance Alert System™ allows the installer
to set an internal Maintenance Cycle Counter. The
Logic 4 operator incorporates a self-diagnostic
feature built into the (MAS) Maintenance Alert
System LED. An LED on the 3-button station will
signal when the set number of cycles/months is
reached or when the operator requires immediate
service.
NOT FOR RESIDENTIAL USE
315MHz
Radio Receiver
Built on Board
www.liftmaster.com
INTRODUCTION
Congratulations on purchasing a quality, LiftMaster Logic 4 Commercial Door Operator. Your new operator is capable of operating up to
12 cycles per hour or 50 cycles per day. It is equipped with a built in radio receiver that is compatible with our existing 315 MHz product
line as well as a Timer-to-Close (TTC) feature that can be enabled when LiftMaster Commercial Protector System® is installed and aligned
properly.
BASIC PROGRAMMING
INTRODUCTION TO PROGRAMMING
Many programmable functions require that a LiftMaster Entrapment Protection (LMEP) device be installed in order to function.
Refer to the Entrapment Protection section.
LOGIC BOARD OVERVIEW
DATA
Single Phase &
Three Phase Jumper
Maintenance Alert
System Button for
Programming
Open Button
Close Button
Stop Button
Control Wiring
Terminal Block
Optional Auxiliary
Card Receptacles
Motor Direction Jumper
Maximum Run
Timer Button
Radio Learn Button
Mid Stop Learn Button
Timer-To-Close
Learn Button
SLOT 1
SLOT 2
REV
STD
DIRECTION
MOTOR
OLS
MID
SLS
CLS
MRT MID TTC
RADIO
D1
C2
123
TTS
E2
B2
RELAY A
RELAY B
FSTS
DIAG
OPTN
PROG
1-PHASE
TIMER
ENABLE
3-PHASE
24VAC
POWER
24VAC
TIMER
DEFEAT
COMMON
MAS
LMEP:
EDGE:
OPEN
CLOSE
STOP
COMMON
SBC
Selector Dial
(used for programming
and selecting wiring type)
Main Motor Control Harness Connection
LOGIC BOARD LED OVERVIEW
NOTE: Before programming the logic board, set the operator’s
open and close limits. LEDs on the logic board are provided to
assist setting the limits. As each limit is activated the
corresponding LED will light up. The abbreviations are Open Limit
Switch (OLS), Close Limit Switch (CLS) and Sensing Limit Switch
(SLS). Refer to page 19 for limit switch adjustment instructions.
When power is applied to the operator, the following LED’s will
illuminate: STOP, CLOSE, OPEN, LMEP, 24Vac, RADIO, DATA,
TIMER ENABLE, OLS MID, SLS, CLS, and MAS. Once the power
up process is completed (approximately 2-3 seconds) only the
appropriate LED’s will continue to be lit (i.e., STOP, 24Vdc, limit
LED(s) if limit(s) is activated).
NOTE: When the power up process is over, the MAS LED will
blink a code indicating the version of firmware. If the selector dial
is in the DIAG, OPTN, or PROG position, the MAS will not provide
this code. After the code has been provided the MAS LED will go
out.
LOGIC BOARD PUSH BUTTONS (OPEN, CLOSE, STOP)
Open, Close and Stop buttons are mounted directly on the logic
board. Thus, making it easy to program as well as have door
control at the electrical box.
Either the stop control or a jumper MUST be wired between
terminals 4 and 5 for the on board push buttons to function.
2
OPTN
PROG
DIAG
FSTS
TS
T
E2
D1
C2
B2
BASIC PROGRAMMING
DETERMINE AND SET WIRING TYPE
Read the descriptions of the different wiring types to determine which setting will be correct for each application. Once the wiring type
is determined, set the selector dial accordingly.
LIFTMASTER MONITORED ENTRAPMENT PROTECTION (LMEP)
DEVICE IS REQUIRED
A LiftMaster Entrapment Protection (LMEP) device is required for
the following wiring types.
B2 Momentary contact to open, close and stop, plus wiring for
sensing device to reverse and auxiliary devices to open and
close with open override. Programmable mid stop available
with this wiring type. Compatible with 3-Button Station,
1-Button Station, 1 and 3-Button Remote Control.
TS (TIMER SECURE)
This mode will attempt to close the door from any position
except when fully closed, or when a safety input is present.
The stop button will not disable the Timer-To-Close at any
position. To disable the Timer-To-Close in this mode,
installation of a defeat switch is required (see wiring
diagram).
Momentary contact to open, close, and stop with open
override and Timer-To-Close. Every device that causes door
to open, including a reversing device, activates the TimerTo-Close. Auxiliary controls can be connected to open input
to activate the Timer-To-Close. If the timer has been
activated, the open button and radio control can recycle the
timer. The Timer-To-Close will function from the
programmable mid stop with this wiring type. Compatible
with 3-Button Station, 1-Button Station and 1 and 3-Button
Remote Control.
NOTE: A Programmable “Car Dealer Mode” available.
T Momentary contact to open, close, and stop, with open
override and Timer-To-Close. Every device that causes the
door to open, except any safety edge input device, activates
the Timer-To-Close. Auxiliary controls can be connected to
open input to activate the Timer-To-Close. If the Timer-ToClose has been activated, the open button and radio control
can recycle the timer. The stop button will deactivate the
timer until the next command input. The Timer-To-Close will
function from the programmable mid stop with this wiring
type. Compatible with 3-Button Station,1-Button Station
and 1 and 3-Button Remote Control.
NOTE: Programmable “Car Dealer Mode” available.
FSTS Momentary button contact for open, close and stop
programming. User set mid stop. User set Timer-To-Close.
The single button station opens the door to the full open
limit bypassing the mid stop and activates the Timer-ToClose, putting the operator in TS mode until the door
reaches the down limit, or is stopped in travel. At which
time the operator enters the B2 mode.
Compatible with 3-Button Station, 1-Button Station, 1 and
3-Button Remote Control. A 1-Button remote control in
FSTS mode will open only with the Timer-To-Close,
bypassing a programmed mid stop. The Timer-To-Close will
reset and reverse when closing.
LIFTMASTER MONITORED ENTRAPMENT PROTECTION (LMEP)
DEVICE IS RECOMMENDED
A LiftMaster Entrapment Protection (LMEP) device is
recommended for the following wiring types.
C2 Momentary contact to open and stop with constant pressure
to close, open override plus wiring for sensing device to
reverse. Programmable mid stop available with this wiring
type. Compatible with 3-Button Station and 1-Button
Station.
E2 Momentary contact to open with override and constant
pressure to close. Release of close button will cause door to
reverse (roll-back feature) plus wiring for sensing device to
reverse. Compatible with 3-Button Station.
D1 Constant pressure to open and close with wiring for sensing
device to stop. Compatible with 2 or 3-Button Station.
SELECTOR DIAL
IMPORTANT NOTES:
1. External interlocks may be used with all functional modes.
2. Auxiliary devices are any devices that have only dry contacts.
Examples: photocell, loop detector, pneumatic or electrical
treadles, radio controls, one button stations, pull cords, etc.
3. Open override means that the door may be reversed while
closing by activating an opening device without the need to use
the stop button first.
4. When the door is in a stopped position other than fully closed,
and a safety input is activated (LMEP or EDGE), the Restricted
Close (RC) feature will allow a close command when the close
button is pressed and held. The operator will begin closing after
5 seconds. If the close button is released the door will stop.
When in E2 mode, the door will move to the fully open position.
3
RADIO
SLS
MRT MID TTC
TIM
ENA
123
TTS
E2
CLS
MID
MOTOR
DIRECTION
HASE
TTC
LMEP:
EDGE:
OPEN
CLOSE
STOP
COMMON
TIMER
ENABLE
3
FSTS
DIAG
OPTN
RADIO
SLS
MRT MID TTC
TIM
ENA
123
TTS
E2
CLS
MID
MOTOR
DIRECTION
ASE
BASIC PROGRAMMING
RADIO
SLS
MRT MID TTC
TIM
ENA
123
TTS
E2
CLS
MID
MOTOR
DIRECTION
ASE
RADIO
SLS
MRT MID TTC
TIM
ENA
123
TTS
E2
CLS
MID
MOTOR
DIRECTION
HASE
To prevent possible SEVERE INJURY or DEATH:
• Install a LiftMaster Monitored Entrapment Protection (LMEP)
device.
• NEVER permit children to operate or play with door control
push buttons or remote controls.
REMOTE CONTROLS
Built in 3-channel, 315 MHz radio receiver allows you to add as many as 23 Security✚® remotes or dip switch remote controls.
NOTE: The following programming requires a LiftMaster Monitored Entrapment Protection (LMEP) device.
SINGLE BUTTON REMOTE CONTROL
1
Press and release the
RADIO button (RADIO
LED will light).
Press and hold the remote control button until the
2
RADIO LED fl ashes rapidly, then release remote
control button. The RADIO LED will then remain
on solid after releasing the button. Repeat to add
additional remote control(s).
• Activate door ONLY when it can be seen clearly, is properly
adjusted and there are no obstructions to door travel.
• ALWAYS keep door in sight until completely closed. NEVER
permit anyone to cross the path of closing door.
3
Press and release
the RADIO button
to complete the
programming. The
programming mode
is exited if no activity
is performed within
30 seconds.
3-BUTTON REMOTE CONTROL TO OPERATE AS A WIRELESS 3-BUTTON CONTROL STATION
NOTE: The feature will use 3 of the 23 memory channels in the operator.
1
Press and release
the RADIO button
on the logic board
(the Radio LED
will light).
Repeat steps 1 through 3 to program additional buttons.
23
Press and release
the desired button
on the logic board
(OPEN, CLOSE or
STOP). The Radio
LED will fl ash and
then stay on solid.
Press and hold the desired button of the remote
control until Radio LED fl ashes rapidly, then
release.
TO ERASE ALL REMOTE CONTROLS
1
Press and hold the
RADIO button on the
logic board until the
RADIO LED fl ashes
rapidly (approximately
5 seconds).
All remote controls
will be erased.
4