APPLICATION REQUIREMENTS:
This wiring modification is available to models H and J Logic
operators.
FUNCTIONS:
This modification stops the operator from running when extra
tension is sensed on the door from the mechanical door lock,
obstruction or extensive binding.
OPERATION:
When unit senses load running open from close limit, Lock
Sensor will stop operator. Press close button and run until it
shuts off (to unlock door when load removed).
NOTE:
Refer to addendum for wiring and locksensor adjustment,
for all other installation instructions refer to owner’s manual
provided with operator.
ADDENDUM
LOCK SENSOR (LOGIC 3)
Models: DH, DJ, and DHJ
FINE ADJUSTMENT
• To increase opening force, tighten wing nut.
• To decrease opening force, loosen wing nut.
COURSE ADJUSTMENT (IF REQUIRED)
1.Release spring pressure on pivot arm.
2.Loosen but do not remove two mounting screws.
3.Fully tension final reduction chain and rotate lock sensor until
switch is in activation mode.
4.Tighten mounting screws (2) to secure lock sensor position.
5.Repeat fine adjustments.
LOCK SENSOR ADJUSTMENT
Moving parts my cause SERIOUS INJURY. Keep hands CLEAR
of sprockets, chains, and other moving parts when making
adjustments.
© 2006, The Chamberlain Group, Inc.
01-31376B All Rights Reserved
Final Reduction Chain
Chain Idler Sprocket
must engage top side
of reduction chain.
Mounting Screws
Lock Sensor Assembly
Lock Sensor Switch
(held to normally closed).
To adjust opening force
tighten or loosen adjustment
on wing nut accordingly.