Lift-Master 65 7202 User Manual

MANUAL HOIST FOR CENTER
MOUNT J and DJ OPERATORS
657202
DESCRIPTION
Disconnect Chain Retaining Bracket Sprocket, 50B35 X 1" Bore, 1/4 KW, (2) S.S. Hoist Chain, 25' Chain 106 Pitches with Master Link #50 Sash Chain & Key Ring Assembly* Manual Hoist Housing Assembly Key, 1/4 Sq. X 1-1/2" Long *Shipped when door height is over 15'.
QTY
1 1 1 1 1 1 1
APPLICATION
This modification is available for center mounted operators models J and DJ.
FUNCTIONS
Provides hand chain operation for manually opening/closing doors with center mounted operator. A reduced drive disconnect chain hoist is connected to the door shaft with sprocket and chain drive. Since the door shaft rotates when the operator runs, the chain wheel is engaged or disengaged by a floor level chain.
CHAIN HOIST INSTALLATION
1. Disconnect power to operator.
2. Install the chain hoist assembly to the wall next to the output shaft. This can be mounted to either side of the output shaft by just moving the 50B12 sprocket to either side.
3. Install the provided 50B35 sprocket onto the output shaft. Align the sprocket with the sprocket on the chain hoist assembly and secure with the 1/4" key provided.
4. Connect the two sprockets together using the #50 chain provided.
NOTE:
The Chain Hoist connects to the door shaft. The chain hoist hand chain does not move until the engagement chain is pulled.
ELECTRIC INTERLOCK SWITCH
1. If an operator is used, be sure to wire this switch into its
control circuit so that the operator cannot electrically engage when the chain hoist is activated.
2. If the operator is set to accept an external interlock, remove the
factory provided jumper between terminals in the electrical box. Terminals 4 and 5 in mechanical operators, and terminals 2 and 3 in logic operators. If other external interlock devices are present connect interlocks in series.
3. If there is no provision for an electric interlock, wire the switch
in series with the stop button.
4. Reconnect power to operator.
PACKING LIST
INSTALLATION
© 2005, The Chamberlain Group, Inc.
01-12197D All Rights Reserved Printed in Mexico
To prevent possible SERIOUS INJURY or DEATH from electrocution, disconnect electric power to operator BEFORE installing.
ALL electrical connections MUST be made by a qualified individual.
WARNING
Sprocket, #50B35 X 1" Bore
Sprocket, #50B12 (Not shown)
Electric Interlock Switch (Must be connected if operator is used.)
Chain Hoist Assembly (Shown on left side, can be mounted on either side.)
Engagement Sash Chain (If operator is present, it will be necessary to release the operator in order to activate the hoist. Otherwise, the operator will hold the door in place.)
Disconnect Chain Retaining Bracket
Door Shaft
Hand Chain
Loading...