Life Fitness Models 9100 / 9500HR / 9700HR Treadmills
How To… Remove and Replace the Wax Bag
Tools required: Phillips screwdriver, Side Cutters or Utility Knife
Step 1
Turn the power OFF at the ON/OFF switch and then unplug the unit from the electrical outlet.
Step 2
Remove the two SCREWS securing the WAX BAG ACCESS PANEL located on the user left side of the unit. Remove
the WAX BAG ACCESS PANEL and set it aside.
FOR A FIRST TIME INSTALLATION, SKIP TO STEP 7.
Step 3
Engage the HOSE CLAMP onto the WAX BAG HOSE.
Step 4
Slide the WAX BAG HOSE off the BARBED NOZZLE on the WAX PUMP INLET HOSE.
Step 5
Remove the two WINGNUTS located just inside the access hole.
Step 6
Lift the WAX BAG from the two WINGNUT STUDS. Slide the WAX BAG out of its PROTECTIVE LINER. Discard the
used WAX BAG.
Wax Bag
Protective Liner
Stud
Wax Bag
Wax Bag
Access Panel
Wax Bag
Access Panel
Wax Bag
Hose
Hose
Clamp
Wax Pump
Inlet Hose
Step 7
Verify that the WAX BAG PROTECTIVE LINER is open and ready to receive the WAX BAG. Remove the new WAX
BAG from its packaging and carefully insert the WAX BAG into the access hole as shown with the WAX BAG HOSE
facing the rear of the unit.
Step 8
For first time installations, remove the two WINGNUTS located just inside the access hole.
Step 9
Align the mounting holes located in the WAX BAG FLANGE with the two WINGNUT STUDS. Secure the WAX BAG
with the two WINGNUTS.
CAUTION: BE CAREFUL NOT TO RIP OR OTHERWISE DAMAGE THE WAX BAG ON THE WINGNUT STUDS
AND WINGNUTS WHEN INSERTING THE WAX BAG INTO THE FRAME.
Continued
Life Fitness Models 9100 / 9500HR / 9700HR Treadmills
How To… Remove and Replace the Wax Bag (Continued)
Step 10
Slide the HOSE CLAMP over the end of the WAX BAG OUTLET HOSE. Position the
HOSE CLAMP approximately three inches from the end of the WAX BAG HOSE and
engage the HOSE CLAMP onto the WAX BAG HOSE.
Step 11
Cut ½” off the end of the WAX BAG HOSE and slide the WAX BAG HOSE onto the
BARBED NOZZLE on the WAX PUMP INLET HOSE. Be sure to fully seat the WAX
BAG HOSE. Release the HOSE CLAMP.
Step 12
Replace the WAX BAG ACCESS PANEL and secure with the two WAX BAG ACCESS PANEL SCREWS.
FIRST TIME INSTALLATION IS NOW COMPLETE.
IF WAX BAG IS BEING REPLACED, CONTINUE THROUGH STEP 21.
Step 13
Reset the WAX FILL STATISTICS as follows.
Step 14
Press and hold the PAUSE KEY. While holding the PAUSE KEY press the CLEAR KEY twice. Continue to hold the
PAUSE KEY until the DISPLAY reads “ SERVICE MENU.”
Step 15
Press any UP ARROW KEY until you see “MAINTENANCE” in the DISPLAY. Then press ENTER. The DISPLAY
will begin to scroll automatically through available options.
Step 16
When the DISPLAY reads “REFILL WAXER SYSTEM”, press the ENTER KEY. The DISPLAY will read “REPAIR
LOGGED.”
Step 17
Wax replacement is now complete.
Step 18
To verify that the wax refill has been completed correctly, press the CLEAR KEY once to return to the “SERVICE
MENU.”
Step 19
Using any of the UP ARROW KEYS, scroll until “INFORMATION” is displayed. Then press ENTER.
Step 20
Press any of the UP ARROW KEYS until “WAX MOTOR INFO” appears in the DISPLAY. Press ENTER and verify
that the DISPLAY reads “100/100 FULL.”
Step 21
Press the CLEAR KEY three times to exit diagnostic.
WAX BAG REPLACEMENT IS NOW COMPLETE.
MO51-00K58-A005