Liebert UPStation GXT User Manual

Page 1
POWER PROTECTION
UPStation GXT™ 6kVA Maintenance Bypass
USER MANUAL
Transformerless
with Configurable
Output Distribution
Page 2
Page 3
TABLE OF CONTENTS
IMPORTANT SAFETY INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
GLOSSARY OF SYMBOLS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
GENERAL DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
SYSTEM DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Standard Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
MAJOR COMPONENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
BYPASS SWITCH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
C
ONFIGURABLE OUTPUT DISTRIBUTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
15 Amp Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
20 Amp Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
30 Amp Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Other Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
CABLE INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
WIRING PREPARATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
P
OWER CABLE INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
WALL-MOUNT DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
DIAGRAM FOR ATTACHING UNIT TO WALL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
HARDWIRE OUTPUT OPTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
OPERATING PROCEDURES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Start-Up and Initialization. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
ON MAINTENANCE BYPASS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
O
N UPS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Shutting Down the UPS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
ON UPS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
O
N MAINTENANCE BYPASS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Transferring System From UPS to Maintenance Bypass Operation . . . . . . . . . . . . . . . 12
Transferring System From Maintenance Bypass to UPS Operation . . . . . . . . . . . . . . . 12
S
PECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
i
Page 4
Page 5

IMPORTANT SAFETY INSTRUCTIONS

SAVE THESE INSTRUCTIONS
This manual contains important instructions that should be closely followed during installation and maintenance of this UPStation GXT 6kVA Maintenance Bypass.
This product is designed for commercial / industrial use only. This product is not intended for use with life support and other designated “critical” devices. Maximum load must not exceed that shown on the Maintenance Bypass Cabinet rating label.
WARNING
!
LETHAL VOLTAGES MAY BE PRESENT WITHIN THIS UNIT EVEN WHEN IT IS APPARENTLY NOT OPERATING. OBSERVE ALL CAUTIONS AND WARNINGS IN THIS MANUAL. FAILURE TO DO SO MAY RESULT IN SERIOUS INJURY OR DEATH. NEVER WORK ALONE.
The UPStation GXT 6 kVA Maintenance Bypass is designed for use on properly grounded (earthed) 208/240VAC 60 Hz supply, for installation by qualified personnel. This UPS equipment is intended to be installed by a qualified / certified electrician who must review and approve customer supplied wiring, circuit breakers, intended loads and verify correct input, output and grounded (earth) connections to ensure compliance with technical standards and national and local electrical codes. Installation instructions and warning notices are in the Cable Installation section of this manual beginning on page 6.
CAUTION
!
To reduce the risks of fire, connect only to a circuit provided with maximum branch circuit overcurrent protection of 40A in accordance with applicable national and local electrical codes.
Install the bypass equipment in a clean environment, free of conductive contaminants, moisture, flammable liquids, gases, and corrosive substances.
1
Page 6

GLOSSARY OF SYMBOLS

Risk of electrical shock
Indicates Warning or Caution followed by important instructions
i
Requests the user to consult the manual
Equipment grounding conductor
On
Off
2
Page 7

GENERAL DESCRIPTION

Congratulations on your purchase of Liebert's UPStation GXT 6 kVA Maintenance Bypass. As with every Liebert product, we stand behind our quality. If you have any questions concerning this Maintenance Bypass, please feel free to contact your local sales representative, or call the appropriate Technical Support number listed on the back of this manual.
To ensure proper installation and operation of this unit, please read this manual thoroughly.
While installation must be completed by a qualified / certified electrician, general operation may be performed without special training.

SYSTEM DESCRIPTION

The Liebert UPStation GXT 6 kVA Maintenance Bypass is intended for use with the UPStation GXT 6 kVA UPS. Typical applications include supporting workstations, servers, network, telecom or other sensitive electronic equipment.
The UPStation GXT 6 kVA Maintenance Bypass was designed to provide maximum system availability to business-critical equipment. The bypass allows for transfer of connected loads to an alternate power path, allowing full isolation of the UPS. After connected loads are switched to alternate power and the UPS is isolated, the UPS can be turned off and removed from service with no interruption of power to connected loads.
The Configurable Output Distribution was designed to provide maximum flexibility to business-critical equipment.
Various output receptacle options are available from 15 A to 30 A. Hardwire options are also available with a branch rated circuit breaker.

Features

• Supports up to 30A loads
• Compact design
• Highly configurable
• Multiple power path indicators
• High-speed, break-before-make transfer switch

Standard Components

• Provisions for hardwire output
• Power indicator lamps
• Branch rated circuit breakers
• Easily accessible terminal blocks

Options

• Field-installable output distribution kits
NOTE
The 120V loads need to be balanced on the UPS output. To do this, when connecting 120V equipment to the Maintenance Bypass (MB), start at one end of the MB and fill in toward the other end.
3
Page 8
Maintenance Bypass component layout
UPS input power present (amber)
UPS input switch (SW2)
Output breaker (CB1)
Bypass availability indicator (amber)
Bypass switch (SW1)
UPS output availability indicator (green)
Configurable Output Distribution
TOP VIEW
4312
GND3
GND1
4312312312 122
GND2
Utility
input
TB1
INSIDE VIEW— RECEPTACLE PLATES AND END PLATE REMOVED
UPS
input
TB2
UPS
output
TB3
Hardwire output terminal block (TB4)
4
Page 9

MAJOR COMPONENTS

The following is a general description of each component and its functions. Please review this section carefully, as it will give you a better understanding as to how the UPStation GXT 6 kVA Maintenance Bypass operates.

BYPASS SWITCH

The Bypass Switch allows easy and rapid transfer of connected loads between the UPS and bypass source.

CONFIGURABLE OUTPUT DISTRIBUTION

Several receptacle and hardwire options are available as user-selectable output distribution. These are factory-configured when ordered and also allow for field upgrades. Common receptacle and hardwire options include:

15 Amp Options

5-15R2
L5-15R2
6-15R2-208
6-15R2-240
L6-15R2-208
L6-15R2-240
15A, 120V, 1 Pole Breaker for 1/2" & 3/4" conduit
15A, 208V, 2 Pole Breaker for 1/2" & 3/4" conduit
15A, 240V, 2 Pole Breaker for 1/2" & 3/4" conduit

20 Amp Options

5-20R2 (T-Slot)
L5-20R
L6-20R-208
L6-20R-240
L14-20R-240
20A, 120V, 1 Pole Breaker for 1/2" & 3/4" conduit
20A, 208V, 2 Pole Breaker for 1/2" & 3/4" conduit
20A, 240V, 2 Pole Breaker for 1/2" & 3/4" conduit

30 Amp Options

L5-30R
L6-30R-208
L6-30R-240
L14-30R-240
30A, 120V, 1 Pole Breaker for 1/2" & 3/4" conduit
30A, 208V, 2 Pole Breaker for 1/2" & 3/4" conduit
30A, 240V, 2 Pole Breaker for 1/2" & 3/4" conduit

Other Options

Single Position Blanking Plate
Hardwire Options
Single Position Plate with 1/2", 3/4" and 1" conduit knockouts
Double Position Plate with 1-3/4" and 2" conduit knockouts
5
Page 10

CABLE INSTALLATION

WIRING PREPARATION

!
CAUTION
Please read this section thoroughly before attempting to install wiring to this unit.
Be sure that the unit is not connected to any AC mains power source or UPS before installing any wiring to this unit. This should be installed by a qualified/certified electrician.
For access to terminal blocks, see diagrams on page 4.
NOTE
The 120V loads need to be balanced on the UPS output. To do this, when connecting 120V equipment to the Maintenance Bypass, start at one end of the output modules and fill in toward the other end. Load balancing must be performed with the UPStation GXT6000T - 208X and 240X. It is not required on the GXT6000T-208 because the unit has no 120V output.

POWER CABLE INSTALLATION

Refer to the chart below when selecting cables:
Power Cable and Protection Ratings
208V 240V
Max Input Current 30 A 30 A Input Protection 40 A 40 A Max Output Current 30 A 30 A
2
(6 AWG)
2
(14 AWG)
Terminal Block Details
NOTE
Customer must supply power cables between Maintenance Bypass and UPS, utility and load. (GMB12 models are supplied with an attached input power cord complete with L14-30 plug.)
Max: 16 mm
Min: 2.5 mm Torque: 2 Nm (16 in/lb)
6
Page 11
Connecting Maintenance Bypass to UPStation GXT6000T - 208
208
VAC
Output
12 3 4
TB4
Utility
input
L1 L2
GND3
GND2
MAINTENANCE BYPASS
GND1
Utility
TB1
2132132134
UPS input
TB2
UPS output
TB3
NOTE
When using the Maintenance Bypass with an UPStation GXT6000T-208, a jumper (included with the accessory kit) must be connected to the TB3 (UPS output) terminal block on the Maintenance Bypass between TB3-1 and TB3-2, as shown.
NOTE
GMB12 models are supplied with an attached input power cord complete with L14-30 plug.
L1 L2 L1 L2
Input Output Ext. battery
GXT6000T - 208
+-
7
Page 12

Connecting Maintenance Bypass to UPStation GXT6000T - 208X

120V
208V
120V
Output TB4
12 3 4
GND3
MAINTENANCE BYPASS
GND2
Utility
input
NOTE
GMB12 models are supplied with an attached input power cord complete with L14-30 plug.
L2 L1
N
GND1
Utility
TB1
213 213 2134
UPS input
TB2
GEC
L1 L2 N L1
Input Ext. battery
GXT6000T - 208X
UPSoutput
TB3
L2 L2A
Output
+-
8
Page 13

Connecting Maintenance Bypass to UPStation GXT6000T - 240X

120V
GND3
240V
Output TB4
12 3 4
MAINTENANCE BYPASS
GND1
120V
GND2
Utility
L2
input
L1
N
NOTE
GMB12 models are supplied with an attached input power cord complete with L14-30 plug.
Utility
TB1
213 213 2134
UPS input
TB2
L1 L2 N L1
Input
GXT6000T - 240X
UPSoutput
TB3
GEC
L2
Output
9
+-
Ext. battery
Page 14

WALL-MOUNT DIAGRAM

DIAGRAM FOR ATTACHING UNIT TO WALL

Use the following diagram, which shows the location and measurements of factory-cut mounting slots, when preparing to attach the GXT Maintenance Bypass to a wall. Liebert recommends using 1/4-20 mounting screws. Rubber pads are supplied for placing the Maintenance Bypass on the floor.
178mm
7.00"
514mm
20.25"
C
L
10
Page 15

HARDWIRE OUTPUT OPTION

This product is intended to be installed by a qualified electrician only.
1. COMPLETELY REMOVE ALL POWER FROM THE FRAME. If the Maintenance Bypass is connected to the UPS, disconnect external battery supply.
2. Remove the end cover plate to access the terminal block (see Accessing terminal block below).
3. Without disconnecting from the terminal block, unscrew and pull out the hardwire plate(s).
4. Route all wires from the hardwire plate(s) to the terminal block.
5. Connect the GROUND wire to the grounding bar strip (GND1).

Accessing terminal block

6. Connect the remaining wires in accordance with the wiring diagram (located inside the base enclosure).
NOTE
When wiring 120 V loads, LINE must be alternated between TB4-1 and TB4-3 to balance the 120V load. Connect all neutral wires to TB4-4.
7. Replace the receptacle plates and the end cover plate, using care to not damage the wires.
11
Page 16

OPERATING PROCEDURES

START-UP AND INITIALIZATION

Follow these steps in order to start up the GXT 6kVA UPS while connected to the Maintenance Bypass.

ON MAINTENANCE BYPASS

1. Set the Maintenance Bypass switch (SW1) to UPS position.
2. Close (position I) UPS Input switch (SW2).
3. Close (position I) Output Circuit breaker (CB1).

ON UPS

1. Close (position I) battery circuit breaker.
2. Close (position I) input circuit breaker.
3. Close (position I) output circuit breaker.
4. After the start-up sequence the UPS will automatically default to its internal bypass. The bypass LED will be lit.
5. Press UPS On/Alarm/Battery Test button for at least one second to turn the UPS on. The UPS ON LED will be lit.
6. Connected equipment may now be switched on.

SHUTTING DOWN THE UPS

Use the following procedure to power down the system.

ON UPS

1. Press Output OFF/Bypass button for at least 1 second, twice, within 4 seconds.
2. Open (position O) UPS output, input and battery circuit breakers.

ON MAINTENANCE BYPASS

1. Open (position O) output breaker (CB1).
2. Open (position O) UPS input switch (SW2).

TRANSFERRING SYSTEM FROM UPS TO MAINTENANCE BYPASS OPERATION

1. On UPS verify that Bypass LED is lit, if not, press UPS OFF/Bypass button for at least one second.
2. On Maintenance Bypass verify that the Bypass lamp is illuminated.
3. Rotate Bypass switch SW1 to the Bypass position.
4. Set UPS Input switch SW2 to the Off position (position O). This will remove power from UPS input.
CAUTION
!
The connected load is now powered by the bypass source and is not protected.

TRANSFERRING SYSTEM FROM MAINTENANCE BYPASS TO UPS OPERATION

1. On Maintenance Bypass close (position I) UPS Input switch (SW2).
2. On UPS close (position I) input, output and battery circuit breakers.
3. After the start-up sequence the UPS will automatically default to its internal bypass. The bypass LED will be lit.
4. Press UPS ON/Alarm/Battery Test button for at least one second to turn the UPS on. The UPS ON LED will be lit.
5. On Maintenance Bypass verify that UPS Output LED is illuminated.
6. Rotate Bypass switch SW1 to the UPS position.
12
Page 17

SPECIFICATIONS

Typical Transfer Time (to or from maintenance bypass)
Input Voltage Nominal 208VAC or 240VAC
Total Current 30A max.
Operating Ambient Temperature 0° to +40° C
Storage Ambient Temperature -20° to +60° C
Dimensions, W x D x H, in (mm) 8.2 x 21.0 x 6.2 (209 x 534 x 158)
Chassis Weight (no receptacles) 10 lbs.
Distribution Module Weights (each) 2 lbs.
Connections to UPS Hardwire Terminal Blocks
Humidity 0 to 95%, non-condensing
Agency/Standards UL 1778, c-UL
< 6 milliseconds
13
Page 18
Page 19
Page 20
POWER PROTECTION
UPStation GXT 6kVA Maintenance Bypass
USER MANUAL
The Company Behind the Products
With over a million installations around the globe, Liebert is the world leader in computer protection systems. Since its founding in 1965, Liebert has developed a complete range of support and protection systems for sensitive electronics:
Environmental systems—close-control air conditioning from 1 to 60 tons
Power conditioning and UPS with power ranges from 300 VA to more than 1000 kVA
Integrated systems that provide both environmental and power protection in a single, flexible package
Monitoring and control—from systems of any size or location, on-site or remote
Service and support through more than 100 service centers around the world and a 24/7 Customer Response Center
While every precaution has been taken to ensure the accuracy and completeness of this literature, Liebert Corporation assumes no responsibility and disclaims all liability for damages resulting from use of this information or for any errors or omissions.
© 2002 Liebert Corporation All rights reserved throughout the world. Specifications subject to change without notice.
® Liebert and the Liebert logo are registered trademarks of Liebert Corporation. All names referred to are trademarks or registered trademarks of their respective owners.
SL-23447 (8/02) Rev. 2
Technical Support/ Service
Web Site
www.liebert.com
Monitoring
800-222-5877
monitoring@liebert.com
Outside the US: 614-841-6755
Single-Phase UPS
800-222-5877
upstech@liebert.com
Outside the US: 614-841-6755
Three-Phase UPS
800-543-2378
powertech@liebert.com
Environmental Systems
800-543-2778
Outside the United States
614-888-0246
Locations
United States
1050 Dearborn Drive
P.O. Box 29186
Columbus, OH 43229
Italy
Via Leonardo Da Vinci 8
Zona Industriale Tognana
35028 Piove Di Sacco (PD)
+39 049 9719 111
Fax: +39 049 5841 257
Asia
23F, Allied Kajima Bldg.
138 Gloucester Road
Wanchai
Hong Kong
+852 2 572 2201
Fax: +852 2 831 0114
Loading...