The Vertiv™ Liebert® GXT5 UPS is an
online double conversion UPS
solution which oers premium power
outage protection and continuous
power conditioning in a compact and
flexible rack/tower form factor.
The Liebert GXT5 single-phase UPS
operates with high power eiciency,
making it ideally suited to protect critical
infrastructure in both centralized and edge
network applications.
Now available in higher capacity ratings of
16 and 20 kVA the GXT5 UPS allows for
highly reliable single UPS installations
minimizing required rack space and
supporting more IT equipment loads.
Scalable runtime options with matching
external battery cabinets oer additional
flexibility when extended uninterrupted
power is required. Plus, the Liebert GXT5
provides battery health status and
replacement date prediction for intelligent
battery health management.
The UPS system is easy to deploy and
maintain due to its user-friendly LCD
interface and remote management
capabilities supported by the Vertiv
RDU101 communications card which
makes the Liebert GXT5 compatible with
Vertiv infrastructure management solutions
such as LIFE™ Services, environmental
sensors, Trellis™ Power Insight, and more.
With market leading eiciency and unity
power factor operation, the Liebert GXT5
will meet your critical application needs.
And you can rest assured that your
business is protected with this Vertiv
solution that includes a standard, two-year
advanced exchange product warranty.
What's in the box
yUPS
yTower Stand
yUSB Cable
yQuick Start Guide
ySafety Manual
yPower Insight Management
Software (free download from
Vertiv.com)
Liebert GXT5 Features
Leading UPS Technology
y High output power factor up to 1.0
y Full-color graphic LCD
with gravity sensing orientation
y External battery cabinets with
auto-detection
y Parallel or redundant
operation capability
y Battery health status and
replacement date prediction
y Remote management, update,
and configuration capabilities
y Optimized thermal management
and variable speed fan for peak
eiciency and noise reduction
Eicient and Green Product
y High eiciency in online mode
y Energy Star® 2.0 certified
y Even higher eiciency (up to 98%) in
Active ECO mode
y Compliance with Restriction of
Hazardous Substances (RoHS)
directive and the Registration,
Evaluation, Authorization and
Restriction of Chemicals
(REACH) regulation
Solutions Wide
y Compact rack/tower design
y Broad range of services and
extended warranty
y Easy to install, configure and operate
y Vertiv RDU101 network
communications card with
advanced features
y Compatibility with SN series
environmental sensors
y Integrated dry-contacts with
selectable definition
y Free Trellis™ Power Insight
management software
y Serial port for out-of-band
management with Avocent®
serial consoles
y Automatic internal bypass and
external maintenance bypass options
2
Vertiv™ Liebert® GXT5 Features
A
B
LCD
COLOR
LCD
COLOR
LCD
COLOR
B
LCD
COLOR
B
LCD
COLOR
LCD
COLOR
ECO
A
B
LCD
COLOR
B
2+1
High power factor (1.0)
1.0
Compact rack/
tower design
Space-saving UPS
provides rack space
optimization and
flexible installation.
PF
More usable power enables
more connected loads saving
space and costs.
Eiciency (up to 95%)
in online mode
Energy Star 2.0 certification. Higher
eiciency means an optimized energy
management and lower heat
dissipation, for energy savings and
improved reliability.
Parallel/redundant
operation capability
For 10, 16 or 20 kVA
models, configurations
up to 2+1 redundancy
support maximum
availability and enables
growth as load demand
increases.
2+1
ECO
Eiciency (up to 98%)
in Active ECO mode
Superior protection with
maximum eiciency.
Product warranty
Comprehensive coverage
B
through a standard two-year
advanced exchange warranty.
Colored graphic
LCD with gravity
sensitive orientation
User-friendly interface
provides insight to
UPS status for easy
installation, configuration
and operation.
Integrated Battery
With self-test and
detection capability
Battery Cabinets
with auto-detection
Be confident the UPS is set
up correctly to report
available runtime when used
with external battery cabinets.
COLOR
LCD
3
Vertiv™ Liebert® GXT5 | 5 - 20 kVA UPS
How You Benefit from the Vertiv™ Liebert® GXT5 UPS
Designed for high availability
y Higher power factor (1.0) ensures the connection of more loads and IT equipment
y Available rack mount maintenance bypass solution eliminates the need to
power down connected equipment (16-20) kVA
y Device can be swapped during operation without powering down connected equipment thanks to manual
bypass pod integrated in the device (removable connetion box), (5-10) kVA
y Optional output distribution POD for flexibility of connected equipment needs
y Hot-swappable, user-replaceable battery modules minimize downtime
y LIFE™ Services helps to enhance uptime, as well as operational eiciency with
continuous remote monitoring, expert analysis, and proactive response
y Automatic programmable battery self-test
User-friendly installation and operation
y Easy-to-read, gravity-sensing graphical color display
y Intuitive user interface for local configuration and management
y Support for the Vertiv suite of remote management tools
(Trellis™ Power Insight, RDU101 network interface card, and serial connectivity support)
y Auto-detection of external battery cabinets enables faster deployment and accurate runtime information
y Remote UPS firmware upgrade capability ensures the UPS has the latest features and enhancements
Longer service life and runtime of the batteries
y Extended runtimes provided by the addition of external battery cabinets
y Improved battery care by temperature-compensated battery charging
y Intelligent battery health management ensures a longer service life
(optimized battery maintenance and replacement when needed)
Optimized energy and capacity management
y Active ECO operating mode with up to 98% eiciency
y Eiciency in online double conversion mode up to 95%
y Energy Star 2.0 certified
Seamless connectivity
y Four onboard, user-definable dry contact I/O for integration of support management systems
y Supports SNMP, web, and environmental sensors with the optional RDU101 communications card
y Serial connection for integration of Avocent® ACS product or direct serial management and
control of the UPS
4
Vertiv™ LIFE™ Services Remote Diagnostic and Preventive Monitoring
Vertiv's service program is designed to
ensure that your critical power protection
system is maintained in an optimum state
of readiness at all times.
The Vertiv LIFE™ remote diagnostic and
preventive monitoring service provides
early warning of UPS conditions and out
of tolerances. This allows eective
proactive maintenance,fast incident
response and remote trouble shooting,
giving customers complete security and
peace of mind.
With Vertiv LIFE Services you
will benefit from:
Uptime Assurance
Constant monitoring of UPS parameters,
thus maximizing the availability of your
critical infrastructure.
First Time Fix Rate
Pro-active monitoring and data measuring
ensure that when our customer engineers
are dispatched on-site, they arrive
prepared for first time resolution.
Proactive Analysis
From Vertiv LIFE Services centers, our
experts proactively analyze the data and
trends of your equipment, to recommend
actions to ensure their best performance.
Minimized Total Cost of Ownership
of Your Equipment
The continuous monitoring of all relevant
parameters in turn maximizes unit
performance, reduces on-site
maintenance and extends the life of your
equipment.
Fast Incident Response
Vertiv LIFE Services allow for immediate
definition of the best course of action, as
a result of the regular communication
between your Liebert GXT5 system and
our Vertiv LIFE Services centers.
Reporting
You will receive a comprehensive report
detailing the working order of your equip
mentand its operational performance.
Ratings (VA/ W) 5000 VA / 5000 W6000 VA / 6000 W8000 VA / 8000 W10,000 VA / 10,000 W
Dimensions, inches (mm)
Unit W x D X H
16.9×24.8×8.5
(430×630×394)
Weight, pounds (kg)
Unit156 (70.8)298 (135.2)298 (135.2)298 (135.2)
Input AC Parameters
Operating Frequency,
Nominal
Voltage Range230 VAC230 VAC230 VAC230 VAC
Input WiringHardwireHardwire
50 or 60Hz
(Factory D efault is 50)
Output AC Parameters
Output Receptacles
Factory-default
VAC Frequency
Waveform (On Battery)SinewaveSinewaveSinewaveSinewave
Utility (AC) Mode
Overload
>150% for Minimum 200mS; 125 - 150% for 60
seconds; 105-125% 5 Minutes; ≤105 % Continuous
Hardwire
2 (C19), 6 (C13)
230 VAC
50Hz or 60Hz, Nominal
>150% for Minimum 200mS; 125 - 150% for 60
seconds; 105-125% 5 Minutes; ≤105 % Continuous
Battery
16.9×24.8×8.5
(430×630×394)
50 or 60Hz
(Factory D efault is 50)
Hardwire
2 (C19), 6 (C13)
230 VAC
50Hz or 60Hz, Nominal
16.9×24.8×8.5
(430×630×394)
50 or 60Hz
(Factory D efault is 50)
Hardwire
(common or split bypass)
Hardwire
4 (C19), 4(C13)
230 VAC
50Hz or 60Hz, Nominal
>150% for Minimum 200mS; 125 - 150% for 60
seconds; 105-125% 5 Minutes; ≤105 % Continuous
16.9×24.8×8.5
(430×630×394)
50 or 60 Hz
(factory- default is 50 Hz)
Hardwire
(common or split bypass)
Hardwire
4 (C19), 4(C13)
230 VAC
50Hz or 60Hz, Nominal
>150% for Minimum 200mS; 125 - 150% for 60
seconds; 105-125% 5 Minutes; ≤105 % Continuous
Typ eValve-regulated, non-spillable, lead acidValve-regulated, non-spillable, lead acidValve-regulated, non-spillable, lead acidValve-regulated, non-spillable, lead acid
Backup Tim e
(100% Load )
Backup Tim e
(50% Load)
+1 External Battery
Cabinet (100% Load)
+1 External Battery
Cabinet (5 0% Load)
7 Minutes5.5 Minutes3.5 Minutes2 Minutes
18.5 Minutes14.5 Minutes9.5 Minutes7 Minutes
19 Minutes14.5 Minutes9.5 Minutes7 Minutes
48 Minutes38.5 Minutes26 Minutes19 Minutes
Environmental Requirements
Operating Temperature,
°F (°C)
Storage Temperature,
°F (°C )
Relative Humidity
Operating Elevation
Audible Noi se
+32 to +104 (0 to 40) (no derating)+32 to +104 (0 to 40) (no derating)+32 to +104 (0 to 40) (no derating)+32 to +104 (0 to 40) (no derating)
+5 to +122 (-15 to 50)+5 to +122 (-15 to 50)+5 to +122 (-15 to 50)+5 to +122 (-15 to 50)
0% to 95%,
non-condensing
Up to 10,000 ft (3,000 m) at 77°F (25°C)
without derating
<55 dBA, at 1 meter from the rear
<50 dBA, at 1 meter from the front or sides
Up to 10,000 ft (3,000 m) at 77°F (25°C)
<50 dBA, at 1 meter from the front or sides
0% to 95%,
non-condensing
without derating
<55 dBA, at 1 meter from the rear
0% to 95%,
non-condensing
Up to 10,000 ft (3,000 m) at 77°F (25°C)
without derating
<55 dBA, at 1 meter from the rear
<50 dBA, at 1 meter from the front or sides
0% to 95%,
non-condensing
Up to 10,000 ft (3,000 m) at 77°F (25°C)
without derating
<55 dBA, at 1 meter from the rear
<50 dBA, at 1 meter from the front or sides
Agency
Surge Immunity
TransportationISTA Procedure 1EISTA Procedure 1EISTA Procedure 1EISTA Procedure 1E
Std. 2 year; Opt. 1 and 3 year extensionStd. 2 year; Opt. 1 and 3 year extensionStd. 2 year; Opt. 1 and 3 year extensionStd. 2 year; Opt. 1 and 3 year extension
Std. 2 year; Opt. 1 and 3 year extensionStd. 2 year; Opt. 1 and 3 year extension
7
Vertiv™ Liebert® GXT5 | 5 - 20 kVA UPS
Accessories
Vertiv™ VR Rack
Supports a wide variety of
equipment and gives you
the flexibility you need with
easy installation
Vertiv™ Geist™ rPDU
Reliably distributes power to
the rack, supporting
dynamic data center
operations and DCIM
Vertiv™ SwitchAir
Prevents overheating of
network switches by
directing cool air to switch
intakes, keeping hot
exhaust air out
Vertiv™ ACS Console
Enables integrated remote
monitoring, out-of-band
management, and IoT
connectivity
Vertiv™ KVM Switch
Enables single-point access
for switching between
multiple computers
Racks and enclosures: Support a
wide variety of equipment with the
Vertiv™ VR Rack including servers,
storage, switches, routers, PDUs,
UPS units, console port servers,
and KVM switches.
Rails and mounting hardware:
Install equipment with a four-post
rail kit and hardware for mounting
in a 19- or 23-inch rack or choose a
two-post telecom rack for front-
or mid-chassis, wall, or Zero U
configuration.
Rack mount PDUs: For basic or
intelligent power distribution that
helps prevent overloaded circuits in
the data center, choose from products
such as upgradable PDUs, inline power
meters, transfer switches, and
monitoring sensors.
Extended battery modules:
Enable scalable runtime for support
during extended power outage
situations by adding reliable power
and protection to new or existing
deployments.
Environmental sensor: Maintain
knowledge of remote environments
Vertiv™ Rack Cooling
Provides energy-eicient
cooling close to the
IT equipment and UPS units
with temperature, humidity and
leak detection, or monitor available
dry-contact sensors for security
access control or smoke detection.
Vertiv™ Liebert® GXT5
Helps protect missioncritical equipment from all
power disturbances due to
blackouts, brownouts, sags,
surges or noise interference
8
Available Accessories for the Vertiv™ Liebert® GXT5 UPS
External battery cabinets and replacement battery kits