Compact UPS Systems For High Power Network Rack Applications
AC Power
For Business-Critical Continuity™
Page 2
Liebert GXT3, 5kVA-10kVA UPS Systems:
Big Protection, Small Package
Today’s converged networks require increased availability and reliability.
This has created a need for higher density power protection systems that
adapt to mixed load voltages and plug types, while remaining easy to
install and maintain.
New IT technologies, such as VoIP and PoE, have greatly increased power
demands. Unfortunately, as these requirements have risen, the amount of
space available for your protected equipment and related power support
systems has not.
Liebert IntelliSlot Webcard provides SNMP and
web-based management
The Liebert Solution
Liebert GXT3 UPS meets the need
for higher power capacities in small
spaces. This true on-line double
conversion UPS system is available in
5kVA – 10kVA models, and features
integrated maintenance bypass, as
well as optional extended battery
runtime. Add support — Emerson
Network Power Service — and it all
equals greater power assurance and
reliability.
Designed for use in either rack or
tower congurations, all units offer
the smallest available solutions for
these power capacities — the 5 & 6kVA
model at 120/208V output in 4U
size, or the 8 & 10kVA unit 120/208V
output in a 6U package. A 6kVA 208V
output 5U size model is also available.
To help meet the need for choosing a
single supplier for global applications,
220V, 230V and 240V 50/60 Hz
models are offered with CE and C-tick
markings.
Dual Voltages For Multiple
Applications
Simultaneous output voltages of
240/120, 208/120, 230/115, 220/110,
or 200/100 VAC provide the exibility
to adapt to multiple load requirements
without the need to add additional
transformers that take up extra space
and add weight. Input power factor
correction to 0.99 reduces current
harmonics and their heating effects.
Communications For Power
Monitoring And Control
Liebert GXT3 UPS offers a variety
of communications options to
provide the monitoring and control
capabilities demanded by today’s
network computing systems.
Operation can be monitored using:
Liebert IntelliSlot Web Card provides
SNMP and web-based monitoring
and control of your UPS.
Liebert MultiLink™ Automated
System Shutdown Software
Liebert Nform™ Monitoring System
Liebert Universal Monitor And
Remote Power Monitor Panels
Third-Party Monitoring Systems
On Line UPS
Surge
Suppression
Dynamic
Bypass
Power Factor
Correction/Rectifier
Charger
Battery
Inverter
OutputUtility
2
Page 3
UPS operation and display panel can rotate
90 degrees, which provides upright
viewing for users.
Liebert GXT3 UPS Includes These
Outstanding Features:
Flexibility:
Rack/tower configuration. The
versatile unit installs in either
conguration, and includes a rotating
LED display panel that conforms to the
desired orientation.
Automatic frequency detection.
Detects and matches line input
frequencies of either 60 or 50 Hz.
User replaceable hot-swappable
internal batteries. Provide four
minutes of runtime at full load.
port. Utilizes Liebert IntelliSlot Web
Card to provide SNMP and web-based
monitoring and control of your UPS.
Includes Windows-based
configuration program. Allows
various operating parameters to be
adjusted and tests to be scheduled.
Built-in USB communications for use
with Liebert MultiLink™ Automated
Shutdown Software. Allows you to
monitor communication between the
UPS and a server, and ensures a
graceful unattended shutdown.
Built-in closure signals. Provides
notication to monitoring systems of
operating conditions including: on
battery, low battery, battery mode
shutdown and any mode shutdown.
Emergency Power Off (EPO).
Terminal connections for a normally
open or normally closed emergency
power off switch.
Higher Availability:
Wider input voltage window
minimizes battery use. Features a
wide input voltage window that allows
the UPS to support the critical load
without having to transfer to batter y,
extending system availability for when
battery back-up is truly needed.
Internal automatic and manual
bypass. Assures continuity of power
to critical loads during system
maintenance or in case of internal
fault.
Self-diagnostics. Automatically tests
unit electronics and batteries.
Designed to simplify maintenance and
troubleshooting.
Lowest Total Cost Of Ownership:
Standard two-year replacement
warranty. No-hassle warranty
provides paid shipping both ways.
Optional one-year and three year
extensions available.
Uses less rack space. Leaves more
room for network equipment.
For longer service life. Shields
batteries from heat generating
electronic components, enhancing
battery life.
Battery cutoff voltage Automatically
adjusts based on load, extending
battery life by preventing overdischarge of batteries.
Liebert Power Assurance
Package Offers A Worry-Free
UPS Solution For
Your Network
Liebert GXT3 5-10kVA UPS
systems may be purchased as part
of the Liebert Power Assurance
Package. While today’s smaller,
rack-based UPS systems offer
relatively trouble-free operation,
the growing criticality of the
systems they support has
increased the cost of downtime.
As a result, the need to maintain
these smaller UPS systems is
increasingly important.
This all-inclusive package offers
you complete peace-of-mind for
ve years including:
UPS — A compact, high quality
on-line Liebert GXT3 UPS (5, 6, 8
or 10kVA).
Start-up — On-site system
start-up by a certied Emerson
Network Power Customer
Engineer, scheduled anytime, 24
x 7. This includes removal and
disposal of your existing UPS.
Preventive maintenance —
One preventive maintenance
visit completed in year 3 by a
certied Emerson Network Power
Customer Engineer includes 100%
Parts Coverage — even internal
batteries.
Full parts coverage — Your
on-line Liebert UPS benets
from 100% parts coverage for
ve years, including all internal
batteries.
On-site service — Should you
experience a problem, we will
dispatch a certied Emerson
Network Power Customer
Engineer to repair or replace
your equipment — with 4-hour
response guaranteed.
3
Page 4
5 Or 6kVA Of True On-Line Power
In A Compact 4U Package
Liebert GXT3 5 & 6kVA models
are true on-line UPS systems
that provide internal batteries
and dual output voltage. They
are an ideal fit for applications
where the power requirements
are demanding — but rack space
is limited — delivering 5kVA
(4kW) or 6kVA (4.8kW) of power
in a single 4U size cabinet. This
cabinet size is well suited for
installations such as network
closets or small data centers.
Adaptable Design
For installation exibility, the
Liebert GXT3 5 & 6kVA models
allow you to choose from several
different wiring congurations
made possible by the use of
removable power distribution
boxes that simply plug into the
rear of the UPS. The standard
box provides terminal blocks
for hardwired input and output
connections. An optional
hardwire version that includes
a maintenance bypass is also
available.
When the ease of plug-and-play
power connections is desired,
optional versions of the power
distribution box convert Liebert
GXT3 5 & 6kVA units to a cordtype input with receptacles for
output distribution, and also offers
maintenance bypass capability that
allows hot-swapping of the entire
UPS. The UPS has as adaptable
dual inverter design, capable of
providing simultaneous output
voltages of 240/120, 208/120,
230/115, 220/110, or 200/100 and
an output power factor of 0.8.
PD2-HDWR ships standard
with the unit and is hardwire
input/output
PD2-HDWR-MBS is an optional
hardwire input/output POD
with maintenance bypass
5 & 6 kVA Model shown in rack mount position
6 kVA Model shown in tower position with
optional battery cabinet
Pluggable input/output
PODs available with
maintenance bypass
4
Page 5
8kVA And 10kVA Of Power
In Just 6U Of Space
The internal battery packs are
hot-swappable, and user repleaceable.
The unit also supports up to four external
battery cabinets for extended run time.
This Liebert GXT3 8 & 10kVA
units offer a flexible solution
for protecting rack-mount
equipment, including VoIP and
PoE. Especially designed for use
with the new generation of high
power switches, these compact
UPS systems pack 8kVA (7.2kW)
or 10kVA (9kW) of power into
a 6U rack/tower package with
flexible output voltage and
optional output distribution.
The UPS includes built-in, userreplaceable batteries for up to
four minutes of runtime at full
load.
8 & 10 kVA Model shown in rack mount position
10 k VA Model shown in tower position with
optional battery cabinet
UPS is hardwire input/output
with maintenance bypass and
includes no POD standard.
Optional PODs available
Adaptable Design
The UPS has a dual inverter
design, capable of providing
simultaneous output voltages
of 240/120, 208/120, 230/115,
220/110, or 200/100 and an
output power factor of 0.9. The
new 6U cabinet is the smallest for
208/120 selectable voltage in the
8-10kVA size. The unit features
integrated internal manual and
automatic maintenance bypass,
power module, battery modules,
auto detection of extended battery
cabinets and optional plug-andplay distribution plates.
The standard 8 & 10kVA models
include terminal blocks for
hardwired connections of both
input and output. Optional power
distribution modules are available
to add output receptacles to the
rear panel of the unit.
Hot-Swappable Operation
Liebert GXT3 8 & 10kVA units
feature three bays for one power
module and two battery modules.
The chassis contains a bypass
switch that allows all modules to be
removed without powering down
the connected load.
5
Page 6
Product specications
UPS specifications—5, 6, 8 and 10 kVA models
Model NumberGXT3-5000RT208GXT3-6000RT208GXT3-8000RT208GXT3-10000RT208
Model Rating4000W/5000VA4800W/6000VA7200W/8000VA9000W/10000VA
Dimensions, Rack Mount, W x D x H Unit in. (mm)16.9 x 26.1 x 6.8 (430 x 662 x 173)16.9 x 26.5 x 10.3 (430 x 672 x 261)
Weight Unit, lb (kg)56.2 (25.5)78.3 (35.5)
Input AC Parameters
Nominal Operating Frequency50 or 60Hz (Factory Default is 60Hz)
Factory Default VAC 120/208VAC
Factory Default L1-N, L2-N VAC120 VAC nominal
Input Frequency w/o Battery Operation40 - 70 Hz
Input Power ConnectionHardwire Terminal Block 3W + G (L-L-N-G)
L1-N, L2-N Maximum Allowable VAC150VAC
Output AC Parameters
Factory Default VAC120/208V AC
Factory Default L1-N, L2-N VAC120VAC nominal
User Configurable L1-N, L2-N VAC100/110/115/120/127VAC, ±2%
Overload Rating
105% to 130% 1 Minute
131% to 150%10 seconds
151% to 200%1 second
>200% (impact load)At least 5 cycles
Environmental
Operating Temp, °F (°C)32 to 104 (0 to 40)
Storage Temp, °F (°C)5 to 122 (-15 to 50)
Audible NoiseLess than 55dBA at 3.2ft. (1m) rear; less than 50dBA at 3.2ft. (1m) front and sides
Operating ElevationUp to 10,000 ft. (3000m) at 104°F (40°C) without derating
Relative Humidity0% to 95%, non-condensing
Agency
SafetyUL 1778, c-UL Listed
RFI/EMIFCC Part 15, Subpart B, Class A, FCC Class A
Surge ImmunityIEEE/ANSI C62.41 Category A & B
TransportationISTA Procedure 1A
Internal battery specifications
Model NumberGXT3-144BATKITGXT3-288RTBKIT
Used with UPS ModelGXT3-5000RT208 / GXT3-6000RT208GXT3-8000RT208 / GXT3-10000RT208
Dimensions, W x D x H, Unit in (mm)8.1 x 19.3 x 2.8 (206 x 490 x 70)8.1 x 19.7 x 5.3 (207 x 500 x 135)
Weight, Unit lb (kg)75.8 (34.4)71.2 (32.3)
Battery Parameters
Typ eValve-regulated, non-spillable, lead acid
Kit Quantity x Battery Quantity x V x Rating2 x 6 x 12V x 9.0 AH2 x 12 x 12V x 9.0 AH
Battery Mfr / Part #Yuasa / REW 45-12
Recharge Time3 hours to 90% capacity after full discharge into 100% load
EnvironmentalOperating Temp, Storage Temp, Operating Elevation, and Relative Humidity: Same as UPS
6
Page 7
External battery cabinet specifications
Model NumberGXT3-144VBATTGXT3-240VBATTULGXT3-288RTBATT
Used w/UPS ModelGXT3-5000 & GXT3-6000RT208GXT3-6000RTL630GXT3-8000 & GXT3 10000RT208
Dimensions, W x D x H,
Unit (with bezel) in. (mm)
Weight, Unit lb (kg)99.9 (45.3)94.8 (43)29.8 (13.5)
Battery Parameters
Typ eValve-regulated, non-spillable, lead acid
Kit Quantity x Battery Quantity x Rating2 x 6 x 12V x 9.0 AH2 x 10 x 12V x 9.0 AH2 x 12 x 12V x 9.0 AH
Battery Mfr., Part #Yuasa / REW 45-12
EnvironmentalOperating Temp, Storage Temp, Operating Elevation, and Relative Humidity: Same as UPS
16.9 x 26.1 x 3.3
(430 x 662 x 85)
16.9 x 22.6 x 5.1
(430 x 574 x 130)
16.9 x 26.5 x 6.8
(430 x 672 x 173)
Power distribution box specifications: GXT3-5000RT208, GXT3-6000RT208 and GXT3-6000RTL630
Emerson Network Power, a business of Emerson (NYSE:EMR), delivers software, hardware and
services that maximize availability, capacity and efficiency for data centers, healthcare and
industrial facilities. A trusted industry leader in smart infrastructure technologies, Emerson
Network Power provides innovative data center infrastructure management solutions that
bridge the gap between IT and facility management and deliver efficiency and uncompromised
availability regardless of capacity demands. Our solutions are supported globally by local
Emerson Network Power service technicians. Learn more about Emerson Network Power
products and services at www.EmersonNetworkPower.com
Emerson Network Power.
The global leader in enabling Business-Critical Continuity
AC Power
Connectivity
DC Power
Embedded Computing
Embedded Power
Monitoring
™
.
Outside Plant
Power Switching & Controls
Precision Cooling
Emerson Network Power
Liebert Corporation
World Headquarters
1050 Dearborn Drive
P.O. Box 29186
Columbus, Ohio 43229
United States Of America
800 877 9222 Phone (U.S. & Canada Only)
614 888 0246 Phone (Outside U.S.)
614 841 6022 FAX
Emerson Network Power
European Headquarters
Via Leonardo Da Vinci 8
Zona Industriale Tognana
35028 Piove Di Sacco (PD)
Italy
39 049 9719 111 Phone
39 049 5841 257 FAX
Emerson Network Power Asia Pacific
29/F, The Orient Square Building
F. Ortigas Jr. Road, Ortigas Center
Pasig City 1605
Philippines
+63 2 687 6615
+63 2 730 9572 FAX
liebert.com
24 x 7 Tech Support
800 222 5877 Phone
614 841 6755 (outside U.S.)
While every precaution has been taken to ensure accuracy and
completeness in this literature, Liebert Corporation assumes no
responsibility, and disclaims all liability for damages resulting
from use of this information or for any errors or omissions.