LG UU30W INSTALLATION INSTRUCTIONS

www.lg.com
INSTALLATION MANUAL
AIR CONDITIONER
P/NO : MFL67855411
Please read this installation manual completely before installing the product. Installation work must be performed in accordance with the national wiring standards by authorized personnel only. Please retain this installation manual for future reference after reading it thoroughly.
[
Representative] LG Electronics Inc. EU Representative : LG Electronics European Shared
Service Center B.V. Krijgsman 1, 1186 DM Amstelveen, The Netherlands
[Manufacturer] LG Electronics Inc. Changwon 2nd factory 84, Wanam-ro, Seongsan-
gu, Changwon-si, Gyeongsangnam-do, KOREA
For more information, Refer to the CD or LG Web site (www.lg.com).
Standard inverter Original instruction
ENGLISH
ITALIANO
ESPAÑOL
FRANÇAIS DEUTSCH
ΕΛΛΗΝΙΚΆ
ČEŠTINA
NEDERLANDS
POLSKI
LIMBA ROMÂNĂ
Single A Air Conditioner Installation Manual
CONTENTS
Safety Precautions ..............................................................................................3
Installation of Outdoor Unit................................................................................7
Wiring Connection.............................................................................................11
Connecting Pipes ..............................................................................................14
Leakage test and Evacuation ...........................................................................18
Test running .......................................................................................................20
Function..............................................................................................................22
Self-diagnosis Function....................................................................................23
Installation Guide at the Seaside.....................................................................24
2
To prevent the injury of the user or other people and property damage, the following instructions must be followed.
n Be sure to read before installing the air conditioner. n Be sure to observe the cautions specified here as they include important items related to safety. n Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is
classified by the following indications.
n The meanings of the symbols used in this manual are as shown below.
WARNING
CAUTION
This symbol indicates the possibility of death or serious injury.
This symbol indicates the possibility of injury or damage to properties only.
WARNING
n Installation
Be sure not to do.
Be sure to follow the instruction.
Safety Precautions
Installation Manual 3
Safety Precautions
ENGLISH
Always perform grounding.
• Otherwise, it may cause electrical shock.
Don’t use a power cord, a plug or a loose socket which is dam­aged.
• Otherwise, it may cause a fire or electrical shock.
For installation of the product, always con­tact the service center or a professional instal­lation agency.
• Otherwise, it may cause a fire, electrical shock, explosion or injury.
Securely attach the electrical part cover to the indoor unit and the service panel to the outdoor unit.
• If the electrical part cover of the indoor unit and the service panel of the outdoor unit are not attached securely, it could result in a fire or electric shock due to dust, water, etc.
Always install an air leakage breaker and a dedicated switching board.
• No installation may cause a fire and electri­cal shock.
Do not keep or use flammable gases or combustibles near the air conditioner.
• Otherwise, it may cause a fire or the failure of product.
4
Safety Precautions
Do not share the out­let with other appli­ances.
• It will cause an electric shock or a fire due to heat generation.
Do not use the dam­aged power cord.
• Otherwise, it may cause a fire or electri­cal shock.
Do not modify or extend the power cord randomly.
• Otherwise, it may cause a fire or electri­cal shock.
Take care so that the power cord may not be pulled during oper­ation.
• Otherwise, it may cause a fire or electri­cal shock.
Unplug the unit if strange sounds, smell, or smoke comes from it.
• Otherwise, it may cause electrical shock or a fire.
Keep the flames away.
• Otherwise, it may cause a fire.
n Operation
Use caution when unpacking and installing.
• Sharp edges may cause injury.
Use a vacuum pump or Inert (nitro­gen) gas when doing leakage test or air purge. Do not compress air or Oxygen and do not use Flammable gases. Otherwise, it may cause fire or explosion.
• There is the risk of death, injury, fire or explosion.
Ensure that an installa­tion frame of the out­door unit is not dam­aged due to use for a long time.
• It may cause injury or an accident.
Do not disassemble or repair the product ran­domly.
• It will cause a fire or electrical shock.
Do not install the prod­uct at a place that there is concern of falling down.
• Otherwise, it may result in personal injury.
Installation Manual 5
Safety Precautions
ENGLISH
Take the power plug out if necessary, hold­ing the head of the plug and do not touch it with wet hands.
• Otherwise, it may cause a fire or electri­cal shock.
Do not use the power cord near the heating tools.
• Otherwise, it may cause a fire and electri­cal shock.
Do not open the suc­tion inlet of the indoor/outdoor unit during operation.
• Otherwise, it may elec­trical shock and failure.
Do not allow water to run into electrical parts.
• Otherwise, it may cause the failure of machine or electrical shock.
Hold the plug by the head when taking it out.
• It may cause electric shock and damage.
Never touch the metal parts of the unit when removing the filter.
• They are sharp and may cause injury.
Do not step on the indoor/outdoor unit and do not put any­thing on it.
• It may cause an injury through dropping of the unit or falling down.
Do not place a heavy object on the power cord.
• Otherwise, it may cause a fire or electri­cal shock.
When the product is submerged into water, always contact the service center.
• Otherwise, it may cause a fire or electri­cal shock.
Take care so that children may not step on the outdoor unit.
• Otherwise, children may be seriously injured due to falling down.
6
Safety Precautions
CAUTION
n Installation
Install the drain hose to ensure that drain can be securely done.
• Otherwise, it may cause water leakage.
Install the product so that the noise or hot wind from the outdoor unit may not cause any damage to the neigh­bors.
• Otherwise, it may cause dispute with the neigh­bors.
Always inspect gas leakage after the instal­lation and repair of product.
• Otherwise, it may cause the failure of product.
Keep level parallel in installing the product.
• Otherwise, it may cause vibration or water leakage.
Please install safely at a place that can sufficiently endure the weight of the product.
• If the strength is not sufficient, the product may fall and cause injury.
n Operation
Avoid excessive cool­ing and perform venti­lation sometimes.
• Otherwise, it may do harm to your health.
Use a soft cloth to clean. Do not use wax, thinner, or a strong detergent.
• The appearance of the air conditioner may dete­riorate, change color, or develop surface flaws.
Do not use an appli­ance for special pur­poses such as preserv­ing animals vegetables, precision machine, or art articles.
• Otherwise, it may dam­age your properties.
Do not place obstacles around the flow inlet or outlet.
• Otherwise, it may cause the failure of appliance or an accident.
Installation of Outdoor Unit
Installation Manual 7
ENGLISH
1. Installation Places
• If an awning is built over the unit to prevent direct sunlight or rain exposure, make sure that heat radia­tion from the condenser is not restricted.
• Ensure that the spaces indicated by arrows around front, back and side of the unit.
• Do not place animals and plants in the path of the warm air.
• Take the air conditioner weight into account and select a place where noise and vibration are mini­mum.
• Select a place so that the warm air and noise from the air conditioner do not disturb neighbors.
• Place that can sufficiently endure the weight and vibration of the outdoor unit and where even installa­tion is possible
• Place that has no direct influence of snow or rain
• Place with no danger of snowfall or icicle drop
Place without weak floor or base such as decrepit part of the building or with a lot of snow accumulation
You need to select adequate installation location considering the following conditions, and make sure to acquire the consent of the user.
More than 300mm
Installation of Outdoor Unit
2. Piping length and the elevation
n Single Operation
If installed tube is shorter than 7.5 m, additional charging is not necessary. Additional Refrigerant = (A -7.5) x Additional refrigerant (g)
Unit : mm
Model Capacity
Pipe Size mm(inch)
Length A(m) Elevation B(m)
Additional refrigerant
(g/m)
Gas Liquid Standard Max. Standard Max. UU18W 5kW Ø12.7(1/2) Ø6.35(1/4) 7.5 40 5 30 20 UU24W 7kW Ø15.88(5/8) Ø9.52(3/8) 7.5 50 5 30 40 UU30W 8kW Ø15.88(5/8) Ø9.52(3/8) 7.5 50 5 30 40
UU36W/UU37W 10kW Ø15.88(5/8) Ø9.52(3/8) 7.5 50 5 30 40 UU42W/UU43W 12.5kW Ø15.88(5/8) Ø9.52(3/8) 7.5 75 5 30 40 UU48W/UU49W 14kW Ø15.88(5/8) Ø9.52(3/8) 7.5 75 5 30 40 UU60W/UU61W 15kW Ø15.88(5/8) Ø9.52(3/8) 7.5 75 5 30 40
Sunroof
More than 300mm
More than
More than
300mm
Fence or
obstacles
300mm
More than 600mm
More than 700mm
Indoor unit
A
B
Outdoor unit
Indoor unit
Outdoor unit
A
B
Installation of Outdoor Unit
• When installing the branch pipe, direction and angle of installation is not limited.
• Take care so that burrs and foreign material may not enter into the cutting surface when connecting.
• Connect remaining those by cutting or direct insertion to the diameter of pipe.
n Synchro Operation
Install the branch pipe so that pipe length and difference between high and low will not exceed below Spec.
[Unit : m]
Pipe Length & Height
Total(L1+L2+L3+L4+L5)
Main Pipe(L1)
Branch Pipe (L2+L3+L4+L5)
Each
Indoor-Outdoor (H1)
Indoor-Indoor (H2)
(L1+L2),(L1+L3),(L1+L4),(L1+L5)
A
Spec(MAX.)
80
45
40
15
30
1
70
10
8
n Refrigerant Additional Charging Method
For additional charging method, see below table.
Indoor Unit Refrigerant Additional charging (g)
Duo Trio
Quartet
Refrigerant = (L1-b) x B + (L2 + L3) x C Refrigerant = (L1-b) x B + (L2 + L3 + L4) x C Refrigerant = (L1-b) x B + (L2 + L3 + L4 + L5) x C
C
(g/m)
Pipe Size mm(inch)
Ø6.35(1/4)
Ø9.52(3/8)
35
40
b
(m)
Model
UU42W/UU43W UU48W/UU49W UU60W/UU61W
B
(g/m)
7.5 40
b : Rated performance for refrigerant line length. C : Additional charging Refrigerant of Branch Liquid Pipe. B : Additional charging Refrigerant of Main Liquid Pipe.
CAUTION:
• Capacity is based on standard length and maximum allowance length is on the basis of reliability.
• Improper refrigerant charge may result in abnormal cycle.
L2
L3
L4
L5
H1
Remote
Controller
L1
Branch
A
A
H2
NOTICE
Installation of Outdoor Unit
Installation Manual 9
ENGLISH
4.
Outdoor Unit PCB Setting Procedure For Simultaneous Operation System
** When using synchro operation,
- Do not use wireless remote controller.
- Use only one wired remote controller in the indoor units.
- Use Simple central controller "PQCSZ250S0" only.
3. Synchro Combination table
1. SW01N (PIP SW2) Setting
Set the SW01N (PIP SW2) as below Table (Ⓐ)
2. Auto Addressing Method Addressing work assigns address to each indoor unit. When firstly installing product or replacing the indoor unit PCB. Auto Addressing work should be done for simultaneous operation.
h Work procedure
1) Set SW01N (PIP SW2) correctly.
2) Turn on main power.
3) Press the SW02N (SW01B) for about 3 seconds within 3 minutes After main power on.(Ⓑ)
SW01B
LED01H
DIP SW2
A
B
MAIN PCBMAIN PCB
UU42W/48W/60W UU43W/49W/61W
LED01G LED02G
SW02N
SW01N
B
A
LED01M LED02M
6
Possible combination of indoor units
Synchro
Duo Trio Quartet
IDU : INDOOR UNIT ODU : OUTDOOR UNIT BD : BRANACH
DISTRIBUTOR UNIT
REMO : WIRED
REMOTE CONTROLLER
ODU
BD
IDU IDU
REMO
ODU
BD
IDU IDU IDU
REMO
BD
IDU IDU IDU IDU
ODU
REMO
MODEL
Cas­sette
Duct
Ceiling
Suspended
Cas­sette
Duct
Ceiling
Suspended
Cas­sette
Duct
Ceiling
Suspended
UU42W/UU43W
CT24 NP2*2 CB24 NH2*2 CV24 NJ2*2 CT18 NQ2*3 CB18 NH2*3 CV18 NJ2*3 CT12 NR2*4 - -
UU48W/UU49W
CT24 NP2*2 CB24 NH2*2 CV24 NJ2*2 CT18 NQ2*3 CB18 NH2*3 CV18 NJ2*3 CT12 NR2*4 - -
UU60W/UU61W
UT30 NP2*2 UB30 NG2*2 UV30 NJ2*2 CT18 NQ2*3 CB18 NH2*3 CV18 NJ2*3 CT12 NR2*4 - -
Applied Acces-
siries
Bdunit PMUB11A PMUB111A PMUB1111A Simple central
controller**
PQCSZ250S0
NOTICE
Loading...
+ 18 hidden pages