LG UU18WE INSTALLATION MANUAL

INSTALLATION MANUAL
AIR CONDITIONER
www.lg.com
P/NO : MFL68907801
Please read this installation manual completely before installing the product. Installation work must be performed in accordance with the national wiring standards by authorized personnel only. Please retain this installation manual for future reference after reading it thoroughly.
[
Representative] LG Electronics Inc. EU Representative : LG Electronics European Shared
Service Center B.V. Krijgsman 1, 1186 DM Amstelveen, The Netherlands
[Manufacturer] LG Electronics Inc. Changwon 2nd factory 84, Wanam-ro, Seongsan-
gu, Changwon-si, Gyeongsangnam-do, KOREA
Econo Inverter
Original instruction
ENGLISH
ESPAÑOL
Single A Air Conditioner Installation Manual
CONTENTS
Safety Precautions ..............................................................................................3
Installation of Outdoor Unit................................................................................7
Wiring Connection...............................................................................................8
Connecting Pipes ..............................................................................................11
Leakage test and Evacuation ...........................................................................14
Test running .......................................................................................................16
Self-diagnosis Function....................................................................................18
Installation Guide at the Seaside.....................................................................19
2
WARNING
CAUTION
WARNING
Safety Precautions
Safety Precautions
To prevent the injury of the user or other people and property damage, the following instructions must be followed.
n Be sure to read before installing the air conditioner. n Be sure to observe the cautions specified here as they include important items related to safety. n Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is
classified by the following indications.
This symbol indicates the possibility of death or serious injury.
This symbol indicates the possibility of injury or damage to properties only.
n The meanings of the symbols used in this manual are as shown below.
Be sure not to do.
Be sure to follow the instruction.
n Installation
Always perform grounding.
Don’t use a power cord, a plug or a loose socket which is dam­aged.
For installation of the product, always contact the service center or a professional installation agency.
ENGLISH
• Otherwise, it may cause electrical shock.
Securely attach the electrical part cover to the indoor unit and the service panel to the outdoor unit.
If the electrical part cover of the indoor unit and the service panel of the outdoor unit are not attached securely, it could result in a fire or electric shock due to dust, water, etc.
• Otherwise, it may cause
a fire or electrical shock.
Always install an air leakage breaker and a dedicated switching board.
• No installation may
• Otherwise, it may cause cause a fire and electri­cal shock.
Otherwise, it may cause a fire, electrical shock, explo­sion or injury.
Do not keep or use flammable gases or combustibles near the air conditioner.
a fire or the failure of product.
Installation Manual 3
Safety Precautions
Ensure that an installa­tion frame of the out­door unit is not dam-
Do not disassemble or repair the product ran-
domly. aged due to use for a long time.
• It may cause injury or an accident.
Do not install the product at a place that there is concern of falling down.
• Otherwise, it may result in personal
• It will cause a fire or electrical shock.
Use caution when unpacking and installing.
• Sharp edges may cause injury.
injury.
n Operation
Do not share the out­let with other appli-
Do not use the dam­aged power cord.
ances.
Use a vacuum pump or Inert (nitrogen) gas when doing leakage test or air purge. Do not compress air or Oxygen and do not use Flammable gases. Oth­erwise, it may cause fire or explosion.
• There is the risk of death, injury, fire or explosion.
Do not modify or extend the power cord randomly.
• It will cause an electric shock or a fire due to heat generation.
Take care so that the power cord may not be pulled during oper­ation.
• Otherwise, it may cause a fire or electri­cal shock.
4
• Otherwise, it may cause a fire or electri­cal shock.
Unplug the unit if strange sounds, smell, or smoke comes from it.
• Otherwise, it may cause electrical shock or a fire.
• Otherwise, it may cause a fire or electri­cal shock.
Keep the flames away.
• Otherwise, it may cause a fire.
Safety Precautions
Take the power plug out if necessary, hold­ing the head of the plug and do not touch it with wet hands.
• Otherwise, it may cause a fire or electri­cal shock.
Do not allow water to run into electrical parts.
• Otherwise, it may cause the failure of machine or electrical shock.
Do not step on the indoor/outdoor unit and do not put any­thing on it.
• It may cause an injury through dropping of the unit or falling down.
Do not use the power cord near the heating tools.
• Otherwise, it may cause a fire and electri­cal shock.
Hold the plug by the head when taking it out.
• It may cause electric shock and damage.
Do not place a heavy object on the power cord.
• Otherwise, it may cause a fire or electri­cal shock.
Do not open the suc­tion inlet of the indoor/outdoor unit during operation.
• Otherwise, it may elec­trical shock and failure.
Never touch the metal parts of the unit when removing the filter.
• They are sharp and may cause injury.
When the product is submerged into water, always contact the service center.
• Otherwise, it may cause a fire or electri­cal shock.
ENGLISH
Take care so that children may not step on the outdoor unit.
• Otherwise, children may be seriously injured due to falling down.
Installation Manual 5
Safety Precautions
CAUTION
n Installation
Install the drain hose to ensure that drain can be securely done.
Install the product so that the noise or hot wind from the outdoor unit may not cause any damage to the neighbors.
• Otherwise, it may cause water leakage.
• Otherwise, it may cause dispute with the neighbors.
Keep level parallel in installing the product.
• Otherwise, it may cause vibration or water leakage.
n Operation
Avoid excessive cool­ing and perform venti­lation sometimes.
Use a soft cloth to clean. Do not use wax, thinner, or a strong detergent.
Always inspect gas leakage after the installation and repair of product.
• Otherwise, it may cause the failure of product.
Please install safely at a place that can sufficiently endure the weight of the product.
• If the strength is not sufficient, the product may fall and cause injury.
Do not use an appli­ance for special pur­poses such as preserv­ing animals vegetables, precision machine, or art articles.
• Otherwise, it may do harm to your health.
• The appearance of the air conditioner may
• Otherwise, it may dam­age your properties.
deteriorate, change color, or develop sur­face flaws.
Do not place obstacles around the flow inlet or outlet.
• Otherwise, it may cause the failure of appliance or an accident.
6
Installation of Outdoor Unit
Sunroof
More than
700
More than
600
(Unit : mm)
ENGLISH
Installation of Outdoor Unit
You need to select adequate installation location considering the following conditions, and make sure to acquire the consent of the user.
1. Installation Places
• If an awning is built over the unit to prevent direct sunlight or rain exposure, make sure that heat radia­tion from the condenser is not restricted.
• Ensure that the spaces indicated by arrows around front, back and side of the unit.
• Do not place animals and plants in the path of the warm air.
• Take the air conditioner weight into account and select a place where noise and vibration are mini­mum.
• Select a place so that the warm air and noise from the air conditioner do not disturb neighbors.
• Place that can sufficiently endure the weight and vibration of the outdoor unit and where even installa­tion is possible
2. Piping length and the elevation
n Single Operation
Pipe Size
Model Capacity
UU18WE 5kW Ø12.7(1/2) Ø6.35(1/4) 7.5 25 5 15 20 UU24WE 7kW Ø15.88(5/8) Ø9.52(3/8) 7.5 30 5 15 40
mm(inch)
Gas Liquid Standard Max. Standard Max.
• Place that has no direct influence of snow or rain
• Place with no danger of snowfall or icicle drop Place without weak floor or base such as decrepit
• part of the building or with a lot of snow accumulation
Sunroof
More than
300
Fence or
obstacles
Length A(m) Elevation B(m)
Sunroof
More than
300
Additional refrigerant
(g/m)
If installed tube is shorter than 7.5 m, additional charging is not necessary. Additional Refrigerant = (A -7.5) x Additional refrigerant (g)
Indoor unit
B
A
Outdoor unit
Indoor unit
Outdoor unit
A