Room Air Conditioner
SVC MANUAL(Exploded View)
MODEL : TS-C2425DA1 TS-C2425ML1
CAUTION
Before Servicing the unit, read the safety precautions in General SVC manual.
Only for authorized service personnel.
http://biz.lgservice.com
1. Specification
Product Model TS-C2425DA1
Sales Model SJ242CD
Capacity
Cooling Capacity
Electrical Parts
Voltage. Frequency/Phase
Power Input Cooling W
2560
Heating W
-
Running Current Cooling A
12.0
Indoor,Max
㎥
/min(cfm)
14.5
Outdoor,Max
㎥
/min(cfm)
42
Moisture Removal l/h
2.9
Sound Level
Feature
Neo Plasma Air Purifying System
N
Anti Corrasion
N
Temperature Control
Y
CHAOS Wind(Auto Wind)
N
Airflow Direction Control(up&down)
Auto
Airflow Direction Control(left&right)
Manual
Remocon Type
Wireless Simple
Setting Temperature Range Cooling
18-30
Heating
-
Auto Chage Over
N
Auto Clean
N
Seps,Fan/Cool
3/4
Temperature Increment
Timer
7Hr,Off
Sleep Operation
Y
Restart Delay(Minute)
3
Hot start
-
Jet Cool
Y
Compressor Type
Rotary,TS35N(Mitsubishi)
Installation & Stuffing
Net Dimensions WxHxD mm
Net Weight Indoor/Outdoor kg
14/51
Note:
O
: Applied, - : No relation
*
For circuit breaker rating, please conform to local standards wherever necessary.
2 Room Air Conditioner
Some of functions are slightly different depending upon models.
The specification may be subject to change without prior notice for purpose of
improvement.
1. Specification
Product Model TS-C2425ML1
Sales Model SP242CM
Capacity
Cooling Capacity
Electrical Parts
Voltage. Frequency/Phase
Power Input Cooling W
2560
Heating W
-
Running Current Cooling A
12.0
Indoor,Max
㎥
/min(cfm)
14.5
Outdoor,Max
㎥
/min(cfm)
42
Moisture Removal l/h
2.9
Sound Level
Feature
Neo Plasma Air Purifying System
Y
Anti Corrasion
N
Temperature Control
Y
CHAOS Wind(Auto Wind)
New Chaos
Airflow Direction Control(up&down)
Auto
Airflow Direction Control(left&right)
Manual
Remocon Type
Wireless LCD
Setting Temperature Range Cooling
18-30
Heating
-
Auto Chage Over
N
Auto Clean
N
Seps,Fan/Cool
3/4
Temperature Increment
Timer
7Hr,Off
Sleep Operation
Y
Restart Delay(Minute)
3
Hot start
-
Jet Cool
Y
Compressor Type
Rotary,TS35N(Mitsubishi)
Installation & Stuffing
Net Dimensions WxHxD mm
Net Weight Indoor/Outdoor kg
14/51
Note:
O
: Applied, - : No relation
*
For circuit breaker rating, please conform to local standards wherever necessary.
Some of functions are slightly different depending upon models.
The specification may be subject to change without prior notice for purpose of