Room Air Conditioner
SVC MANUAL(Exploded View)
MODEL : TS-C096YDA1 TS-C126TDA1
CAUTION
Before Servicing the unit, read the safety precautions in General SVC manual.
Only for authorized service personnel.
http://biz.lgservice.com

2 Room Air Conditioner
1. Specification
Note:
O
: Applied, - : No relation
*
For circuit breaker rating, please conform to local standards wherever necessary.
Some of functions are slightly different depending upon models.
The specification may be subject to change without prior notice for purpose of
improvement.
TS-C096YDA1 TS-C126TDA1
2.6 3.4
9,000 12,000
Power Input
Cooling/Heating 850 1,110
Running Current
Cooling/Heating 3.8 5
Starting Current
Cooling/Heating
53/53 53/53
1/220-240/50 1/220-240/50
Indoor,Max
6.7 6.7
Outdoor,Max
26 26
Indoor,H/M/L
36/-/- 39/-/-
Outdoor,Max
51 53
R22, 1180(41.62) R22, 1300(45.85)
50(0.55) 50(0.55)
Rotary(Non Tropical) Rotary(Non Tropical)
PH165X1C-4FTDE3 PH215X2C-4FT1
SUNISO 4GSI SUNISO 4GSI
Oil Charge 400 480
MRA13430-9087 INSIDE
Cross Flow Fan Cross Flow Fan
Motor Output 11 11
Propeller Propeller
AC Induction AC Induction
Motor Output 27 77
10 13
3*0.75 3*1.5
3*0.75 3*1.5
Liquid Side
6.35(1/4) 6.35(1/4)
Gas Side
12.7(1/2) 12.7(1/2)
Drain Hose O.D , I.D 21.5,16(0.85,0.63) 21.5,16(0.85,0.63)
840*270*161 895*282*166
33.07*10.63*6.34 35.24*11.10*6.53
770*540*245 840*577*276
30.31*21.26*9.65 33.07*22.72*10.87
Indoor 7(15.4)
8(17.6)
Outdoor 33(72.6) 47(103.4)
Cooling(Outdoor)
Heating(Outdoor)
15 15
7.5(25) 7.5(25)
Tool Code(Chassis) SY+UL ST+UM
- -
○ ○
- -
○ ○
3/4/3 3/4/3
Auto Auto
Manual Manual
Wireless LCD Wireless LCD
Cooling Capacity
(Min∼Rating∼Max)
Heating Capacity
(Min∼Rating∼Max)
Refrigerant & Charge(at 7.5m)
Additional Refrigerant Charge
Power and Transmission Cable
Max. Elevation Difference
Prefilter(washable/anti-fungus)
Airflow Direction Control(up&down)
Airflow Direction Control(left&right)
Setting Temperature
Range
- -
- -
○ ○
7h, On/Off 7h, On/Off
○ ○
○ ○
3 3
○ ○
- -
○ ○
Low Ambient Operation--
- -
- -
- -
- -
Auto Operation (Micom Control)
Auto Changeover (Micom Control)

Service Manual 3
2. Piping Diagrams
Indoor Unit Outdoor Unit
Heat
Exchanger
(Evaporator)
Heat
Exchanger
(Condenser)
Capillary Tube
Compressor
Accumulator
Gas Side
3-Way Valve
2-Way Valve
Liquid Side
Cooling
High Pressure S/W
Th1
Th2
LOC. Description PCB Connector
Th1 Thermistor for indoor air temperature
CN-TH1
Th2 Thermistor for evaporating temperature

4. Exploded View
Note) * Please ensure GCSC since the replacement parts may be changed depending upon the buyer's request.
Please check the correct parts in View RPL(Replacement Part List) on GCSC.
(GCSC Website http://biz.Lgservice.com,)
Indoor Unit
135314
152302
342800
264110
263230
359011
131410
135316
135311
147581
268712
146811
W6640
346810
135516
35211B
354210
249951
268711
267110
135312
11
5
531
4
0
3
9
4
1
354212
352150
147582-2
W0CZZ
W3300
237900
435301
147582-1
249941
Service Manual 7

8 Room Air Conditioner
Note) * Please ensure GCSC since the replacement parts may be changed depending upon the buyer's request.
Please check the correct parts in View RPL(Replacement Part List) on GCSC.
(GCSC Website http://biz.Lgservice.com,)
Outdoor Unit
W0CZZ
W6640
649950
552203-2
552203-1
447910
554031
550140
148000
546810
430400
567502
552117
237202
149310
349600
430410
552112
552201
552114
W6631
TS-C096YDA1