LG SKSWK245LS, SKSWK245RS Owner’s Manual

SERVICE MANUAL
CONFIDENTIAL
BUILT IN WINE CELLAR
MODEL : SKSCW181RP
SKSCW241RP
MFL67262420
Any reproduction, duplication, distribution (including by way of email, facsimile or other electronic means), publication,
www.signaturekitchensuite.com
Copyright © 2018 - 2019 SIGNATURE KITCHEN SUITE. All rights reserved. Only training and service purposes.
CONTENTS
1. SAFETY PRECAUTIONS ............................................................................................................................................................3
2. PRODUCT STANDARDS ............................................................................................................................................................ 4
3. CIRCUIT DIAGRAM .................................................................................................................................................................5-6
4. SPECIFICATIONS ....................................................................................................................................................................7-9
5. MICOM FUNCTION ..............................................................................................................................................................10-11
6. TROUBLE SHOOTING.........................................................................................................................................................12-24
7. TROUBLE SHOOTING WITH ERROR DISPLAY ................................................................................................................25-43
8. HOW TO DISASSEMBLE AND ASSEMBLE
1. Door ........................................................................................................................................................................................44
2. Knock-on ..........................................................................................................................................................................45-46
3. Top Cover .............................................................................................................................................................................. 47
4. Door Switch / SDS PCB / Temperature sensor .................................................................................................................. 48
5. Machine Room Cover ........................................................................................................................................................... 49
6. Machine Room Cycle.......................................................................................................................................................50-53
7. Wi-Fi .......................................................................................................................................................................................54
8. Power Cord ............................................................................................................................................................................ 55
9. Main PCB ..........................................................................................................................................................................56-57
10. Control Panel ......................................................................................................................................................................58
11. Shelf .....................................................................................................................................................................................59
12. Slide Rail .............................................................................................................................................................................60
13. Holder Rail .......................................................................................................................................................................... 61
14. Top Duct ............................................................................................................................................................................... 62
15. Grille Fan .............................................................................................................................................................................63
16. Multi Duct ............................................................................................................................................................................64
17. Defrost Sensor ................................................................................................................................................................... 65
18. Barrier ..................................................................................................................................................................................66
9. SEALED SYSTEM REPAIR METHOD OF REFRIGERATOR WITH R600A REFRIGERANT ...........................................67-73
10. EXPLODED VIEW .............................................................................................................................................................74-81
- 2 -
Copyright © 2018-2019 SIGNATURE KITCHEN SUITE. All rights reserved. Only training and service purposes.
1. SAFETY PRECAUTIONS
Please read the following instructions before servicing your refrigerator.
1. Unplug the powr before handing any electrical componets.
2. Check the rated current, voltage, and capacity.
3. Take caution not to get water near any electrical components.
4. Use exact replacement parts.
5. Remove any objects from the top prior to tilting the product.
- 3 -
Copyright © 2018-2019 SIGNATURE KITCHEN SUITE. All rights reserved. Only training and service purposes.
2. PRODUCT STANDARDS
Model Name
Effective inner capacity 274L (9.7 Cu.ft) 385L (13.6 Cu.ft)
Outer dimension (W x D x H)
Rated voltage and frequency 115V / 60Hz 115V / 60Hz
Product weight (kg) 139kg (306lb) 162kg (357lb)
Cooling method Fan Cooling Fan Cooling
Defrost system Natural Defrost system Natural Defrost system
Lay-out
Temperature
control
Model Name
Room 2 (1 Barrier) 3 (2 Barrier)
Shelf 9 (Upper:4EA, Lower:5EA) 8 (Upper:4EA, Mid:2EA, Lower:2EA)
Upper-Room Micom Control Micom Control
Middle-Room - Micom Control
Lower-Room Micom Control Micom Control
Compressor driving method
Evaporator Rollbond Type Rollbond Type
Condenser Micro Channel Condenser (Al) Micro Channel Condenser (Al)
SKSCW181RP SKSCW241RP
"445 × 607× 2121 mm
(17 1/2 x 23 7/8 x 83 1/2 inch)"
Linear Linear
"603 × 607× 2121 mm
(23 3/4 x 23 7/8 x 83 1/2 inch)"
Cycle
"Electrical parts
standard"
Compressor Oil Mineral / Freol Alpha 3G (3cst) (120cc) Mineral / Freol Alpha 3G (3cst) (120cc)
Type of refrigerant R 600a (42g) R 600a (44g)
Capillary tube 0.75 0.75
Dryer (Capillary Tube) Molecular-sieves XH-9 Molecular-sieves XH-9
Valve 3Way Valve 4Way Valve
Heater AC 115V / 33W * 2EA AC 115V / 33W * 3EA
Overload protective device 4MPS41F9-01 4MPS41F9-01
Cold Fan motor DC 12V DC 12V
Fan motor for cooling
condenser
Inside lamp
Main Fuse 125V / 10A 125V / 10A
Valve DC 12V DC 12V
DC 12V DC 12V
15.4W 28.2W
- 4 -
Copyright © 2018-2019 SIGNATURE KITCHEN SUITE. All rights reserved. Only training and service purposes.
3. CIRCUIT DIAGRAM
24” : W1(Upper)/W2(Middle)/W3(Lower) 18” : W1(Upper)/W2(Lower)
POWER
CORD
ICE MAKER MOTOR
ICE MAKER SENSOR
ICE MAKER MOTOR ON-OFF SWITCH
ICE MAKER MOTOR TEST SWITCH
DISPENSER SWITCH
DEW HEATER
WATER PIPE HEATER
W1 DEFROSTING SENSOR
W2 DEFROSTING SENSOR
W3 DEFROSTING SENSOR
3WAY/4WAY VALVE
W1 SENSOR
W2 SENSOR
W3 SENSOR
W1 LED LIGHT
W2 LED LIGHT
W3 LED LIGHT
FUSE-M
FUSE-M
FUSE-M
CIRCUIT DIAGRAM
1
BK
3
SB
FUSE
HALL IC
1 2 5 6
3.4
W2
DEFROSTING
HEATER
FUSE-M
W3
DEFROSTING
FUSE-M
HEATER
W1
DEFROSTING
FUSE-M
HEATER
W2 DEFROSTING HEATER
W3 DEFROSTING HEATER
W1 DEFROSTING HEATER
GROUNDING
VCC GND VCC GND VCC GND
COM
A B A­B-
5
OVERLOAD
DEVICE
7
9 11 13 15 17 19 21 23 25 27 29 31 33
2
4
6
8 10 12 14 16 18 20 22 24 26 28 30 32 34
1
2
3
4
5
6
7
1
3
5
7
9 11 13 15 17 19 21 23 25 26
2
4
6
8 10 12 14 16 18 20 22 24
WH
BK
CON1/ CON1_1
2 4 6
8 10 12 14 16 18 20 22 21
1
3
5
7
9 11 13 15 17 19
WH
1
WH
3
BO/BL
5
BO/BL
7
BK
9
BK
11
RD
13
RD
15
BO
17
BO
19
BL
21
BL
23
2
4
6
8 10 12
SB
14
GY/RD
16
YL
18
WH/BK
20
PK
22 24
D-N※ D-N : Defrosting Heater- N
1 2 3 4 5 6 7
PK
1 2 3 4
BN
5 6
WH
7 8
BK
9
10
GR/YL
11
PROTECTION
BL/WH BL/WH
RD
GY/WH
BL BO
WH/RD
BN BN
PK
BO/WH
PR
BL
RD
BK
YL GY BO RD PK
RD/YL
BL
YL/BL WH/BN PR/WH
BK BN
WH/RD
WH
BL/RD
PR SB/BK BO/WH BO/BL YL/BK WH/BK BL/WH
5V
H_SENSOR
GND
A A-
STEPPING
B-
MOTOR DAMPER
B
12V GND RX TX 5V
5V
GND
SIG
5V
GND
SIG A A-
STEPPING
B-
MOTOR DAMPER
B
COMPRESSOR
SMART BUZZER
H_SENSOR
DOOR 1 SWITCH
DOOR 2 SWITCH
DOOR 3 SWITCH
DAMPER HEATER
OUTDOOR SENSOR
1
YL
2
BK
3
RD
1
YL
2
BK
3
RD
LINEAR
COMPRESSOR
GROUNDING
W1 FAN
W1 LED PWM LIGHT
HYGIENE FAN MOTOR
MACHINE ROOM FAN
HYGIENE LED LIGHT
W2 FAN
W2 LED PWM LIGHT W3 LED PWM LIGHT
W3 FAN
5V TX RX
GND
KNOCK ON SENSOR 1
KNOCK ON SENSOR 2
OVERLOAD
PROTECTION
DEVICE
MBM6633
5905
9.0 SEC
8.0 SEC
10.0 SEC
11.0 SEC
- 5 -
Copyright © 2018-2019 SIGNATURE KITCHEN SUITE. All rights reserved. Only training and service purposes.
3. CIRCUIT DIAGRAM
SCHÉMA DE CIRCUIT
MBM66335905
24” : W1(supérieur)/W2(Moyen)/W3(*OG¨SJFVS) 18” : W1(supérieur)/W2(*OG¨SJFVS)
FICHE
SECTEUR
NEUTRE
CIRCUIT INTÉGRÉ EFFET HALL
MOTEUR DE L’APPAREIL À GLAÇONS
CAPTEUR DE L’APPAREIL À GLAÇONS
INTERRUPTEUR MARCHE/ARRÊT MOTEUR DE L’APPAREIL À GLAÇONS
INTERRUPTEUR DE TEST MOTEUR DE L’APPAREIL À GLAÇONS
INTERRUPTEUR DU DISTRIBUTEUR
CHAUFFAGE DE LA ROSÉE
CHAUFFAGE DE LA CONDUITE D’EAU
CAPTEUR W1
CAPTEUR DE DÉGIVRAGE W1
CAPTEUR W2
CAPTEUR DE DÉGIVRAGE W2
CAPTEUR W3
CAPTEUR DE DÉGIVRAGE W3
ÉCLAIRAGE LED W1
ÉCLAIRAGE LED W2
ÉCLAIRAGE LED W3
SOUPAPE 3 VOIES/4 VOIES
※ D-N : CHAUFFAGE DE DÉGIVRAGE- N
CHAUFFAGE DE
FUSIBLE-M
DÉGIVRAGE W2
CHAUFFAGE DE
FUSIBLE-M
DÉGIVRAGE W3
FUSIBLE-M
RÉACTEUR
SOUS
FUSIBLE
TENSION
VCC GND VCC GND VCC GND
FUSIBLE-M
FUSIBLE-M
FUSIBLE-M
COM
A B A­B-
1 2 5 6
3.4
CHAUFFAGE DE DÉGIVRAGE W1
CHAUFFAGE DE DÉGIVRAGE W2
CHAUFFAGE DE DÉGIVRAGE W3
CHAUFFAGE DE DÉGIVRAGE W1
MISE À TERRE
D-N
WH
BK
CON1/ CON1_1
2 4 6
8 10 12 14 16 18 20 22 21
1
3
5
7
9 11 13 15 17 19
1
3
BO/BL
5
BO/BL
7
9 11 13 15 17 19 21 23
2
4
6
8 10 12 14
GY/RD
16 18
WH/BK
20 22 24
1 2 3 4 5 6 7
1 2 3 4 5 6 7 8 9
10
GR/YL
11
1
BK
3
SB
BL/WH BL/WH
RD
GY/WH
BL BO
WH/RD
BN BN PK
BO/WH
PR
BL
RD
BK
YL GY BO RD PK
RD/YL
BL
YL/BL WH/BN PR/WH
BK BN
WH/RD
WH
BL/RD
PR SB/BK BO/WH BO/BL YL/BK WH/BK BL/WH
5V
Capteur d’humidité
GND
A A­B­B
12V GND RX TX 5V
A A­B­B
5
7
9 11 13 15 17 19 21 23 25 27 29 31 33
2
4
6
8 10 12 14 16 18 20 22 24 26 28 30
PROTECTION CONTRE LES SURCHARGES
32 34
1
2
3
4
5
6
7
1
3
5
7
9 11 13 15 17 19 21 23 25 26
2
4
6
8 10 12 14 16 18 20 22 24
WH WH
BK
BK RD RD BO BO
BL
BL
SB
YL
PK
PK
BN
WH
BK
DISPOSITIF DE
ALARME INTELLIGENTE
CAPTEUR D’HUMIDITÉ
INTERRUPTEUR PORTE 1
INTERRUPTEUR PORTE 2
INTERRUPTEUR PORTE 3
CHAUFFAGE DU REGISTRE
REGISTRE DU MOTEUR PAS À PAS
AFFICHER
CAPTEUR EXTÉRIEUR
5V
1
YL
GND
2
BK
SIG
3
RD
5V
1
YL
GND
2
BK
SIG
3
RD
REGISTRE DU MOTEUR PAS À PAS
COMPRESSEUR
LINÉAIRE
BASES DU
COMPRESSEUR
VENTILATEUR W1
LAMPE LED PWM W1
MOTEUR VENTILATEUR HYGIÈNE
VENTILATEUR LOCAL TECHNIQUE
LAMPE LED HYGIÈNE
VENTILATEUR W2
LAMPE LED PWM W2 LAMPE LED PWM W3
VENTILATEUR W3
5V TX RX
GND
TAPER SUR LE CAPTEUR 1
TAPER SUR LE CAPTEUR 2
DISPOSITIF DE
PROTECTION CONTRE LES SURCHARGES
9.0 SEC
8.0 SEC
10.0 SEC
11.0 SEC
- 6 -
Copyright © 2018-2019 SIGNATURE KITCHEN SUITE. All rights reserved. Only training and service purposes.
4. SPECIFICATIONS
FRONT VIEW
SIDE VIEW
TOP VIEWS
● SPECIFICATIONS
ITEMS SPECIFICATIONS
DOOR DESIGN Side Rounded
DIMENSIONS
NET WEIGHT
18W
24W
18W 139kg (306lb)
24W 162kg (357lb)
17 1/2 x 23 7/8 x 83 1/2 (W X D X H)
23 4/3 x 23 7/8 x 83 1/2 (W X D X H)
COOLING SYSTE M Fan Cooling
TEMPERATURE CONTROL Micom Control
DEFROSTING SYSTEM
Natural Defrost System
DOOR FINISH GI
HANDLE TYPE Bar
INNER CASE Aluminum
INSULATION Polyurethane Foam
● DIMENSIONS
(A)
(B)
(C)
(D)
ITEMS SPECIFICATIONS
COMPRESSOR Linear
EVAPORATOR Rollbond Type
CONDENSER Micro channel Condenser (Al)
REFRIGERANT
LUBRICATING OIL
18W R 600a (42g)
24W R 600a (44g)
Mineral / Freol Alpha 3G (3cst)
(120cc)
LAMP LED Module
(A)
(F)
DOOR OPEN 115˚
(G)
min.
(H)
max.
(A)
(G)
min.
(H)
max.
(E)
DOOR OPEN 90˚
Description SKSCW181RP SKSCW241RP
Width Width (A) 17 1/2"(445mm) 23 3/4"(603mm)
Depth with 3/4"(19mm) Door panel (B) 24 3/4"(629mm) 24 3/4"(629mm)
Depth with door (No panel) ( C ) 23 7/8"(607mm) 23 7/8"(607mm)
Depth
Cabinet depth without Door (D) 22"(558mm) 22"(558mm)
Door Open 90º (E) 21 7/8"(556m) 28 1/8"(713mm)
Door Open 115º (F) 20 1/2"(520mm) 26 1/2"(659mm)
Height
Min (G) 83 1/2"(2121mm) 83 1/2"(2121mm)
Max (H) 84 1/2"(2146mm) 84 1/2"(2146mm)
Copyright © 2018-2019 SIGNATURE KITCHEN SUITE. All rights reserved. Only training and service purposes.
- 7 -
● Parts
MODEL : SKSCW181RP
Control Panel
LED Interior
Lighting
Storage Rack
Zone Divider
LED Interior
Lighting
- 8 -
Copyright © 2018-2019 SIGNATURE KITCHEN SUITE. All rights reserved. Only training and service purposes.
● Parts
MODEL : SKSCW241RP
Control Panel
LED Interior
Lighting
Zone Divider
LED Interior
Lighting
Storage Rack
Zone Divider
LED Interior
Lighting
- 9 -
Copyright © 2018-2019 SIGNATURE KITCHEN SUITE. All rights reserved. Only training and service purposes.
5. MICOM FUNCTION
● Operating panel drawing (Applied display is different for each model)
- MODEL : SKSCW181RP
NOTCH
Upper/
Lower
Set
Temper
ature
- MODEL : SKSCW241RP
10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 1 2 3 4 5 6 7 8 9
55˚F 54˚F 53˚F 52˚F 51˚F 50˚F 49˚F 48˚F 47˚F 46˚F 45˚F 44˚F 43˚F 42˚F 41˚F 64˚F 63˚F 62˚F 61˚F 60˚F 59˚F 58˚F 57˚F 56˚F
NOTCH
Upper/ Middle Lower/
Set
Temper
ature
10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 1 2 3 4 5 6 7 8 9
55˚F 54˚F 53˚F 52˚F 51˚F 50˚F 49˚F 48˚F 47˚F 46˚F 45˚F 44˚F 43˚F 42˚F 41˚F 64˚F 63˚F 62˚F 61˚F 60˚F 59˚F 58˚F 57˚F 56˚F
- 10 -
Copyright © 2018-2019 SIGNATURE KITCHEN SUITE. All rights reserved. Only training and service purposes.
● Description of Function
- MODEL : SKSCW181RP
- Model : SKSCW241RP
Temperature setting
Humidity
Light
Wi-Fi
Power
: The FAN motor for humidity in the refrigerator will be activated or deactivated whenever pressing the button.
: Inner LED turns on/off whenever pressing the button
: The Wi-Fi Icon is blinked when press and hold the button for 3 sec. And then,
- Wi-Fi Connecting : Wi-Fi Icon turns on.
- Wi-Fi Disconnecting : Wi-Fi Icon turns off after 3 min.
: The Power Icon always on. If the power button is pressed and hold for 3 sec., it turns off.
: Indicates the set temperature of the Refrigerator compartment in Celsius or Fahrenheit.
- 11 -
Copyright © 2018-2019 SIGNATURE KITCHEN SUITE. All rights reserved. Only training and service purposes.
6. TROUBLE SHOOTING
Open the PCBA Cover
1. COMP Bad Operation
Open the PCBA Cover
Check the LED blinking times (Refer to the next chapter for LED blinking and actions.)
If the Comp is normal, the LED does not blink.
- 12 -
Copyright © 2018-2019 SIGNATURE KITCHEN SUITE. All rights reserved. Only training and service purposes.
2. Simple Check Flow Chart
- Not Cooling (LED Blinking)
LED 8 Blinks
LED 7 Blinks
LED 1 Blinks
LED 4 Blinks
LED 5 Blinks
LED 2 Blinks
LED 3 Blinks LED 3 Blinks
Replace PCB
N
Reset
Reset
Reset
Reset
Reset
Reset
PCBA
Output
> 60V?
Y
Check C
omp.
Test Mode
1 Input
Test Mode
1 Input
Test Mode
1 Input
Test Mode
1 Input
Test Mode
1 Input
Test Mode
1 Input
Test Mode
1 Input
N
About 5min
About 5min
About 5min
About 5min
About 5min
About 5min
About 5min
Harness
wiring?
Y
Repair Harness
LED 8 Blinks
LED 7 Blinks
LED 1 Blinks
LED 4 Blinks
LED 5 Blinks
LED 2 Blinks
N
Action?
Cycle leakage
Comp.
Y
Cycle
Replace PCBReset
Replace PCB
Replace PCB
Replace PCB
Comp.
Action?
Y
Check Comp.
Cycle leakage
N
Check
LED6 Blinks
LED Trip Information
1 Current/Voltage Sensing Error 2 Over Stroke 3 Comp Connection Error 4 Over Voltage Error 5 Comp Lock Error
6 Over Current Error
7 IPM Error 8 Communication Error
- Not Cooling (LED No Blinking)
Test Mode
1 Input
Reset
About 5min
Test Mode
1 Input
Replace PCB
N
Y
Check Comp.
Comp.
Action?
About 5min
PCBA
Output
> 60V
N
LED 6 Blinks
N
Comp.
Action?
Y
Check
Cycle leakage
PCBA
Output
> 60V
N
Replace PCB
- 13 -
Copyright © 2018-2019 SIGNATURE KITCHEN SUITE. All rights reserved. Only training and service purposes.
3. What to do per LED Blinking and Trip protection logic
(1) FCT0 Trip and LED Blinking 1 time (FCT0 Fault)
Blink BlinkOFF OFF
→ Purpose : To detect the compressor voltage and current sensing error.
→ Restart every 30 seconds after compressor off.
LED 1 Blinks
Test Mode
1 Input
About 5minReset
LED 1 Blinks
Replace PCB
- 14 -
Copyright © 2018-2019 SIGNATURE KITCHEN SUITE. All rights reserved. Only training and service purposes.
3. What to do per LED Blinking and Trip protection logic
(2) Stroke Trip and LED Blinking 2 times (Stroke Trip)
Blink Blink Blink BlinkOFF OFF
→ Purpose : Protection piston crash by abnormally large Stroke.
→ Case 1. Do not operate Comp.
: Harness connection failure between the PCB, Comp, Capacitor.
→ Case 2. Do operate Comp. intermittently
: Condenser Fan or Freezer Fan Error. System Error like water-clogging, capillary-clogging, refrigerant-leakage
→ Logic: After the Comp. Off every 1 minute restart Comp.
Check
the Protection Logic
Check the
leakage and cycle
Recheck
Check Stroke or
LED Blinking 2 times
(Stroke Trip)
Do not operate
Comp.?
N
Y
N
Stroke Trip
occur?
Repair Harness
N
Y
Check
Harness connection
Compressor is operate
intermittently
Reset
Y
Y
Check Comp.
Y
N
- 15 -
Replace
Compressor
Copyright © 2018-2019 SIGNATURE KITCHEN SUITE. All rights reserved. Only training and service purposes.
3. What to do per LED Blinking and Trip protection logic
Check
Compressor
(3) No Connect Trip and LED Blinking 3 times (No Connection Trip)
Blink Blink Blink BlinkBlinkBlink OFF OFF
→ Purpose : Prevention Over-Voltage and Over-Current by detecting connection error check.
→ Harness connection failure between PCB, Comp, Capacitor.
Comp. insulation breakdown.
→ Logic : After the Comp. Off every 40 seconds restart Comp.
Check
the Protection Logic
Replace PCB
Recheck
No Connect or
LED blinking 3 times
(No Connect Trip)
Do not operate
Comp.?
N
Y
N
No Connect Trip
occur?
Y
Repair Harness
N
Check
Harness connection
Y
Reset
Check Comp.
Y
N
- 16 -
Replace
Copyright © 2018-2019 SIGNATURE KITCHEN SUITE. All rights reserved. Only training and service purposes.
3. What to do per LED Blinking and Trip protection logic
(4) Over Voltage Trip and LED Blinking 4 times (Over Voltage Trip)
Blink Blink Blink Blink BlinkBlinkBlink Blink OFF OFF
→ Purpose : Protection the PCB by Over Voltage
→ Cause : Applying the Over Voltage to DC Link(450VDC or higher)
→ Logic: Restart every 90 seconds after compressor off.
LED 4 Blinks
Test Mode
1 Input
About 5minReset
LED 4 Blinks
Replace PCB
- 17 -
Copyright © 2018-2019 SIGNATURE KITCHEN SUITE. All rights reserved. Only training and service purposes.
3. What to do per LED Blinking and Trip protection logic
(5) L/Piston Trip and LED Blinking 5 times (Locked Piston)
Blink Blink BlinkBlink Blink OFF
→ Purpose : Detect locked piston.
→ Cause : Oil shortage of the cylinder, Cylinder or Piston damage, clogging the discharge,
Comp. internal debris.
→ Logic : After the Comp. Off every 2 min 30 seconds restart Comp.
Check
the Protection Logic
Check the L/Piston or
LED blinking 5 times
(Locked Piston Trip)
Do not operate
Comp.?
Reset
Do not operate
Comp.?
N
Replace
Compressor
N
Y
Clogging the Cycle?
Y
Recheck
- 18 -
Repair
Sealed system
Copyright © 2018-2019 SIGNATURE KITCHEN SUITE. All rights reserved. Only training and service purposes.
3. What to do per LED Blinking and Trip protection logic
(6) Current Trip and LED Blinking 6 times (Current Trip)
Blink Blink Blink BlinkBlinkBlink OFF
→ Purpose : Protection Over-Current(Over-Load)
→ Cause : Abnormally ambient temperature(Over 43°C), Abnormally conditions like
Shield machine room etc. Condenser Fan failure, Comp. failure, PCB failure (IPM breakdown) Oil shortage of the cylinder, Cylinder or Piston damage, clogging the discharge, Comp. internal debris.
→ Logic : After the Comp. Off every 6 minutes restart Comp.
Check
the Protection Logic
Recheck
Check the
leakage and cycle
Check the Current or
LED blinking 6 times
(Current Trip)
Replace PCB
Replace
Compressor
N
Current trip
occur?
Y
N
Do not operate
Comp.?
N
N
Compressor is operate
intermittently
N
Check the
PCB output
Reset
Y
Clogging the Cycle?
Y
Y
Check the
Compressor failure
Y
Repair
Sealed system
- 19 -
N
Y
Replace
Compressor
Copyright © 2018-2019 SIGNATURE KITCHEN SUITE. All rights reserved. Only training and service purposes.
3. What to do per LED Blinking and Trip protection logic
(7) IPM Fault Trip and LED Blinking 7 times (IPM Fault)
Blink Blink Blink
→ Purpose : Protection Over-Current by failure IPM(IPM short)
→ Cause : IPM Short and failure
→ Logic : After the Comp. Off every 20 seconds restart Comp.
LED 7 Blinks
BlinkBlink OFF
Blink Blink
Test Mode
1 Input
About 5minReset
LED 7 Blinks
Replace PCB
- 20 -
Copyright © 2018-2019 SIGNATURE KITCHEN SUITE. All rights reserved. Only training and service purposes.
3. What to do per LED Blinking and Trip protection logic
(8) Comp Tx Error Trip and LED Blinking 8 times (Communication Error)
Blink Blink Blink
→ Purpose : Detection communication error with the Micom of the refrigerator control.
→ Cause : Communication Error
→ Logic : Only LED blinking without the Comp. Off
(Comp. is operate command before communication error)
LED 8 Blinks
BlinkBlink OFF
Blink Blink Blink
Test Mode
1 Input
About 5min
LED 8 Blinks
Replace PCBReset
- 21 -
Copyright © 2018-2019 SIGNATURE KITCHEN SUITE. All rights reserved. Only training and service purposes.
4. Check the PCB Output
→ Check output voltage from PCB to Compressor.
IPM Output check
Multi
Tester
SAMPLE
SAMPLE
→ To judge whether there is any issue with the PCB operation, check the PCB output voltage.
Normal: Voltage 80[V] or higher output at (COMMON,POWER) or (COMMOM,SAVE)
- 22 -
Copyright © 2018-2019 SIGNATURE KITCHEN SUITE. All rights reserved. Only training and service purposes.
5. Check the Compressor & Harness
(1) Check the Harness connection → Step 1. Power off.
(2) Check the Compressor Step 2. Check the Resistance(point A)
Step 3. Check the Harness(INF ohm).
Step 4. Check the Resistance(point B)
Step 5. Check the Resistance(point D)
Power
off
Check
the Resistance
(point B)
Y
A~B
Connection error
Y
N
Check the
Resistance
(point A)
N
Check
the Resistance
(point D)
Y
B~D
Connection error
Y
N
Replace
Compressor
Check
the Harness
N
N
Y
Harness Connection
OK
Check
Comp.
terminal
Y
Harness
failure
- 23 -
Copyright © 2018-2019 SIGNATURE KITCHEN SUITE. All rights reserved. Only training and service purposes.
5. Check the Compressor & Harness
→ Comp Terminal resistance measurement (Power & Common, Save & Common)
→ Check the broken-down insulation : Comp. Save - Earth resistance measurement
Point D
Point A
Multi Tester
Point B
Sa: Save
Po: Power
Co: Common
The resistance can differ by few depending on
the surrounding temperature or operating condition.
Multi Tester
Sa
Mode Resistance
Po
Co
Multi Tester
Check insulation break-down
Multi Tester
Earth
- 24 -
Power() 14 ~17
Save() 20 ~23
FMA102NAMA
Copyright © 2018-2019 SIGNATURE KITCHEN SUITE. All rights reserved. Only training and service purposes.
7. TROUBLE SHOOTING WITH ERROR DISPLAY
7-1. Error Code
18 Wine 24 Wine Failure Details
1
2
3
4 Abnormal Wi-Fi E Od E Od
5
6
7
Abnormal Internal Temp. Sensor
Abnormal Defrost Sensor
Abnormal Ambient Sensor
Abnormal Internal Fan
Motor
Abnormal Condenser
Fan Motor
Abnormal Communication
ES1/ES2 ES1/ES2/ES3
Ed1/Ed2 Ed1/Ed2/Ed3 Defrost Sensor Short or Open Circuit
E rt E rt
EF1/EF2 EF1/EF2/EF3
E CF E CF
E CO E CO
Internal Temp. Sensor Short or Open Circuit
Ambient Sensor Short or Open Circuit
Communication Short or Open Circuit
(Display ↔ Wi-Fi Module)
There No Signal Of BLDC Fan Motor More Then 65 Seconds In Operation Of Fan Motor (BLDC Motor Connection, Drive IC Or TR Defect)
Communication Short ior Open
Circuit (Display ↔ Main PCB)
18 Wine
24 Wine
- 25 -
Copyright © 2018-2019 SIGNATURE KITCHEN SUITE. All rights reserved. Only training and service purposes.
Loading...
+ 57 hidden pages