LG SJ122CD, SJ182CD Owner's Manual

website http://www.lgservice.com

LG

LG

Room Air Conditioner

INSTALLATION MANUAL

IMPORTANT

Please read this instruction manual completely before installing the product.

When the power cord is damaged, replacement should be performed by authorized personnel only.

Installation work must be performed in accordance with the national wiring standards by authorized personnel only.

Please retain this installation manual for future reference after reading it thoroughly.

<![if ! IE]>

<![endif]>ESPAÑOL ENGLISH

Room Air Conditioner Installation Manual

TABLE OF CONTENTS

Installation

Required Parts

Requirements

Safety Precautions............................

3

Introduction ........................................

6

Symbols used in this manual..........

6

Features ...........................................

6

Installation ..........................................

7

Installation parts...............................

7

Installation tools ...............................

7

Installation map................................

8

Selecting the best location .............

9

Piping length and elevation...........

10

Fixing installation plate..................

11

Drilling a hole in the wall ...............

11

Flaring work ...................................

12

Connecting the piping ..................

13

Connecting the cables ..................

19

Checking the drainage ..................

21

Forming the piping.........................

22

Air purging......................................

23

Test running ...................................

25

Four type "A" screws & plastic anchors

Connecting cable

Installation guide map

Pipes: Gas side

Liquid side

Insulation materials

Additional drain pipe

(Outer diameter ..............15.5mm)

Two type "B" screws

Required Tools

Level gauge

Screw driver

Electric drill

Hole core drill(ø70mm)

Horizontal meter

Flaring tool set

Specified torque wrenches 1.8kg.m, 4.2kg.m, 5.5kg.m, 6.6kg.m

(different depending on model No.)

Spanner ........................Half union

A glass of water

Screw driver

Hexagonal wrench(4mm)

Gas-leak detector

Vacuum pump

Gauge manifold

Owner's manual

Thermometer

Remote control holder

2 Room Air Conditioner

Safety Precautions

Safety Precautions

or other people and property damage, the following instructions

the air conditioner.

specified here as they include important items related to safety. instruction will cause harm or damage. The seriousness is

.

indicates the possibility of death or serious injury.

indicates the possibility of injury or damage to properties only.

used in this manual are as shown below.

Be sure not to do.

Be sure to follow the instruction.

<![if ! IE]>

<![endif]>ENGLISH

Always perform grounding.

Otherwise, it may cause electrical shock.

Securely attach the electrical part cover to the indoor unit and the service panel to the outdoor unit.

Don’t use a power cord, a plug or a loose socket which is damaged.

Otherwise, it may cause a fire or electrical shock.

For installation of the product, always contact the service center or a professional installation agency.

Otherwise, it may cause a fire, electrical shock, explosion or injury.

Always install an air leakage

Do not keep or use

breaker and a dedicated

flammable gases or

switching board.

combustibles near the air

 

conditioner.

If the electrical part cover of the indoor unit and the service

No installation may cause a fire and electrical shock.

Otherwise, it may cause a fire or the failure of product.

Ensure that an installation frame of the outdoor unit is not damaged due to use for a long time.

Do not disassemble or repair the product randomly.

• It may cause injury or an accident.

• It will cause a fire or electrical shock.

Installation Manual 3

Do not install the product at a place that ther is concern of falling down.

injury.

Use caution when unpacking and installing.

• Sharp edges may cause injury.

Operation

Do not share the outlet with other appliances.

It will cause an electric shock

Take care so that the power cord may not be pulled during operation.

Otherwise, it may cause a fire or electrical shock.

Do not use the damaged power cord.

Otherwise, it may cause a fire or electrical shock.

Unplug the unit if strange sounds, smell, or smoke comes from it.

Otherwise, it may electrical shock

Do not modify or extend the power cord randomly.

Otherwise, it may cause a fire or electrical shock.

Keep the flames away.

Do not use the near the heating

• Otherwise, it and electrical

Hold the plug when taking it

• It may cause and damage.

shock.

Do not step on the indoor/outdoor unit and do not put anything on it.

It may cause an injury through dropping of the unit or falling down.

Do not place a heavy object on the power cord.

• Otherwise, it may cause a fire or electrical

When the product is submerged into water, always contact the service center.

Otherwise, it may cause a fire or electrical shock.

Take care so that children may not step on the outdoor unit.

Otherwise, children may be seriously injured due to falling down.

4 Room Air Conditioner

Safety Precautions

Installation

Install the drain hose to ensure that drain can be securely done.

• Otherwise, it may cause water leakage.

Install the product so that the noise or hot wind from the outdoor unit may not cause any damage to the neighbors.

Otherwise, it may cause dispute with the neighbors.

Always inspect gas leakage after the

Keep level parallel in installing the product.

installation and repair of product.

 

• Otherwise, it may cause the failure of product.

• Otherwise, it may cause vibration or water

 

leakage.

Operation

Avoid excessive cooling and perform ventilation sometimes.

• Otherwise, it may do harm to your health.

Use a soft cloth to clean. Do not use wax, thinner, or a strong detergent.

The appearance of the air conditioner may deteriorate, change color, or develop surface flaws.

Do not use an appliance for special purposes

Do not place obstacles around the flow inlet

such as preserving animals vegetables,

or outlet.

precision machine, or art articles.

 

• Otherwise, it may damage your properties.

• Otherwise, it may cause the failure of appliance

 

or an accident.

<![if ! IE]>

<![endif]>ENGLISH

Installation Manual 5

Introduction

Introduction

SymbolsusedinthisManual

This symbol alerts you to the risk of electric shock.

This symbol alerts you to hazards that may cause harm to the air conditioner.

NOTICE This symbol indicates special notes.

Features

Air Inlet

Front Panel

Air Filter

Signal Receptor

Air Intake Vents

Air Intake Vents

 

Connecting

 

 

 

 

Connecting

 

Wires

 

 

 

 

Wires

 

 

Air Outlet Vents

Piping

 

Piping

 

Drain Hose

 

 

 

Drain Hose

 

 

 

 

Base Plate

Air Outlet Vents

Base Plate

 

 

6 Room Air Conditioner

Installation

Read carefully, and then follow step by step.

InstallationParts

Type 1

Type 2

Installation plate

Installation plate

Type "B" screw

Type "B" screw

Type "A" screw (6 EA)

Type "A" screw (8 EA)

Remote control holder

Remote control holder

Installation

<![if ! IE]>

<![endif]>ENGLISH

Installation Tools

Figure

Name

Figure

Name

 

Screw driver

 

Ohmmeter

 

Electric drill

 

Hexagonal wrench

 

Measuring tape, Knife

 

Ammeter

 

Hole core drill

 

Gas-leak detector

 

Spanner

 

Thermometer,

 

 

Horizontal meter

 

 

 

 

Torque wrench

 

Flaring tool set

Installation Manual 7

Installation

InstallationMap

NOTICE

Installation parts you should purchase.

 

Installation plate

 

Sleeve

 

Bushing-Sleeve

 

Putty(Gum Type Sealer)

 

Bend the pipe as closely

 

on the wall as possible,

 

but be careful that it

Air Discarge

doesn't break.

 

Vertical Air deflector

 

Operation Indication Lamps/

Vinyl tape (Wide)

Signal Receptor

 

• Apply after carrying out a

Forced Operation Button

drainage test.

 

• To carry out the drainage

Saddle

test, remove the air filters

and pour water into the heat

 

exchanger.

Air Inlet Vents

Air Outlet Vents

Base Plate

Gas side piping (Optional Parts)

Liquid side piping (Optional Parts)

Additional drain pipe

Vinyl tape (Narrow) Drain Hose

Connecting cable (Optional Parts)

8 Room Air Conditioner

Installation

SelectthebestLocation

Indoor unit

1.Do not have any heat or steam near the unit.

2.Select a place where there are no obstacles in front of the unit.

3.Make sure that condensation drainage can be conveniently routed away.

4.Do not install near a doorway.

5.Ensure that the interval between a wall and the left (or right) of the unit is more than 10cm. The unit should be installed as high as possible on the wall, allowing a minimum of 20cm from ceiling.

More than

 

<![if ! IE]>

<![endif]>ENGLISH

 

 

10cm

20cm

 

 

 

 

More than

 

 

10cm

 

More

 

 

6.Use a stud finder to locate studs to prevent unnecessary damage to the wall.

Install the indoor unit on the wall where the height from the floor is more than 2.3 meters.

Outdoor unit

1.If an awning is built over the unit to prevent direct sunlight or rain exposure, make sure that heat radiation from the condenser is not

restricted.

 

More than 60cm

2. Ensure that the space around the back and

More than 30cm

More than 30cm

sides is more than 30cm. The front of the unit

 

 

should have more than 70cm of space.

 

 

3. Do not place animals and plants in the path

 

 

of the warm air.

More than 70cm

More

4. Take the weight of the air conditioner into

than 60cm

 

 

 

account and select a place where noise and

 

 

vibration are minimum.

 

 

5.Select a place where the warm air and noise from the air conditioner do not disturb neighbors.

Installation Manual 9

Installation

PipingLengthandElevation

Capacity

Pipe Size

Standard

Max.

Max.

Additional

(Btu/h)

GAS

LIQUID

Length (m)

Elevation B (m)

Length A (m)

Refrigerant (g/m)

7k, 8k, 9k

3/8"

1/4"

7.5

7

15

20

11k, 12k, 14k

1/2"

1/4"

7.5

7

15

20

 

1/2"

1/4"

7.5

15

30

20

18k, 24k, 26k

5/8"

1/4"

7.5

15

30

20

 

5/8"

3/8"

7.5

15

30

30

Indoor unit

 

 

Outdoor unit

 

 

 

 

 

 

Outdoor unit

 

 

 

 

 

 

 

 

 

A

Oil trap

 

 

 

 

 

 

 

Outdoor unit

Indoor unit

B

Indoor

 

 

 

 

 

 

B

 

 

 

 

 

 

 

 

 

 

If piping length is more than 5m

Capacity is based on standard length and maximum allowance length is on the basis of reliability. Oil trap should be installed every 5~7 meters.

10 Room Air Conditioner

Installation

FixingInstallationPlate

The wall you select should be strong and solid enough to prevent vibration

1.Mount the installation plate on the wall with type "A" screws. If mounting the unit on a

concrete wall, use anchor bolts.

Mount the installation plate horizontally by aligning the centerline using a level.

Chassis

Hook

Type “A”

<Type 1>

<![if ! IE]>

<![endif]>ENGLISH

2.Measure the wall and mark the centerline. It is also important to use caution concerning the location of the installation plate-routing of the wiring to power outlets is through the walls typically. Drilling the hole through the wall for piping connections must be done safely.

CHASSIS

 

Distance (mm)

 

(Grade)

 

 

 

 

A

B

C

D

 

S4

55

105

65

105

SE

70

110

90

110

S5/S8

100

122

240

122

 

 

 

 

 

<Type 1>

Installation Plate

Chassis

Hook

Type “A”

<Type 2>

 

 

 

D

 

Installation plate

B

 

 

 

 

Ø70mm

C

<Type 1>

A

Ø70mm

 

Left rear piping

Right rear piping

 

 

Installation plate

 

Ø70mm

 

Ø70mm

133mm

<Type 2>

100mm

Left rear piping

Right rear piping

 

DrillaHoleintheWall

• Drill the piping hole with a ø 70mm hole core

 

WALL

 

 

drill. Drill the piping hole at either the right or

 

 

 

Indoor

Outdoor

 

the left with the hole slightly slanted to the

 

outdoor side.

 

 

 

 

 

 

<![if ! IE]>

<![endif]>5-7mm

<![if ! IE]>

<![endif]>(3/16"~5/16")

 

 

 

Installation Manual

11

Installation

Flaring Work

Main cause for gas leakage is due to defect in flaring work. Carry out correct flaring work in the following procedure.

Cut the pipes and the cable.

1.Use the piping kit accessory or the pipes purchased locally.

2.Measure the distance between the indoor and the outdoor unit.

3.Cut the pipes a little longer than measured distance.

4.Cut the cable 1.5m longer than the pipe length.

Burrs removal

1.Completely remove all burrs from the cut cross section of pipe/tube.

2.Put the end of the copper tube/pipe in a downward direction as you remove burrs in order to avoid dropping burrs into the tubing.

Copper

 

Slanted

Uneven Rough

pipe

90°

 

 

Pipe

 

 

 

Reamer

Point down

Putting nut on

Remove flare nuts attached to indoor and outdoor unit, then put them on pipe/tube having completed burr removal.

(not possible to put them on after flaring work)

Flaring work

Flare nut

Copper tube

1. Firmly hold copper pipe in a die in the dimension

 

 

 

shown in the table below.

 

<![if ! IE]>

<![endif]>"A"

 

Handle

2. Carry out flaring work with the flaring tool.

 

Bar

 

 

 

Bar

 

Yoke

Outside diameter

A

 

 

 

 

Cone

mm

inch

mm

 

 

 

 

 

Ø6.35

1/4"

1.1~1.3

Copper pipe

 

Ø9.52

3/8"

1.5~1.7

 

 

 

 

Ø12.7

1/2"

1.6~1.8

 

Clamp handle

Red arrow mark

Ø15.88

5/8"

1.6~1.8

 

 

 

 

 

Ø19.05

3/4"

1.9~2.1

 

 

 

12 Room Air Conditioner

 

 

 

Installation

 

Check

 

 

 

 

1. Compare the flared work with the figure by.

Smooth all round

 

 

 

2. If a flared section is defective, cut it off and

Inside is shiny without scratches

<![if ! IE]>

<![endif]>ENGLISH

Inclined

Surface

Cracked Uneven

do flaring work again.

 

= Improper flaring =

 

 

 

 

 

Even length

damaged

thickness

 

 

 

 

 

 

all round

 

 

 

ConnectingthePiping

Indoor

1.Prepare the indoor unit's piping and drain hose for installation through the wall.

2.Remove the plastic tubing retainer(see the

illustration by) and pull the tubing and drain hose away from chassis.

3.Replace only the plastic tubing holder 1, not the holder 2 in the original position.

For right rear piping

1.Route the indoor tubing and the drain hose in the direction of rear right.

2.Insert the connecting cable into the indoor unit from the outdoor unit through the piping hole.

Do not connect the cable to the indoor unit.

Make a small loop with the cable for easy connection later.

Drain hose

3.Tape the tubing, drain hose, and the connecting cable. Be sure that the drain hose is located at the lowest side of the bundle. Locating at the uper side can cause drain pan to overflow inside the unit.

If the drain hose is routed inside the room, insulate the hose with an insulation material* so that dripping from "sweating"(condensation) will not damage furniture or floors.

*Foamed polyethylene or equivalent is recommended.

Tape

Connecting

pipe

Drain hose

Connecting cable

Installation Manual 13

Installation

4.Indoor unit installation

Hook the indoor unit onto the upper portion of the installation plate.(Engage the two hooks of the rear top of the indoor unit with the upper edge of the installation plate.) Ensure that the hooks are properly seated on the installation plate by moving it left and right.

Press the lower left and right sides of the unit against the installation plate until the hooks engage into their slots(clicking sound).

Connecting the piping to the indoor unit and drain hose to drain pipe.

1.Align the center of the pipes and sufficiently tighten the flare nut by hand.

2.Tighten the flare nut with a wrench.

Outside diameter

Torque

 

 

 

mm

inch

kgf.m

Ø6.35

1/4"

1.8~2.5

Ø9.52

3/8"

3.4~4.2

Ø12.7

1/2"

5.5~6.6

Ø15.88

5/8"

6.3~8.2

3.When extending the drain hose at the indoor unit, install the drain pipe.

Wrap the insulation material around the connecting portion.

1.Overlap the connection pipe insulation material and the indoor unit pipe insulation material. Bind them together with vinyl tape so that there may be no gap.

2.Wrap the area which accommodates the rear piping housing section with vinyl tape.

3.Bundle the piping and drain hose together by wrapping them with vinyl tape for enough to cover where they fit into the rear piping housing section.

Connecting

cable

Drain hose

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Indoor unit tubing

Flare nut Pipes

 

 

 

 

 

 

 

 

 

 

Open-end wrench (fixed)

Flare nut

Wrench

Connection pipe

Indoor unit tubing

Drain pipe

Indoor unit drain hose

Adhesive Vinyl tape(narrow)

Plastic bands Insulation material

Connection pipe

Indoor unit pipe

Vinyl tape (wide)

Wrap with vinyl tape

Connecting cable

Pipe

Vinyl tape(narrow)

Wrap with vinyl tape

Pipe

Vinyl tape(wide)

Drain hose

14 Room Air Conditioner

 

 

 

Installation

For left rear piping

 

 

1.

Route the indoor tubing and the drain hose to

 

 

 

the required piping hole position.

1

2

2.

Insert the piping, drain hose, and the

 

Connecting

 

cable

 

connecting cable into the piping hole.

 

 

 

 

3.

Insert the connecting cable into the indoor unit.

 

Drain pipe

 

• Don't connect the cable to the indoor unit.

 

 

 

 

 

• Make a small loop with the cable for easy

 

 

 

connection later.

 

 

4. Tape the drain hose and the connecting

 

 

cables.

<![if ! IE]>

<![endif]>ENGLISH

5.Indoor unit installation

Hang the indoor unit from the hooks at the top of the installation plate.

Insert the spacer etc. between the indoor unit and the installation plate and separate the bottom of the indoor unit from the wall.

Connecting the piping to the indoor unit and the drain hose to drain pipe.

1.Align the center of the pipes and sufficiently tighten the flare nut by hand.

2.Tighten the flare nut with a wrench.

Outside diameter

Torque

 

 

 

mm

inch

kgf.m

Ø6.35

1/4"

1.8~2.5

Ø9.52

3/8"

3.4~4.2

Ø12.7

1/2"

5.5~6.6

Ø15.88

5/8"

6.3~8.2

 

 

 

3.When extending the drain hose at the indoor unit, install the drain pipe.

Indoor unit

Spacer

Installation plate 8cm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Indoor unit tubing

Flare nut Pipes

 

 

 

 

 

 

 

 

 

 

Open-end wrench (fixed)

Flare nut

Wrench

Connection pipe

Indoor unit tubing

Drain hose

Indoor unit drain hose

Adhesive Vinyl tape (narrow)

Installation Manual 15

Installation

Wrap the insulation material around the connecting portion.

1.Overlap the connection pipe heat insulation and the indoor unit pipe heat insulation material. Bind them together with vinyl tape so that there may be no gap.

2.Wrap the area which accommodates the rear piping housing section with vinyl tape.

3.Bundle the piping and drain hose together by wrapping them with cloth tape over the range within which they fit into the rear piping housing section.

Reroute the pipings and the drain hose across the back of the chassis.

Indoor unit installation

1.Remove the spacer.

2.Ensure that the hooks are properly seated on the installation plate by moving it left and right.

3.Press the lower left and right sides of the unit against the installation plate until the hooks engage into their slots(clicking sound).

Plastic bands Insulation material

Connection

Indoor

unit piping

pipe

 

Vinyl tape

Wrap with vinyl tape

(wide)

 

 

Pipe

 

Vinyl tape(narrow)

Connecting cable

 

Pipe

Drain hose

Vinyl tape(narrow)

Wrap with

vinyl tape(wide)

Piping for passage through piping hole

Connecting

cable

Drain hose

16 Room Air Conditioner

LG SJ122CD, SJ182CD Owner's Manual

Installation Information. For left piping. Follow the instruction below.

Good case

• Press on the upper side of clamp and unfold the tubing to downward slowly.

Bad case

• Following bending type from right to left may cause damage to the tubing.

Installation

<![if ! IE]>

<![endif]>ENGLISH

Installation Manual 17