• Please read this installation manual completely before installing the product.
• Installation work must be performed in accordance with the national wiring standards by authorized personnel only.
• Please retain this installation manual for future reference after reading it thoroughly.
TYPE : Refrigerant Leak Detector MODEL : PLD-RNV0S
P/NO : MFL68102202
ENGLISH
ITALIANO ESPAÑOL FRANÇAIS DEUTSCH
ΕΛΛΗΝΙΚΆ
ČEŠTINA
NEDERLANDS
POLSKI
LIMBA ROMÂNĂ
Refrigerant Leak Detector
Installation Manual
TABLE OF CONTENTS
1. Safety Precautions .........................................................................................................3
2. Components....................................................................................................................5
3. Part Functions.................................................................................................................6
4. Part Specification ...........................................................................................................7
5. Refrigerant Leak Detector..............................................................................................8
Main Features...................................................................................................................8
Detector Alarm..................................................................................................................9
6. How to Install ................................................................................................................10
7. Installation Order ..........................................................................................................11
8. Test Run.........................................................................................................................14
Pre-check .......................................................................................................................14
Checking the refrigerant leak detector setting - Wired Remote Control .........................14
Checking the refrigerant leak detector setting - Wireless Remote Control.....................15
Leak Check for Refrigerant Leak Detector .....................................................................16
9. Checkup before Reporting Trouble.............................................................................18
2
Refrigerant Leak Detector
Safety Precautions
1. Safety Precautions
To prevent injury to the user or other people and property damage, the following instructions must be followed.
n Be sure to read before installing the unit. n Be sure to observe the cautions specified here as they include important items related to
safety.
n Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is
classified by the following indications.
n Meanings of symbols used in this manual are as shown below.
This symbol indicates the possibility of death or serious injury.
This symbol indicates the possibility of injury or damage to properties only.
n When Installing
Be sure not to do.
Be sure to follow the instruction.
To install a product, inquire with a service center or an technician.
• Failure to do so may result in fire, electric shock, or injury.
To reinstall the product, please inquire with a serv­ice center or technician.
• Failure to do so may result in fire, electric shock, or injury.
Do not deliberately disas­semble, repair, or modify the product.
• This may be a cause of fire or electric shock.
Installation Manual 3
ENGLISH
n When Using
Do not place the product near fire.
• Doing so may start a fire.
Do not spill water on the product.
• Spilling water on this product may result in electric shock or damage to the product.
Do not cause an impact with the product or kick it with your foot.
• The impact to the product may cause a product defect.
Safety Precautions
4
Refrigerant Leak Detector
Do not put a sharp and pointed object, etc. into a crack or gap.
• Doing so may result in electric shock or damage to the product.
Do not create an impact with a sharp and pointed object, etc.
• The damaged part may cause product damage.
Do not touch with a wet hand or pull a connecting cable.
• Product defect and electrical shock may result.
To install an air conditioner in a closed space, you must ensure ventilation measures.
• If the concentration becomes high due to a refrigerant leak, you may suffocate due to a lack of oxygen.
Do not use the product other than for its desig­nated purpose.
• Product defects may result.
Installation Manual 5
Components
ENGLISH
2. Components
User/Installation Manual 6 Set Screws Connecting Cable
Sensor Protective Cover Sensor
Part Functions
6
Refrigerant Leak Detector
3. Part Functions
Sensor
- LED: Displays the state of the sensor.
- Detecting Part : Detects the concentration of refrigerant R410A in the air.
- Connecting Cable Mating Section : Combines a cable connected to an indoor unit.
Connecting Cable
- Indoor Unit Connecting Part : Connects to the PCB of the indoor unit.
- Sensor Connecting Part : Connects to the sensor connecting cable mating section.
* Due to the different sizes of the connecting
parts. the parts are not connected in reverse.
Sensor Protective Cover
- Connecting Cable Fixing Parts: Fix connect­ing cables to align wires.
- Sensor Fixing Parts: Guide to fix the sensor on the sensor protective case (backplate).
- LED Displaying Part: Possible to check the LED that displays the state of the internal sensor.
Sensor
Connecting Part
Indoor Unit
Connecting Part
LED
Displaying Part
Connecting Cable Fixing Part
Sensor Fixing Part
LED
Detecting Part
Connecting Cable Mating Section
Part Specification
4. Part Specification
Sensor
Installation Manual 7
ENGLISH
Item Unit Spec.
Rated Voltage V DC 5.0 ± 5 %
Dimension (WⅹHⅹD) mm 31 x 44 x 20
Weight g 22
Refrigerant - R410A
Detected Concentration ppm 0/6000, Alarm off/on
Operating Temperature Range °C -10 ~ 50
Preserved Temperature Range °C -40 ~ 60
Average Power Consumption mA 35
Connecting Cable
Item Unit Spec.
Type - Housing
Length m 10
Sensor Protective Cover
Item Unit Spec.
Dimension of Front Plate (WⅹHⅹD) mm 80ⅹ110ⅹ44.6
Dimension of Backplate (WⅹHⅹD) mm 80ⅹ110ⅹ6.5