Please read this installation manual completely before installing the product.
Installation work must be performed in accordance with the national wiring
standards by authorized personnel only.
Please retain this installation manual for future reference after reading it
thoroughly.
BACnet Touch (AC Smart BACnet)
PBACNA000
P/NO : MFL69023101
EXPLANATORY NOTES
i
EXPLANATORY NOTES
Copyrights
The contents of this AC Smart BACnet Installation and User Manual are protected by international
copyright laws, and the Computer Program Protection Act. The contents of the Installation/User
Manaual and the programs mentioned herein may only be used under license from LG Electronics in
strict adherence to the user agreement.
You may not reproduce or distribute, by any means, copies of this Installation and User Manual, or
any part of it, without prior approval from LG Electronics.
AC Smart BACnet is a registered trademark of LG Electronics. All other products and company
names are trademarks of their respective owners and are used for illustrative purposes only.
ENGLISH
ii
EXPLANATORY NOTES
Product Features
ENGLISH
Convenience
• Auto-changeover
Automatically switches the indoor unit into the correct mode to optimize space comfort.
• Web access
Allows distributed control from a remote location.
• Visual and e-mail alarm notification
Immediately indicates when a system is not operating at optimal conditions.
• Visual Navigation
Allows for accessing unit data by navigating uploaded floorplans.
Energy Savings
• Scheduling
Conditions the space only when necessary.
• Setpoint Range Limit
Prevents the setpoint from being set to extremes that can result in overcooling or overheating
of the space.
• Remote Controller Lock
Prevents users from changing indoor unit operation.
• Setback
Allows indoor units to be shut off during unoccupied periods with an override feature to keep
interior temperatures from reaching extremes.
• Time Limit
Allows a unit to be turned on during unoccupied times and automatically shut down after a
specified amount of run time.
• Peak/Demand Control
Allows for electronically limiting power usage.
Integration
• Interlocking
Allows interlocked operation between devices or between digital inputs and outputs on the AC
Smart and devices.
EXPLANATORY NOTES
How to Use This Guide
Please read from beginning to end this User Manual before using AC Smart BACnet. Store this guide
so that is also easily accessible.
Notations Used In This Guide
• Control buttons displayed within the system are marked by boldface text in square brackets ([ ]).
Example: [OK], [Save]
• Option titles displayed in the program are marked by boldface text.
Example: Start, Programs
• Keyboard strokes used by the system are marked by boldface text in angle brackets (< >).
Example: <Esc>
iii
ENGLISH
iv
ENGLISH
MEMO
TABLE OF CONTENTS
v
TABLE OF CONTENTS
SAFETY
1
PRECAUTIONS
PREPARATION
7
7 AC Smart BACnet Overview
7 Components
8 Product Specifications
9 Features and Functions
10 Installation and Configuration
10 – Installation
19 – Configure Remote Shutdown Feature
20 Information Input Method
FUNCTIONAL
25
SPECIFICATIONS AC
Smart BACnet
NOTES
84
84 BIBBs
91 Multi – state Input Object Type
93 AC Smart BACnet Error Response
Table
Troubleshoot
95
95 Control Codes
ENGLISH
STARTING
21
21 Turning on/off the screen
21 – Turning on the screen
21 – Turning off the screen
22 Rebooting
22 Login and logout
LG’S AC Smart BACnet
23
AGREEMENT
95 Error Codes
95 – Indoor Device, ERV or ERV DX,
AWHP(Hydro kit), AHU error
97 – Outdoor Unit Errors
99 – MultiV 20 Hp, 30 Hp, 40 Hp, error
101 – Super Errors
102 – Central Controller Errors
103 Pre-Tech Support Checklist
103 OPEN SOURCE SOFTWARE
NOTICE
vi
ENGLISH
MEMO
SAFETY PRECAUTIONS
1
SAFETY PRECAUTIONS
• This product must be installed by an installation professional from an LG authorized service
center.
• Any issues stemming from an installation by an unauthorized person is the responsibility of
the user and will not be covered by warranty.
• The following safety precautions are to prevent any unforeseen dangers or damage.
• This product has been designed for business use, or for areas outside the home, and has
passed the Electromagnetic Interference Test.
WARNING
It can result in serious injury or death when the directions are ignored.
CAUTION
It can result in minor injury or product damage when the directions are ignored.
WARNING
Installation
y To reinstall the product, please contact the dealer from where you purchased the
product, or a service center for reinstallation service.
- Installation of the product by an unauthorized person may result in fire, electric shock, explo
sion, injur y, or a malfunctioning of the product.
ENGLISH
-
y Do not twist or damage the power cord.
- It may cause fire or electric shock.
y For electrical work, please contact the dealer from where you purchased the product , or
a service center.
- Disassembly or repair by an unauthorized person may result in fire or electric shock.
y Install the product in an area shielded from rain.
- If water gets into the product, it may malfunction.
y Do not install the product in a humid area.
- If the product is damp, it may malfunction.
y For installation of the product, please contact the dealer from where you purchased the
product, or a service center.
- Installation of the product by an unauthorized person may result in fire, electric shock, explo
sion, injur y, or a malfunctioning of the product.
-
SAFETY PRECAUTIONS
2
ENGLISH
y For electrical work, please have an electrician do the work based on the installation
manual and specified circuit diagram.
- Using an unsuitable cord, or having a non-professional work on the electricals may result in fire
or electrical shock.
y Do not place the product near a fire source.
- It may result in the product catching fire.
y If the product is installed in a hospital or a communication base station, provide
sufficient protective equipment against electrical noise.
- The product may malfunction or other products may work abnormally.
y Securely install the product.
- If the product is not secured during installation, it may fall or malfunction.
y Read the manual thoroughly to correctly install the product.
- If not, an incorrect installation may cause fire or electric shock.
y When wiring the product, do not use a non-standard cable, nor extend the cable
excessively.
- It may cause a fire or electric shock.
y Securely install the power cord and communication cable.
- An unsecure installation may result in a fire or electric shock.
y Do not connect the power cord to the communication terminal.
- It may cause a fire, electric shock, or a product malfunction.
y Do not install the product in an area near combustible gas.
- It may result in fire, electric shock, explosion, injur y, or a malfunctioning of the product.
Use
y Do not place a heavy object on the power cord.
- It may cause a fire or electric shock.
y Do not change or extend the power cord arbitrarily.
- It may cause a fire or electric shock.
y Use the cord specific to the product.
- Using an unauthorized non-standard cord may result in a fire or electric shock.
y Do not use a heat device near the power cord.
- It may cause a fire or electric shock.
y Ensure that water never gets into the product.
- It can result in an electric shock, or the product may malfunction.
y Do not place any container with liquid on the product.
- The product may malfunction.
SAFETY PRECAUTIONS
y Do not touch the product with wet hands.
- It may cause a fire or electric shock.
y Use standard components.
- Use of an unauthorized product may result in fire, electric shock, explosion, injury, or a malfunc
tioning of the product.
y If the product has been submerged in water, you should contact a ser vice center.
- It may cause a fire or electric shock.
y Do not shock the product.
- The product may malfunction.
y Do not store or use any combustible gas or flammable substances near the product.
- It may cause a fire, or a product malfunction.
y Do not disassemble, repair, or revamp the product arbitrarily.
- It may cause a fire or electric shock.
y Children and the elderly should use the product under the supervision of a guardian.
- Carelessness may cause an accident, or the product to malfunction.
y The guardian should prevent children from accessing the product.
- The product may be damaged or it may fall, causing injury to children.
3
ENGLISH
-
y Keep in mind the operating temperature range specified in the manual.
if there is no operating temperature range in the manual, use the product between 0 and
40 °C (32 and 104 °F).
- If the product is used outside this range, the product may be severely damaged.
y Do not press the switch or button with a sharp object.
- It can result in an electric shock, or the product may malfunction.
y Do not wire the product while it is turned on.
- It may cause a fire or electric shock.
y If the product sounds or smells different, stop using the product.
- It may cause a fire or electric shock.
y Do not place a heavy object on the product.
- The product may malfunction.
y Do not spray water on the product, or clean it with a water-soaked cloth.
- It may cause a fire or electric shock.
y Do not use the product for the preservation of animals and plants, precision
instruments, art pieces, or for other special purposes.
- It may cause property damage.
y Dispose the packing material safely.
- The packing material may result in personal injuries.
SAFETY PRECAUTIONS
4
ENGLISH
Installation
CAUTION
y Securely install the product in an area where the weight of the product can be supported.
- The product may fall and be destroyed.
y Do not use the product where there is oil, steam, or sulfuric gas.
- It may effect the product's performance, or damage it.
y Check the rated power capacity.
- It may cause a fire, or a product malfunction.
y Use the adapter provided with the product or power from a class 2 24 V~ transformer,
depending on model.
- If a non-standard adapter is used, the product may malfunction. The adaptor is not provided
with the AC Smart BACnet package sold in the U.S.
y Be careful not to drop or damage the product when moving it.
- The product may malfunction or the person may sustain an injury.
y Ensure that the cord is connected securely to prevent dew, water, or insects from getting
into the product.
- If a foreign substance gets inside, it may cause an electric shock or the product may malfunc
tion.
-
Use
y Clean the product with a soft cloth, but not with a solvent-based detergent.
- The use of a solvent-based detergent may cause a fire or deform the product.
y Do not touch the panel using a pointy or sharp object.
- It can result in an electric shock, or the product may malfunction.
y Do not let the product come into contact with a metal substance.
- The product may malfunction.
y When sterilizing or disinfecting, stop using the product.
- The product may work abnormally.
y Do not touch inside the product.
- The product may malfunction.
y Check the condition of the product af ter using the product for an extended period of
time.
- If the product is used for an extended period of time, the product's condition may be worsen,
causing injury to the user.
y Do not leave the product near a flower base, water bottle, or any other liquids.
- It may cause a fire or electric shock.
SAFETY PRECAUTIONS
5
ENGLISH
yTransformer selection:
-Select an insulating product that complies with IEC61558-2-6 and NEC Class 2.
-In addition, consider the combined power consumption of the modules, accessories, and field
devices installed for the selection of an appropriate transformer.Main module current: 24 V~, 850 mA
-Use the provided adaptor when using DC 12 V. The adaptor is not provided with the AC Smart
BACnet package sold in the U.S.
SAFETY PRECAUTIONS
6
Class A device
ENGLISH
NOTES
This equipment has been tested and found to comply with the limits for a Class A digital device,
pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference when
the equipment is operated in a commercial environment.
This equipment generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area is likely to cause harmful
interference in which case the user will be required to correct the interference at his own
expense.
CAUTION
Changes or modifications not expressly approved by the manufacturer responsible for
compliance could void the user’s authority to operate the equipment.
Disposal of your old appliance
1. When this crossed-out wheeled bin symbol is attached to a product it
means the product is covered by the European Directive 2002/96/EC.
2. All electrical and electronic products should be disposed of separately
from the municipal waste stream via designated collection facilities
appointed by the government or the local authorities.
3. The correct disposal of your old appliance will help prevent potential
negative consequences for the environment and human health.
4. For more detailed information about disposal of your old appliance,
please contact your city o!ce, waste disposal service or the shop
where you purchased the product.
PREPARATION
7
PREPARATION
The following provides information on the AC Smart BACnet components, how to install and
configure, and other required information necessary to use the product.
AC Smart BACnet Overview
AC Smart BACnet is a central controller installed in the management office of a building, or in the
administration office of a school, to monitor and operate, via touch screen or Web access, the
indoor units, ERV (ERV: Energy Recovery Ventilator, ERV DX: Direct Expansion Energy Recovery
Ventilator), DI/DOs, DOKITs, AWHPs, AHUs and I/O Modules installed inside the building. AC Smart
BACnet can manage, collectively or individually, the indoor units, ERV, DI/DOs, DOKITs, AWHPs and
AHUs for up to 128 devices. (Or the indoor units, ERV, DI/DOs, DOKITs, AWHPs and AHUs for up to
64 devices and 9 I/O Modules)
Components
The following components are included in the package box. Open the box and verify that all
components are included.
ENGLISH
AC Smar t BACnet
INSTALLATION/OWNER’S MANUAL
AIR
CONDITIONER
Please read this installation manual completely before installing the product.
Installation work must be performed in accordance with the national wiring
standards by authorized personnel only.
Please retain this installation manual for future reference after reading it
thoroughly.
HVAC Touch (BACnet)
PBACNA000
P/NO : MFL69023101
Power Cord
Quick GuidePower AdapterAC Smart BACnet
User's Manual
Power Cord, Power Adaptor and Quick Guide are not provided with the AC Smart BACnet package sold in
the U.S.
ENGLISH
PREPARATION
8
ENGLISH
NOTES
The figures of the components and optionally purchased products shown may differ from the
actual components and products.
Product Specifications
The product specifications for AC Smart BACnet are as follows.
ItemSpecifications
PC IMX515 0 D
CPU
MEMORY 128 x 4 MB (DDR2 SDRAM)
Storage 4GB (INAND FLASH)
LCD 10.2 inch WSVGA (1024 x 600) TFT LCD
Speaker MONO 300 mW
RS485 2 Ports
USB/SD
DI 2 Ports
DO 2 Ports
Touch Screen C-Type Touch Panel
Button Key
POWER DC 12 V (3.33 A), 24 V~
OS Linux
y ARM Cor tex A8™ core
y 800 MHz
y MICRO USB 1EA (for external USB memory)
y MINI USB 1EA (for service)
y SD Card 1EA
Less than 9 seconds (LCD POWER ON/OFF), 10 seconds (SYSTEM
RESET)
Features and Functions
The features and functions of AC Smart BACnet are as follows.
①③②⑥④⑤
PREPARATION
9
ENGLISH
<Front>
⑦⑧
⑪⑩⑨
<Bottom>
NumberItemDescription
①
②
③
④
⑤
⑥
⑦
⑧
⑨
⑩
⑪
Touch Screen
SD Memor y Slot
(for service)
DO Port 2CH DO por t
DI Port 2CH DI port
485 Port 2CH 485 port (CH1: AHU, CH2: devices other than AHU)
DC 12 V Input Port DC 12 V power input port
LAN Port L AN cable port for Ethernet connection (100Mbps/10Mbps)
24 V~ Input Port 24 V~ power input port
Micro USB Port
Mini USB Por t
(for service)
Power ON/OFF
y 10.2 inch LCD control panel
y AC Smart BACnet control and information display
SD card memory slot for software upgrade
USB 2.0 to connect USB memory sticks storing floor plans,
reports, statistics, etc.
PC port for software upgrade
y Push less than 10 seconds to control AC Smart BACnet LCD
backlight.
y Push 10 seconds or more to reset AC Smart BACnet.
y If you are not going to use AC Smar t BACnet for a long time, it
is recommended that the product be turned off to prolong the
LCD backlight's life.
<Back>
PREPARATION
10
Installation and Configuration
ENGLISH
This chapter explains how to install and configure AC Smar t BACnet.
Installation
To use AC Smart BACnet, build an environment for which AC Smart BACnet can communicate
with devices like the indoor unit, ERV, DI/DO, DOKIT, AWHP, AHU and I/O Module. Use AC Smart
BACnet to register those devices.
AC Smart BACnet should be installed in the following order:
STEP 1. Check the installation environment and configure the device
address.
Check the network configuration against the interfaced devices before installing
AC Smart BACnet and allocate a unique central control address for each
connected device.
STEP 2. Connect BECON devices with AC Smart BACnet.
Use an RS485 cable to connect BECON devices with AC Smart BACnet.
STEP 3. Login and register the devices.
Login to AC Smart BACnet and register those devices that have their address
set.
CAUTION
The installation of AC Smart BACnet must be done by a professional. Be sure to contact a
qualified engineer for the installation. If you have a question or request regarding the installation,
contact an installation professional at an authorized LG service center or LG Electronics.
Check the installation environment and configure the device address
PREPARATION
11
AC Smart BACnet can connect up to 128 devices (including indoor units, ERV, DI/DOs, DOKITs,
AWHPs, AHUs) or 64 devices (including indoor units, ERV, DI/DOs, DOKITs, AWHPs ans AHUs) and
9 I/O Modules.
BACnet protocol is not supported for Modular AHU and I/O module.
The following shows an example of connecting AC Smart BACnet with such devices.
AC Smart BACnet connects with PI485 and uses RS485 to communicate and exchange information.
Allocate unique addresses to those devices (internal units, ERV, DI/DOs, DOKITs, AWHPs, AHUs,
I/O Modules) that will connect with AC Smart BACnet. The addresses are hexadecimal numbers that
can be chosen from 00 to FF.
PREPARATION
12
ENGLISH
Power Distribution
Indicator (PDI)
watt-hour meter
AC Smart BACnet
Outdoor Units
ERV
DI/DO, DOKIT
Configuration
Address: 21
...
AHU
Indoor devices 1
Configuration
Address: 01
Configuration
Address: 11
AWHP
Configuration
Addr ess : 41
Indoor devices 2
Configuration
Address: 02
Configuration
Addr ess: 31
Indoor devices 3
Configuration
Address: 03
NOTES
yThe maximum allowed communication distance guaranteed by LG Electronics is 1 000 m. It
means that the distance between AC Smart BACnet and the farthest device should not exceed
1 000 m. It is recommended that the communication cable use 0.75 mm square or more.
yFor indoor units, ERV, DI/DOs, DOKITs, AWHPs, AHUs and I/O Modules, you cannot allocate
identical addresses among devices of the same type. Allocate different addresses for devices
of the same type. (the indoor unit and DOKIT cannot use the same address.)
yEach device which can be used with PDI must be set to a unique address when connected
with PDI. For further information about the devices can be used with PDI, please refer to the
PDI manual.
yConnecting I/O Module, address setting should not be 00 because 00 is used to Broadcast in
MODBUS communication.
AC Smart BACnet's RS485 connection
PREPARATION
13
An AC Smart BACnet can have up to 128 indoor units. If there are many outdoor units to be
connected, connect them to a bus. If not, AC Smart BACnet may malfunction.
<Good example: RS485 BUS form connection><Bad example: RS485 STAR form connection>
ENGLISH
NOTES
Maximum node numbers which can be connected to RS485 communication line.
yMulti V
Maximum of 16 nodes can be connected to 1 RS485 line.
yMulti/Single
Maximum of 32 nodes can be connected to 1 RS485 line.
yERV
Maximum of 32 nodes can be connected to 1 RS485 line.
PREPARATION
14
Connect AC Smart BACnet
ENGLISH
You can install AC Smar t BACnet and its cables as follows.
1. Choose a space for AC Smart BACnet.
• Prior to securing AC Smart BACnet, check if the space is suitable for installing
AC Smart BACnet, an RS485 cable, power cord, and an Ethernet cable.
2. Secure the back panel of AC Smar t BACnet to the wall under which the RS485 cable is located.
3. Extend the RS485 cable through the top opening of the back panel.
PREPARATION
AB
AHU
AB
(RS485)
ODU
4. Connect the RS485 cable,which is located behind the AC Smart BACnet, to the RS485 terminal.
CAUTION
The RS485 cable is polarity sensitive, be careful about keeping polarity when connecting the
cables.
15
ENGLISH
5. To use the network functions (email transmission and web control) provided by AC Smart
BACnet, connect an Ethernet cable to the LAN port on the back of AC Smart BACnet.
PREPARATION
16
6. Connect the power.
ENGLISH
• For global models
- On the back of AC Smar t BACnet, connect the power adapter to the power port.
The adaptor is not provided with the AC Smart BACnet package sold in the U.S.
NOTES
You can hang the power cord on the power cord hanger located below the power port.
• For US models
- At the bottom of AC Smart BACnet, connect the power cord to the power port.
NOTES
In some countries, except for the U.S, you can connect the DC 12 V power to the AC
Smart BACnet by using the provided adapter. If necessary, connect the 24 V~ power to
the AC Smart BACnet.
PREPARATION
17
ENGLISH
PREPARATION
18
7. After attaching the hook on the top of the main body to the top of the rear panel installed on the
ENGLISH
wall, please push the top of the main body unit forward for firm attachment.
CAUTION
Secure two points on the bottom of the unit to prevent from falling.
NOTES
Product removal
After removing 2 screws from the bottom of the body, slightly pull the body using the flatblade
screwdriver and lift up the body to remove the product.
8. Connect the power cord of the power adapter to the power plug.
PREPARATION
Configure Remote Shutdown Feature
Based on contact closure of Digital Input 1 the AC Smart BACnet can stop all connected devices
(indoor units, ERV, DOKITs, AWHPs, and AHUs).
A non-voltage contact must be connected to terminals DI-1 to initiate Remote Shutdown as shown
below.
19
ENGLISH
CAUTION
The DI1 port should always be open except when an emergency occurs.