LG PAHCMW000 INSTALLATION INSTRUCTIONS

INSTALLATION MANUAL
AIR
CONDITIONER
MFL62179526
Rev.01_112919
[Representative] LG Electronics Inc. EU Representative : LG Electronics
European Shared Service Center B.V. Krijgsman 1, 1186 DM Amstelveen, The Netherlands
Gyeongsangnam-do, KOREA
www.lg.com
Copyright © 2019 LG Electronics Inc. All Rights Reserved.
Please read this installation manual completely before installing the product.
Installation work must be performed in accordance with the national wiring
standards by authorized personnel only.
Please retain this installation manual for future reference after reading it thoroughly.
WATER COMMUNICATION MODULE
Original instruction
ENGLISH
ITALIANO
ESPAÑOL
FRANÇAIS
DEUTSCH
ΕΛΛΗΝΙΚΆ
NEDERLANDS
PORTUGUÊS
2
SAFETY INSTRUCTIONS
ENGLISH
WARNING
• Installation or repairs made by unqualified persons can result in hazards to you and others.
• Installation must conform with local building codes or, in the absence of local codes.
• The information contained in the manual is intended for use by a qualified service technician
familiar with safety procedures and equipped with the proper tools and test instruments.
• Failure to carefully read and follow all instructions in this manual can result in equipment
malfunction, property damage, personal injury and/or death.
Installation
• Be sure to request to the service center or installation specialty store when installing products.
- It will cause fire or electric shock or explosion or injury.
• Always perform grounding.
- Otherwise, it may cause electrical shock.
• Don’t use a power cord, a plug or a loose socket that is damaged.
- Otherwise, it may cause fire or electrical shock.
• You need to use a safely insulated power supply which follows IEC61558-2-6 and NEC Class2.
- If you do not follow, It may cause fire, electric shock, explosion or injury.
• For installation of the product, always contact the service center or a professional installation
agency.
- Otherwise, it may cause fire, electrical shock, explosion or injury.
Securely attach the electrical part cover to Comm. Module.
- If the electric part cover of Comm. Module is not attached securely, it could result in a fire or
electric shock due to dust, water, etc.
• Always install an air leakage breaker and a dedicated switching board.
- No installation may cause a fire and electrical shock.
• Do not keep or use flammable gases or combustibles near the equipment.
- Otherwise, it may cause a fire or the failure of product.
• Do not install, remove or reinstall the unit by yourself.
- Otherwise, it may cause a fire, electrical shock, explosion or injury.
!
WARNING
This indicates that the failure to follow the instructions can cause serious injury or death.
CAUTION
This indicates that the failure to follow the instructions can cause the minor injury or damage
to the product.
This symbol is displayed to indicate matters and operations that can cause risk.
Read the part with this symbol carefully and follow the instructions in order to avoid risk.
!
!
!
SAFETY INSTRUCTIONS
The following safety guidelines are intended to prevent unforeseen risks or damage from unsafe
or incorrect operation of the appliance.
The guidelines are separated into ‘WARNING’ and ‘CAUTION’ as described below.
SAFETY INSTRUCTIONS
3
ENGLISH
• Do not disassemble or repair the product randomly.
- It will cause a fire or electrical shock.
• Do not install the product in a place where there is the concern of falling down.
- Otherwise, it may result in personal injury.
• Use caution when unpacking and installing.
- Sharp edges may cause injury.
Operation
• Do not share the outlet with other appliances.
- It will cause an electric shock or a fire due to heat generation.
• Do not use the damaged power cord.
- Otherwise, it may cause a fire or electrical shock.
• Do not modify or extend the power cord randomly.
- Otherwise, it may cause a fire or electrical shock.
• Take care so that the power cord may not be pulled during operation.
- Otherwise, it may cause a fire or electrical shock.
• Unplug the unit if strange sounds, smell, or smoke comes from it.
- Otherwise, it may cause electrical shock or a fire.
• Keep flames away.
- Otherwise, may occur a fire.
• Take the power plug out if necessary, holding the head of the plug and do not touch it with wet
hands.
- Otherwise, it may cause a fire or electrical shock.
• Do not use the power cord near the heating tools.
Otherwise, it may cause a fire and electrical shock.
• Do not allow water to run into electrical parts.
- Otherwise, it may cause the failure of machine or electrical shock.
• Hold the plug by the head when taking it out.
- It may cause electric shock and damage.
• Be cautious that water could not enter the product.
- Otherwise, it may cause a fire electrical shock or product damage.
• Do not step on the indoor/outdoor unit and do not put anything on it.
- It may cause an injury through dropping of the unit or falling down.
• Do not place a heavy object on the power cord.
- Otherwise, it may cause a fire or electrical shock.
• When the product is submerged into water, always contact the service center.
- Otherwise, it may cause a fire or electrical shock.
BEFORE INSTALLATION
CAUTION
!
• Don't install or operate the unit in rooms mentioned below.
Where mineral oil, like cutting oil is present.
Where the air contains high levels of salt such as air near the ocean.
Where Sulphur gas is present such as that in areas of hot spring.
In vehicles or vessels.
Where voltage fluctuates a lot such as that in factories.
Where high concentration of vapor spray are present.
Where machines generating electromagnetic waves are present.
Where acidic or alkaline vapor is present.
The option boxes must be installed with entrances downward.
4
BEFORE INSTALLATION
ENGLISH
INSTALLATION SCENE
5
ENGLISH
INSTALLATION SCENE
Schematic Diagram
This module is intended to connect 3rd party plate heat exchanger to LG outdoor unit with the
ability to control water temperature from 3rd party DDC or LG remote controller.
h FS : Flow Switch
h TT : DHW Temperature Transmitter
NOTE
• Installation scene shows a general installation.
• Some items are field supply.
• Installation scene may vary on application.
• Heating wired remote controller is sold separately.
M
FS
TT
3rd Party DDC
Modbus RTU / DI+AI
Refrigerant Side Water Side
DHW
Tank
Water
Communication
Module
LG
Remote
Controller
Heat
Exchanger
6
SPECIFICATION
ENGLISH
SPECIFICATION
Dimension


<Water Communication Module>
PAHCMW000
Components
Water
Communication
Module
Thermistor
(Water In / Water Out /
Pipe In / Pipe Out)
OWNER’S &
INSTALLATION
MANUAL
Sensor Holder & Clip
Shape
Quantity 1 4 (each 5m) 1 4
SUPPLIES
[Unit: mm]
CAUTION
!
• This model requires DC12 V external power supply. (Select an insulating transformer that
complies with IEC61558-2-6 and NEC Class 2.)
• Please check the Product operation range below.
• The Ingress Protection marking for this product restricts installation location.
LG Electronics is not responsible for installation at locations non-compliant to the IP
rating.
Power Supply 12 V DC
Product Operation Range
Ambient Temperature -20 ~ 65 °C DB
Humidity 0~98 % (Non Condensing)
Product Protection Class IP Rating IP20