LG MV-1155SC Installation Manual

INSTALLATION INSTRUCTION MANUAL

MODEL NO.'S 85210

Read and save these installation instructions.

INSTALLATION

INSTRUCTIONS

R

SPACEMASTER

MICROWAVE OVEN

Part No. 3828W5U0269

Printed in Korea

SEARS. CANADA INC., TORONTO, M5B 2B8

YOUR SAFETY FIRST

BEFORE YOU START

Proper installation is the installer's responsibility!

Read the entire manual before you begin. Be sure to follow the installation clearances specified on the model number label. The Model number label is located on the left side for the control panel. See Figure 1.

Model Number Label

Figure 1

BE SURE TO READ THE FOLLOWING SAFETY INSTRUCTIONS:

w WARNING w

FOR YOUR SAFETY:

You will need TWO people to install this oven. It is heavy and could cause personal injury if not handled properly. The dimensions of the oven are as follows:

Height : 16 inches

Width : 29 7/8 inches

Depth : 14 inches

Net Weight : 69 pounds

Avoid Electrical Shock!

Before you drill into the wall, note where electrical outlets are and where electrical wires might be concealed behind the wall. YOU COULD GET AN ELECTRIC SHOCK if you contact electrical wires with your drill bit.

Locate and disconnect the power of any electrical circuits that could be affected by installing this oven.

IF YOU DO NOT DISCONNECT THE POWER, YOU COULD GET AN ELECTRIC SHOCK.

ELECTRICAL RATING OF THIS OVEN : 120 V AC. 60 Hz.

1300 Watts 12 Amperes (Microwave oven only).

1500 Watts 14 Amperes (Microwave oven + Cooktop Lamps + Ventilation fan).

You need a 120-volt, 60 Hz, AC only, 15or 20-ampere, fused electrical supply (located in the cabinet above the microwave as close as possible to the microwave circuit) serving only the microwave.

-2 -

YOUR SAFETY FIRST

THIS APPLIANCE MUST BE GROUNDED!

If there is an electrical short circuit, grounding reduces the risk of electrical shock by providing an escape wire for the electric current. This appliance is equipped with a cord having a grounding wire with a grounding plug.

Place the plug into a properly installed and grounded outlet. See Figure 2.

Do not use an extension cord.

Keep the power cord dry and do not pinch or crush it.

DO NOT, UNDER ANY CIRCUMSTANCES, REMOVE THE POWER SUPPLY CORD GROUNDING PRONG!

This appliance MUST be grounded!

PROPERLY POLARIZED AND GROUNDED OUTLET

Three-Pronged (Grounding) plug

Figure 2

w WARNING w

If you use the grounding plug improperly, you risk electric shock!

Check with a qualified electrician if you are not sure whether the oven is properly grounded or if you do not completely understand the grounding instructions.

DO NOT USE A FUSE IN THE NEUTRAL OR GROUNDING CIRCUIT.

w WARNING w

Improper grounding could result in electric shock or other personal injury.

SAVE THESE INSTRUCTIONS FOR THE LOCAL ELECTRICAL INSPECTOR'S USE.

DO NOT EXPOSE YOURSELF TO EXCESSIVE MICROWAVE ENERGY!

DO NOT try to operate the microwave oven with the door open.

DO NOT tamper with or defeat the safety interlocks.

DO NOT place objects between the microwave oven front face and the door.

DO NOT allow soil or cleaner residue to build up on the flat surfaces around the microwave oven door.

DO NOT operate the microwave oven if it is damaged.

The microwave oven door must close properly to operate safely. DO NOT USE THE MICROWAVE OVEN:

If the door is bent.

If the hinges or latches are broken or loose.

If the door seals, sealing surfaces or glass is broken.

DO NOT ATTEMPT TO ADJUST OR REPAIR THE OVEN YOURSELF!

It should be adjusted and repaired by a qualified technician who can check for microwave leakage after repairing the oven.

w WARNING w

If you do not use the microwave oven as instructed, you could be exposed to excessive microwave energy.

- 3 -

YOUR SAFETY FIRST

MAKE SURE YOU HAVE ENOUGH SPACE AND SUPPORT.

Mount the oven against a flat, vertical wall, so that it is supported by the wall. The wall should be constructed of minimum 2" x 4" wood studding and 3/8" thick drywall or plaster/lath.

ATTACH AT LEAST ONE of the two lag screws supporting the oven to a vertical, 2" x 4" wall stud.

DO NOT mount the microwave oven to an island or peninsula cabinet.

BE SURE the upper cabinet and rear wall structures are able to support 150 lbs., plus the weight of any items you place inside the oven or upper cabinet.

Locate the oven away from strong draft areas, such as windows, doors, and strong heating vents.

w WARNING w

If you do not mount the oven as instructed, you risk personal injury and/or property damage.

– BE SURE you have enough space. See Figure 3 below for minimum vertical and horizontal clearance.

15" max. upper cabinet

Grounded Plug

 

 

(inside upper cabinet)

 

 

Power Supply

 

30" min. cabinet opening width

Cord Hole

 

 

 

30" min. clearance from bottom

 

 

of cabinet to cooking surface

 

 

or countertop

 

14" min. microwave

(Use templates included

 

oven to cooking surface

with installation instructions)

 

or countertop

 

 

Figure 3

wCAUTION w

Before you begin installing the oven, PLACE A PIECE OF THE CARTON OR OTHER HEAVY MATERIAL (a blanket) over the countertop or cooktop to protect it. Do not use a plastic cover.

Failure to protect these surfaces could result in property damage.

NOTE: Do not use this microwave oven for commercial purposes. This oven is designed for household use only.

-4 -

LG MV-1155SC Installation Manual

PARTS, TOOLS, MATERIALS

THE FOLLOWING PARTS ARE SUPPLIED WITH THE OVEN:

NOTE: You may not use all of these parts.

Damper/duct connector

(for roof-venting or wall -venting installation)

One power cord clamp and

One dark-colored mounting screw

(to hold the power cord)

Two tapping screws

(for attaching the damper duct connector)

One lock pin and one washer

One power cord bushing (for the cord hole in a metal upper cabinet)

Four 1/4" x 2" lag screws

(for wall stud holes)

Two 1/4" x 2" bolts

(for securing to the upper cabinet)

Four 1/4" x 3" toggle bolts

(for drywall holes)

Four spring toggle heads

(for the toggle bolts)

Two washers

(for the two upper cabinet bolts)

NOTE: You need to install at least one lag screw into a 2" x 4" stud and four anchor bolts into the wall and the mounting area must meet the 150+ lbs. weight requirement.

- 5 -

Loading...