LG LWHD1200R User Manual

ENGLISH ESPAÑOL
LG Window-Type Air Conditioner
LG
MODELS: LWHD1200R
PRECAUTIONS
IMPORTANT
• Please read this owner's manual carefully and thoroughly before installing and operating your room air conditioner.
• Please retain this owner's manual for future reference after reading it thoroughly.
• Antes de instalar y poner en marcha su ventilador de casa, haga el favor de leer cuidadosamente esta instrucción de Usuario.
• Luego de su lectura, guarde este manual para el futuro usuario para las referencias.
2 Room Air Conditioner
FOR Y OUR RECORDS
Write the model and serial numbers here:
Model # Serial #
You can find the numbers on a label on the side of the product.
Dealer's Name Date Purchased
Staple your receipt to this page in the event you need it to prove date of purchase or for warranty issues.
READ THIS MANU AL
Inside you will find many helpful hints on how to use and maintain your air conditioner properly.Just a little preventive care on your part can save you a great deal of time and money over the life of your air conditioner.
You'll find many answers to common problems in the chart of troubleshooting tips.If you review our chart of
Troubleshooting Tips first, you may not need to call for service at all.
PRECAUTION
Contact an Authorized Service Center for repair or
maintenance of this unit. Call 1-800-243-0000 to locate the nearest ASC.
This air conditioner is not intended for use by young
children or invalids without supervision.
Young children should be supervised to ensure that
they do not play with the air conditioner.
If the power cord requires replacement, have an
Authorized Servicer install an exact replacement part.
Installation work must be performed in accordance
with the National Electric Code by qualified and authorized personnel only.
Safety Precautions ..........................3
Before Operation .............................7
Introduction ....................................8
Symbols Used in this Manual ........8
Features ........................................8
Electrical Safety ..............................9
Temporary Use of an
Adapter ........................................11
Temporary Use of an
Extension Cord ............................11
Maintenance and Service ............21
Air Filter ....................................21
Cleaning the Air Conditioner .....21
How to Remove the
Front Grille ................................22
Common Problems and
Solutions.......................................23
Troubleshooting ............................24
Window-Type Air Conditioner Owner’s Manual
TABLE OF CONTENTS
Installation Kits Contents .............13
Installation
How to Install the unit ..................12
Requirements .............................13
Window Requirements ................12
Cabinet Installation ......................14
..................................12
Suggested Tool
Operating Instructions .................17
Remote Control Operations ........17
Remote Controller .......................18
Additional Features.......................19
Air Direction ..............................19
Vent Control ..............................19
Drain Pipe..................................20
Removal from Window...............20
Owner’s Manual 3
ENGLISH
Safety Precautions
To prevent injury to the user or other people and property damage, the following instructions must be followed.
Incorrect operation due to ignoring instructions will cause harm or damage.The seriousness is classified by the following indications.
Because of the weight of the product, it is recommended that you have a helper to assist in the installation.
Meanings of symbols used in this manual are as shown below.
WARNING
CAUTION
This symbol indicates the possibility of death or serious injury.
This symbol indicates the possibility of injury or damage to property only.
WARNING
Installation
Always install the expansion panel(s).
Improper assembly or installation may cause
incorrect operation, including injury, fire, and
Do not place the power cord near a heater.
It may cause fire and electric shock.
Do not use the power cord near flammable gas or combustibles such as gasoline, benzene, thinner, etc.
It may cause explosion or fire.
Do not disassemble or modify products.
It may cause electric shock and failure.
Be sure not to do.
Be sure to follow the instruction.
Safety Precautions
n
Gasoli
4 Room Air Conditioner
Safety Precautions
Operation
Plug in the power plug properly.
Otherwise, it will cause electric shock or fire.
Do not operate or stop the unit by inserting or pulling out the power plug.
It will cause electric shock or fire.
Do not damage or use an unspecified power cord.
It will cause electric shock or fire.
Do not modify power cord length.
It will cause electric shock or fire.
Use the air conditioner on a single outlet circuit. (See page 7.) Do not share the outlet with other appliances.
It will cause electric shock or fire.
Always plug into a grounded outlet.
No grounding may cause electric shock.
Unplug the unit if strange sounds, odors, or smoke come from it.
Otherwise it will cause fire and electric shock accident.
Do not use the socket if it is loose or damaged.
It may cause fire and electric shock.
Do not operate with wet hands or in damp environment.
It may cause electric shock.
ON
ON
Owners Manual 5
ENGLISH
CAUTION
Installation
Safety Precautions
Never touch the metal parts of the unit when removing the filter.
They are sharp and may cause injury.
Do not block the inlet or outlet.
It may cause failure of appliance or performance deteriorate.
Ensure that the outer case is not damaged by age or wear.
If the outer case is damaged, it must be repaired or replaced immediately. Leaving it damaged could result in the air conditioner falling out of the window, creating a safety hazard.
Close all doors, windows and other outside openings to the room.
The air conditioner must be operated in a enclosed area to be most effective.
Ventilate before operating air conditioner when gas goes out.
It may cause explosion, fire, and burn.
If water enters the product, turn off the power switch of the main body of appliance. Contact service center after taking the power­plug out from the socket.
It will cause electric shock or failure of machine.
Do not clean the air conditioner with water.
Water may enter the unit and degrade the insulation. It may cause an electric shock.
6 Room Air Conditioner
Safety Precautions
Unplug the air conditioner before cleaning it.
Since the fan rotates at high speed during operation, it may cause injury.
Do not put a pet or house plant where it will be exposed to direct air flow.
This could injury the pet or plant.
Do not use this appliance for special purposes such as pets, foods, precision machinery, or objects of art.
It is an air conditioner, not a precision refrigeration system.
Always insert the filter securely. Clean it every two weeks.
Operation without filters will cause failure.
Use a soft cloth to clean. Do not use wax, thinner, or a strong detergent.
The appearance of the air conditioner may deteriorate, change color, or develop surface flaws.
Do not drink water drained from air conditioner. Do not direct airflow at room occupants only.
It is not sanitary and could cause illness or personal injury hazard.
Be cautious not to touch the sharp edges when installing.
It may cause injury. It may cause electric shock and damage.
Unplug the air conditioner if it will not be used for a long period.
It will waste power consumption in vain and it may cause accident.
Operation
Sharp edges
x
a
Thinner
W
Owners Manual 7
ENGLISH
Before Operation
1. Plug in the power cord properly.
2. Use a dedicated circuit. Overloading the line could create a fire hazard.
3. Do not use an extension cord. See page 11 for more details.
4. Do not start/stop operation by plugging/unplugging the power cord.
5. If the power cord is damaged and requires replacement, have an Authorized Servicer install an exact replacement part.
1. Being exposed to direct airflow for an extended period of time could be hazardous to your health. Do not expose occupants, pets, or plants to direct airflow for extended periods of time.
2. Due to the possibility of oxygen deficiency, ventilate the room when used together with stoves or other heating devices.
3. Do not use this air conditioner for non-specified special purposes (e.g. preserving precision devices, food, pets, plants, and art objects). Such usage could damage the items.
4.The air conditioner is a consumer comfort appliance, not a precision climate
control system.
1. Do not touch the metal parts of the unit when removing the filter. Injuries can occur when handling sharp metal edges.
2. Do not use water to clean inside the air conditioner.Exposure to water can destroy the insulation, leading to possible electric shock.
3. When cleaning the unit, first make sure that the power and breaker are turned off.The fan rotates at a very high speed during operation.There is a possibility of injury if the units power is accidentally triggered on while cleaning inner parts of the unit.
For repair and maintenance, contact an Authorized Service Center. See the warranty page for details or call (800) 243-0000.Have your model number and serial number available.They should be written on page 2 of this manual.
Before Operation
Preparing for Operation
Usage
Cleaning and Maintenance
Service
8 Room Air Conditioner
Introduction
This symbol alerts you to the risk of electric shock.
This symbol alerts you to hazards that could cause harm to the air conditioner.
This symbol indicates special notes.
Tip!
WARNING:This appliance should be installed in accordance with the
National Electric Code.
Introduction
Symbols Used in this Manual
Features
Upper Guide
Horizontal Air Deflector (Horizontal Louver)
Vertical Air Deflector (Vertical Louver)
Cabinet
Front Grille
Air Filter
Air Discharge
Air Intake
(Inlet Grille)
Evaporator
Control Board
Remote Controller
Brace
Compressor
Condenser
Base Pan
Power Cord
Electrical Safety
Electrical Data
115V~ 230V~
Power cord may include a current interrupter device. A test and reset button is provided on the plug case. The device should be tested on a periodic basis by first pressing the TEST button and then the RESET button. If the TEST button does not trip or if the RESET button will not stay engaged, discontinue use of the air conditioner and contact a qualified service technician.
Electrical Safety
Use Wall Receptacle
Standard 125V, 3-wire grounding receptacle rated 15A, 125V AC
Power Supply
Use 15 AMP. time circuit breaker.
delay fuse or 15 AMP.
ENG LIS H
Standard 250V, 3-wire grounding receptacle rated 15A, 250V AC
Standard 250V, 3-wire grounding receptacle rated 20A, 250V AC
ELECTRICAL SAFETY
IMPORTANT GROUNDING INSTRUCTIONS
Air conditioner has a three-prong grounding plug on properly grounded three-prong wall receptacle for
your protection against possible shock hazard.
Use 20 AMP. time circuit breaker.
its power supply cord, which must be plugged into
delay fuse or 20 AMP.
,
9
WARNING: This appliance must be properly grounded.
The power cord of this appliance is equipped with a three-prong grounding plug. To minimize the risk of electr ic shock, use the plug with a standard three-slot grounding wall power outlet.If the power outlet does not include a grounding slot, have a qualified electrician replace the outlet before you use the room air conditioner.
WARNING: Changing the outlet without making the appropriate wiring changes will create an unsafe condition that could result in fire or electrical shock. Refer all such work to a licensed and qualified electrician.
WARNING: Do not cut or remove the grounding prong from the power plug.
WARNING: Attaching the adapter ground terminal to the wall
receptacle cover screw does not ground the appliance unless the cover screw is metal and not insulated, and the wall receptacle is grounded through the house wiring.
WARNING: If you have any doubt whether the air conditioner is
properly grounded, have the wall receptacle and circuit checked by a qualified electrician.
Preferred method
Ensure proper ground
exists before use
Electrical Safety
10 Room Air Conditioner
Electrical Safety
We strongly discourage the use of an adapter due to potential safety hazards. For temporary connections, use only a UL-listed adapter, available from most local hardware stores. Ensure that the large slot in the adapter is aligned with the large slot in the receptacle for a proper polarity connection.
To disconnect the power cord from the adapter, use one hand on each to avoid damaging the ground terminal. Avoid frequently unplugging the power cord as this can lead to eventual ground terminal damage.
WARNING: Never use the appliance with a broken adapter.
Electrical Safety
Temporary method
Adapter Plug
Receptacle Cover
Metal Screw
Temporary Use of an Adapter
Temporary Use of an Extension Cord
Owners Manual 11
ENGLISH
115VOLT UNIT
We strongly discourage the use of an extension cord due to potential safety
hazards.For temporary situations,use only CSA certified and UL listed 3-wire
grounded extension cords,rated 15 A,125V.
All wiring should be made in accordance with
NOTICE
Aluminum house wiring may pose special
230,208, and 230/208 VOLT UNITS
These units are equipped with a three-prong must be plugged into a matching properly grounded
against possible shock hazard. If such an outlet is electrician in accordance with the National Electrical
NOTICE
DO NOT USE AN EXTENSION CORD on 230,208, and 230/208 Volt units.
local electrical codes and regulations.
problems. Consult a qualified electrician.
grounding plug on the power supply cord, which
three-prong wall receptacle for your protection
not present, one must be installed by a qualified
Code and local codes and ordinances.
Room Air Conditioner
Installation
12
About 1/2"
30"~60"
Awning
Cooled air
Fence
Over 20"
Heat
radiation
27" to 39"
Offset
1
/2" to 11/4"
Sill
Exterior
Interior wall
23
5
/8" min.
(Without frame curtain)
Stool
16" min
(With frame curtain)
How to Install the Unit
To prevent vibration and noise, make sure the unit
is installed securely and firmly
Install the unit where the sunlight does not shine
directly on the unit.
The outside of the cabinet must extend outward for
at least 12" and there should be no obstacles, such as a fence or wall, within 20" from the back of the cabinet because it will prevent heat radiation of the condenser. Restriction of outside air will greatly reduce the cooling efficiency of the air conditioner.
Install the unit a little slanted so the back is slightly lower than the front (about 1/2").
This will force condensed water to flow to the outside. Install the unit with the bottom about 30"~60" above the floor level.
5
4
3
2
1
Window Requirements
: All supporting parts should be secured to firm wood, masonry, or metal.
This unit is designed for installation in standard double hung windows with actual opening widths from 27" to 39".
The top and bottom window sash must open sufficiently to allow a clear vertical opening of 16" from the bottom of the upper sash to the window stool.
NOTICE
CAUTION: All side louvers of the cabinet must remain exposed to the outside of the structure.
Installation
16
Owners Manual 13
Installation
ENGLISH
1
2 3 4
8 13
10
765
9
12
11
10
13
Shipping Screws
(Type A)
Upper guide
Upper guide
(Type A)
5
11
11
5
5
Upper guide
Installation Kits Contents
Suggested Tool Requirements
NO. NAME OF PARTS Q'TY
1 FRAME CURTAIN 2 2 SILL SUPPORT 2 3 BOLT 2 4 NUT 2 5 SCREW (TYPE A) 16 6 SCREW (TYPE B) 3 7 SCREW (TYPE C) 5 8 FOAM-STRIP 1
9 DRAIN PIPE 1 10 FOAM-PE 1 11 FRAME GUIDE 2 12 WINDOW LOCKING BRACKET 1 13 FOAM-PE 1
PREPARATION OF CHASSIS
Remove the screws which fasten the cabinet at both sides and at the back.
Slide the unit from the cabinet by gripping the base pan
handle and pulling forward while bracing the cabinet.
Cut the window sash seal to the proper length.
Peel off the backing and attach the Foam-PE
to the
underside of the window sash. Remove the backing from the top upper guide Foam-PE
and attach it to the bottom of the Upper Guide.
Attach the upper guide onto the top of the cabinet with 3 Type A screws .
Insert the Frame Guides into the bottom of the
cabinet.
Insert the Frame Curtain into the Upper Guide and
Frame Guides .
Fasten the curtains to the unit with 4 Type
A screws .
8
7
6
5
4
3
2
1
SCREWDRIVER(Philips and Flatead), RULER, KNIFE, HAMMER, PENCIL, LEVEL
Installation
INDOOR OUTDOOR
Sill Support
2
Nut
4
Bolt
3
INDOOR OUTDOOR
Cabinet
About
1
/2"
Frame Guide
11
Screw(Type A)
5
Upper Guide
Window stool
Front Angle
Window Sash
Upper guide
Frame Curtain
1
Foam-pe
10
Foam-pe
13
Cabinet
Cabinet Installation
Open the window. Mark a line on center of the window stool. Carefully place the cabinet on the window stool and align the center mark on the bottom front with the center line marked in the window stool.
Pull the bottom window sash down behind the Upper Guide until it meets.
: Do not pull the window sash down tightly that
the movement of Frame Curtain
is restricted.
Loosely assemble the Sill Support
using the parts
Select the position that will place the Sill Support near the outer most point on sill
: Be careful when you install the cabinet
(Frame Guides
are broken easily).
Attach the Sill Support to the cabinet track hole in relation to the selected position using 2 Type A screws in each support
5
NOTICE
4
3
NOTICE
2
1
Room Air Conditioner14
Owners Manual 15
ENGLISH
Installation
Sash track
Front Angle
About
1
/2"
Screw(Type B)
6
Screw(Type B)
6
Sill Support
2
Sill Support
2
Foam-Strip
8
Type C
7
Screw(Type A)
Screw
(Type A)
Power cord
The cabinet should be installed with a very slight tilt (about 1/2") downward toward the outside
Adjust the bolt and the nut of Sill Support for balancing the cabinet.
Attach the cabinet to the window stool by driving the screws
(Type B: Length 16mm (5/8 inch) and below.) through the front angle into window stool.
Pull each Frame Curtain fully to each window sash track, and repeat step 2.
Attach each Frame Curtain the window sash using
Slide the unit into the cabinet.
Cut the Foam-Strip
to the proper length and insert between the upper window sash and the lower window sash.
11
10
9
8
7
6
CAUTION: Do not drill a hole in the bottom pan. The unit is designed to operate with approximately 1/2" of water in bottom pan. There is no need to add water if the pan is dry.
CAUTION: For security purpose, reinstall screws (Type A) at cabinet's sides.
screws (Type C).
Installation
Window locking bracket
12
Attach the Window Locking Bracket with a Type C screw .
Attach the front grille to the cabinet by inserting the tabs on the grille into the tabs on the front of the cabinet. Push the grille in until it snaps into place.
Pull down the inlet grille and secure it with a Type A screw through the front grille.
Window installation of room air conditioner is now completed. See ELECTRICAL DATA for attaching power cord to electrical outlet.
15
14
13
12
Room Air Conditioner16
Loading...
+ 36 hidden pages