LG LW8016ER Owner’s Manual [en,fr]

OWNER’S MANUAL
OWNER’S MANUAL
AIR
AIR
CONDITIONER
CONDITIONER
ENGLISH
FRANÇAIS
Read this owner’s manual thoroughly before operating the appliance and keep it handy for reference at all times.
LW8016ER
MFL70960703
Rev.01_113018
Copyright © 2017-2018 LG Electronics Inc. All Rights Reserved.
www.lg.com
2
TABLE OF CONTENTS
TABLE OF CONTENTS
3 SAFETY INSTRUCTIONS
3 IMPORTANT SAFETY INSTRUCTIONS
8 PRODUCT OVERVIEW
8 Exterior Parts 8 Interior Parts
9 INSTALLATION
9 Electrical Data 10 Installation Overview 11 Clearance 11 Window Requirements 11 Preparation of Chassis 12 Unit Installation
14 OPERATION
14 Control Panel and Remote Control 15 Wireless Remote Control 16 Ventilation 16 Air Direction 16 Additional Features
17 MAINTENANCE
17 Air Filter
18 TROUBLESHOOTING
18 Before Calling for Service 18 Normal Sounds You May Hear
21 WARRANTY
ENGLISH
SAFETY INSTRUCTIONS
SAFETY INSTRUCTIONS
READ ALL INSTRUCTIONS BEFORE USE
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and follow all safety messages.
This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or injure you and others. All safety messages will follow the safety alert symbol and either the word WARNING or CAUTION.
These words mean:
WARNING
You may be killed or seriously injured if you do not follow instructions.
CAUTION
You may be injured or cause damage to the product if you do not follow instructions.
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what may happen if the instructions are not followed.
IMPORTANT SAFETY INSTRUCTIONS
3
WARNING
injury to persons when using this product, follow basic precautions, including the following:
INSTALLATION
●Before use, the appliance must be properly installed as described in this manual.
●Contact the authorized service technician for repair or maintenance of this unit.
●Contact the installer for installation of this unit.
●The air conditioner is not intended for use by young children or invalids without supervision.
●Young children should be supervised to ensure that they do not play with the air conditioner.
4
SAFETY INSTRUCTIONS
●When the power cord is to be replaced, replacement work shall be performed by authorized personnel only using only genuine replacement parts.
●Installation work must be performed in accordance with the National Electric Code by qualied and authorized personnel only.
●Connect to a properly rated, protected, and sized power circuit to avoid electrical overload.
●Always plug into a grounded outlet.
●Do not under any circumstances, cut or remove the third (ground) prong from the power cord.
●When installing or moving the appliance, be careful not to pinch, crush, or damage the power cord.
●Plug in the power plug properly.
●Do not modify or extend the power cord.
●Do not start/stop operation by plugging/unplugging the power cord.
●If the cord/plug is damaged, have it replaced by an authorized service person using authorized replacement parts.
●Use a dedicated circuit.
●Do not disassemble or modify the product.
●Adhere to all industry recommended safety procedures including the use of long-sleeved gloves and safety glasses.
●Use care when unpacking and installing. The edges of the product may be sharp.
●Disconnect the power cord or circuit breaker before installing or servicing the appliance.
●Keep packaging materials out of the reach of children. These materials can pose a suffocation risk to children.
●Store and install the product where it will not be exposed to temperatures below freezing or exposed to outdoor weather conditions.
●Do not store or use gasoline or other ammable vapors and liquids in the vicinity of this or any other appliance.
OPERATION
●Use this appliance only for its intended purpose.
●Never attempt to operate this appliance if it is damaged, malfunctioning, partially disassembled, or has missing or broken parts, including a damaged cord or plug.
●Repair or immediately replace all power cords that have become frayed or otherwise damaged. Do not use a cord that shows cracks or abrasion damage along its length or at either end.
●Do not run cord under carpets or mats where it could be stepped on and damaged.
●Keep the cord out from under heavy objects like tables or chairs.
●Do not place the power cord near a heat source.
●Do not use an adaptor or plug the product into a shared outlet.
●Do not tamper with controls.
●If you detect a strange sound, a chemical or burning smell, or smoke coming from the appliance, unplug it immediately, and contact an LG Electronics Customer Information Center.
●Never unplug the appliance by pulling on the power cord. Always grip the plug rmly and pull straight out from the outlet.
●Do not grasp the power cord or touch the appliance controls with wet hands.
ENGLISH
SAFETY INSTRUCTIONS
●If water enters the product, turn off the power at the main circuit, then unplug the product and call for service.
●If the product has been submerged, contact an LG Electronics Customer Information Center for instructions before resuming use.
●Unplug the product when unused for long periods.
●Unplug the product before cleaning.
●In the event of a gas leak (propane gas, etc.) do not operate this or any other appliance. Open a window or door to ventilate the area immediately.
●This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety.
●The interior of the product must only be cleaned by an authorized service center or a dealer.
●Do not use solvent-based detergent on the product. Doing so can cause corrosion or damage,
product failure, electrical shock, or re.
GROUNDING INSTRUCTIONS
●The power cord of this appliance is equipped with a three-prong (grounding) plug. Use this with a standard three-slot (grounding) wall power outlet to minimize the hazard of electric shock. The
customer should have the wall receptacle and circuit checked by a qualied electrician to make
sure the receptacle is properly grounded. DO NOT CUT OR REMOVE THE THIRD (GROUND) PRONG FROM THE POWER PLUG.
- Situations when the appliance will be disconnected occasionally; Because of potential safety hazards, we strongly discourage the use of an adapter plug. However, if you wish to use an adapter, a TEMPORARY CONNECTION may be made. Use UL-listed adapter, available from most local hardware stores. The large slot in the adapter must be aligned with the large slot in the receptacle to assure a proper polarity connection.
●Attaching the adapter ground terminal to the wall receptacle cover screw does not ground the appliance unless the cover screw is metal, and not insulated, and the wall receptacle is grounded
through the house wiring. The customer should have the circuit checked by a qualied electrician
to make sure the receptacle is properly grounded.
●Disconnect the power cord from the adapter, using one hand on each. Otherwise, the adapter ground terminal might break. Do not use the appliance with a broken adapter plug.
- Situations when the appliance will be disconnected often; Do not use an adapter plug in these situations. Unplugging the power cord frequently can lead to an eventual breakage of the ground terminal. The wall power outlet should be replaced by a three-slot (grounding) outlet instead.
5
6
SAFETY INSTRUCTIONS
CAUTION
To reduce the risk of minor or moderate injury to persons, malfunction, or damage to the product or property when using this product, follow basic precautions, including the following:
INSTALLATION
●Take care when installing the product that exhaust or condensation does not damage nearby property.
●Follow installation instructions exactly to avoid excessive vibration or water leakage.
OPERATION
●This appliance is not intended for use as a precision refrigeration system. Do not use it for special purposes such as maintaining pets, food, precision machinery, or art objects.
●When installing or moving the appliance, be careful not to pinch, crush, or damage the power cord.
●Make sure the air inlet and outlet are free from obstructions.
●Use a soft cloth to clean the appliance. Do not use waxes, thinners, or harsh detergents.
●Do not step on or place heavy objects on top of the appliance.
●Do not drink water drained from the appliance.
are used simultaneously. Do not expose people, animals, or plants to the cold or hot wind from the air conditioner for
extended periods of time.
●Remove the batteries if the remote control is not to be used for an extended period of time.
●Never mix different types of batteries, or old and new batteries for the remote control.
consult a doctor.
●Do not recharge or disassemble the batteries.
f with clean water.
MAINTENANCE
●Never use strong cleaning agents or solvents when cleaning the air conditioner or spray water. Use a smooth cloth.
ENGLISH
REFRIGERANT (FOR R32 ONLY)
SAFETY INSTRUCTIONS
7
WARNING
●Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer.
●The appliance shall be stored in a room without continuously operating ignition sources (for
example: open ames, an operating gas appliance or an operating electric heater).
●Do not pierce or burn. Be aware that ammable refrigerants may not contain an odor.
CAUTION
●This unit contains ammable refrigerant and has special safety precautions not normally associated with older units. Please follow all precautions and advisories.
- Use caution while handling and prevent damage to unit. Do not put any holes into product for any reason. This can cause damage to product and prevent unit from cooling.
- Maintenance and cleaning of unit should be performed by trained personnel. Failure to properly clean unit can result in damage to the refrigeration system and or the electrical system.
- Make certain that all the air circulation/ventilation openings are free from obstruction.
- Service should only be performed by technicians properly trained and certied in the use of
ammable refrigerants. Any service performed by unauthorized servicers/individuals will void all
warranties.
- When storing the appliance, do not put in a room with any open ame appliances, such as gas water heaters or furnaces. Also keep away from electric heaters. Damaged units should be repaired before storage.
SAVE THESE INSTRUCTIONS
8
PRODUCT OVERVIEW
PRODUCT OVERVIEW
Exterior Parts Interior Parts
8
6
Control Panel
1
Remote Controller
2
Air Filter
3
4
5
Front Grille
6
Air Outlet
7
Cabinet
8
7
1
4
5
3 2
2
1
1
2
3
4
5
6
7
Evaporator
Air Guide
Brace
Compressor
Condenser
Base Pan
Power Cord
3
4
5
6
7
INSTALLATION
Electrical Data
Power cord may include a current interrupter device. TEST and RESET buttons are provided on the plug case. The device should be tested on
and then the RESET button. If the TEST button does not trip or if the RESET button will not stay engaged, discontinue use of the air conditioner
for 120 V
RESET
TEST
Use Wall Receptacle Power Supply
Standard 120 V, 3-wire grounding receptacle rated 15 A / 120 VAC / 60 Hz
TEST button
Use 15 A, time delay fuse or 15 A, circuit breaker.
INSTALLATION
WARNING
●This appliance should be installed in accordance with the National Electrical Code.
●Use of extension cords could cause serious injury or death.
- Do not use an extension cord with this window air conditioner.
- Do not use surge protectors or multi-outlet adapters with this window air conditioner.
●Never push the TEST button during
operation. Doing so can damage the plug.
- Do not remove, modify, or immerse this plug. If this device trips, the cause should be corrected before further use.
CAUTION
●The conductors inside this cord are surrounded by shields, which monitor leakage current. These shields are not grounded. Periodically examine the cord for any damage. Do not use this product in the event the shields become exposed. Avoid shock hazard. This unit cannot be user-serviced. Do not open the tamper­resistant sealed portion. All warranties and performance will be voided. This unit is not intended to be used as an ON/OFF switch.
9
ENGLISH
10
INSTALLATION
Installation Overview
Seal Strip (2) (Adhesive backed)
Foam-Heatproof (2) (Adhesive backed)
Sash Seal (Not adhesive backed)
Left Guide panel
Accessories
Type 'A' Screws
(11)
Right Guide panel
L bracket (3)
Support bracket
Type 'B' Screws
(5)
Tools Needed
Phillips-head
screwdriver
Tape measure Cutting knife Scissors Pencil
Flat-blade screwdriver Adjustable wrench Level
INSTALLATION
11
Clearance
Proper clearance enhances the cooling efficiency of the product.
If storm window presents interference,
1
fasten a 2” wide wood strip to the inner window sill across the full width of the sill. The wood strip should be thick enough to raise the height of the window sill so that the unit can be installed without interference by the storm window frame.
The top of the wood strip on the inside sill
2
should be approximately ¾” higher than the storm window frame or wood strip on the outside sill to help condensation to drain properly to the outside.
Install a second wood strip (approximately
3
6” long by 1 ½” wide and same thickness as first strip) in the center of the outer sill flush against the back off the inner sill. This will raise the L bracket as shown.
If the distance between STORM WINDOW
4
FRAME and WOOD STRIP MOUNTED ON TOP OF INNER SILL is more than 1”, two of wood strip are not necessary.
L Bracket
Storm Window Frame
¾" (19.1mm)
Clearance
Outer Sill
Wood Strip Mounted
on Top of Inner Sill
Inner Sill
1" (25.4mm) MAX.
Wood Strip for L bracket
NOTE
This prodcut is a WINDOW AIR CONDITIONER. As such, a standard single-hung or double-hung window is required for proper installation. No-window installations, including using sleeves, holes in walls, and other installations are not recommended.
Preparation of Chassis
Insert the guide panels into the guides of the
1
air conditioner. Fasten the curtains to the unit with screws (Type A).
Cut the adhesive-backed seal strip to the
2
window length. Remove the backing from seal strip and attach the seal strip to the underside of the window sash and bottom of window frame.
ENGLISH
Indoors
Outdoors
Window Requirements
●This unit is designed for installation in standard double hung windows with actual opening widths from 22" to 36". The upper and lower window sashes must open sufficiently to allow a clear vertical opening of 13" from the bottom of the upper sash to the window sill.
22" to 36"
(559mm to 914mm)
13"
(330mm)
min
Seal Strip
Open the window and mark center line
3
on the center of the inner sill.
Inner Sill
Room Side
Center Line
12
INSTALLATION
Install the L bracket behind the inner
4
window sill, with short side of bracket as shown. Use the 2 screws (Type A) provided.
Outer Sill
Outside
Inner Sill
8"
(203mm)
L Bracket
8"
(203mm)
Inside
Center Line
NOTE
The bracket helps to hold unit securely in place. Be sure to place bracket edge flush against back of inner sill.
Unit Installation
CAUTION
During the following step, hold unit firmly until window sash is lowered to top channel behind side panel frames. Personal injury or property damage may result if unit falls from window.
Carefully lift the air conditioner and slide it into
1
the open window. Make sure the bottom guide of the air conditioner drops into the notches of the L bracket.
Center Line
NOTE
When the air conditioner drops into the L bracket, the air conditioner will be centered in window opening.
While steadying the air conditioner, carefully
2
bring the window sash down behind the upper guide of the air conditioner. When the air conditioner is properly installed, it should tilt slightly down at the back. If it is set correctly in the window, it will hang lower in the back automatically. If it does not, there is a problem with the installation.
Window Frame
Upper Guide
Extend the guide panels to fill the window
3
opening using 4 screws (Type B) to secure them.
Seal
L Bracket
About (6.4mm)
Bottom Guide
¼"
INSTALLATION
13
Cut the sash seal to the window width.
4
Stuff the sash seal between the glass and the window to prevent air and insects from getting into the room. Fasten the L bracket using a screw (Type A). Remove the screws that secure the cabinet and base pan in the right side.
L Bracket
Type A
Type B
Fasten the support bracket using a screw
5
removed from the air conditioner cabinet. Attach the support bracket to the inner window sill with a screw (Type B).
Sash Seal
Cut the adhesive-backed Foam-Heatproof
6
to match the size of the guide panels. Remove the backing from the Foam-Heatproof and attach it to the guide panels.
NOTE
Foam-Heatproof improves the cooling capability of the unit.
Foam-Heatproof
NOTE
●See the 'Electrical Data' section for information on attaching the power cord to an electrical outlet.
ENGLISH
Support Bracket
Type B
14
OPERATION
OPERATION
Control Panel and Remote Control
OPERATION
7
4 3 2
Power
1
Operation starts when this buttom is pressed and stops when you press the buttom again.
Fan Speed
2
Use to set the fan speed to Low (F1), MED (F2), High (F3).
ON/OFF Timer
3
Delay ON - When the air conditioner is off,
it can be set to automatically turn on from 1 to 24 hours at its previous mode and fan settings.
Delay OFF - When the air conditioner is on, it can be set to automatically turn on from 1 to 24 hours.
NOTE
●Each press of the Timer button advances the timer by 1 hour. After the last press the display returns to the temperature setting.
Remote Control
6
5
1
4
5
3
Operation Mode Selector
Push the Mode button to rotate between Energy Saver / Cool / Fan / Dry.
Energy Saver - The fan stops when the compressor stops cooling. Approximately every 3 minutes the fan will turn on and check the room air temperature if cooling is needed.
- Compressor runs and cools the
Cool
room. Use the and FAN buttons to set the desired temperature and circulation fan speed.
Fan - Fan circulates air but the compressor does not run. Use the FAN button to set the desired fan speed.
Dry - Dry mode is used to remove humidity from the room without additional cooling. Once the set temperature is reached, the compressor and circulation fan turns off. Fan speed is pre-set and cannot be adjusted.
1
2
4
.
Temperature Control
5
The thermostat monitors room temperature to maintain the desired temperature. The thermostat can be set between 60 °F–86 °F (16 °C–30 °C). Press increase or decrease temperature setting.
Remote Control Sensor
6
Clean Filter
7
The Clean Filter LED lights up to notify you
that the lter needs to be cleaned. After cleaning the lter, press Temp
together on the control panel to turn off the Clean Filter light.
or arrows to
and
NOTE
●The lter reset must be done using the control panel, not the remote control.
●This feature is a reminder to clean the air
lter for more efcient operation. The LED
light turns on after 250 hours of operation.
NOTE
Auto Restart: If the air conditioner turns off due
to a power outage, it will restart automatically once the power is restored, with the same settings as were set before the unit turned off.
Energy Saver: The unit defaults to the Energy
Saver mode each time the unit is switched on except in Fan mode or when power is restored after an electrical power outage.
●The remote control will not function properly if the AC infrared sensor is exposed to direct light or if there are obstacles between the remote controller and the air conditioner
.
OPERATION
Wireless Remote Control
Inserting Battery
Remove the cover from the back of the
1
remote controller.
Insert one battery.
2
Reattach the cover.
3
NOTE
●Be sure that the (+) and (-) directions are correct.
●Be sure that the battery is new.
●Do not use a rechargeable battery.
●In order to prevent discharge, remove the battery from the remote control if the air conditioner is not going to be used for an extended period of time.
●Keep the remote control away from extremely hot or humid places.
●To maintain optimal operation of the remote control, the remote sensor should not be exposed to direct sunlight.
15
ENGLISH
16
OPERATION
Ventilation
Push the ventilation lever in to the closed position to maintain the best cooling performance. Pull the ventilation lever out to open the vent and draw fresh air into the room.
Close Open
Air Direction
of the air conditioner’s louvers.
Direction
levers of the vertical louvers to the left or right.
Additional Features
Slinger Fan
This air conditioner is equipped with a slinger fan. (See drawing.) The fan’s outer ring picks up the condensed water from the base pan if the water level gets high enough. The water is then picked up by the fan and expelled through the condenser, making
Ring
Direction
up or down.
NOTE
●When the weather is extremely hot, the unit may turn off automatically to protect the compressor.