9 Electrical Data
10 Installation Overview
11 How to Install the Unit
11 Window Requirements
11 Clearance
11 Preparation of Unit
12 Unit Installation
14 OPERATION
14 Control Panel and Remote Control
15 Wireless Remote Control
16 Ventilation
16 Air Direction
16 Additional Features
17 SMART FUNCTIONS
17 Using LG SmartThinQ Application
20 MAINTENANCE
20 Air Filter
21 TROUBLESHOOTING
21 Before Calling for Service
21 Normal Sounds You May Hear
25 WARRANTY
ENGLISH
SAFETY INSTRUCTIONS
SAFETY INSTRUCTIONS
READ ALL INSTRUCTIONS BEFORE USE
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always
read and follow all safety messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or injure you and others.
All safety messages will follow the safety alert symbol and either the word WARNING or
CAUTION.
These words mean:
WARNING
You may be killed or seriously injured if you do not follow instructions.
CAUTION
You may be injured or cause damage to the product if you do not follow instructions.
All safety messages will tell you what the potential hazard is, tell you how to reduce
the chance of injury, and tell you what may happen if the instructions are not followed.
IMPORTANT SAFETY INSTRUCTIONS
3
WARNING
injury to persons when using this product, follow basic precautions,
including the following:
INSTALLATION
● Before use, the appliance must be properly installed as described in this manual.
● Contact the authorized service technician for repair or maintenance of this unit.
● Contact the installer for installation of this unit.
● The air conditioner is not intended for use by young children or invalids without supervision.
● Young children should be supervised to ensure that they do not play with the air conditioner.
4
SAFETY INSTRUCTIONS
● When the power cord is to be replaced, replacement work shall be performed by authorized
personnel only using only genuine replacement parts.
and authorized personnel only.
● Connect to a properly rated, protected, and sized power circuit to avoid electrical overload.
● Always plug into a grounded outlet.
● Do not under any circumstances, cut or remove the third (ground) prong from the power cord.
● When installing or moving the appliance, be careful not to pinch, crush, or damage the power
cord.
● Plug in the power plug properly.
● Do not modify or extend the power cord.
● Do not start/stop operation by plugging/unplugging the power cord.
● Do not turn on the circuit breaker or power under condition that front grille, cabinet, control box
are removed or opened. Otherwise, it may cause fire, electric shock, explosion or death.
● If the cord/plug is damaged, have it replaced by an authorized service person using authorized
replacement parts.
● Use a dedicated circuit.
● Do not disassemble or modify the product.
● Adhere to all industry recommended safety procedures including the use of long-sleeved gloves
and safety glasses.
● Use care when unpacking and installing. The edges of the product may be sharp.
● Disconnect the power cord or circuit breaker before installing or servicing the appliance.
● Keep packaging materials out of the reach of children. These materials can pose a suffocation
risk to children.
● Store and install the product where it will not be exposed to temperatures below freezing or
exposed to outdoor weather conditions.
other appliance.
OPERATION
● Use this appliance only for its intended purpose.
● Never attempt to operate this appliance if it is damaged, malfunctioning, partially disassembled,
or has missing or broken parts, including a damaged cord or plug.
● Repair or immediately replace all power cords that have become frayed or otherwise damaged.
Do not use a cord that shows cracks or abrasion damage along its length or at either end.
● Do not run cord under carpets or mats where it could be stepped on and damaged.
● Keep the cord out from under heavy objects like tables or chairs.
● Do not place the power cord near a heat source.
● Do not use an adaptor or plug the product into a shared outlet.
● Do not tamper with controls.
● If you detect a strange sound, a chemical or burning smell, or smoke coming from the appliance,
unplug it immediately, and contact an LG Electronics Customer Information Center.
straight out from the outlet.
● Do not grasp the power cord or touch the appliance controls with wet hands.
SAFETY INSTRUCTIONS
● If water enters the product, turn off the power at the main circuit, then unplug the product and call
for service.
● If the product has been submerged, contact an LG Electronics Customer Information Center for
instructions before resuming use.
● Unplug the product when unused for long periods.
● Unplug the product before cleaning.
● In the event of a gas leak (propane gas, etc.) do not operate this or any other appliance. Open a
window or door to ventilate the area immediately.
● This appliance is not intended for use by persons (including children) with reduced physical,
sensory or mental capabilities, or lack of experience and knowledge, unless they have been
given supervision or instruction concerning the use of the appliance by a person responsible for
their safety. Children should be supervised to ensure that they do not play with the appliance.
● The interior of the product must only be cleaned by a LG Electronics Customer Information
Center or a dealer.
● Do not use solvent-based detergent on the product. Doing so can cause corrosion or damage,
GROUNDING INSTRUCTIONS
● The power cord of this appliance is equipped with a three-prong (grounding) plug. Use this with
a standard three-slot (grounding) wall power outlet to minimize the hazard of electric shock. The
sure the receptacle is properly grounded. DO NOT CUT OR REMOVE THE THIRD (GROUND)
PRONG FROM THE POWER PLUG.
- Situations when the appliance will be disconnected occasionally; Because of potential safety
hazards, we strongly discourage the use of an adapter plug. However, if you wish to use an
adapter, a TEMPORARY CONNECTION may be made. Use UL-listed adapter, available from
most local hardware stores.
The large slot in the adapter must be aligned with the large slot in the receptacle to assure a
proper polarity connection.
● Attaching the adapter ground terminal to the wall receptacle cover screw does not ground the
appliance unless the cover screw is metal, and not insulated, and the wall receptacle is grounded
5
ENGLISH
to make sure the receptacle is properly grounded.
● Disconnect the power cord from the adapter, using one hand on each. Otherwise, the adapter
ground terminal might break. Do not use the appliance with a broken adapter plug.
- Situations when the appliance will be disconnected often; Do not use an adapter plug in these
situations. Unplugging the power cord frequently can lead to an eventual breakage of the
ground terminal. The wall power outlet should be replaced by a three-slot (grounding) outlet
instead.
6
SAFETY INSTRUCTIONS
CAUTION
To reduce the risk of minor or moderate injury to persons, malfunction, or
damage to the product or property when using this product, follow basic
precautions, including the following:
INSTALLATION
● Take care when installing the product that exhaust or condensation does not damage nearby
property.
● Follow installation instructions exactly to avoid excessive vibration or water leakage.
OPERATION
● This appliance is not intended for use as a precision refrigeration system. Do not use it for special
purposes such as maintaining pets, food, precision machinery, or art objects.
● When installing or moving the appliance, be careful not to pinch, crush, or damage the power
cord.
● Make sure the air inlet and outlet are free from obstructions.
● Use a soft cloth to clean the appliance. Do not use waxes, thinners, or harsh detergents.
● Do not step on or place heavy objects on top of the appliance.
● Do not drink water drained from the appliance.
are used simultaneously.
Do not expose people, animals, or plants to the cold or hot wind from the air conditioner for
extended periods of time.
● Remove the batteries if the remote control is not to be used for an extended period of time.
● Never mix different types of batteries, or old and new batteries for the remote control.
consult a doctor.
● Do not recharge or disassemble the batteries.
f with clean water.
MAINTENANCE
● Never use strong cleaning agents or solvents when cleaning the air conditioner or spray water.
Use a smooth cloth.
ENGLISH
REFRIGERANT (FOR R32 ONLY)
SAFETY INSTRUCTIONS
7
WARNING
●Do not use means to accelerate the defrosting process or to clean, other than those
recommended by the manufacturer.
●The appliance shall be stored in a room without continuously operating ignition sources (for
example: open ames, an operating gas appliance or an operating electric heater).
●Do not pierce or burn. Be aware that ammable refrigerants may not contain an odor.
CAUTION
●This unit contains ammable refrigerant and has special safety precautions not normally
associated with older units. Please follow all precautions and advisories.
- Use caution while handling and prevent damage to unit. Do not put any holes into product for
any reason. This can cause damage to product and prevent unit from cooling.
- Maintenance and cleaning of unit should be performed by trained personnel. Failure to properly
clean unit can result in damage to the refrigeration system and or the electrical system.
- Make certain that all the air circulation/ventilation openings are free from obstruction.
- Service should only be performed by technicians properly trained and certied in the use of
ammable refrigerants. Any service performed by unauthorized servicers/individuals will void all
warranties.
- When storing the appliance, do not put in a room with any open ame appliances, such as gas
water heaters or furnaces. Also keep away from electric heaters. Damaged units should be
repaired before storage.
SAVE THESE INSTRUCTIONS
8
PRODUCT OVERVIEW
PRODUCT OVERVIEW
Exterior PartsInterior Parts
8
7
Control Panel
1
Remote Controller
2
3
Air Filter
4
5
6
Air Inlet
Front Grille
7
Cabinet
8
Air Outlet
9
9
1
6
4 35
2
1
2
Evaporator
1
Air Guide
2
Control Box
3
Condenser
4
Compressor
5
Base Pan
6
Power Cord
7
3
4
5
6
7
INSTALLATION
Electrical Data
Power cord may include a current interrupter
device. TEST and RESET buttons are provided
on the plug case. The device should be tested on
and then the RESET button. If the TEST button
does not trip or if the RESET button will not stay
engaged, discontinue use of the air conditioner
for 120 V
RESET
TEST
Use Wall ReceptaclePower Supply
Standard 120 V, 3-wire
grounding receptacle rated
15 A / 120 VAC / 60 Hz
TEST button
Use 15 A, time
delay fuse or 15 A,
circuit breaker.
INSTALLATION
WARNING
● This appliance should be installed in
accordance with the National Electrical
Code.
● Use of extension cords could cause serious
injury or death.
- Do not use an extension cord with this
window air conditioner.
- Do not use surge protectors or multi-outlet
adapters with this window air conditioner.
● Never push the TEST button during
operation. Doing so can damage the plug.
- Do not remove, modify, or immerse this
plug. If this device trips, the cause should
be corrected before further use.
CAUTION
● The conductors inside this cord are
surrounded by shields, which monitor
leakage current. These shields are not
grounded. Periodically examine the cord
for any damage. Do not use this product
in the event the shields become exposed.
Avoid shock hazard. This unit cannot be
user-serviced. Do not open the tamperresistant sealed portion. All warranties and
performance will be voided. This unit is not
intended to be used as an ON/OFF switch.
9
ENGLISH
10
INSTALLATION
Installation Overview
Foam-PE (2)
(Adhesive backed)
Heatproof foam (2)
(Adhesive backed)
Foam strip
(Non-adhesive)
Left Guide
panel
Accessories
Type 'A' Screws
(11)
Right Guide
panel
L bracket (3)
Support bracket
Type 'B' Screws
(5)
Tools Needed
Phillips-head
screwdriver
Tape measureCutting knifeScissorsPencil
Flat-blade screwdriverAdjustable wrenchLevel
INSTALLATION
11
How to Install the Unit
To prevent vibration and noise, make sure
1
the unit is installed securely and firmly.
Install the unit where the sunlight dose not
2
shine directly on the unit.
The outside of the cabinet must extend out-
3
ward for at least 12" and there should be no
obstacles, such as a fence or wall, within 20"
from the back of the cabinet because it will
prevent heat radiation of the condenser.
Restriction of outside air will greatly reduce
the cooling efficiency of the air conditioner.
Awning
Cooled air
Heat
radiation
4
CAUTION
● All side louvers of the cabinet must remain
exposed to the outside of the structure.
Install the unit slightly tilted so the back is
4
slightly lower than the front (about 1/4").
This will force condensed water to flow to
the outside.
Install the unit with the bottom between
5
30" ~60" above the floor level.
Fence
Clearance
Proper clearance enhances the cooling efficiency
of the product.
If a storm window presents interference,
1
fasten a 2” wide wood strip to the inner
window sill across the full width of the sill.
The wood strip should be thick enough to
raise the height of the window sill so that
the unit can be installed without interference
by the storm window frame.
(See drawing.) The top of the wood strip on
2
the inside sill should be approximately ¾”
higher than the storm window frame or wood
strip on the outside sill to help condensation
to drain properly to the outside.
If necessary, install a second wood strip
3
(same thickness as first strip) in the center
of sill flush against the back off the inner sill.
This will raise the L bracket as shown in
the drawing.
Wood Strip Mounted
on Top of Inner Sill
Inner Sill
Wood Strip for
L bracket
Indoors
L Bracket
¾"
Clearance
Storm
Window Frame
Outer Sill
Outdoors
ENGLISH
Window Requirements
● This unit is designed for installation in standard
double hung windows with actual opening
widths from 22" to 36".
The top and bottom window sashes must open
13" from the bottom of the upper sash to the
inside sill.
22" to 36"
13" min
NOTE
● This prodcut is a WINDOW AIR CONDITIONER.
As such, a standard single-hung or double-hung
window is required for proper installation.
No-window installations, including using sleeves,
holes in walls, and other installations are not
recommended.
Preparation of Unit
Insert the top and bottom rails of the curtain
1
panels into the upper and lower panel
guides.
Upper Panel Guide
Left Curtain Panel
Right Curtain Panel
Lower Panel
Guide
12
INSTALLATION
Fasten the curtain panels to the unit with 8
2
type A screws.
Cut the window sash seals to the proper
3
length. Peel off the backing and attach the
Foam-PE(Adhesive backed) to the
underside of the window sash and bottom
of window frame.
Foam-PE
(Adhesive backed)
Open the window and mark center line
4
on the center of the inner sill.
NOTE
●
The bracket helps to hold unit securely in
place. Be sure to place bracket edge flush
against back of inner sill.
Unit Installation
CAUTION
●
During the following step, hold unit firmly until
window sash is lowered to top channel behind
side panel frames. Personal injury or property
damage may result if unit falls from window.
Set the air conditioner in the window so that
1
is centered. Place the air conditioner so that
front edge of the bottom guide is against the
back edge of the sill.
Bring the window down so that the front edge
of the upper guide is in front of the window.
Make sure that air conditioner is level or
tilting slightly to the outside.
Window Frame
Upper Guide
Seal
About
¼"
Inner Sill
Room Side
Install the L bracket behind the inner
5
window sill, with short side of bracket as
shown. Use the 2 Type A screws provided.
Inner Sill
Outer Sill
Center Line
Center Line
L Bracket
L Bracket
Extend the guide panels to fill the window
2
opening using 4 Type B screws to secure
them.
Bottom Guide
INSTALLATION
13
Cut the non-adhesive foam strip to the
3
proper length and insert it between the
upper window sash and the lower window
sash.
Foam Strip
(Non-adhesive)
Attach the window locking bracket with
4
a type A screw.
Window Locking Bracket
NOTE
● Fasten the remaining L bracket to the outer
window sash with 1 type A screw as shown.
Remove the screw form the right side of
5
cabinet. Fasten the support bracket using a
removed from the air conditioner cabinet.
Attach the support bracket to the inner
window sill with a Type B screw.
Screw
(Type B)
Support Bracket
Cut the adhesive-backed heatproof foam
6
to match the size of the curtain panels.
Remove the backing from the heatproof
foam and attach it to the curtain panels.
NOTE
●
Heatproof foam improves the cooling
capability of the air conditioner.
ENGLISH
Vinyl
Wood
Heatproof Foam
NOTE
● See the 'Electrical Data' section for
information on attaching the power cord
to an electrical outlet.
14
OPERATION
OPERATION
Control Panel and Remote Control
576
8
Remote Control
1
8
9
4321
Power
1
Press to turn the air conditioner ON or OFF.
Sleep Mode
2
This mode keeps operating noise to a
minimum and turns the air conditioner off
after a set time. The timer can be set from
1 to 7 hours.
● In the Sleep Mode, the setting temperature
increases by 2 °F after 30 minutes and
additional 2 °F after another 30 minutes
for a more comfortable sleep.
● The setting temperature increases up to
4 °F from the preset temperature.
Delay ON/OFF Timer
3
Delay ON - When the air conditioner is off,
set it to automatically turn on from 1 to 24
hours later, at its previous mode and fan
settings.
Delay OFF - When the air conditioner is on,
set it to automatically turn off from 1 to 24
hours later.
NOTE
● Each press of the Timer button advances
the timer by 1 hour. After the last press
the display returns to the temperature
setting.
Operation Mode
4
Press the Mode button to cycle between
4 types of air conditioner operation: Energy
Saver / Cool / Fan Only / Dry.
4
3
Energy Saver - In this mode the
compressor and fan turn off when the set
temperature is achieved. Approximately
every 3 minutes the fan turns on to allow
the unit sensor to accurately determine if
more cooling is needed.
Cool - This mode is ideal on hot days to
cool and dehumidify the room quickly. Use
the Temp
room temperature and use the Fan Speed
button to set the desired fan circulation
speed.
Fan Only - In this mode the fan circulates
air but the compressor does not run. Use
the Fan Speed button to set fan speed to
High, Medium or Low. In this mode, you
cannot adjust the set temperature.
Dry - This mode is ideal for rainy and
damp days to dehumidify the room rather
removed from the room by the combination
of compressor operation and the fan speed
off once the set temperature is reached.
Fan speed cannot be adjusted in Dry mode.
Wi-Fi
5
Enables connection of the air conditioner to
the home Wi-Fi.
buttons to set the desired
7
10
2
Clean Filter
6
The Clean Filter LED lights up to notify you
together on the control panel to turn off the
Temp
Clean Filter light.
and
NOTE
●
control panel, not the remote control.
● This feature is a reminder to clean the air
light turns on after 250 hours of operation.
Fan Speed
7
Press to set the fan speed to Low (F1),
Medium (F2), or High (F3).
Temperature Control
8
The thermostat monitors room temperature
to maintain the desired temperature. The
thermostat can be set between 60 °F–86 °F
(16 °C–30 °C). Press
increase or decrease temperature setting.
Energy Saver
9
In this mode the compressor and fan turn
off when the set temperature is achieved.
Approximately every 3 minutes the fan turns
on to allow the unit sensor to accurately
determine if more cooling is needed.
Clear
10
Cancel Sleep and Timer settings.
or arrows to
NOTE
● Auto Restart: If the air conditioner turns off due
to a power outage, it will restart automatically
once the power is restored, with the same
settings as were set before the unit turned off.
● Energy Saver: The unit defaults to the Energy
Saver mode each time the unit is switched on
except in Fan mode or when power is restored
after an electrical power outage.
● The remote control will not function properly if
the AC infrared sensor is exposed to direct light
or if there are obstacles between the remote
controller and the air conditioner.
OPERATION
15
Wireless Remote Control
Inserting Batteries
If the display screen of the remote control begins
to fade, replace the batteries. Insert AAA (1.5 V)
batteries before using the remote control.
Remove the cover on the back of the
1
remote control.
Insert the new batteries and make sure that
2
the + and - terminals of the batteries are
installed correctly.
NOTE
● New batteries are supplied with the air
conditioner for use in the remote control.
● Do not use a rechargeable battery. Make sure
that the battery is new.
● In order to prevent discharge, remove the
battery from the remote control if the air
conditioner is not going to be used for an
extended period of time.
● Keep the remote control away from extremely
hot or humid places.
● To maintain optimal operation of the remote
control, the remote sensor should not be
exposed to direct sunlight.
ENGLISH
16
OPERATION
Ventilation
Push the ventilation lever in to the closed position
to maintain the best cooling performance. Pull
the ventilation lever out to open the vent and
draw fresh air into the room.
Close Open
Air Direction
of the air conditioner’s louvers.
Direction
levers of the vertical louvers to the left or right.
Additional Features
Slinger Fan
This air conditioner is equipped with a slinger
fan. (See drawing.)
The fan’s outer ring picks up the condensed
water from the base pan if the water level gets
high enough. The water is then picked up by the
fan and expelled through the condenser, making
Ring
Direction
up or down.
NOTE
● When the weather is extremely hot, the unit
may turn off automatically to protect the
compressor.
SMART FUNCTIONS
Using LG SmartThinQ
Application
Things to check before using LG
SmartThinQ
• For appliances with the logo
Check the distance between the appliance
1
and the wireless router (Wi-Fi network).
• If the distance between the appliance and
the wireless router is too far, the signal
strength becomes weak. It may take a
long time to register or installation may
fail.
Turn off the Mobile data or Cellular Data
2
on your smartphone.
• For iPhones, turn data off by going to Settings→ Cellular→ Cellular Data.
Connect your smartphone to the wireless
3
router.
SMART FUNCTIONS
NOTE
• To verify the Wi-Fi connection, check that
Wi-Fi icon on the control panel is lit.
• The appliance supports 2.4 GHz Wi-Fi
networks only. To check your network
frequency, contact your Internet service
provider or refer to your wireless router
manual.
• LG SmartThinQ is not responsible for any
network connection problems or any faults,
malfunctions, or errors caused by network
connection.
• If the appliance is having trouble connecting to
the Wi-Fi network, it may be too far from the
router. Purchase a Wi-Fi repeater (range
extender) to improve the Wi-Fi signal strength.
• The Wi-Fi connection may not connect or may
be interrupted because of the home network
environment.
• The network connection may not work
properly depending on the Internet service
provider.
• The surrounding wireless environment can
make the wireless network service run slowly.
• The appliance cannot be registered due to
problems with the wireless signal
transmission. Unplug the appliance and wait
about a minute before trying again.
• If the firewall on your wireless router is
enabled, disable the firewall or add an
exception to it.
• The wireless network name (SSID) should be
a combination of English letters and numbers.
(Do not use special characters.)
• Smartphone user interface (UI) may vary
depending on the mobile operating system
(OS) and the manufacturer.
the security protocol of the router is set to
• IfWEP, you may fail to set up the network.
Please change it to other security protocols
(WPA2 is recommended) and register the
product again.
17
ENGLISH
18
SMART FUNCTIONS
Installing LG SmartThinQ
Search for the LG SmartThinQ application from
the Google Play Store or Apple App Store on a
smart phone. Follow instructions to download
and install the application.
Wi-Fi Function
• For appliances with the logo
Communicate with the appliance from a smart
phone using the convenient smart features.
Settings
Allows you to set various options on the
appliance and in the application.
NOTE
● If you change your wireless router, Internet
service provider or password, delete the
registered appliance from the LG SmartThinQ
application and register it again.
● The application is subject to change for
appliance improvement purposes without notice
to users
● Functions may vary by model.
Wireless LAN Module
ModelLCW-003
Frequency
Range
Output
Power
(Max)
2412 to 2462 MHz
IEEE 802.11 b : 17.56 dBm
IEEE 802.11 g : 25.53 dBm
IEEE 802.11 n : 25.29 dBm
Smart Diagnosis™ Using a Smart
Phone
Use this function if you need an accurate
diagnosis by an LG Electronics customer
information center when the appliance
malfunctions or fails.
Smart Diagnosis™ can not be activated unless
the appliance is connected to power. If the
appliance is unable to turn on, then
troubleshooting must be done without using
Smart Diagnosis™.
NOTE
Be sure to keep ambient noise to a minimum
or the phone may not correctly receive the
buzzer beeps from the indoor unit.
When connected to the Multi Outdoor unit,
this function may not be supported.