LG LTUC182QLE0 Owner's Manual

ENGLISH
LG Ceiling Cassette-Type Air Conditioner
OWNER'S MANUAL
LG
Visit us at http://www.lgservice.com
• Please read this owner's manual carefully and thoroughly before installing and operating your room air conditioner.
• Please retain this owner's manual for future reference after reading it thoroughly.
ESPAÑOL PORTUGUÊS
Dear Owner Thank you for installing LG Air Conditioner. Your best choice guarantees you a great performance and service to make your life comfortable & pleasant.
MODELS: LTNH182QLE0 / LTUH182QLE0
LTNH242PLE0 / LTUH242PLE0 LTNH302PLE0 / LTUH302PLE0 LTNH362NLE0 / LTUH362NLE0 LTNH482MLE0 / LTUH482MLE0 LTNH602MLE0 / LTUH602MLE0 LTNC182QLE0 / LTUC182QLE0 LTNC242PLE0 / LTUC242PLE0 LTNC302PLE0 / LTUC302PLE0 LTNC362NLE0 / LTUC362NLE0 LTNC482MLE0 / LTUC482MLE0 LTNC602MLE0 / LTUC602MLE0
2 Ceiling Cassette-Type Air Conditioner
Ceiling Cassette- Type Air Conditioner Owner’s Manual
TABLE OF CONTENTS
FOR YOUR RECORDS
Write the model and serial numbers here:
Model #
Serial #
You can find them on a label on the side of each unit.
Dealer's Name
Date Purchased
Staple your receipt to this page in the event you need it to prove date of purchase or for warranty issues.
READ THIS MANUAL
Inside you will find many helpful hints on how to use and maintain your air conditioner properly. Just a little preventive care on your part can save you a great deal of time and money over the life of your air conditioner.
You'll find many answers to common problems in the chart of troubleshooting tips. If you review our chart of
Troubleshooting Tips first, you may not need to call for service at all.
PRECAUTION
Contact the authorized service technician for repair or maintenance of this unit.
• Contact the installer for installation of this unit.
• The air conditioner is not intended for use by young children or invalids without supervision.
• Young children should be supervised to ensure that they do not play with the air conditioner.
• When the power cord is to be replaced, replacement work shall be performed by authorized personnel only using only genuine replacement parts.
• Installation work must be performed in accordance with the National Electric Code by qualified and authorized personnel only.
A. Safety Precautions .......................3
B. Product Introduction....................6
1. Name and function of parts .......6
2. What to do before operation......6
3. Operation Indication Lamps ......7
B. Operating Instructions.................8
1. How to insert the Batteries ........8
2. Wireless Remote Controller
Maintenance..............................8
3. Operating Method......................8
4. Wireless Remote Controller ......9
C. How to use the Mode Selection
Button..........................................10
1. Cooling Operation ...................10
2. Auto Operation .......................11
3. Auto changeover operation
(Heat pump model only) ..........12
4. Healthy Dehumidification
Operation................................13
5. Heating Operation
(Heat pump model only) ..........14
6. Jet Cool Operation ..................15
7. NANO PLASMA Purification
Operation (Optional)................16
8. 2nd F Operation ......................17
9. Additional features...................18
10. Setting the Central-Control
Address .................................21
D. Maintenance and Service ..........22
1. Indoor Unit...............................22
2. Purifying filter(Optional)...........23
3. Operation Tips!........................24
4. Troubleshooting Tips! Save
time and money!.....................25
5. Call the service immediately
in the following situations ........25
Safety Precautions
Owner's Manual 3
ENGLISH
Safety Precautions
To prevent injury to the user or other people and property damage, the following instructions must be followed.
Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is classified by the following indications.
This symbol indicates the possibility of death or serious injury.
This symbol indicates the possibility of injury or damage.
WARNING
Always ground the product.
• There is a risk of electric shock.
Do not use a defective or underrated circuit breaker. Use the correctly rated breaker and fuse.
• There is risk of fire or electric shock .
Do not use a multi consent. Always use this appliance on a dedicated cicuit and breaker.
• Otherwise it can cause electric shock or fire.
For electrical work, contact the dealer, seller, a qualified electrician, or an Authorized Service Center. Do not disassemble or repair the product by yourself.
• There is risk of fire or electric shock.
Always ground the product as per the wiring diagram. Do not connect the ground wire to gas or water pipes lightening rod or telephone ground wire.
• There is risk of fire or electric shock.
Install the panel and the cover of control box securely.
• There is risk of fire or electric shock due to dust , water etc.
Use the correctly rated breaker or fuse.
• There is risk of fire or electric shock.
Do not modify or extend the power cable. If the power cable or cord has scrathes or skin peeled off or deteriorated then it must be replaced.
• There is risk of fire or electric shock.
For installation, removal or reinstall , always contact the dealer or an Authorized Service Center.
• There is risk of fire, electric shock, explosion, or injury.
Do not install the product on a defective installation stand. Be sure that the installation area does not deteriorate with age.
• It may cause product to fall.
Never install the outdoor unit on a moving base or a place from where it can fall down.
• The falling outdoor unit can cause damage or injury or even death of a person.
When the product is soaked (flooded or submerged) in water , contact an Authorized Service Center for repair before using it again.
• There is risk of fire or eletric shock.
Be sure to check the refrigerant to the used. Please read the label on the product.
• Incorrect refrigerant used can prevent the normal operation of the unit.
Don't use a power cord, a plug or a loose socket which is damaged.
• Otherwise it may cause a fire or electrical shock.
Do not touch , operate, or repair the product with wet hands. Hold the plug by hand when taking out
• There is risk of electric shock or fire.
Do not place a heater or other heating appliances near the power cable.
• There is risk of fire and electric shock.
Do not allow water to run into electric parts. Install the unit away from water sources.
• There is risk of fire, failure of the product, or electric shock.
Do not store or use or even allow flammable gas or combustibles near the product.
• There is risk of fire.
WARNING
CAUTION
Safety Precautions
4 Ceiling Cassette-Type Air Conditioner
Indoor/outdoor wiring connections must be secured tightly and the cable should be routed properly so that there is no force pulling the cable from the connection terminals.
• Improper or loose connections can cause heat generation or fire.
Safely dispose off the packing materials. Like screws, nails, batteries, broken things etc after installation or svc and then tear away and thraw away the plastic packaging bags.
• Children may play with them and cause injury.
Make sure to check that the power cable plug is not dirty, loose or broken and then only insert the plug completely.
• Dirty, loose or broken power plug can cause electric shock or fire.
Do not use the product in a tightly closed space for a long time. Perform ventilation regularly.
• Oxygen deficiency could occur and hence harm your health.
Do not open the front grille of the product during operation. (Do not touch the electrostatic filter, if the unit is so equipped.)
• There is risk of physical injury, electric shock, or product failure.
If strange sounds, smell or smoke comes from product.Immediately turn the breaker off or disconnect the power supply cable.
• There is risk of electric shock or fire.
Ventilate the product room from time to time when operating it together with a stove, or heating element etc.
• Oxygen deficiency can occur and hence harm your health.
Turn the main power off and unplug the unit when cleaning or repairing the product.
• There is risk of electric shock.
When the product is not to be used for a long time, disconnect the power supply plug or turn off the breaker.
• There is risk of product damage or failure, or unintended operation.
Take care to ensure that nobody especially kids could step on or fall onto the outdoor unit.
• This could result in personal injury and product damage.
Take care to ensure that power cable could not be pulled out or damaged during operation.
• There is risk of fire or electric shock.
Do not place ANYTHING on the power cable.
• There is risk of fire or electric shock.
Do not plug or unplug the power supply plug to turn the unit ON/OFF .
• There is risk of fire or electric shock.
When flammable gas leaks, turn off the gas and open a window for ventilation before turn the product on.
• Do not use the telephone or turn switches on or off. There is risk of explosion or fire.
CAUTION
Two or more people must lift and transport the product.
• Avoid personal injury.
Do not install the product where it will be exposed to sea wind (salt spray) directly.
• It may cause corrosion on the product.
Install the drain hose to ensure that the condensed water is drained away properly.
• A bad connection may cause water leakage.
Keep level even when installing the product.
• To avoid vibration or noise.
Do not install the product where the noise or hot air from the outdoor unit could damage or disturb the neighborhoods.
• It may cause a problem for your neighbors and hence dispute.
Always check for gas (refrigerant) leakage after installation or repair of product.
• Low refrigerant levels may cause failure of product.
In outdoor unit the step-up capacitor supplies high voltage electricity to the electrical components. Be sure to discharge the capacitor completely before conducting the repair work.
• An charged capacitor can cause electrical shock.
When installing the unit, use the installation kit provided with the product.
• Otherwise the unit may fall and cause severe injury.
Be sure to use only those parts which are listed in the svc parts list. Never attempt to modify the equipment.
• The use of inappropriate parts can cause an electrical shock, excessive heat generation or fire.
Safety Precautions
Owner's Manual 5
ENGLISH
Do not use the product for special purposes, such as preserving foods, works of art, etc. It is a consumer air conditioner, not a precision refrigeration system.
• There is risk of damage or loss of property.
Do not block the inlet or outlet of air flow.
• It may cause product failure.
Use a soft cloth to clean. Do not use harsh detergents, solvents or splashing water etc .
• There is risk of fire, electric shock, or damage to the plastic parts of the product.
Do not touch the metal parts of the product when removing the air filter.
• There is risk of personal injury.
Do not step on or put anyting on the product. (outdoor units)
• There is risk of personal injury and failure of product.
Always insert the filter securely after cleaning. Clean the filter every two weeks or more often if necessary.
• A dirty filter reduces the efficiency.
Do not insert hands or other objects through the air inlet or outlet while the product is operating.
• There are sharp and moving parts that could cause personal injury.
Be cautious when unpacking and installing the product.
• Sharp edges could cause injury.
If the refrigerant gas leaks during the repair, do not touch the leakaing refrigerant gas.
• The refrigernat gas can cause frostbite (cold burn)
Do not tilt the unit when removing or uninstalling it.
• The condensed water inside can spill .
Do not mix air or gas other than the specified refrigerant used in the system .
• If air enters the refrigerant system, an excessively high pressure results, causing equipment damage or injury.
If the refrigerant gas leaks during the installation, ventilate the area immediately.
• Otherwise it can be harmfull for your health.
Dismantling the unit, treatment of the refrigerant oil and eventual parts should be done in accordance with local and national standards.
Replace the all batteries in the remote control with new ones of the same type. Do not mix old and new batteries or different types of batteries.
• There is risk of fire or product failure.
Do not recharge or disassemble the batteries. Do not dispose off batteries in a fire.
• They may burn or explode.
If the liquid from the batteries gets onto your skin or clothes, wash it well with clean water. Do not use the remote if the batteries have leaked.
• The chemicals in batteries could cause burns or other health hazards.
If you eat the liquid from the batteries, brush your teeth and see doctor. Do not use the remote if the batteries have leaked.
• The chemicals in batteries could cause burns or other health hazard.
Do not let the air conditioner run for a long time when the humidity is very high and a door or a window is left open.
• Moisture may condense and wet or damage furniture.
Do not expose your skin or kids or plants to the cool or hot air draft.
• This could harm to your health.
Do not drink the water drained from the product.
• It is not sanitary and could cause serious health issues.
Use a firm stool or ladder when cleaning, maintaining or repairing the product at an height.
• Be careful and avoid personal injury.
6 Ceiling Cassette-Type Air Conditioner
Product Introduction
Product Introduction
1: Indoor unit 2: Outdoor unit 3: Remote controller 4: Inlet air 5: Discharge air 6: Refrigerant piping, connection
electric wire 7: Drain pipe 8: Ground wire
Wire to ground outdoor unit to
prevent electrical shocks.
If your installation has a customized control system, ask your LG dealer for
the operation that corresponds to your system.
A: Pair system or simultaneous
operation system B: Multi system 1: Unit with remote controller 2: Unit without remote controller (when
used as simultaneous operation)
* Wire remote controler : accessory
3
6
7
2
8
1
5
44
A
B
12
1
1
4
Name and function of parts
What to do before operation
Owner's Manual 7
ENGLISH
Product Introduction
Operation Indication Lamps
Forced operation : Operation procedures when remote control can t be used. Defrost Mode : Lights up during defrost mode or hot start operation.
(heat pump model only) Timer : Lights up during timer operation. Signal Receptor : Receives the signal from remote control (signal receiving sound:
two short beeps and one long beep) Filter sign : Lights up after 2400 hours from the time of first operation. On/Off : Lights up during system operation.
Operating Instructions
8 Ceiling Cassette-Type Air Conditioner
Operating Instructions
How to insert the Batteries
Wireless Remote Controller Maintenance
1. Remove the battery cover by pulling it according to the arrow direction.
2. Insert new batteries making sure that the (+) and (-) of battery are installed correctly.
3. Reattach the cover by sliding it back into position.
1. Always use/replace both batteries of same type.
2. If the system is not to be used for a long time, remove the batteries to save their working life.
3. If the display screen of remote controller starts, fading replace both of the batteries.
4. Use 2 AAA(1.5 volt) batteries.
NOTICE
1.
Choose a suitable place where its safe & easy to reach.
2. Fix the holder to wall etc with the supplied screws firmly.
3. Slide the remote controller inside the holder.
1. Remote controller should never be exposed to direct sunlight.
2. Signal transmitter & receiver should always be clean for proper communication. Use a soft cloth to clean them.
3. In case some other appliances also get operated with remote control, change their position or consult your serviceman.
1. The signal receiver is inside the unit.
2.
Aim the remote controller towards the unit to operate it. There should not be any blockage in between.
NOTICE
Operating Method
Operating Instructions
Owner's Manual 9
ENGLISH
Wireless Remote Controller
1. Start/Stop Button
Operation starts when this button is pressed.
2. Operation Mode Selection Button
Used to select the operation mode.
3. Room Temperature Setting Buttons
Used to select the room temperature.
4. Indoor Fan Speed Selector
Used to select fan speed in four steps low, medium, high and Chaos.
5. Jet Cool
Speed cooling/heating operates super high fan speed.
6. Chaos Swing Button
Used to stop or start louver movement and set the desired up/down airflow direction.
7. On/Off Timer Buttons
Used to set the time of starting and stopping operation.
8. Time Setting Button
Used to adjust the time.
9. Timer Set/Cancel Button
Used to set the timer when the desired time is obtained and to cancel the Timer operation.
10. Sleep Mode Auto Button
Used to set Sleep Mode Auto operation.
11. Air Circulation Button
Used to circulate the room air without cooling or heating.
12. Room Temperature Button
Used to set the desired horizontal airflow direction.
13. Plasma
Used to start or stop the plasma-purification function.
14. Horizontal Airflow Direction Control Button
Used to set the desired horizontal airflow direction.
15. Reset Button
Initialize remote controller.
16. 2nd F Button
Used prior to using modes printed in blue at the bottom of buttons.
17. Auto Clean
Used to set Auto Clean mode.
To use the functions printed in blue at the bottom of the buttons press 2
nd
F button first and then the required function button. Pressing the 2ndF button activates the blue printed function of the respective button. To cancel the function press the 2ndF button again else it will automatically cancel if remains idle after 10 seconds.
The wireless remote controller do not operate "14.Horzontal Airflow Direction Control Button" and "17.Auto Clean"
Modes for 4Way ceiling cassette type.
NOTE
Signal transmitter
5 6
4
2 7
11
8 13 14 15
1
3
CANCEL
OFF
SET
AUTO CLEAN
ON
10
9
17
12
16
Flip-up door (opened)
Operation Mode
Cooling Operation
Auto Operation or Auto Changeover
Healthy Dehumidification Operation
Heating Operation
Cooling Model( ), Heat Pump Model( )
Loading...
+ 18 hidden pages