SINGLE SPLIT WALL MOUNTED AIR CONDITIONER
1. Type "A" screw
2. Installation Plate
3. Type "B" screw
4. Holder Remote Control
(Left and right
More than
10cm(3.9in)
More than
10cm(3.9in)
More than 70cm(27.6in)
More than
60cm(23.6in)
More than
10cm(3.9in)
Installation plate Sleeve Bushing-Sleeve
Putty(Gum Type Sealer)
Bend the pipe as closely on the wall as possible, but be careful that it doesn't break.
Installation parts you must purchase
Vinyl tape (Wide)
• Apply after carrying out a drainage test.
• To carry out the drainage test, remove the air filters and pour water into the heat exchanger.
Saddle
More than
12cm(4.7in)
More than
30cm(11.8in)
Gas side piping Liquid side piping Additional drain pipe
Vinyl tape (Narrow) Connecting cable:
Heat pump: 4 strands Cooling only:
4 strands
Power connecting cable:
Heat pump: 3 strands Cooling only:
3 strands
Air filter
P/No. :3828A20169Q
(M/N-Series)
• Please read this instruction sheet completely before installing the product.
• When the power cord is damaged, replacement work shall be performed by authorized personnel only.
• Installation work must be performed in accordance with the national wiring standards by authorized personnel only.
Installation Parts Provided
• This illustration is for explanation purposes only.
• The indoor unit will actually face a different way.
• Copper lines must be insulated independently.
INSTALLATION OVERVIEW
2
The following should be always observed for safety
....................
3
Installation of indoor, outdoor unit
................................................
9
Flaring work and connection of piping
.........................................
11
Connection of piping(Indoor)
....
13
For left rear piping For right rear piping Connection of piping(Outdoor)
................................................
17
Connecting the cable between indoor unit and outdoor unit
......
....................................................
18
Checking the drainage and Forming the piping
..................
20
Air purging
...............................
23
Charging
...................................
24
Test running
.............................
25
Installation plateFour type "A" screwsConnecting cable
Pipes: Suction line
................
5/8"
Evaporator line
..........
3/8"
(Refer to page 9)
Insulation materialsAdditional drain pipe
(
Outer Diameter
....
15.5mm(0.61in))
Two type "B" screws
Level gaugeScrew driverElectric drillHole core drill(ø70mm(2.76in))
Flaring tool setSpecified torque wrenches
4.2kg.m, 6.6kg.m (different depending on model No.) (Refer to page 14)
Spanner......................Half union
A glass of waterScrew driver
Hexagonal
wrench(4mm(0.16in))
Gas-leak detectorVacuum pumpGauge manifold
Owner's manualThermometerHolder Remote Control
Installation
Requirements
Required Parts Required Tools
Installation Parts Provided
1. Type "A" screw
2. Installation Plate
3. Type "B" screw
4. Holder Remote Control
ENGLISH
THE FOLLOWING SHOULD BE ALWAYS OBSERVED FOR SAFETY
3
To prevent the injury of the user or other people and property damage, the following instructions must be followed.
Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is classified by the following indications.
This symbol indicates the possibility of death or serious injury.
This symbol indicates the possibility of injury or damage to properties only.
Be sure not to do.
Be sure to follow the instruction.
The meanings of the symbols used in this manual are as shown below.
Installation
Do not use damaged power cords, plugs, or a loose socket.
There is risk of fire or electric
shock.
For electrical work, contact the dealer, seller, a qualified electrician, or an Authorized Service Center.
There is risk of fire or electric shock.
Always use the power plug and socket with the ground terminal.
There is risk of electric shock.
Install the panel and the cover of control box securely.
There is risk of fire or electric shock.
Do not modify or extend the power cord.
There is risk of fire or electric shock.
Do not install, remove, or re-install the unit by yourself (customer).
There is risk of fire, electric shock, explosion or injury.
4
Be cautious when unpacking and installing the product.
Shape edges could cause injury. Be especially careful of the sharp edges.
For installation, always contact the dealer or an Authorized Service Center.
There is risk of fire, electric shock, explosion, or injury.
Do not install the product on a defective installation stand.
It may cause injury, accident, or damage to the product.
Be sure the installation area does not deteriorate with age.
If the base collapses, the air conditioner could fall with it, causing property damage, product failure, and personal injury.
Take care to ensure that power cords could not be pulled out or damaged during operation.
There is risk of fire or electric shock.
Do not place anything on the power cord.
There is risk of fire or electric shock.
Operation
Do not turn the air-conditioner ON or OFF by plugging or unplugging the power plug.
There is risk of fire or electric shock.
Use a dedicated outlet for this appliance.
There is risk of fire or electric shock.
Grasp the plug to remove the cord from the outlet. Do not touch it with wet hands.
There is risk of fire or electric shock.
5
ENGLISH
Do not place a heater or other appliances near the power cable.
There is risk of fire, failure of the product, and/or electric shock.
Do not allow water to run into electric part.
There is risk of fire, failure of the product, and/or electric shock.
Do not store of use flammable gas or combustibles near the air conditioner.
There is risk of fire or failure of product.
Do not use the product in a tightly closed space for a long time.
Oxygen deficiency could occur.
When flammable gas leaks, turn off the gas and open a window for ventilation before turn the product on. Do not use the telephone or turn switches on or off.
There is risk of explosion or fire.
Unplug the unit if strange sounds odors, or smoke comes from it.
There is risk of fire, failure of the product, and/or electric shock.
Stop operation and close the window in storm or hurricane. If possible, remove the air conditioner from the window before the hurricane arrives.
There is risk of property damage, failure of product, or electric shock.
Do not open the inlet grill of the product during operation. (Do not touch the electrostatic filter, if the unit is so equipped.)
There is risk of physical injury, electric shock, or product.
When the product is soaked (flooded or submerged), contact an Authorized Service Center.
There is risk of electrical shock.
Thinner
Wax
6
Ventilate the product from time to time when operating it together with a stove, etc.
There is risk of fire or electrical shock.
Unplug the appliance before performing cleaning or maintenance.
There is risk of electric shock.
When the product is not be used for a long time disconnect the power supply plug or turn off the breaker.
There is risk of product damage or failure, or unintended operation.
Take care to ensure that nobody could step on or fall onto the outdoor unit.
There could result in personal injury and product damage.
Installation
Always check for gas(refrigerant) leakage after installation or repair of product.
Low refrigerant levels may cause failure of product.
Install the drain hose to ensure that water is drained away properly.
A bad connection may cause water leakage.
Keep level even when installing the product.
To avoid vibration or water leakage.
90˚
7
ENGLISH
Do not install the product where the noise or hot air from the outdoor unit could damage the neighborhoods.
It may cause a problem for your neighbors.
Use two or more people to lift and transport the air conditioner
Avoid personal injury.
Do not install the product where it will be exposed to sea wind (salt spray) directly.
It may cause corrosion in the product. Corrosion, particularly on the condenser and evaporator fins, could cause product malfunction or inefficient operation.
Do not direct airflow at room occupants.(Don't sit in the draft.)
This could damage your health.
Do not use the product for special purposes, such as preserving foods, works of art, etc. It is a consumer air conditioner, not a precision refrigeration system.
There is risk of damage or loss of property.
Do not block the inlet or outlet of air flow.
It may cause product failure.
Use a soft clothe to clean. Do not use harsh detergents, solvents, etc.
There is risk of fire, electric shock or damage to the plastic parts of the product.
Do not touch the metal parts of the product when removing the air filter. They are very sharp!
There is risk of personal injury.
Do not step on or put anything on the product. (outdoor unit)
There is risk of personal injury and failure of product.
Operation
8
Always insert the filter securely. Clean the filter every two weeks or more often if necessary.
A dirty filter reduces the efficiency of the air conditioner and could cause product malfunction or damage.
Do not insert hands or other objects through the air inlet or outlet while the air conditioner is plugged in.
There are sharp and moving parts that could cause personal injury.
Do not drink the water drained from the unit.
It is not sanitary and could cause serious health issues.
Use a firm stool or ladder when cleaning or maintaining the air conditioner.
Be careful and avoid personal injury.
Replace all the batteries in the remote.
There is risk of fire or explosion.
Disuse
Do not recharge or disassemble the batteries. Do not dispose of batteries in a fire.
They may burn or explode.
If the liquid from the batteries gets onto your skin or clothes, wash it well with clean water. Do not use the remote if the batteries have leaked.
The chemicals in batteries could cause burns or other health hazards.