LG LNU3220R, LND3220R Owner’s Manual

OWNER’S MANUAL
Network Camera
Please read this manual carefully before operating your set and retain it for future reference.
MODELS LND3110R LNU3110R
LND3210R LNU3210R
LND3220R LNU3220R
1501 (V3.0)
Contents
Introduction ................................................................................... 3
Operation and settings ................................................................. 4
Before using the system .....................................................................4
Recommended PC Requirements ...................................................4
Accessing the LG IP device.................................................................5
LG Smart Web Viewer Overview ......................................................6
Conguration menu overview ..........................................7
Conguring the LG Network Camera Device ..............................7
Accessing the Conguration menu .................................7
System settings .......................................................................8
Audio & Video settings ......................................................10
Network settings ................................................................. 14
User settings ......................................................................... 18
Event settings ....................................................................... 19
Reference .....................................................................................23
Troubleshooting .................................................................................23
OPEN SOURCE SOFTWARE NOTICE ..............................................24
Specications.......................................................................................25

Introduction

The LG Network Camera is designed to use on an Ethernet network and must be assigned an IP address to make it accessible.
This manual contains instructions on how to install and manage the LG Network Camera in your networking environment. Some knowledge of networking environments would be beneficial to the reader.
Note that design and specification of this unit may change from the manual as quality and improvement without prior notice. Should you require any technical assistance, please contact authorized service center.
Introduction 3

Operation and settings

Before using the system

• Before using the LG IP device make sure the connections are correct and verify whether proper power supply is used.
• Check the connections of the LG IP device for the correct conditions.
• Check that the LG IP device is(are) connected to the network and that power is supplied.
• Once the connections are made you need to install the LG client program to the PC from which you want to access the device. The LG Smart Web Viewer program is automatically installed when you connect the LG IP device. The LVi510 and the LG Smart Web Viewer program are the network program of the LG Video Server and the LG IP cameras.
• To view streaming video in Internet Explorer, set your browser to allow ActiveX controls. If you find this message “This website wants to install the following add-on: ‘IPCam_Streamer.cab’ from ‘LG ELECTRONICS INC’”, Click the yellow bar and install LG Smart Web Viewer Program on your computer. Please set your browser zoom level to 100%.
• The Layouts and the Live view pages may differ with different OS (Operating Systems) and Web Browsers.
• Care needs to be taken not to run any other applications when the Client Program is running as it may cause memory shortage.
• When you set on 30 fps in mobile applications, may be degraded the frame rate depending on mobile performance.

Recommended PC Requirements

The LG IP device can be used with most standard operating systems and browsers.
Items Requirements
Operating System
CPU
Web Browser
DirectX
Memory 2 GB or above RAM
Graphics Card 256 MB or above Video RAM
Resolution 2048 x 1536 (with 32 bit color) or higher
Note:
For Windows 7, please download & install ‘DirectX End-User Runtime Web Installer’. “http://www.microsoft.com/en-us/download/details.aspx?id=35”
Windows XP Professional, Windows VISTA, Windows 7
Intel Core2 Quad Q6700 (2.66 GHz) or above
Microsoft Internet Explorer (32 bit) above the version 7.0 and below the version 9.0.
DirectX 9.0c (Windows XP), DirectX 11 (Windows Vista / 7) or above
4 Operation and settings

Accessing the LG IP device

You can access the LG IP device by following the below steps.
1. Install LVi510 Program
It recommended to use LVi510 surely.
Otherwise, it is required to install the IP Utility [Package>Tools>LG IP Utility Installer] to search the IP addresses of LG IP devices.
2. Discover the LG IP device using the IP Utility
The IP Utility can automatically discover and display LG IP devices on your network.
The IP Utility shows the MAC address, IP address, Model name and so on.
Note:
The computer running the IP Utility must be on the same network segment (physical subnet) as the LG IP device.
2.1 Run the IP Utility program.
2.2 Click the [Search] button or select the [Search] option in the Device search menu. After a few seconds the found LG IP devices gets displayed in the IP Utility window.
3. Logging in to the LG Smart Web Viewer
3.1 Run the IP Utility and find the LG IP devices.
3.2 When the LG IP devices appear in the IP Utility window, double-click IP address or right click on the same IP address and select “Connect to Web Page” to start the LG Smart Web Viewer. When accessing the LG Smart Web Viewer, the authentication dialog appears on the screen.
3.3 Enter the user name and password. (Note that the default administrator user name and password are “admin”.)
Note:
Default password must be changed for security after initial connection.
3.4 Click the [OK] button and then the LG Smart Web Viewer is displayed in your browser.
Note:
• You can also access the LG Smart Web Viewer as shown
below.
3.1 Start your Web browser.
3.2 Enter the IP address of the LG IP device in the address bar of the browse.
3.3 Enter the user name and password set by the administrator.
3.4 Click the [OK] button and then the LG Smart Web Viewer is displayed in your browser.
• If LG Smart Web Viewer is required to be updated, it needs more time to display according to the network conditions.
• If the login window is not displayed, check the pop-up blocker. If you set the pop-up blocker, the login window is not displayed. You must allow the pop-ups.
• If you connect the LG Smart Web Viewer for the first time, the Security Warning window is displayed to install the LG Smart Web Viewer program. You must install the LG Smart Web Viewer program for using the LG IP device.
• If your computer or network is protected by a proxy or firewall, the proxy or firewall settings can prevent the LG Smart Web Viewer program. Change the proxy or firewall settings to activate the LG Smart Web Viewer program.
Operation and settings 5

LG Smart Web Viewer Overview

Item Description
Select the video image size from the drop-down list. (FULL SCREEN / AUTO RESIZE / 1920 x 1080 / 1280 x 720 / D1 / CIF) The initial view size is set to AUTO RESIZE.
Note:
• Select [FULL SCREEN] to enlarge full screen of monitor. To return previous screen, press ESC key or double click.
• When you select [AUTO RESIZE], size of live view screen fit to window. Ratio imaging is fixed by width based.
It displays Video Codec, Resolution and FPS of the selected video stream.
Check this option as the network connection type (TCP or UDP). If you check it, the client connects to the server using TCP connection.
Select buffering time of live stream.
Click to display the check box of [Hostname], [Framerate] and [Bitrate] options. [Display] is displayed on left top of the live view window in order of selecting options. (Top Left / Top Right)
Video Analysis
> Hide: Video Analysis display
function is not in use.
> SVA: Displays the Smart Video
Analysis function to the live view window.
> MD: Displays the Motion
Detection function to the live view window.
Note:
When you use the digital PTZ function, all of Display function is deactivated for a while.
Click to effect and then check the check box of [Edge Enhancement] option. The user gets more sharp reception on the live view window.
Note:
This feature only affects the live view window.
Click to save the current image in JPEG format on your computer.
1. Click the [Snapshot] button and then the Snapshot window is displayed.
2. Click the [Save] button in the Snapshot window.
3. Enter the file name (JPEG format) and select the folder to save it.
4. Click the [Save] button to confirm it.
5. Click the [Cancel] button in the Snapshot window to close it.
Note:
It is not displayed the area of MD and SVA in Snapshot file.
Select the video stream. From the Live view drop-down list, select the desired video image source.
Profile1(HD), Profile2(SD), Profile3(JPEG), Profile4(ROI-1), Profile5(ROI-2), Profile6(ROI-3), Profile7(ROI-4)
Note:
You can set the stream configurations independently. This would facilitate the user to set the live view at his comfort.
Provides all the necessary tools for setting up the device to your requirements. The user will need administrator level to do this.
Note:
If you want to exit the Configuration menu, select one of the video stream in the Live view drop-down list or click LG Smart IP Device icon.
Displays the current surveillance live screen. You can monitor the camera image on the live view window of the LG Smart Web Viewer.
Click this button and drag the area to use digital PTZ function. Right-clicking the screen will bring up the previous magnification.
(Color icon: On, Gray scale icon: Off.)
6 Operation and settings
1. Click this button to open the folder browse window. Click the button again in next time, video is recorded automatically without selection of folder.
Note:
If you want to change the folder, move to other pages or press the refresh button.
2. Recording button is activated and recording will be started.
Note:
If recording exceed the time(1 hour) or size limit (1 GB), recording is stopped automatically with warning.
3. To stop the recording, click this button during the recording.
Conguration menu overview
The following table shows the list of menu items.
The configuration images are different from each model.
Main Menu Sub Menu
Version
Date & Time
System
Audio & Video
Network
User Basic
Event
Maintenance
Log & Report
Language
Camera
Stream
Basic
RTP stream
TCP/IP
DDNS
IP filtering
SNMP
QoS
802.1x
Event server
Motion detect
Smart Analytics
Triggered Event
Scheduled Event
Conguring the LG Network Camera Device
The features and options of the LG IP camera are configured through the Configuration menu.
Only administrator-level users have permission to access the Configuration menu.
Accessing the Conguration menu
Click the [Configuration] button to display the LG Smart Web Viewer configuration window.
Warning
The Configuration setup should be made by qualified service personnel or system installers.
Operation and settings 7

System settings

Version
Displays the current Model Name and Software version.
Note:
Click OSS(Open source software) link to check the information about Open source software. Refer to the [OPEN SOURCE SOFTWARE NOTICE] of [Reference].
Date & Time
Time zone
Set the time difference from GMT in the area where the IP device is installed. Select the time zone in the area where the IP device is installed from the drop down list.
Time mode
> Synchronize with NTP Server: Select if you want to
synchronize the IP device’s date and time with those of the time server called NTP (Network Time Protocol). Specify the NTP server’s name. Click the [Test] button for connection test to the server.
> Synchronize with personal computer: Select if you want
to synchronize the IP device’s date and time with your computer.
> Synchronize manually: Select if you want to set the IP
device’s date and time manually. Select the year, month and date by clicking the calendar button. Set hour, minutes and seconds in the edit boxes.
Note:
• When system reboot after time setting, time of system could be delayed. If you set the time correctly, set the [Synchronize with NTP server] option.
• Refer to NTP configuration as operation system of the Recording Server when the Recording Server use recording function and NTP server.
Server time
> Server time: Displays the current date and time of the IP
device.
• Save: Click this button to confirm the settings.
Maintenance
System reboot
Click the [Reboot] button to restart the IP device. It takes some minutes for the IP device to start again.
Backup & Restore
> Backup: To take a backup all of the settings. If necessary, it
make possible to return to a backup configuration.
1. Click the [Backup] button.
2. Click the [Save] button.
3. Follow the instructions on the browser to specify the folder.
4. Click the [Save] button to save the settings.
> Restore:
1. Click the [Browse] button.
2. Find and open the file in which the configuration setting data is stored.
3. Click the [Restore] button and the system settings will be restored and reboot the system.
Note:
Backup and Restore can happen on IP device having the same version of firmware. This feature is not intended for multi-configurations or for firmware upgrades.
Firmware
> Upgrade
1. Click the [Browse] button.
2. Find and open the firmware file.
3. Click the [Upgrade] button to update the firmware.
Note:
When you upgrade the system, it may take some minutes to be done. Do not close the browser while the upgrade is in progress. If you close the browser, it may cause a malfunction. You should wait until the confirmation window is displayed. When the upgrade is finished, the confirmation window will be displayed.
> Initialize: The [Initialize] button should be used with caution.
Clicking it will return all of the IP device’s settings to the factory default values. Except for the Network settings, PTZ Protocol and Preset settings. (The option depends on the model.)
Note:
Refer the “Clear browser’s cache” of Troubleshooting.
8 Operation and settings
Log & Report
Log & Report status
The System log provides a summary of the status of the IP device. The unit records the data of the software activity in a file.
> View Log: Click this button to display the system log
information.
- Download: Click this button to see the log information of system.
> View report: Click this button to display the report of the
system.
- Download: Click this button to see the report information of system.
Note:
The downloaded file is a UNIX type. If you open the file in Microsoft Note pad, it will display the text as if the file contained no line breaks at all.
Language
Language list
Select a language for the LG Smart Web Viewer configuration menu and information display.
• Save: Click this button to confirm the settings.
Operation and settings 9

Audio & Video settings

Camera
Preview
You can preview the camera image on the preview window.
Note:
The option depends on the model.
Install
> Capture Mode (LND3110R / LNU3110R only): Select the
capture mode.
Note:
If the Capture Mode, Mirror or V-Flip settings are changed in the Install menu, the Privacy Mask is initialized.
Capture Mode Resolution
16:9 1280 x 720
4:3 or 5:4 1280 x 1024
> Sensor Framerate: Select the Sensor Framerate value.
Note:
• When you change the value of [Sensor Framerate], Flickerless value in [Exposure] menu is changed as below.
Sensor Framerate Flickerless
30 fps 60 Hz 25 fps 50 Hz
• FPS maximum value cannot exceed the value of Sensor Framerate.
> D-Effect: You can select the digital effect.
- Mirror: Turn on the mirror effect.
- V-Flip: Flip the picture vertically.
Note:
The [Mirror] and [V-Flip] function can be selected at once.
• Save: Click this button to confirm the settings.
• Default: Click this button to restore the IP device back to original
factory settings.
Exposure
> BLC: Camera’s backlight compensation feature helps
alleviate issues of visibility in high contrast areas.
> Dynamic Range Enhancer: Adjusts the contrast of the image
to provides bright and clear images.
> AGC: If the images are too dark, change the maximum [AGC]
value to make the images bright.
> Brightness: Adjust the brightness of images.
> Shutter Speed: Select the desired shutter speed for camera
exposure. You can change the shutter speed to higher speed to capture fast-moving subjects, though the image becomes darker.
1/10 000 1/5 000 1/2 500 1/1 500 1/1 000
Minimum
Shutter
Maximum
Shutter
> Flickerless: Remove the band noise caused by fluorescent
light.
Note:
Flickerles’s default value is changed by [Sensor Framerate] setting. (30 fps » 60 Hz / 25 fps » 50 Hz)
• Default: Click this button to restore the IP device back to original factory settings.
1/700 1/500 1/480 1/400 1/360
1/300 1/250 1/240 1/180 1/150
1/120 1/100 1/60 1/50 1/30
1/25
1/10 000 1/5 000 1/2 500 1/1 500 1/1 000
1/700 1/500 1/480 1/400 1/360
1/300 1/250 1/240 1/180 1/150
1/120 1/100 1/60 1/50 1/30
1/25 1/20 1/15 1/8 1/4
1/2 2/3 1 1.5
10 Operation and settings
Loading...
+ 21 hidden pages