TABLE OF CONTENTS
1. Safety Precautions
2. Operating Instructions
3. Care and Maintenance
4. Hardware Installation
5. Common Issues
Write the model and serial numbers here:
Model # Serial #
You can find them on a label on the side of each unit.
Dealer's Name Date Purchased
Inside you will find many helpful hints on how to use and maintain your air conditioner properly. Just a little preventive care on your part can save you a great deal of time and money over the life of your air conditioner. You'll find many answers to common problems in the chart of troubleshooting tips. If you review our chart of Troubleshooting Tips first, you may not need to call for service at all.
• Contact the authorized service technician for repair or maintenance of this unit.
• Contact the installer for installation of this unit.
• The air conditioner is not intended for use by young children or invalids without supervision.
• Young children should be supervised to ensure that they do not play with the air conditioner.
WARNING
WARNING
WARNING CAUTION
Never Do This
Always Do This
Precautions
Safety Precautions
3
ENGLISH
To prevent injury and property damage, follow these instructions. Incorrect operation due to ignoring instructions will cause harm or damage, the seriousness of which is indicated by the following symbols.
The following items are classified by these symbols.
Plug in the power plug properly.
Do not operate or stop the unit by inserting or pulling out the power plug.
Do not damage or use an unspecified power cord.
• Otherwise, it will cause electric shock or fire due to heat generation or electric shock.
• It will cause electric shock or fire due to heat generation.
• It will cause electric shock or fire.
If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard. (Y attachment)
Do not modify power cord length or share the outlet with other appliances.
Do not operate with wet hands or in damp environment.
Always plug into a grounded outlet.
• It will cause electric shock or fire due to heat generation.
• It will cause electric shock.
• No grounding may cause electric shock (See Installation Manual).
Do not allow water to run into electric parts.
Always install air leakage breaker and a dedicated switching board.
Unplug the unit if strange sounds, odors, or smoke comes from it.
• It will cause failure of machine or electric shock.
• No installation may cause fire and electric shock accident.
• It may cause fire and electric shock accident.
Do not use the socket if it is loose or damaged.
Do not open the entrance during operation.
Keep firearms away.
• It may cause fire and electric shock.
• It may cause electric shock. • It may cause fire.
Do not use the power cord close to the heating tools.
Do not use the power cord near flammable gas or combustibles such as gasoline, benzene, thinner, etc.
• It may cause fire and electric shock. • It may cause an explosion or fire.
This symbol shows the possibility of death or serious injury.
This symbol indicates the possibility of injury or damage to property.
CAUTION
CAUTION
WARNING
WARNING
4
Never touch the metal parts of the unit when removing the filter.
Do not clean the air conditioner with water.
Ventilate well when used together with a stove, etc.
• They are sharp and may cause injury.
• Water may enter the unit and degrade the insulation. It may cause an electric shock.
• An oxygen shortage may occur.
When cleaning the unit, first make sure the power and breaker are turned off.
Do not put a pet or house plant where it will be exposed to direct air flow.
Do not use appliance for special purpose such as animals or vegetables, precision machine, or conservation of art articles.
• Since the fan rotates at high speed during operation, it may cause injury.
• This could injure the pet or plant. • It may cause damage of animals or vegetables or loss of property.
Stop operation in storm or hurricanes.
Hold the plug by the head when taking it out.
Turn off the main power switch when not using it for a long time.
• Operation with windows opened may cause wetting of indoor and soaking of household furniture.
• It may cause electric shock and damage.
• It may cause failure of product or fire.
Do not place obstacles around the absorption inlet or output.
Ensure that an installation console of the outdoor appliance is not damaged due to the use for a long time.
Always insert the filters securely. Clean it every two weeks.
• It may cause failure of appliance or accident.
• If leaving appliance damaged, there is concern of damage due to the falling of product.
• Operation without filters will cause failure.
Do not use strong detergent such as wax or thinner but use a soft cloth.
Do not place heavy object on the power cord and take care so that the cord should not be pressed.
Do not drink water drained from air conditioner.
• Appearance may be deteriorated due to change of product color or scratching of its surface.
• There is danger of fire or electric shock.
• It contains containments and will make you sick.
Ventilate before operating air conditioner when gas goes out.
Do not disassemble or modify products randomly.
• It may cause explosion, fire, and burn. • It may cause failure and electric shock.
If water enters the product, turn off the the power switch of the main body of appliance. Contact service center after taking the power-plug out from the socket.
Do not direct airflow at room occupants only.
• This could damage your health.
Prior to Operation
Safety Precautions
5
ENGLISH
Preparing for operation
Contact an installation specialist for installation. Plug in the power plug properly. Do not share the same outlet with other appliances Do not use an extension cord. Do not start/stop operation by plugging/unplugging the power cord. If cord/plug is damaged, replace only with an authorized part.
6
5
4
3
2
1
Usage
Being exposed to direct airflow for an extended period of time could be hazardous to your health. Do not
expose occupants, pets, or plants to direct airflow for extended periods of time.
Due to the possibility of oxygen deficiency, ventilate the room when used together with stoves or other
heating devices.
Do not use this air conditioner for non-specified special purposes (e.g. preserving precision devices,
food, pets, plants, and art objects). Usage in such a manner could harm such property.
3
2
1
Cleaning and maintenance
Do not touch the metal parts of the unit when removing the filter. Injuries can occur when handling sharp
metal edges.
Do not use water to clean inside the air conditioner. Exposure to water can destroy the insulation, leading
to possible electric shock.
When cleaning the unit, first make sure that the power and breaker are turned off. The fan rotates at a
very high speed during operation. There is a possibility of injury if the unit’s power is accidentally
triggered on while cleaning inner parts of the unit.
3
2
1
Service
For repair and maintenance, contact your authorized service dealer.
6
About the Controls on the Air Conditioner
Operating Instructions
Remote Control OperationsControlsControls
Remote Control OperationsControlsFunction
• CAUTION
When the air conditioner has been performing its cooling operation and is turned off or set to the fan position, wait at least 3 minutes before resetting to the cooling operation again.
- Turns air conditioner off.
- Med speed fan operation without cooling.
- Low speed fan operation without cooling.
- Cooling with high speed fan operation.
- Cooling with med speed fan operation.
- Cooling with low speed fan operation.
This automatically controls the temperature of the indoor air. Turn the knob so that arrow point to the higher number for greater cooling.
Point the arrow to the lower number for more moderate cooling. (i.e. the higher number the greater cooling)
• FOR NORMAL COOLING
1. Turn the MODE Knob to the HI COOL from the LOW COOL setting.
2. Set the TEMP control to the desired temperature mark (the mid-point is a good starting position). If the room temperature is not satisfactory after a reasonable time, adjust the control to a cooler or warmer setting, as appropriate.
• FOR QUIETER OPERATION
1. Turn the MODE Knob to the LOW COOL setting.
2. Set the TEMP control as needed.
• FOR MAXIMUM COOLING
1. Turn the MODE Knob to the HI COOL setting.
2. Set the TEMP control to the highest temperature mark.