LG KSNC1865NA7 Owner’s Manual

OWNER’S MANUAL

AIR CONDITIONER

Please read this manual carefully before

operating your set and retain it for future reference.

TYPE : WALL MOUNTED

<![if ! IE]>

<![endif]>PORTUGUESEENG FRANCAISGE ENGLISH

P/No: 5401 156167 Rev .:

www.lg.com

2 TIPS FOR SAVING ENERGY

<![if ! IE]>

<![endif]>ENGLISH

TIPs FOR SAVING ENERGY

Here are some tips that will help you to minimize the power consumption when you use the air conditioner. You can use your air conditioner more efficiently by referring to the instructions

below :

Do not cool the indoor excessively. This may be harmful for your health and may consume more electricity.

Block sunlight with blinds or curtains while you are operating the air conditioner.

Keep doors or windows closed tightly while you are operating the air conditioner.

Adjust the direction of the air flow vertically or horizontally to circulate indoor air.

Speed up the fan to cool or warm indoor air quickly, in a short period of time.

Open windows regularly for ventilation as the indoor air quality may deteriorate if the air conditioner is used for many hours.

Clean the air filter once every 2 weeks. Dust and impurities collected in the air filter may block the air flow or weaken the cooling / dehumidifying functions.

For your records

Staple your receipt to this page in case you need it to prove the date of purchase or for warranty purposes. Write the model number and the serial number here:

Model number :

Serial number :

You can find them on a label on the side of each unit.

Dealer’s name :

Date of purchase :

IMPORTANT SAFETY INSTRUCTIONS

3

IMPORTANT SAFETY INSTRUCTIONS

READ ALL INSTRUCTIONS BEFORE USING THE APPLIANCE.

Always comply with the following precautions to avoid dangerous situation and ensure peak performance of you product.

!WARNING

It can result in serious injury or death when the directions are ignored.

!CAUTION

It can result in minor injury or product damage when the directions are ignored.

!WARNING

Installation or repairs made by unqualified persons can result in hazards to you and others.

Air conditioner shall be installed in accordance with national wiring regulations.

The information contained in the manual is intended for use qualified service technician familiar with safety procedures and equipped with the proper tools and test instruments.

Failure to carefully read and follow all instructions in this manual can result in equipment malfunction, property damage, personal injury and/or death.

Thisapplianceisnotintendforusebypersons(includingchildren)withreducedphysical,senaryor mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for theirs safety.

Children should be supervised to ensure that they do not play with the appliance.

When the power cord is to be replaced,replacement work shall be performed by authorized personnel only genuine replacement parts.

Installation

Use a standard circuit breaker and fuse conforming with the rating of the air conditioner. Failure to do so may result in electric shock or product failure.

Contact an authorized service center when you install or relocate the air conditioner. Failure to do so may result in serious injury or product failure.

Always use a power plug and socket with a ground terminal. Failure to do so may result in electric shock or product failure.

Installthepanelandthecoverofthecontrolboxsafely.Failuretodosomayresultinexplosionorfire.

Install a dedicated electric outlet and circuit breaker before you use the air conditioner. Failure to do so may result in electric shock or product failure.

Do not modify or extend the power cable.If the power cable or cord has scratches or skin peeled off or deteriorated then it must be replaced. It may result in fire or electric shock.

Be cautious when you unpack or install the air conditioner. Failure to do so may result in serious injury or product failure.

Do not install the air conditioner on an unstable surface or where there may be a danger of it falling. It may result in death, serious injury, or product failure.

<![if ! IE]>

<![endif]>ENGLISH

4 IMPORTANT SAFETY INSTRUCTIONS

<![if ! IE]>

<![endif]>ENGLISH

Operation

Do not let the air conditioner run for a long time when the humidity is very high or when a door or window has been left open. Failure to do so may result in product failure.

Make sure that the power cord is not pulled or damaged while the air conditioner is operating. Failure to do so may result in fire, electric shock, or product failure.

Do not place any objects on the power cord. It may result in electric shock or product failure.

Do not turn on or off the air conditioner by plugging in or unplugging the power plug. It may result in fire or electric shock.

Do not touch, operate or repair the air conditioner with wet hands. It may result in electric shock or product failure.

Do not place a heater or other heating appliances near the power cable. It may result in fire, electric shock, or product failure.

Do not allow water to run into the air conditioner. It may result in explosion or fire.

Do not leave flammable substances such as gasoline, benzene and thinner near the air conditioner. It may result in explosion or fire.

Do not use the air conditioner for an extended period of time in a small place without ventilation. Ventilate the place regularly. Failure to do so may result in explosion or fire.

When there is a gas leak, ventilate sufficiently before using the air conditioner again. Failure to do so may result in explosion or fire.

Unplug the power plug if there is a noise, smell or smoke coming from the air conditioner. Failure to do so may result in explosion or fire.

Stop operating and close the window in storm or hurricane. If possible remove the product from the window before hurricane arrives.

Do not touch the electrostatic filter after opening the front grille. Failure to do so may result in electric shock or product failure.

Contactanauthorizedservicecenterwhentheairconditionerissubmergedintowaterduetoflooding. Failure to do so may result in explosion or fire.

Be cautious water could not enter the product.

Make sure to ventilate sufficiently when this air conditioner and a heating appliance such as a heater are used simultaneously. Failure to do so may result in explosion or fire, serious injury, or product failure.

Turnthemainpoweroffandunplugthepowerplugwhenyoucleanorrepairtheairconditioner.Failure to do so may result in death, serious injury, or product failure.

Unplug the power plug when the air conditioner is not used for an extended period of time. Failure to do so may result in product failure.

For inner cleaning, contact an Authorized Service Center or a dealer.

Do not use harsh detergent that causes corrosion or damage on the unit. Harsh detergent may also cause failure of product, fire, or electric shock.

IMPORTANT SAFETY INSTRUCTIONS

5

! CAUTION

<![if ! IE]>

<![endif]>ENGLISH

Installation

 

• Make sure to check if there is a refrigerant leak after you install or repair the air conditioner.

 

Failure to do so may result in product failure.

 

• Install the drain hose properly for smooth drainage of condensed water. Failure to do so may

 

result in product failure.

 

• Keep level even when installing the product.

 

• Install the air conditioner where the noise from the outdoor unit or the exhaust gas will not

 

inconvenience the neighbors. Failure to do so may result in conflict between neighbors.

 

• When transporting the equipment, there should be at least 2 or more people, or a forklift. It

 

may result in serious injury.

 

• Do not install the air conditioner where it will be exposed to sea wind (salt spray) directly.It may

 

result in product failure.

 

Operation

 

• Do not expose people, animals or plants to the cold or hot wind from the air conditioner. It may

 

result in serious injury.

 

• Do not use the product for special purposes, such as preserving foods, works of art, etc. It is

 

a consumer air conditioner, not a precision refrigeration system. It may result in death, fire or

 

electric shock.

 

• Do not block the inlet or outlet of air flow. It may result in explosion or product failure.

 

• Do not use strong cleaning agents or solvents when you clean the air conditioner, or spray water.

 

Use a smooth cloth. It may result in serious injury or product failure.

 

• Never touch the metal parts of the air conditioner when you remove the air filter. It may result

 

serious injury or product failure.

 

• Do not place any objects on the air conditioner. It may result in product failure.

 

• Always insert the filter securely after cleaning. Clean the filter every two weeks or more often

 

if necessary.

 

• Do not insert hands or other objects through the air inlet or outlet while the air conditioner is

 

operating. It may result in electric shock.

 

•Donotdrinkthewaterdrainedfromtheairconditioner.Itmayresultinserioushealthcomplications.

 

• Use a sturdy stool or ladder when you clean, maintain or repair the air conditioner at a height.

 

Failure to do so may result in serious injury or product failure.

 

•Donotmixthebatteriesfortheremotecontrolwithothertypesofbatteriesormixnewbatteries

 

with used batteries. Failure to do so may result in product failure.

 

• Do not recharge or disassemble the batteries. Failure to do so may result in explosion, fire or

 

serious injury.

 

•Stopusingtheremotecontrolifthereisabatteryfluidleak.Ifyourclothorskinisexplosiontothe

 

battery fluid from a leak, wash it off with clean water. Failure to do so may result in serious injury.

 

• If you swallow the battery fluid from a leak. Wash out the inside of your mouth thoroughly and

 

then consult a doctor. Failure to do so may result in serious health complications.

 

6 CONTENTS

<![if ! IE]>

<![endif]>ENGLISH

Contents

2TIPs FOR SAVING ENERGY

3IMPORTANT SAFETY INSTRUCTIONS

7

BEFORE USE

 

 

7

Components

7

- Indoor unit TYPE 1

7- OUTdoor unit TYPE 1

8- Indoor unit Type 2

8- OUTdoor unit Type 2

9 Inserting batteries

9Installing the remote control holder

9Operating method

10USING THE REMOTE CONTROL

10Wireless remote control

11BASIC FUNCTIONS

11Cooling your room (Cooling operation)

11Removing humidity (Dehumidifying operation)

12Adjusting the fan speed

12 Adjusting the air flow direction

12 Setting the timer

12 Cancel the timer setting

13 ADVANCED FUNCTIONS

13Changing room temperature quickly

(Jet Cool)

14Operating the air conditioner without the remote control

14Restarting the air conditioner automatically

14- Disabling auto restart

15MAINTENANCE

16Cleaning the air filter

16Cleaning Triple filter (optional)

17TROUBLESHOOTING

17 Self-diagnosis function

17 Before requesting service

BEFORE USE

Components

 

 

 

 

Indoor unit

 

 

Air inlet

TYPE 1

Front cover

Air filter

 

 

 

 

 

 

 

 

 

 

BEFORE USE

7

<![if ! IE]>

<![endif]>ENGLISH

Triple filter

Air outlet

LED display

Vertical louver Horizontal vane

*The feature can be changed according a type of model.

On/Off button

Signal receiver

!NOTE

The number of operation lamps and their locations may vary, depending on the model of the air conditioner.

OUTdoor unit

Air inlet

 

 

 

 

Connecting wires

 

 

 

 

 

 

 

 

 

 

 

 

Air outlet

Piping

Drain hose

Base plate

*The feature can be changed according a type of model.

8 BEFORE USE

<![if ! IE]>

<![endif]>ENGLISH

Indoor unit

Air inlet

Type 2

 

 

Air filter

 

Front cover

On/Off button

Signal receiver

Triple filter

Air outlet

LED display Horizontal vane

Vertical louver

*The feature can be changed according a type of model.

!NOTE

The number of operation lamps and their locations may vary, depending on the model of the air conditioner.

OUTdoor unit

Air inlet

 

 

 

 

Connecting wires

 

 

 

 

 

 

 

 

 

 

 

 

Air outlet

Piping

Drain hose

Base plate

*The feature can be changed according a type of model.

BEFORE USE

9

Inserting batteries

Insert batteries before using the remote control. The battery type used is AAA (1.5 V).

1.Remove the battery cover.

2.Insertthenewbatteriesandmakesurethatthe

(+) and (-) terminals of the batteries are installed correctly.

3. Reattach the battery cover.

!NOTE

If the display screen of the remote control starts to fade, replace the batteries.

Installing the remote control holder

Install the holder where there is no direct sunlight to protect the remote control.

1. Choose a safe and easily-accessible place.

2. Fix the holder by fastening the 2 screws firmly with a screwdriver.

3. Slide the remote control into the holder.

Operating method

Point the remote control towards the signal receiver at the bottom of the air conditioner to operate it.

*The feature can be changed according a type of model.

!NOTE

Theremotecontrolmayoperateotherelectronic devices if pointed towards them. Make sure to point the remote control towards the signal receiver of the air conditioner.

For proper operation, use a soft cloth to clean the signal transmitter and receiver.

<![if ! IE]>

<![endif]>ENGLISH

LG KSNC1865NA7 Owner’s Manual

10 USING THE REMOTE CONTROL

<![if ! IE]>

<![endif]>ENGLISH

USING THE REMOTE CONTROL

You can operate the air conditioner more conveniently with the remote control.

Wireless remote control

Control

Display

Description

panel

screen

 

 

-

On/Off button : TurnthepowerOn/Off.

 

C

Temperature adjustment buttons :

Display

 

Adjust the room temperature when

 

cooling.

screen

 

 

 

 

 

Operation mode selection button :

 

 

Select the operation mode.

Control

 

Cooling operation ( )

panel

 

Dehumidifying operation ( )

 

 

Jet cool button : Cools down the

 

 

indoor temperature within a short

 

 

period of time.

 

 

Indoor fan speed button : Adjust

 

 

the fan speed.

 

-

Air flow direction button : Adjust

 

the air flow direction vertically.

 

 

 

 

Off timer button : Set up automatic off

 

-

Timer clear button : Cancel timer

 

setting

 

 

*Some functions may not be supported, depending on the model.

BASIC FUNCTIONS

11

BASIC FUNCTIONS

Cooling your room (Cooling operation)

1.Press to turn on the power.

2.Press repeatedly to select the cooling operation.

- is displayed on the display screen.

3. Pressor to set the desired temperature. - The temperature range is 18°C - 30°C.

Removing humidity (Dehumidifying operation)

Thismoderemovesexcessmoisturefromanenvironmentwithhighhumidityorintherainyseason, in order to prevent mold. This mode adjusts the room temperature and the fan speed automatically to maintain the optimal level of humidity.

1.Press to turn on the power.

2.Press repeatedly to select the dehumidifying operation.

- is displayed on the display screen.

!NOTE

In this mode you cannot adjust the room temperature, as it is adjusted automatically. Also, the room temperature is not displayed on the display screen.

<![if ! IE]>

<![endif]>ENGLISH

12 BASIC FUNCTIONS

<![if ! IE]>

<![endif]>ENGLISH

Adjusting the fan speed

1. Press to adjust the fan speed.

 

 

 

 

 

 

 

Remark

Speed

 

 

 

High

 

 

 

 

 

 

 

Medium

 

 

 

 

 

 

 

Low

 

 

 

 

 

 

 

Natural wind

 

 

 

 

 

 

.

 

Setting the timer

Use the off timer mode to turn off the air conditioner automatically.

1.Press to turn on the power.

2.Press repeatedly to select the hour you want to turn air conditioner off (Up to 7 hours). The hour increases automatically with long press. -is displayed on the display screen.

Adjusting the air flow direction

Cancel the timer setting

1. To adjust the direction of the air flow verti-

1. Press

to cancel all timer setting.

cally, press

change the air flow direction

 

 

automatically.

!NOTE

Adjustingtheairdeflectorarbitrarilymaycause product failure.

Ifyourestarttheairconditioner,itstartstooperate with the previously set direction of air flow.

ADVANCED FUNCTIONS

The air conditioner offers some additional advanced functions.

Changing room temperature quickly (Jet Cool)

This mode allows you to cool indoor air quickly in summer.

1.Press to turn on the power.

2.Press

- In jet cooling mode, strong air blows out at a temperature of 18°C for 30 minutes.

ADVANCED FUNCTIONS

13

<![if ! IE]>

<![endif]>ENGLISH

14 ADVANCED FUNCTIONS

<![if ! IE]>

<![endif]>ENGLISH

Operating the air conditioner without the remote control

You can use the On/Off button of the indoor unit to operation the air conditioner when the remote control is unavailable. However, the fan speed is set to high.

1. Open the front cover.

- Lift up both side of the cover slightly.

Type 1

Type 2

*The feature can be changed according a type of model.

2. Press the On/Off button.

Type 1

Type 2

On/off

On/Off

button

button

*The feature can be changed according a type of model.

-Forcoolingandheatingmodel,theoperationmode changes, depending on the room temperature.

Room Temp.

Set Temp.

Operation mode

Below 21°C

24°C

Heating opera-

 

 

tion

 

 

 

Above 21°C

23°C

Dehumidifying

and below

 

operation

24°C

 

 

 

 

 

Above 24°C

22°C

Cooling opera-

 

 

tion

 

 

 

- For cooling only model, the temperature is set to 22°C.

Restarting the air conditioner automatically

When the air conditioner is turned on again after apowerfailure,thisfunctionrestorestheprevious settings. This function is a factory default setting.

Disabling auto restart

1. Open the front cover.

- Lift up both side of the cover slightly.

Type 1

Type 2

*The feature can be changed according a type of model.

2.PresstheOn/Offbuttonandholditfor6seconds. - The unit will beep twice and the lamp will blink

6 times.

Type 1

Type 2

On/Off

On/Off

button

button

*The feature can be changed according a type of model.

-Tore-enablethefunction,presstheOn/Offbutton and hold it for 6 seconds. The unit will beep twice and the blue lamp will blink 4 times.

!NOTE

IfyoupressandholdtheOn/Offbuttonfor3-5 seconds,theunitwillswitchtothetestoperation. In the test operation, the unit blows out strong air for cooling for 18 minutes and then returns to the factory default setting.

MAINTENANCE 15

MAINTENANCE

Clean the product regularly to maintain optimal performance and to prevent possible breakdown.

Type 1

Type 2

 

Air filter

Triple filter

Triple filter

Air filter

* The feature can be changed according a type of model.

Item

Cleaning interval

Cleaning method

Air filter

2 weeks

See “Cleaning Air filter”

 

 

 

Triple filter

3 months

See “Cleaning the Triple filter”

 

 

 

Indoor unit surface

Regularly

Use a soft, dry cloth. Do not

 

 

use bleach or abrasives.

 

 

 

Outdoor unit

Regularly

Use steam to clean the heat

 

 

exchanger coils and the panel

 

 

vents (consult with technician).

!CAUTION

Turnoffthepowerandunplugthepowercordbeforeyouperformanymaintenance;otherwise it may cause electric shock.

Never use water that is hotter than 40°C when you clean the filters. It may cause deformation or discoloration.

Never use volatile substances when you clean the filters. They may damage the surface of the product.

Do not washed the 3M filter with water, because the filter can be damaged.

!NOTE

The location and shape of the filter may differ, depending on the model.

Make sure to clean the heat exchanger coils of the outdoor unit regularly, as dirt collected in the coil may decrease the operational efficiency or increase energy costs.

<![if ! IE]>

<![endif]>ENGLISH

16 MAINTENANCE

<![if ! IE]>

<![endif]>ENGLISH

Cleaning the air filter

CleaningtheAirfilteronceevery2weeksormore if necessary.

1.Turn off the power and unplug the power cord.

2.Open the front cover.

- Lift up both sides of the cover slightly.

Type 1

Type 2

Cleaning Triple filter (optional)

1.Turn off the power and unplug the power cord.

2.Open the front cover and remove Air filter (See “Cleaning Air filter").

3.Pull out the Triple filter.

Type 1

Type 2

* The feature can be changed according a type of model.

3. Hold the knob of the Air filter, lift it up slightly and remove it from the unit.

Type 1

Type 2

* The feature can be changed according a type of model.

4.Clean the filter with a vacuum cleaner or with warm water.

- If dirt is difficult to remove, wash the filter in lukewarm water with detergent.

5.Dry the filter in the shade.

!NOTE

Forinnercleaning,contactanAuthorizedService center or a dealer. Do not use harsh detergent that causes corrosion or damage on the unit. Harsh detergentmayalsocausefailureofproduct,fire, or electric shock.

4. Dry the filer in direct sunlight for 2 hours.

!NOTE

Thelocationandshapeofthefiltersmaydiffer, depend on the model.

TROUBLESHOOTING 17

TROUBLESHOOTING

Self-diagnosis function

Thisproducthasabuilt-inself-diagnosisfunction.Ifanerroroccurs,thelampoftheindoorunitwillblink in 2 seconds intervals. If this occurs, contact your local dealer or service center.

Before requesting service

Please check the following before you contact the service center. If the problem persists, contact your local service center.

Problem

Possible causes

Corrective action

There is a burning smell and a

 

 

strange sound coming from the unit.

 

 

Waterleaksfromtheindoorunit

 

 

even when the humidity level is low.

 

Turnofftheairconditioner,unplug

The power cord is damaged or

-

the power cord and contact the

generating excessive heat.

 

service center.

 

 

 

Aswitch,acircuitbreaker(safety,

 

 

ground) or a fuse is not operated

 

 

properly.

 

 

 

The air conditioner is unplugged.

Check whether the power cord

 

is plugged into the outlet.

 

A fuse is blown or the power

Replace the fuse or check if the

 

supply is blocked.

circuit breaker has tripped.

 

 

Turn off the air conditioner when

Theairconditionerdoesnotworks.

A power failure has occurred.

a power failure occurs. When the

powerisrestored,wait3minutes,

 

 

 

 

and then on the air conditioner.

 

 

 

 

The voltage is too high or too low.

Check if the circuit breaker has

 

tripped.

 

The air conditioner turned off

Press the power button again.

 

automatically at a preset time.

 

<![if ! IE]>

<![endif]>ENGLISH

18 TROUBLESHOOTING

<![if ! IE]>

<![endif]>ENGLISH

Problem

Possible causes

Corrective action

 

 

Makesurethattherearenocur-

 

Air is not circulating properly.

tains,blindsorfurnitureblocking

 

 

the front of the air conditioner.

 

 

Clean the Air filter once every 2

 

The Air filter is dirty.

weeks. See “Cleaning Air filter”

 

 

for more information.

 

 

 

 

 

Insummer,itmaytakesometime

 

The room temperature is too high.

to cool indoor air. In this case,

 

select the jet cool operation to

 

 

cool indoor air quickly.

 

 

Make sure that no cold air is

The air conditioner does not

Cold air is escaping from the room.

escaping through ventilation

generate cool air.

 

points in the room.

The desired temperature is higher

Set the desired temperature to

 

 

than the set temperature.

a level lower than the current

 

temperature.

 

 

 

 

Avoid using a heat generator

 

There is a heating source nearby.

such as an electric oven or a gas

 

burner while the air conditioner

 

 

is in operation.

 

 

 

 

 

In the air circulation operation,

 

 

air blows from the air conditioner

 

Air circulation operation is selected.

without cooling or heating the

 

 

indoor air. Switch the operation

 

 

mode to the cooling operation.

 

 

 

 

 

Insomeoperationmodes,suchas

 

The auto operation, jet opera-

thejetordehumidifyingoperation

It is not possible to adjust the

modes, you cannot adjust the

fan speed.

tion or dehumidifying operation

fan speed. Select an operation

 

is selected.

mode in which you can adjust

 

 

 

 

the fan speed.

 

 

In some operation modes, such

 

 

astheaircirculationorjetopera-

It is not possible to adjust the

The air circulation operation or

tionmode,youcannotadjustthe

temperature.

jet operation is selected.

temperature. Select an operation

 

 

modeinwhichyoucanadjustthe

 

 

temperature.

 

 

 

Loading...
+ 42 hidden pages