LG ABNW24GM1A0 user manuals

Page 1
OWNER’S MANUAL
AIR CONDITIONER
www.lg.com
Please read this manual carefully before operating your set and retain it for future reference.
4 WAY CEILING CASSETTE, CEILING CONCEALED DUCT
MFL67870327
Rev.00_070918
Copyright © 2016 - 2018 LG Electronics Inc. All Rights Reserved.
ENGLISH
ESPAÑOL
Page 2
2
TIPS FOR SAVING ENERGY
ENGLISH
Here are some tips that will help you minimize the power consumption when you use the air conditioner. You can use your air conditioner more efficiently by referring to the instructions below:
• Do not cool excessively indoors. This may be harmful for your health and may consume more electricity.
• Block sunlight with blinds or curtains while you are operating the air conditioner.
• Keep doors or windows closed tightly while you are operating the air conditioner.
• Adjust the direction of the air flow vertically or horizontally to circulate indoor air.
• Speed up the fan to cool or warm indoor air quickly, in a short period of time.
• Open windows regularly for ventilation as the indoor air quality may deteriorate if the air conditioner is used for many hours.
• Clean the air filter once every 2 weeks. Dust and impurities collected in the air filter may block the air flow or weaken the cooling / dehumidifying functions.
For your records
Staple your receipt to this page in case you need it to prove the date of purchase or for warranty purposes. Write the model number and the serial number here:
Model number :
Serial number :
You can find them on a label on the side of each unit.
Dealer’s name :
Date of purchase :
TIPS FOR SAVING ENERGY
Page 3
IMPORTANT SAFETY INSTRUCTIONS
3
ENGLISH
IMPORTANT SAFETY INSTRUCTIONS
READ ALL INSTRUCTIONS BEFORE USING THE APPLIANCE.
Always comply with the following precautions to avoid dangerous situations and ensure peak performance of your product.
WARNING
It can result in serious injury or death when the directions are ignored.
CAUTION
It can result in minor injury or product damage when the directions are ignored. This appliance is intended to be used by expert or trained users in shops, in light industry and on farms, or for commercial use by lay persons.
WARNING
• Always ground the product. There is a risk of electric shock.
• Do not use a defective or underrated circuit breaker. Use the correctly rated breaker and fuse. There is risk of fire or electric shock.
• Do not use a multi consent. Always use this appliance on a dedicated cicuit and breaker. Otherwise it can cause electric shock or fire.
• For electrical work, contact the dealer, seller, a qualified electrician, or an Authorized Service Center. Do not disassemble or repair the product by yourself. There is risk of fire or electric shock.
• Always ground the product as per the wiring diagram. Do not connect the ground wire to gas or water pipes lightening rod or telephone ground wire. There is risk of fire or electric shock.
• Install the panel and the cover of control box securely. There is risk of fire or electric shock due to dust, water etc.
• Use the correctly rated breaker or fuse. There is risk of fire or electric shock.
• Do not modify or extend the power cable. If the power cable or cord has scrathes or skin peeled off or deteriorated then it must be replaced. There is risk of fire or electric shock.
• For installation, removal or reinstall, always contact the dealer or an Authorized Service Center. There is risk of fire, electric shock, explosion, or injury.
• Do not install the product on a defective installation stand. Be sure that the installation area does not deteriorate with age. It may cause product to fall.
• Never install the outdoor unit on a moving base or a place from where it can fall down. The falling outdoor unit can cause damage or injury or even death of a person.
• When the product is soaked (flooded or submerged) in water, contact an Authorized Service Center for repair before using it again. There is risk of fire or eletric shock.
• Be sure to check the refrigerant to the used. Please read the label on the product. Incorrect refrigerant used can prevent the normal operation of the unit.
• Don't use a power cord, a plug or a loose socket which is damaged. Otherwise it may cause a fire or electrical shock.
• Do not touch, operate, or repair the product with wet hands. Hold the plug by hand when taking out. There is risk of electric shock or fire.
• Do not place a heater or other heating appliances near the power cable. There is risk of fire and electric shock.
• Do not allow water to run into electric parts. Install the unit away from water sources. There is risk of fire, failure of the product, or electric shock.
• Do not store or use or even allow flammable gas or combustibles near the product. There is risk of fire.
!
!
!
Page 4
4
IMPORTANT SAFETY INSTRUCTIONS
ENGLISH
• Indoor/outdoor wiring connections must be secured tightly and the cable should be routed properly
so that there is no force pulling the cable from the connection terminals. Improper or loose connections can cause heat generation or fire.
• Safely dispose off the packing materials. Like screws, nails, batteries, broken things etc after
installation or svc and then tear away and thraw away the plastic packaging bags. Children may play with them and cause injury.
• Make sure to check that the power cable plug is not dirty, loose or broken and then only insert the
plug completely. Dirty, loose or broken power plug can cause electric shock or fire.
• In outdoor unit the step-up capacitor supplies high voltage electricity to the electrical components.
Be sure to discharge the capacitor completely before conducting the repair work. An charged capacitor can cause electrical shock.
• When installing the unit, use the installation kit provided with the product. Otherwise the unit may
fall and cause severe injury.
• Be sure to use only those parts which are listed in the svc parts list. Never attempt to modify the
equipment. The use of inappropriate parts can cause an electrical shock, excessive heat generation or fire.
• Do not use the product in a tightly closed space for a long time. Perform ventilation regularly.
Oxygen deficiency could occur and hence harm your health.
• Do not open the front grille of the product during operation. (Do not touch the electrostatic filter, if
the unit is so equipped.) There is risk of physical injury, electric shock, or product failure.
• If strange sounds, smell or smoke comes from product.Immediately turn the breaker off or
disconnect the power supply cable. There is risk of electric shock or fire.
• Ventilate the product room from time to time when operating it together with a stove, or heating
element etc. Oxygen deficiency can occur and hence harm your health.
• Turn the main power off and unplug the unit when cleaning or repairing the product. There is risk of
electric shock.
• When the product is not to be used for a long time, disconnect the power supply plug or turn off the
breaker. There is risk of product damage or failure, or unintended operation.
• Take care to ensure that nobody especially kids could step on or fall onto the outdoor unit. This
could result in personal injury and product damage.
• Take care to ensure that power cable could not be pulled out or damaged during operation. There is
risk of fire or electric shock.
• Do not place anything on the power cable. There is risk of fire or electric shock.
• Do not plug or unplug the power supply plug to turn the unit ON/OFF. There is risk of fire or electric
shock.
• When flammable gas leaks, turn off the gas and open a window for ventilation before turn the
product on. Do not use the telephone or turn switches on or off. There is risk of explosion or fire.
• Do not turn on the breaker or power under condition that front panel, cabinet, top cover, control box
cover are removed or opened. Otherwise, it may cause fire, electric shock, explosion or death.
• Use a vacuum pump or Inert (nitrogen) gas when doing leakage test or air purge. Do not compress
air or Oxygen and Do not use Flammable gases. Otherwise, it may cause fire or explosion. There is the risk of death, injury, fire or explosion.
CAUTION
• Two or more people must lift and transport the product. Avoid personal injury.
• Do not install the product where it will be exposed to sea wind (salt spray) directly. It may cause
corrosion on the product.
• Install the drain hose to ensure that the condensed water is drained away properly. A bad
connection may cause water leakage.
• Keep level even when installing the product. To avoid vibration or noise.
• Do not install the product where the noise or hot air from the outdoor unit could damage or disturb
the neighborhoods. It may cause a problem for your neighbors and hence dispute.
!
Page 5
IMPORTANT SAFETY INSTRUCTIONS
• Always check for gas (refrigerant) leakage after installation or repair of product. Low refrigerant levels may cause failure of product.
• Do not use the product for special purposes, such as preserving foods, works of art, etc. It is a consumer air conditioner, not a precision refrigeration system. There is risk of damage or loss of property.
• Do not block the inlet or outlet of air flow. It may cause product failure.
• Use a soft cloth to clean. Do not use harsh detergents, solvents or splashing water etc. There is risk of fire, electric shock, or damage to the plastic parts of the product.
• Do not touch the metal parts of the product when removing the air filter. There is risk of personal injury.
• Do not step on or put anyting on the product. (outdoor units) There is risk of personal injury and failure of product.
• Always insert the filter securely after cleaning. Clean the filter every two weeks or more often if necessary. A dirty filter reduces the efficiency.
• Do not insert hands or other objects through the air inlet or outlet while the product is operating. There are sharp and moving parts that could cause personal injury.
• Be cautious when unpacking and installing the product. Sharp edges could cause injury.
• If the refrigerant gas leaks during the repair, do not touch the leakaing refrigerant gas. The refrigernat gas can cause frostbite (cold burn)
• Do not tilt the unit when removing or uninstalling it. The condensed water inside can spill.
• Do not mix air or gas other than the specified refrigerant used in the system. If air enters the refrigerant system, an excessively high pressure results, causing equipment damage or injury.
• If the refrigerant gas leaks during the installation, ventilate the area immediately. Otherwise it can be harmfull for your health.
• Dismantling the unit, treatment of the refrigerant oil and eventual parts should be done in accordance with local and national standards.
• Replace the all batteries in the remote control with new ones of the same type. Do not mix old and new batteries or different types of batteries. There is risk of fire or product failure.
• Do not recharge or disassemble the batteries. Do not dispose off batteries in a fire. They may burn or explode.
• If the liquid from the batteries gets onto your skin or clothes, wash it well with clean water. Do not use the remote if the batteries have leaked. The chemicals in batteries could cause burns or other health hazards.
• If you eat the liquid from the batteries, brush your teeth and see doctor. Do not use the remote if the batteries have leaked. The chemicals in batteries could cause burns or other health hazard.
• Do not let the air conditioner run for a long time when the humidity is very high and a door or a window is left open. Moisture may condense and wet or damage furniture.
• Do not expose your skin or kids or plants to the cool or hot air draft. This could harm to your health.
• Do not drink the water drained from the product. It is not sanitary and could cause serious health issues.
• Use a firm stool or ladder when cleaning, maintaining or repairing the product at an height. Be careful and avoid personal injury.
• This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
- Children should be supervised to ensure that they do not play with the appliance.
• This appliance incorporates an earth connection for functional purposes only.
• The appliance shall be installed in accordance with national wiring regulations.
5
ENGLISH
Page 6
6
TABLE OF CONTENTS
ENGLISH
TABLE OF CONTENTS
2 TIPS FOR SAVING ENERGY 3 IMPORTANT SAFETY INSTRUCTIONS 7 BEFORE USE
7
Preparing for operation
7
Usage
7
Cleaning and maintenance
7
Service
8 PRODUCT INTRODUCTION
8
Name and function of parts (4 WAY CEILING CASSETTE)
8
Name and function of parts (CELING CONCEALED DUCT)
9
What to do before operation
9
Operation Indication Lamps
10
Wired Remote Controller
11
Wireless Remote Controller (Accessory)
12 OPERATING INSTRUCTIONS
12
Standard Operation - Standard Cooling
13
Standard Operation - Power Cooling
13
Standard Operation - Heating Mode
14
Standard Operation - Dehumidification Mode
14
Auto Changeover Mode
15
Standard Operation - Fan Mode
16
Standard Operation - Auto Operation Mode
17
Standard Operation - Airflow Setting
18
Standard Operation - Temperature Setting/Room Temperature Check
19
Sub function - Plasma Purification(Accessory)
20
Function setting - Child Lock
21
Function Setting - Change Temp
22
Function setting - Elevation Grill(Accessory)
23
Function setting - Filter Sign Clear
24
Function setting - Vane Angle Control
25
Function setting - Changing Current Time
27
Programming - Simple Reservation
28
Programming : Weekly Reservation
30
Programming - Sleep Reservation
31
Programming - ON Reservation
33
Programming - OFF Reservation
35
Programming : Holiday Reservation
36 MAINTENANCE AND SERVICE
36
Indoor Unit
37
Purifying filter(Optional)
38
Operation Tips!
38
When the air conditioner is not going....
39
Troubleshooting Tips! Save time and money!
39
Call the service immediately in the following situations
Page 7
BEFORE USE
7
ENGLISH
Preparing for operation
• Contact an installation specialist for installation.
• Use a dedicated circuit.
Usage
• Being exposed to direct airflow for an extended period of time could be hazardous to your health. Do not expose occupants, pets, or plants to direct airflow for extended periods of time.
• Due to the possibility of oxygen deficiency, ventilate the room when used together with stoves or other heating devices.
• Do not use this air conditioner for non-specified special purposes (e.g. preserving precision devices, food, pets, plants, and art objects). Such usage could damage the items.
Cleaning and maintenance
• Do not touch the metal parts of the unit when removing the filter. Injuries can occur when handling sharp metal edges.
• Do not use water to clean inside the air conditioner. Exposure to water can destroy the insulation, leading to possible electric shock.
• When cleaning the unit, first make sure that the power and breaker are turned off. The fan rotates at a very high speed during operation. There is a possibility of injury if the unit’s power is accidentally triggered on while cleaning inner parts of the unit.
Service
For repair and maintenance, contact your authorized service dealer.
BEFORE USE
Page 8
8
PRODUCT INTRODUCTION
ENGLISH
Name and function of parts (4 WAY CEILING CASSETTE)
Name and function of parts (CEILING CONCEALED DUCT)
3
7
2
8
6
1
5
4
4
1: Indoor unit 2: Outdoor unit 3: Remote controller 4: Inlet air 5: Discharge air 6: Refrigerant piping, connection electric wire 7: Drain pipe 8: Ground wire
Wire to ground outdoor unit to prevent electrical shocks.
4
2
8
4
5
Remote Controller
3
Air intake vents
1
Air outlet vents
6
7
1: Indoor unit 2: Outdoor unit 3: Remote controller 4: Inlet air 5: Discharge air 6: Refrigerant piping, connection electric wire 7: Drain pipe 8: Ground wire
wire to ground outdoor unit to prevent electrical shocks.
PRODUCT INTRODUCTION
Page 9
PRODUCT INTRODUCTION
9
ENGLISH
What to do before operation
Operation Indication Lamps
4
A
B
1 1
12
If your installation has a customized control system, ask your LG dealer for
the operation that corresponds to your system.
1: Unit with remote controller 2: Unit without remote controller (when used as
simultaneous operation)
: Lights up during the system operation.
Filter Sign : Lights up after 2 400 hours from the time of first operating unit.
Timer : Lights up during Timer operation.
Defrost Mode : Lights up during Defrost Mode or Hot Start operation.(Heat pump model only)
On/Off
Forced
: To operate the unit when the remote control can't be used for any reason.
Page 10
10
PRODUCT INTRODUCTION
ENGLISH
1 OPERATION INDICATION SCREEN 2 SET TEMPERATURE Button 3 FAN SPEED Button 4 ON/OFF Button 5 OPRATION MODE SELECTION Button 6 WIRELESS REMOTE CONTROLLER
RECEIVER
• Some products don't receive the wireless signals.
7 AIR FLOW Button 8 SUBFUNCTION Button 9 FUNCTION SETTING Button 10 VENTILATION Button 11 RESERVATION 12 UP,DOWN,LEFT,RIGHT Button
• To check the indoor temperature, press
button.
13 ROOM TEMPERATURE Button 14 SETTING/CANCEL Button 15 EXIT Button
* Some functions may not be operated and
displayed depending on the product type.
NOTE
!
• Display temperature can be different from actual room temperature if the remote controller is installed at the place where sun-rays are falling directly or the place nearby heat source.
• The actual product can be different from above contents depending upon model type.
• When using simultaneous operation system, whenever press remote controller button, system will approximately operate after 1~2 minutes.
Wired Remote Controller
1
8
7
9
10
11 12
13
15
Please attach the inform label inside of the door. Please choose proper language depend on your country.
14
2
4
5
6
3
Page 11
PRODUCT INTRODUCTION
11
ENGLISH
NOTE
!
• The wireless remote controller do not operate the vane angle control.(4 WAY Type)
• For more details refer to the Wireless Remote Control Accessory manual.
• The actual product can be different from above contents depending upon model type.
• The wireless remote controller does not operate When using simultaneous operation system.
CAUTION
CAUTION of handling the Remote Controller
• Aim at the signal receiver on the wired remote controller so as to operate.
• The remote control signal can be received at a distance of up to about 7 m.
• Be sure that there are no obstructions between the remote controller and the signal receptor.
• Do not drop or throw the remote controller.
• Do not place the remote controller in a location exposed to direct sunlight, or near the heating unit, or any other heat source.
• Block a strong light over the signal receptor with a curtain or etc. so as to prevent the abnormal operation. (ex:electronic quick start, ELBA, inverter type fluorescent lamp)
!
Wireless Remote Controller (Accessory)
This air-conditioner is equipped with wired remote controller basically. But if you want to be available with wireless remote controller, you pay for it.
˚C / ˚F (5 s)
(3 s)
PQWRHQ0FDB
Page 12
12
OPERATING INSTRUCTIONS
ENGLISH
Standard Operation - Standard Cooling
It cools the room by comfortable and clean wind.
* Setting Temp Range : 18 ˚C~30 ˚C (64 ˚F~86 ˚F)
OPERATING INSTRUCTIONS
Press button to turn on the
1
indoor.
Press button to select
2
Cooling operation mode.
Adjust the desired temperature
3
by pressing buttons. Press button to check the Room temperature. When setting the desired temperature higher than room temperature, only ventilation wind is blow out instead of cooling wind.
Page 13
What is Power Cooling?
• Desired temperature: Po (actually 18 °C)
• Wind flow: power wind
• Wind direction: fix to air-cooling position h Partial product has no power air-cooling function.
OPERATING INSTRUCTIONS
13
ENGLISH
It make room temperature drop fast by running
}
Standard Operation - Heating Mode
It supplies warm wind to the indoor.
• Heating drive only operates at the cooling and heating model.
• Heating doesn't operate at cooling exclusive model.
Standard Operation - Power Cooling
It makes the room cool using pleasant and fresh air quickly.
Press button to trun on the
1
indoor.
Press button to select
2
cooling operation mode.
Press button continuously
3
until 'Po' displayed.
Press button to turn on the
1
indoor.
Press button to select
2
Heating mode. (To check the indoor temperature, press the room temperature button.)
Adjust the desired temperature
3
by pressing buttons.
When setting the desired temperature lower than room temperature, there is only ventilation wind.
Page 14
14
OPERATING INSTRUCTIONS
ENGLISH
• In rainy season or high humidity climate, it is possible to operate simultaneously dehumidifier and cooling mode to remove humidity effectively.
• The menu item of wind powerfulness might not be partially selected according to the product.
Auto Changeover Mode
* Setting Temp Range : 18 ˚C~30 ˚C.
Standard Operation - Dehumidification Mode
It removes humidity while air-cooling weakly.
Press button to turn on the
1
indoor.
Press button to select
2
Dehumidification mode. The temperature setting can not be adjusted during operation this mode.
Press the button to select
3
airflow rate feeble weak medium strong automatic. (The initial wind powerfulness of humidity removal drive is 'weak'.)
Press button to turn on the indoor.
1
Press button to select Auto Changeover Mode.
2
The setting temperature as the right side picture can be set in both
3
cooling/ heating model.
Page 15
OPERATING INSTRUCTIONS
15
ENGLISH
Press button to turn on the indoor.
1
Press button to select Fan Mode.
2
Every time pressing button, you can select wind flow in order of feeble weak medium strong automatic. When running ventilation, compressor of AHU doesn't work.
3
• Ventilation drive does not release cool wind but general fan.
• Because it releases the wind that has no temperature difference from the room, it functions to circulate the inside air.
• The menu item of wind powerfulness might not be partially selected according to the product.
Standard Operation - Fan Mode
It blows the air as it is in the indoor, not the cold wind.
Page 16
16
OPERATING INSTRUCTIONS
ENGLISH
Press button to turn on the indoor.
1
Press button to select Artificial intelligence Mode.
2
You can adjust the temperature as the picture on the right for cooling and heating model.
3
For the case of cooling exclusive, as the picture on the right, you can adjust the temperature from hot to cold, from "-2" to "2" based on "00".
4
When cold
When cool
When appropriate
When warm
When hot
During operating Auto Operation mode:
• We can use the FAN SPEED button.
• We can change manually to other operation mode.
Standard Operation - Auto Operation Mode
Page 17
OPERATING INSTRUCTIONS
17
ENGLISH
Standard Operation - Airflow Setting
* Some functions may not be operated and displayed
depending on the product type.
Wind powerfulness : You can simply adjust desired wind powerfulness.
Please setup desired wind
1
powerfulness by wind powerfulness button.
• Every time you press wind powerfulness, you can select the wind flow in order of ‘feeble weak weak medium medium medium strong strong power automatic’.
• The menu item might not be partially selected according to product function.
Wind direction : You can simply adjust desired wind direction.
Please set desired wind direction
1
by pressing button. You can select wind direction of (comfortable wind Up/Down and Right/Left Right/Left Up/Down) by pressing button. Partial item of wind directions might not be selected according to product function.
Page 18
18
OPERATING INSTRUCTIONS
ENGLISH
We can simply adjust the desired temperature.
• Press the buttons to adjust the desired temperature.
: Increase 1 ˚C or 2 ˚F per one time pressing : Decrease 1 ˚C or 2 ˚F per one time pressing
Cooling operation:
- The cooling mode doesn't work if desired temperature is higher than room temperature Please lower the desired temperature.
Heating operation:
- The heating mode doesn't work if desired temperature is lower than room temperature Please increase the desired temperature.
1
Whenever press button, the room temperature will be displayed within 5 seconds. After 5 seconds, it turns to display the desired temperature. Because of location of remote controller, the real room temperature and the this displayed value can be different
1
Temperature Setting
Room Temperature Check
• For air-cooling drive, from 18 °C to 30 °C, and for heating drive, from 16 °C to 30 °C, you can select desired temperature.
• 5 °C is proper for the difference between room and outside temperature.
• Room temp: Indicate the current room temperature.
• Set temp: Indicate the temperature that user want to set.
Standard Operation - Temperature Setting/Room Temperature Check
h
Depend on what kind of controller, the desired temperature can be adjusted at 0.5 ˚C or 1 ˚F.
Page 19
OPERATING INSTRUCTIONS
19
ENGLISH
• Cleaning air function is additional function and it might not be indicated or operated at the partial product.
• Cleaning air function is possible only when product is running.
• If you want independent cleaning air drive, please setup cleaning air by pressing additional drive button at ventilation drive.
* Some functions may not be operated and displayed depending on the product type.
Sub function - Plasma Purification(Accessory)
Only products with humidifying function can use this.
The method to setup cleaning air
Repeat pressing button
1
until icon flash.
Operate or cancel Plasma
2
Purification function by pressing button.
( icon appears/disappears on display part up to selection )
After setting, press button
3
to exit.
After setup, it automatically gets out of setup
mode if there is no button input for 25 seconds.
When exiting without pressing set button, the
manipulated value is not reflected.
Page 20
20
OPERATING INSTRUCTIONS
ENGLISH
Press button repeatedly until the is flashing.
1
If moving to 'setup' icon area by using button, 'setup' icon blinks, and child lock function is setup if pressing button at that time.
2
When cancelling lock function, if moving to 'cancel' icon by pressing button and then, pressing button, child lock function is cancelled.
3
Press button to exit. After setup, it automatically gets out of
setup mode if there is no button input for 25 seconds.
When exiting without pressing set
button, the manipulated value is not reflected.
4
Function setting - Child Lock
It is the function to use preventing children or others from careless using.
Page 21
OPERATING INSTRUCTIONS
21
ENGLISH
Function Setting - Change Temp
Change temperature is the function to setup air-cooling and heating drive automatically changeable according to the temperature at artificial intelligence drive mode.
Repeat pressing button until
1
icon flash.
Press button to change.
2
Converting temp value : 1~7
Press button to complete
3
and active the setting process.
Press button to exit or
4
system will automatically release without any input after 25 seconds. When exiting without pressing
set button, the manipulated value is not reflected.
Page 22
22
OPERATING INSTRUCTIONS
ENGLISH
• Elevation grill function only operates in the indoor unit with the elevation grill.
* Some functions may not be operated and displayed depending on the product type.
Function setting - Elevation Grill(Accessory)
This function is to move the indoor filter up/down for cleaning filter.
1
2
3
4
5
Press button Repeat pressing button until icon flash.
Move to descent using button and press button will display descent icon and the up/down grill will descent.
When up/down grill descents to the desired position, move to stop icon suing button and press button to stop up/down grill.
When filter cleaning is finished, fix the filter to the up/down grill, move to ascent icon using button, and press button to ascent up/down grill.
Press button to exit. After setup, it automatically
gets out of setup mode if there is no button input for 60 seconds.
When exiting without pressing set
button, the manipulated value is not reflected.
Page 23
OPERATING INSTRUCTIONS
23
ENGLISH
• When filter is covered by dust, it will reduce cooling/heating efficiency and accumulate more electric power. Therefore. do clean the filter whenever cleaning time is expired.
* Filter cleaning indication is automatically cancelled without the separate cancellation after certain
period of time.
Function setting - Filter Sign Clear
This function is to clear the indicator of indoor filter cleaning.
Press button repeatedly
1
until the is flashing.
When the is flashing, press
2
the to clear this display
Page 24
24
OPERATING INSTRUCTIONS
ENGLISH
Function setting - Vane Angle Control
This function is to adjust angle at which airflow is blow out. * Some functions may not be operated and displayed depending on the product type.
Repeat pressing button until
1
icon flash.
Press button to select active vane :
2
1 / 2 / 3 / 4 / All / Standard Select Vane number using buttons. Vane number : No. 1, 2., 3, 4, all, or
standard
- Selected vane is in operation.
- Please verify the operating vane.
- To set the angle of all the vanes, select 'all'.
- To set as the factory default settings, select 'standard'.
Select wind angle using button, and
3
press button.
- The boundary of wind angle settings can be changed to 5 levels or 6 levels according to the product.
- When selecting 'standard' for Vane number, the wind angle does not move.
Set the wind angles for the remaining
4
vanes as the same as above. There are products with vanes with
no. 1 and no. 2 only according to the product types.
Press button to exit. After setup, it automatically gets
5
out of setup mode if there is no button input for 60 seconds.
When exiting without pressing set
button, the manipulated value is not reflected.
Press button to complete and
6
active the setting process. (Airflow direction function will be released whenever setting vane angle)
Press button to exit or
7
system will automatically release without any input after 25 seconds.
Page 25
OPERATING INSTRUCTIONS
25
ENGLISH
Function setting - Changing Current Time
Please press function setup
1
button. If pressing function setup button repeatedly, it moves to time setup menu. ‘Time setup’ icon is indicated at that time and date blinks at current time indication area.
Ex) Changing Current Time as 'Monday / AM 10:20'.
Press key to adjust the current
2
day.
Press key to move to AM/ PM setting
3
mode (the 'AM/ PM segment will flash).
Setting AM/ PM value by
4
pressing button.
Press button to move to 'Hour'
5
setting mode. (the 'Hour' segment will flash)
Setting Hour value by pressing
6
button.
Page 26
26
OPERATING INSTRUCTIONS
ENGLISH
Press button to move to 'Minute'
7
setting mode. (the 'Minute' segment will flash)
Setting Minute value by pressing
8
button.
Press button to finish.
9
In the process, press
10
button to release and exit from setting mode. (In case of exit with incomplete information, it will return to the previous setting) When exiting without pressing set
button, the manipulated value is not reflected.
Page 27
OPERATING INSTRUCTIONS
27
ENGLISH
* When simple reservation setup, product automatically runs or stops after the time that is set.
Programming - Simple Reservation
You can set the reservation conveniently in the units of 1 hour from 1 hour to 7 hours.
Press button to enter the
1
Programming mode. (the segment flashing)
Ex) Setting Simple Reservation time as '3'.
Press button to adjust reservation
2
time.
Press button to finish setting.
3
Press button to exit.
4
After setup, it automatically gets out of
setup mode if there is no button input for 25 seconds.
When exiting without pressing set
button, the manipulated value is not reflected.
Page 28
28
OPERATING INSTRUCTIONS
ENGLISH
Please move to 'weekly' by repeatedly pressing reservation button. 'Weekly' blinks at this time.
Please move to reservation setup mode by pressing reservation button. You can setup two weekly reservations for one day, and up to fourteen
reservations for a week. For example, to setup (Tuesday morning 11:30 turned on ~ afternoon 12:30 turned off), you setup in order below.
2
1
Please select weekly reservation or weekly reservation ڸڹ by using button. You can setup two reservations,
weekly reservation 1 and weekly reservation 2, for a day.
3
Please move to 'date' setup part by using button. If 'date' indication blinks, please setup date. You can setup date from Monday to Sunday.
4
Please move to 'AM/PM' setup part of turning on by using button.
5
Please move to 'hour' setup part of turning on by using button.
- It is the part to setup the time at which air-conditioner is turned on.
6
Please move to 'minute' setup part of turning on by using button.
8
Please change time by using button.
- You can setup hour 0~12.
7
If 'minute' indication blinks, please setup 'minute' by using button
9
Programming : Weekly Reservation
You can set the daily reservation in weekly unit. Weekly reservation keeps operating until before you cancel it once you setup.
Page 29
OPERATING INSTRUCTIONS
29
ENGLISH
* Indoor unit is turned on to desired temperature if it is configured using up/down button during preset
of weekly operation time.
(Temperature selection range : 18 °C~30 °C)
- When desired temperature is not set, it is turned on automatically with desired temperature of previous operation.
Please move to 'AM/PM' setup part
10
of turning off by using button.
- AM/PM setup is identical with turning on time setup.
Please move to 'hour' setup part
11
of turning off by using Right button.
- It is the part to reserve the time
at which air-conditioner is turned off.
- If 'hour' indication blinks, please
setup 'hour'.
Please setup 'hour' and 'minute'
identically with the method to setup turning on time.
If finishing weekly reservation setup, please press setup/cancellation button.
12
Weekly reservation setup for the day that you set is finished.
If you setup with the method identical with above by selecting the day that
13
you'd like to setup, it operates weekly reservation. If you setup both turning on reservation time and turning off reservation time identically, it doesn't operate reservation drive.
Weekly reservation explanation
Reservation number
Turning on time
Under bar: the indication that there is weekly reservation for corresponding day
Turning off time
Page 30
30
OPERATING INSTRUCTIONS
ENGLISH
CAUTION
Please reserve proper time at sleeping. (Too much air-cooling is not good for your health.)
• Because it automatically adjusts desired temperature for comfortable air-cooling at sleep drive, there could be difference between remote controller's desired temperature and air-conditioner body's desired temperature.
• Sleep reservation operates as off reservation for the product whose temperature adjustment isn't controlled by unit of 0.5 °C.
!
Programming - Sleep Reservation
Sleep reservation is the function of air-conditioner to run and stop after certain period of time at sleep mode before sleep. When connected to a ventilation product and set the sleep reservation, when it goes to the sleep mode, after the set time has elapsed.
Press button to enter the
1
Programming mode. Ex) Setting Sleep Reservation time as '3'.
Repeat pressing button to enter the
2
SLEEP reservation setting mode. ( segment flashing)
Press button to adjust reservation
3
time. The SLEEP reservation time is from 1 to 7 hours.
Press button to finish setting.
4
Whenever reservation is done.
Press button to exit.
5
After setup, it automatically gets out of
setup mode if there is no button input for 60 seconds.
When exiting without pressing set
button, the manipulated value is not reflected.
- If reservation is setup, 'sleep' indication shows up at the lower part of LCD screen.
If finishing sleep reservation setup,
6
air-conditioner product operates sleep drive and stops after the time that is set.
Page 31
OPERATING INSTRUCTIONS
31
ENGLISH
Programming - ON Reservation
Automatically turned On at reserved time that you set.
Press button.
1
Ex) Setting ON Reservation Time as 'AM 10:20'.
Repeat pressing button to
2
enter the ON reservation setting mode. ( segment flashing)
Press button to adjust AM/ PM
3
setting.
Press button to Hour setting
4
mode. When the Hour icon flash, please setting time. The setting range is within 1~12.
Press button to shift to Minute
5
setting mode. When the Minute icon flash, please setting minute the setting range is within 00~59.
Press button to finish setting.
6
Page 32
32
OPERATING INSTRUCTIONS
ENGLISH
Press button to exit.
7
After setup, it automatically gets out of
setup mode if there is no button input for 25 seconds.
When exiting without pressing set
button, the manipulated value is not reflected.
- If reservation is set, 'turned on' indication shows up at the lower part of LCD screen, and air-conditioner product runs at the time that is set.
- If reservation is cancelled, 'turned on' indication disappears.
Page 33
OPERATING INSTRUCTIONS
33
ENGLISH
Programming - OFF Reservation
Automatically turned Off at reserved time that you set.
1
2
3
4
Press button.
Ex) Setting OFF Reservation Time as 'AM 10:20'.
Repeatedly pressing button to enter the OFF reservation setting mode. ( segment flashing)
Press button to adjust AM/ PM setting.
Press button to shift to Hour setting mode. When the Hour icon flash, please setting time. The setting range is within 1~12.
Press button to shift to Minute
5
setting mode. When the Minute icon flash, please setting minute the setting range is within 00~59.
Press button to finish setting.
6
Page 34
34
OPERATING INSTRUCTIONS
ENGLISH
Press button to exit.
7
After setup, it automatically gets out of
setup mode if there is no button input for 25 seconds.
When exiting without pressing set
button, the manipulated value is not reflected.
- If reservation is set, 'turned off' indication shows up at the lower part of LCD screen, and air-conditioner product runs at the time that is set.
- If reservation is cancelled, 'turned off' indication disappears.
Page 35
OPERATING INSTRUCTIONS
35
ENGLISH
Programming : Holiday Reservation
It automatically stops at reserved day that you set.
Please press button.
1
It enters into reservation setup mode.
Please move to 'holiday' by repeatedly
2
pressing button.
Please move to 'date' that
3
you want to setup holiday by using button.
Please appoint or cancel holiday by using
4
or button. For example, when you setup Monday/Friday to holiday
- 'Monday', 'Friday' letter disappears.
Please press button if finishing
5
holiday setup. If it comes to appointed holiday,
air-conditioner automatically stops. Once you setup holiday appointment, until before you cancel holiday setup, air-conditioner automatically stops within one hour even though you run air-conditioner.
Page 36
Indoor Unit
Grille, Case and Remote Control
- Turn the system off before cleanining, To clean, wipe with a soft, dry cloth. Do not use bleach or abrasives.
The air filters behind the front grille should be checked and cleaned once every 2 weeks or more often if neccessary.
- Never use any of the followings: Water hotter than 40 °C.
Could cause deformation and/or discoloration. Volatile substances.
Could damage the surfaces of the air conditioner.
1 Remove the Air filters.
- Take hold of the tab and pull slightly forward to remove the filters.
2 Clean dirt from the air filters using a vacuum
cleaner or washing with water.
- If dirt is conspicuous, wash with a neutral detergent in lukewarm water.
- If hot water (50 °C or more) is used, it may be deformed.
3 After washing with water, dry well in the
shade.
- Do not expose the air filters to direct sunlight or heat from a fire when drying it.
4 Install the air filters.
CAUTION
Before performing any maintenance, turn off the main power to the system.
!
NOTE
!
Supply power must be disconnected before cleaning the indoor unit.
Air Filters
B
e
n
z
e
n
e
S
C
O
U
R
I
N
G
C
L
B
A
R
G
E
R
G
S
I
N
N
E
R
CAUTION
When the air filters is to be removed, do not touch the metal parts of the indoor unit.
It may cause an injury.
!
MAINTENANCE AND SERVICE
36
MAINTENANCE AND SERVICE
ENGLISH
Air outlet vent
Air filters
Page 37
MAINTENANCE AND SERVICE
37
ENGLISH
Purifying filter(Optional)
The PLASMA filter behind the air filters should be checked and cleaned once every 3 months or more often if necessary.
1 After removing the air filters, pull slightly
forward to remove the PLASMA filter.
2 Dip the PLASMA filter into the water mixed
with neutral detergent, for 20~30 minutes.
3 Dry the PLASMA filter in the shade for a day
(Especially, the humidity must be removed perfectly on this parts).
4 Note the cuts of electric discharge lines. 5 Re-install the PLASMA filter to the original
position.
- Recomended use period : About 2 years
1 Open front panel and remove air filter.
2 Remove air purifying filter.
3 Insert new air purifying filter.
4 Reinsert air filter and close front panel.
Cleaning
CAUTION
Don’t touch this PLASMA Filter within 10 seconds after opening the inlet grille, it may cause an electric shock.
!
Replacement
1
2
Page 38
38
ENGLISH
Do not overcool the room.
This is not good for the health and wastes electricity.
Keep blinds or curtains closed.
Do not let direct sunshine enter the room when the air conditioner is in operation.
Keep the room temperature uniform.
Adjust the vertical and horizontal airflow direction to ensure a uniform temperature in the room.
Make sure that the doors and windows are shut tight.
Avoid opening doors and windows as much as possible to keep the cool air in the room.
Clean the air filter regularly.
Blockages in the air filter reduce the airflow and lower cooling and dehumidifying effects. Clean at least once every two weeks.
Ventilate the room occasionally.
Since windows are kept closed, it is a good idea to open them and ventilate the room now and then.
When the air conditioner is not
going....
When air conditioner is not going to be used for a long time.
1 Operate the air conditioner at the following
settings for 2 to 3 hours.
- Type of operation: Fan operation mode.
- This will dry out the internal mechanisms.
2 Turn off the breaker.
3 Remove the batteries from the Remote
Controller.
Helpful information
The air filters and your electiric bill. If the air filters become clogged with dust, the
cooling capacity will drop, and 6 % of the electricity used to operate the air conditioner will be wasted.
When the air conditioner is to be used again.
1 Clean the air filter and install it in the indoor
unit.
2 Check that the air inlet and outlet of the
indoor/outdoor unit are not blocked.
3 Check that the ground wire is connected
correctly. It may be connect to the indoor unit side.
CAUTION
Turn off the breaker when the air conditioner is not going to be used for a long time. Dirt may collect and may cause a fire.
!
Operation Tips!
MAINTENANCE AND SERVICE
Page 39
39
ENGLISH
MAINTENANCE AND SERVICE
Call the service immediately in the following situations
- Anything abnormal such as burning smell, loud noise etc. happen. Stop the unit and turn the breaker off. Never try to repair by yourself or restart the system in such cases.
- Main power cord is too hot or damaged.
- Error code is generated by self diagnosis.
- Water leaks from indoor unit even if the humidity is low.
- Any switch, breaker (safety, earth) or fuse fails to work properly.
User must carry routine checkup & cleaning to avoid unit’s poor performance.
In case of special situation, the job must be carried out by service person only.
Case Explanation
The air conditioner does not operate.
• Have you made a mistake in timer operation?
• Has the fuse blown or has the circuit breaker been tripped?
The room has a peculiar odor.
• Check that this is not a damp smell exuded by the walls, carpet, furniture or cloth items in the room.
It seems that condensation is leaking from the air conditioner.
• Condensation occurs when the airflow from the air conditioner cools the warm room air.
Air conditioner does not operate for about 3 minutes when restart.
• This is the protector of the mechanism.
• Wait about three minutes and operation will begin.
Does not cool or heat effectively.
• Is the air filter dirty? See air filter cleaning instructions.
• The room may have been very hot when the room air conditioner was first turned on. Allow time for it to cool down.
• Has the setting temperature been set incorrectly?
• Are the indoor unit's air inlet or outlet vents obstructed?
The air conditioner operation is noisy.
• For a noise that sounds like water flowing.
-This is the sound of freon flowing inside the air conditioner unit.
• For a noise that sounds like the compressed air releasing into atmosphere.
-This is the sound of the dehumidifying water being processed inside the air conditioning unit.
Crack sound is heard.
• This sound is generated by the expansion/contraction of the inlet grille, etc. due to changes of temperature.
Remote control display is faint, or no display at all.
• Has the circuit breaker been tripped?
• Are the batteries inserted in the opposite (+) and (-) directions? 
The error code is occurred after lightning struck
• This product has been applied to the over current protection circuit. Error can occur, but it is normal behavior. After few minutes, It will operate normally.
Troubleshooting Tips! Save time and money!
Check the following points before requesting repairs or service.... If the malfunction persist, please
contact your dealer.
Page 40
40
ENGLISH
MAINTENANCE AND SERVICE
Page 41
Loading...