LG ABNQ22GM1A4 INSTALLATION MANUAL

<![if ! IE]>

<![endif]>PORTUGUÊS ESPAÑOL ENGLISH

INSTALLATION MANUAL

AIR

CONDITIONER

Please read this installation manual completely before installing the product. Installation work must be performed in accordance with the national wiring standards by authorized personnel only.

Please retain this installation manual for future reference after reading it thoroughly.

CEILING CONCEALED DUCT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

www.lg.com

 

 

MFL62799907

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rev.00_041619

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Copyright © 2013 - 2019 LG Electronics Inc. All Rights Reserved.

<![if ! IE]>

<![endif]>ENGLISH

2 TIPS FOR SAVING ENERGY

TIPS FOR SAVING ENERGY

Here are some tips that will help you minimize the power consumption when you use the air conditioner. You can use your air conditioner more efficiently by referring to the instructions below:

Do not cool excessively indoors. This may be harmful for your health and may consume more electricity.

Block sunlight with blinds or curtains while you are operating the air conditioner.

Keep doors or windows closed tightly while you are operating the air conditioner.

Adjust the direction of the air flow vertically or horizontally to circulate indoor air.

Speed up the fan to cool or warm indoor air quickly, in a short period of time.

Open windows regularly for ventilation as the indoor air quality may deteriorate if the air conditioner is used for many hours.

Clean the air filter once every 2 weeks. Dust and impurities collected in the air filter may block the air flow or weaken the cooling / dehumidifying functions.

For your records

Staple your receipt to this page in case you need it to prove the date of purchase or for warranty purposes. Write the model number and the serial number here:

Model number :

Serial number :

You can find them on a label on the side of each unit.

Dealer’s name :

Date of purchase :

SAFETY PRECAUTIONS 3

IMPORTANT SAFETY INSTRUCTIONS

READ ALL INSTRUCTIONS BEFORE USING THE APPLIANCE.

Always comply with the following precautions to avoid dangerous situations and ensure peak performance of your product

! WARNING

It can result in serious injury or death when the directions are ignored

! CAUTION

It can result in minor injury or product damage when the directions are ignored

! WARNING

Installation or repairs made by unqualified persons can result in hazards to you and others.

Installation MUST conform with local building codes or, in the absence of local codes, with the Nation Electrical Code NFPA 70/ANSI C1-1003 or current edition and Canadian Electrical Code Part1 CSA C.22.1.

The information contained in the manual is intended for use by a qualified service technician familiar with safety procedures and equipped with the proper tools and test instruments.

Failure to carefully read and follow all instructions in this manual can result in equipment malfunction, property damage, personal injury and/or death.

Installation

Always perform grounding. - Otherwise, it may cause electrical shock.

Don’t use a power cord, a plug or a loose socket which is damaged. - Otherwise, it may cause a fire or electrical shock.

For installation of the product, always contact the service center or a professional installation agency. - Otherwise, it may cause a fire, electrical shock, explosion or injury.

Securely attach the electrical part cover to the indoor unit and the service panel to the outdoor unit.

-If the electrical part cover of the indoor unit and the service panel of the outdoor unit are not attached securely, it could result in a fire or electric shock due to dust, water, etc.

Always install an air leakage breaker and a dedicated switching board. - No installation may cause a fire and electrical shock.

Do not keep or use flammable gases or combustibles near the air conditioner. - Otherwise, it may cause a fire or the failure of product.

Ensure that an installation frame of the outdoor unit is not damaged due to use for a long time.

-It may cause injury or an accident.

Do not disassemble or repair the product randomly. - It will cause a fire or electrical shock.

Do not install the product at a place that there is concern of falling down. - Otherwise, it may result in personal injury.

Use caution when unpacking and installing. - Sharp edges may cause injury.

Do not turn on the breaker or power under condition that front panel, cabinet, top cover, control box cover are removed or opened.

-Otherwise, it may cause fire, electric shock, explosion or death.

Operation

Do not share the outlet with other appliances. - It will cause an electric shock or a fire due to heat generation.

Do not use the damaged power cord. - Otherwise, it may cause a fire or electrical shock.

<![if ! IE]>

<![endif]>ENGLISH

 

4

SAFETY PRECAUTIONS

 

 

<![if ! IE]>

<![endif]>ENGLISH

• Do not modify or extend the power cord randomly. - Otherwise, it may cause a fire or electrical

 

shock.

 

• Take care so that the power cord may not be pulled during operation. - Otherwise, it may cause a

 

fire or electrical shock.

 

• Unplug the unit if strange sounds, smell, or smoke comes from it. - Otherwise, it may cause

 

electrical shock or a fire.

 

• Keep the flames away. - Otherwise, it may cause a fire.

 

• Take the power plug out if necessary, holding the head of the plug and do not touch it with wet

 

hands. - Otherwise, it may cause a fire or electrical shock.

 

• Do not use the power cord near the heating tools. - Otherwise, it may cause a fire and electrical

 

shock.

 

• Do not open the suction inlet of the indoor/outdoor unit during operation. - Otherwise, it may

 

electrical shock and failure.

 

• Do not allow water to run into electrical parts. - Otherwise, it may cause the failure of machine or

 

electrical shock.

 

• Hold the plug by the head when taking it out. - It may cause electric shock and damage.

 

• Never touch the metal parts of the unit when removing the filter. - They are sharp and may cause

 

injury.

 

• Do not step on the indoor/outdoor unit and do not put anything on it. - It may cause an injury through

 

dropping of the unit or falling down.

 

• Do not place a heavy object on the power cord. - Otherwise, it may cause a fire or electrical shock.

 

• When the product is submerged into water, always contact the service center. - Otherwise, it may

 

cause a fire or electrical shock.

 

• Take care so that children may not step on the outdoor unit. - Otherwise, children may be seriously

 

injured due to falling down.

! CAUTION

Installation

Install the drain hose to ensure that drain can be securely done. - Otherwise, it may cause water leakage.

Install the product so that the noise or hot wind from the outdoor unit may not cause any damage to the neighbors. - Otherwise, it may cause dispute with the neighbors.

Always inspect gas leakage after the installation and repair of product. - Otherwise, it may cause the failure of product.

Keep level parallel in installing the product. - Otherwise, it may cause vibration or water leakage.

Operation

Avoid excessive cooling and perform ventilation sometimes. - Otherwise, it may do harm to your health.

Use a soft cloth to clean. Do not use wax, thinner, or a strong detergent. - The appearance of the air conditioner may deteriorate, change color, or develop surface flaws.

Do not use an appliance for special purposes such as preserving animals vegetables, precision machine, or art articles. - Otherwise, it may damage your properties.

Do not place obstacles around the flow inlet or outlet. - Otherwise, it may cause the failure of appliance or an accident.

TABLE OF CONTENTS 5

TABLE OF CONTENTS

2TIPS FOR SAVING ENERGY

3IMPORTANT SAFETY INSTRUCTIONS

6INTRODUCTION

6Features

7INSTALLATION OF INDOOR

7Selection of the best location

7Ceiling dimension and hanging bolt location

9Wiring Connection

11 Indoor Unit Drain Piping

11Drain test

12Heat insulation

13REMOTE CONTROLLER INSTALLATION

14Group Control

16 OPTIONAL OPERATION

16Installer Setting -Test Run Mode

17Installer Setting - Setting Address of Central Control

18Installer Setting -Thermistor

19Installer Setting-Remote Controller Master/Slave Setup

20Installer Setting-Celsius / Fahrenheit Switching

21Installer Setting -E.S.P.

22Installer Setting - Static Pressure Step Setting

27 DIP SWITCH SETTING

<![if ! IE]>

<![endif]>ENGLISH

LG ABNQ22GM1A4 INSTALLATION MANUAL
<![if ! IE]>

<![endif]>ENGLISH

6 INTRODUCTION

INTRODUCTION

Features

Air inlet vents

Air outlet vents

FAN

SPEED

TEMP

OPER

MODE

Remote

Controller

Name

Washer for

Clamp

Insulation for

 

hanging bracket

(Tie Wrap)

fitting

Other

 

Quantity

8 EA

4 EA

1 set

 

• Owner's manual

• Installation manual

Shape

for gas pipe

for liquid pipe

INSTALLATION OF INDOOR

7

 

INSTALLATION OF INDOOR

Selection of the best location

Install the air conditioner in the location that satisfies the following conditions.

-The place shall easily bear a load exceeding four times the indoor unit’s weight.

-The place shall be able to inspect the unit as the figure.

-The place where the unit shall be leveled.

-The place shall easily connect with the outdoor unit.

-The place where the unit is not affected by an electrical noise.

-The place where air circulation in the room will be good .

-There should not be any heat source or steam near the unit

Top view

 

 

 

 

 

 

 

 

 

 

 

 

 

Unit: mm

 

 

 

 

 

 

 

Inspection hole

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

600 x 600

 

Air inlet vents

 

 

 

 

 

 

Control box

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

600

 

 

1 000

600

Air outlet vents

Front

Front view

Unit: mm

20 or more

Ceiling dimension and hanging bolt location

Install the unit above the ceiling correctly.

CASE 1

Position of suspension Bolt

-Apply a joint-canvas between the unit and duct to absorb unnecessary vibration.

-Apply a filter Accessory at air return hole.

 

E

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

G

<![if ! IE]>

<![endif]>D

<![if ! IE]>

<![endif]>C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

J

 

 

 

 

 

 

 

 

 

 

 

A

 

 

 

 

 

 

 

 

 

 

 

B

 

 

 

 

 

 

 

<![if ! IE]>

<![endif]>F I

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Drain hole

 

 

 

 

 

 

 

 

 

(Unit:mm)

 

Dimension

A

B

C

D

E

F

G

H

I

J

Chassis

 

 

 

 

 

 

 

 

 

 

 

M1

933.4

971.6

619.2

700

30

270

15.2

858

201.4

900

 

M3

1 283.4 1 321.6

619.2

700

30

270

15.2

1 208

201.4

1 250

Confirm the positional relationship between the unit and suspension bolts.

-Installation the ceiling opening to clean the filter or service under the product.

<![if ! IE]>

<![endif]>ENGLISH

<![if ! IE]>

<![endif]>ENGLISH

8 INSTALLATION OF INDOOR

CASE 2

-Install the unit leaning to a drainage hole side as a figure for easy water drainage.

Position of console Bolt

-A place where the unit will be leveled and that can support the weight of the unit.

-A place where the unit can withstand its vibration.

-A place where service can be easily performed.

M10 Nut

X 4

(Local

M10 SP. washer X 4

supply)

M10 washer

X 4

 

M10 washer

X 4

(Local

M10 SP. washer X 4

supply)

M10 Nut

X 4

 

Select and mark the position for fixing bolts

-Drill the hole for set anchor on the face of ceiling.

! CAUTION

Tighten the nut and bolt to prevent unit falling.

-Insert the set anchor and washer onto the suspension bolts for locking the suspension bolts on the ceiling.

-Mount the suspension bolts to the set anchor firmly.

-Secure the installation plates onto the suspension bolts (adjust level roughly) using nuts, washers and spring washers.

Old building

 

New building

 

 

 

1 Set anchor

2 Plate washer

3 Spring washer

4Nut

5Suspension bolts

Wiring Connection

Open the control box cover and connect the Remote controller wiring and Indoor power wires.

Remove the control box cover for electrical connection between the indoor and outdoor unit.

Use the cord clamper to fix the wiring.

! CAUTION

The connecting wiring connected to the indoor and outdoor unit should be complied with the following specifications (This equipment shall be provided with a wiring set complying with the national regulation).

GN/YL

NORMAL

20

mm

 

 

 

CROSS-SECTIONAL

AREA 0.75 mm2

If the supply wiring is damaged, it must be replaced by a special wiring or assembly available from the manufacturer of its service agent.

INSTALLATION OF INDOOR 9

! CAUTION

The Power cord connected to the unit should be selected according to the following specifications.

Precautions when laying power wiring

Use round pressure terminals for connections to the power terminal block.

Round pressure terminal

Power wiring

When none are available, follow the instructions below.

Do not connect wiring of different thicknesses to the power terminal block. (Slack in the power wiring may cause abnormal heat.)

When connecting wiring which is the same thickness, do as shown in the figure below.

<![if ! IE]>

<![endif]>ENGLISH

Loading...