PROSCAN SERIES
Radar Level Transmitter
Excellent Chemical Resistance
High Accuracy
Suitable for Foam / Va
por
Measurement Principle
The ProScan Series transmitter measures the liquid level
inside the tank or sump by using an all plastic (PP or
PTFE) antenna or horn that sends and receives low
energy radar pulses. The sensor is mounted to the top of
the tank and the pulsed signal is reflected off the liquid
surface, the echo (returned signal) is then picked up or
received by the transmitters antenna. The time it takes is
compared to known laws of physics (speed of light), once
this is done the distance can be determined, and very
accurately measured.
istance = (Speed of Light x Time Delay) / 2
D
The ProScan Series does not contact the process liquid
and therefore is an excellent choice for applications that
may be corrosive, coating, dirty, or crystallizing. The are
temperature compensated over the entire range (-40260°F) and can be used on to measure liquid under
pressure or vacuum.
The ProScan Series is both reliable and accurate; there is
no requirement for re-calibration, and virtually zero
maintenance as there are no moving parts.
The ProScan Series utilizes a special microprocessor
technology and mapping software that allows it to be used
where other non-contact level sensing products fail or go
lost i.e. Ultrasonics on Foam, Vapor, Condensate or
Turbulence.
FEATURES
•
Plastic Design / Chemical Resistant
•
Small Dead Band
•
PTFE A
•
Low Profile
•
Simple Programming
•
Suitable for Foam / Va
•
Fail Safe Diagnostics
•
Simple Configuration
•
IP67 Housing
•
Epoxy Coated Enclosure
•
Loop Powered / 2 Wire
ntenna (Horn)
por
SPECIFICATIONS
Working Frequency
Range
Repeatability
Resolution
Sampling
Response Rate
Accuracy
Temperature
Output Signal
Display
Power Supply
Connection
Communication
Dimensions
Enclosure Rating
Enclosure-Material
6.8 GHZ
0 - 36 m / 0 - 118 ft
±3mm / 0.11"
1mm / 0.04"
55/Sec
1.1 Sec
> 0.1% 4mm 0.16"
PTFE (-40 - 130°C) / (-40 - 266°C)
4-20mA / Hart
4-Digits LCD
24VDC
1½" NPT / 150 lb ANSI Flange
4-20mA / RS485
96x 48 x 98 mm
NEMA 4X / IP67
NORYL / Epoxy Coated Aluminum

PROSCAN SERIES
Radar Level Transmitter
STANDARD INSTALLATION
Ensure the radar antenna is not tilted
towards the tank wall.
The rod antenna (Tip) must be inside
tank. (See Diagram)
The vertical 90 placement of the sensor
- beam must be perpendicular to liquid.
No tools are required to Install
Shield
DIMENSIONS OF INSTRUMENTS
96mm
41
1 ½" NPT
H
150#
Ansi Flange
Shield
96mm
Low Torque
gasket
H
66
147
216
20
NPT 1 ½
L
ORDERING
Connection Input Output
NPT PS8000 Teflon
32
®
Flange PS8500 Teflon
®