Level Pro ProAlert 1000 Specifications

Page 1
PROALERT-1000 SERIES
Industrial Visual / Audible Sentry Alarm
All Plastic NEMA 4X Enclosure
Hinged Design Easy Access
Built in
Audible Alarm
Lockout
Capability
Test
Silence
ggle
To Switch
Mounting
Holes
FEATURES
High Intensity Red Alarm Light
90dB Audible Alarm with External Test / Silence / Normal Position
Rugged NEMA 4X Industrial Enclosure
Latching Lockable Cover
External Wa
Listed Enclosure / (CSA)
UL
High Impact Plastic Polycarbonate Shell
Excellent Chemical Resistance
Includes 6' Power Cord + Wa
ll Mounting Feet
tertight Cord
Connector
TYPICAL APPLICATIONS
High / Low Level Indication
for Tanks / Sumps Bag / Filter Change Out
Leak Detection
Flow / No Flow Sensors / Pump Protection
Upset Condition Notification
Cable Grip (STD)
+
6 ft Cord Included
SPECIFICATIONS
Dimensions / 7" X 5" X 4.5"
Enclosure / NEMA 4X
ight / 2.1 lbs.
We
120v / 60Hz / 1 A
Input Power / 100 - 240VA
mp
C
Page 2
PROALERT-1000 SERIES
Industrial Visual / Audible Sentry Alarm
ALARM INSTALLATION
Decide Mounting location.
Install the unit using the built-in mounting feet.
Hook the 120VAC plug into a 120VAC receptacle on a separate branch circuit from the one used for the sensor/flow switch to ensure proper notification.
Connect Switch/Sensor following Manufacturers Instructions.
Switch the toggle switch to the 'Normal' position. Manually test the alarm by powering the sensor/flow switch until you hear the alarm notification and you see the alarm light turn on.
Periodically test unit by moving the toggle switch to the 'Test' position recommended prior to filling or draining.
The audible alarm can be silenced by moving the toggle switch to the 'Silence' position. Ensure the toggle switch is typically left in the "Normal" position for proper alarm notification.
ELECTRICAL SCHEMATIC
115V-1Ø-60 Hertz Power Supply
WHITE
ALARM LIGHT
BLUE RED
F1 F2
HIGH LEVEL
FLOAT
TEST
NORMAL
SILENCE
WARNING
WARNING
Failure to follow these precautions could result in serious injury or death. Replace product immediately if switch cable becomes damaged or severed. Keep these instructions with warranty after installation. This product must be installed in accordance with CSA, ANSI/NFPA 70 so as to prevent moisture from entering or accumulating within boxes, conduit bodies, fittings, float housing, or cable.
ELECTRICAL SHOCK HAZARD
Disconnect power before installing or servicing this product. A qualified service person must install and service this product according to applicable electrical and plumbing codes.
EXPLOSION OR FIRE HAZARD
Do not use this product with flammable liquids. Do not install in hazardous locations as defined by CSA, ANSI/NFPA 70.
AUDIBLE ALARM
R1
NCC
YELLOW
R1
AUDIBLE
Wiring Diagram for ProAlert
BLACK
BLACK
YELLOW
ALARM
LIGHT
BLK
TST NOR SIL
REST-NORMAL-SILENCE
SWITCH
(SPRING RETURN FRO
TEST POSITION)
RED
BLUD
YELLOW
N
FIELD WIRING CONNECTIONS
BLUE
L N
(115 VAC
POWER)
WHITE
WHITE
RED
BLUE
ALARM
MODELS
PA-1000- ProAlert
120V - Dry Contact Input
-1000-PR - PNP / NPN Pulse
PA
Input - 5AMP Relay Timer Signal Output
-1C
-120VAC
COM
RED
NC
NO