PROALERT-1000 SERIES
Industrial Visual / Audible Sentry Alarm
All Plastic
NEMA 4X
Enclosure
Hinged Design
Easy Access
Built in
Audible Alarm
Lockout
Capability
Test
Silence
ggle
To
Switch
Mounting
Holes
FEATURES
•
High Intensity Red Alarm Light
•
90dB Audible Alarm with External
Test / Silence / Normal Position
•
Rugged NEMA 4X Industrial
Enclosure
•
Latching Lockable Cover
•
Lockable
•
External Wa
•
Listed Enclosure / (CSA)
UL
•
High Impact Plastic Polycarbonate Shell
•
Excellent Chemical Resistance
•
Includes 6' Power Cord + Wa
ll Mounting Feet
tertight Cord
Connector
TYPICAL APPLICATIONS
High / Low Level Indication
•
for Tanks / Sumps
Bag / Filter Change Out
•
Leak Detection
•
Flow / No Flow Sensors / Pump Protection
•
Upset Condition Notification
•
Cable Grip (STD)
+
6 ft Cord Included
SPECIFICATIONS
•
Dimensions / 7" X 5" X 4.5"
•
Enclosure / NEMA 4X
•
ight / 2.1 lbs.
We
•
120v / 60Hz / 1 A
•
Input Power / 100 - 240VA
mp
C

PROALERT-1000 SERIES
Industrial Visual / Audible Sentry Alarm
ALARM INSTALLATION
•
Decide Mounting location.
•
Install the unit using the built-in mounting feet.
•
Hook the 120VAC plug into a 120VAC
receptacle on a separate branch circuit from the
one used for the sensor/flow switch to ensure
proper notification.
•
Connect Switch/Sensor following Manufacturers
Instructions.
•
Switch the toggle switch to the 'Normal'
position. Manually test the alarm by powering
the sensor/flow switch until you hear the alarm
notification and you see the alarm light turn on.
•
Periodically test unit by moving the toggle switch
to the 'Test' position recommended prior to
filling or draining.
•
The audible alarm can be silenced by moving
the toggle switch to the 'Silence' position.
Ensure the toggle switch is typically left in the
"Normal" position for proper alarm notification.
ELECTRICAL SCHEMATIC
115V-1Ø-60 Hertz Power Supply
WHITE
ALARM LIGHT
BLUE RED
F1 F2
HIGH LEVEL
FLOAT
TEST
NORMAL
SILENCE
WARNING
WARNING
Failure to follow these precautions could result in serious injury or death.
Replace product immediately if switch cable becomes damaged or severed.
Keep these instructions with warranty after installation. This product must be
installed in accordance with CSA, ANSI/NFPA 70 so as to prevent moisture from
entering or accumulating within boxes, conduit bodies, fittings, float housing, or
cable.
ELECTRICAL SHOCK HAZARD
Disconnect power before installing or servicing this
product. A qualified service person must install and
service this product according to applicable electrical
and plumbing codes.
EXPLOSION OR FIRE HAZARD
Do not use this product with flammable liquids. Do not
install in hazardous locations as defined by CSA,
ANSI/NFPA 70.
AUDIBLE ALARM
R1
NCC
YELLOW
R1
AUDIBLE
Wiring Diagram for ProAlert
BLACK
BLACK
YELLOW
ALARM
LIGHT
BLK
TST NOR SIL
REST-NORMAL-SILENCE
SWITCH
(SPRING RETURN FRO
TEST POSITION)
RED
BLUD
YELLOW
N
FIELD WIRING CONNECTIONS
BLUE
L N
(115 VAC
POWER)
WHITE
WHITE
RED
BLUE
ALARM
MODELS
PA-1000- ProAlert
•
120V - Dry Contact Input
-1000-PR - PNP / NPN Pulse
PA
•
Input - 5AMP Relay Timer Signal Output
-1C
-120VAC
COM
RED
NC
NO