Level Pro ITC 900 Specifications

Page 1
www.levelprosales.com
ITC 900
LevelproSubmersiblePVC Level Pressure Sensor
Ceramic Sensor accuracy according to IEC 60770:
standard: 0.35 % FSO option: 0.25 % FSO
Nominal pressure
The separable plastic submersible probe LMK 858 is designed for level measurement in most aggressive media. Usage in more viscous media as for example sludge is possible because of the semi-flush diaphragm.
In order to facilitate stock-keeping andmain­tenance the transmitter head is plugged to the cable assembly with a connector and can be changed easily.
from 0 ... 16 in/H2O up to 0 ... 460 ft/H2O
Output signals
2-wire: 4 ... 20 mA
Special characteristics
diameter 45 mm cable and probe separable chemical resistance housing PVC
Optional versions
Preferred areas of use are
Sewage
waste water treatment water recycling dumpsite
cable protection via PVC pipe diaphragm 99.9 % AI2O3 different kinds of cable different kinds of seal materials
Aggressive media
level measurement in most of acids and lyes
Page 2
ITC 900
Plastic Probe Technical Data
www.levelprosales.com
Input pressure range
Nominal pressure
[bar]
0.04
0.06
0.1
0.16
0.25
0.4
0.6 1 1.6
2.5 4 6
10
Level
[mH2O]
0.4
0.6 1 1.6
2.5 4 6
10
16
25
40
60
100
Overpressure
[bar]
2 2 4 4 6 6 8 8 15
25
25
35
35
Output signal / Supply
Standard
2-wire: 4 ... 20 mA / VS = 9 ... 32 VDC
option 3-wire: 0 ... 10 V / VS = 12.5 ... 32 VDC
Performance
Accuracy
standard: option:
IEC 60770 1
≤ ± 0.35 % FSO ≤ ± 0.25 % FSO
Permissible load
Rmax = [(VS – VS min) / 0.02 A] Ω
Influence effects
supply: 0.05 % FSO / 10 V load: 0.05 % FSO / kΩ
Long term stability
≤ ± 0.1 % FSO / year
Turn-on time
700 msec
Mean response
< 200 msec
measuring rate 5/sec
Max. response time
380 msec
1
accuracy according to IEC 60770 – limit point adjustment (non-linearity, hysteresis, repeatability)
Thermal effects (Offset and Span)
Thermal error
≤ ± 0.1 % FSO / 10 K in compensated range 0 ... 50 °C
Permissible temperatures
Permissible temperatures
medium: -10 ... 50 °C electronic / environment: -10 ... 50 °C storage: -10 ... 50 °C
Electrical protection
2
Short-circuit protection
permanent
Reverse polarity protection
no damage, but also no function
Electromagnetic compatibility
Emission and immunity according to EN 61326
2
additional external overvoltage protection unit in terminal box KL 1 or KL 2 with atmospheric pressure reference available on request
Electrical connection
Cable with sheath material 3
PVC (-5 … 50 °C) grey PUR (-10… 50 °C) black FEP (-10 … 50 °C) black
Cable protection
standard: without cable protection optional: prepared for mounting of a PVC pipe with diameter 25 mm
3
cable with integrated air tube for atmospheric pressure reference
Materials (media wetted)
Housing
PVC grey
Seals
FKM / EPDM / others on request
Diaphragm
standard: ceramics Al2O3 96 % option: ceramics Al2O3 99.9 %
Miscellaneous
Connecting cables (by factory)
cable capacitance: signal line/shield also signal line/signal line: 160 pF/m cable inductance: signal line/shield also signal line/signal line: 1 μH/m
Current consumption
Max. 25 mA
Weight
approx.. 400 g (without cable)
Ingress protection
IP 68
CE – conformity
EMC Directive: 2004/108/EC
Wiring diagram
Page 3
ITC 900
Plastic Probe Technical Data
www.levelprosales.com
Pin configuration
This data sheet contains product specification, properties are not guaranteed.
Subject to change without notice.
Electrical connection
Binder series 723 4 (5-pin)
cable colours (DIN 47100)
2 – wire
3 - wire
Supply +
Supply –
Signal + (only for 3-wire)
3 1
-
3 4 1
wh (white)
bn (brown)
gn (green)
Shield
5
5
gn/ye
(green / yellow)
4
in separated version
Dimensions (in mm)
Accessories
Terminal clamp
Technical Data
Suitable for
all probes with cable 5.5 ... 10.5 mm
Material
standard: steel, zinc plated optionally: stainless steel 1.4301 (304)
Weight
approx.. 160 g
Ordering type
Ordering code
Terminal clamp, steel, zinc plated
Z100528
Terminal clamp, stainless steel 1.4301 (304)
Z100527
Page 4
ITC 900
Plastic Probe Technical Data
www.levelprosales.com
OrderingcodeITC 900
This price list contains product specification; properties are not guaranteed. Detailed information about options are defined
in the datasheet. Subject to change without notice.
ITC 900
- - - - - - - - -
Pressure
in bar
4 1 5
in mH2O
4 1 6
Input [mH2O] [bar]
0.40
0.04
0 4 0 0
0.60
0.06
0 6 0 0
1.0
0.10
1 0 0 0
1.6
0.16
1 6 0 0
2.5
0.25
2 5 0 0
4.0
0.40
4 0 0 0
6.0
0.60
6 0 0 0
10
1.0
1 0 0 1
16
1.6
1 6 0 1
25
2.5
2 5 0 1
40
4.0
4 0 0 1
60
6.0
6 0 0 1
100
10
1 0 0 2
customer
9 9 9 9
consult
Housing
PVC
A
customer
9
consult
Diaphragm
Ceramics Al2O3 96%
2
Ceramics Al2O3 99.9%
C
customer
9
consult
Output
4 … 20 mA / 2-wire
1
0 … 10 V / 3-wire
3
customer
9
consult
Seals
FKM
1
EPDM
3
customer
9
consult
Electrical connection
PVC-cable 1
1
PUR-cable 1
2
FEP-cable 1
3
customer
9
consult
Accuracy
standard 0.35 %
0.35 %
3 option 0.25 %
2
customer
9
consult
Cable length
in m
9 9 9 Special version
standard
0 0 0 prepared for mounting with PVC pipe2
1 0 6
customer
9 9 9
consult
1
cable with integrated air tube for atmospheric pressure reference
2
PVC pipe is not part of the supply
01.06.2013
Loading...