Level Pro 700 Specifications

www.levelprosales.com
Always on the Level
700 series
PVDF/PP Heavy Duty Plastic Level Pressure Transmitter For Corrosive Media
Excellent For Tank Level Measurement
Pressure Measurement
The 700 Series Plastic Pressure Transmitter isdesigned for continuous level measurement in thetoughest industrial environments.
from 5.4 ft/H2O up to 54 ft/H2O
2.33 PSI to 23 PSI
Output Signal
2 wire: 4-20 mA
Applications
Features
Waste water
• Leachate
• Sumps or Pits
• Strong Cable Design with
Maintenance Free Breather Tube
• Automatic Temperature Compensation for Accurate Measurement
Heavy Duty Rugged Design No Moving Parts Designed for Tank Level Measurement of
Viscous
and Aggressive Liquids* High Accuracy Ceramic Sensing Diaphragm Housing Material PVDF or PP Flush Sensor - Non Clogging Great for Foam-Vapour Applications High Accuracy Compact Design
FEP Teflon Coated cable (3m, 5m, 10m,
15m)**
Aggressive liquids
• Acids
• Caustics
• Sodium Hypochlorite
• Peroxides
* Check Chemical Resistance
700 Series
Technical Data
www.levelprosales.com
Pressure Range
Pressure PSI
2.32 3.6 5.8 8.7 14.5 23.2
Liquid Level ft/H2O
5.4 8.36 13.4 20.0 33.5 53.6
Output Signal/Supply
Standard
2-wire: 4-20mA Vs 8–32VDC
Performance
Accuracy
Standard <+ 0.35% full scale
Long Term Stability
<± 0.1% FS/year
Turn-on Time
<700 msec
Mean Response Time
<200 msec
Max. Response Time
<380 msec |measuring rate: 5/sec
Thermal Effects (Offset and Span)
Thermal Error
<± 0.1% FS/ 10 K
within compensated range 0 - 70 °C 32 °F - 160 °F
Permissible Temperatures
Permissible Temperatures
Normal -25 – 100°C
Mean Response Time
Electronic/Environment -25 – 100°C
Max. Response Time
Normal -25... 100°C
Electrical Protection
Short-circuit Protection
Yes – Permanent
Reverse Polarity Protection
Yes – No damage
Electromagnetic Compatibility
Emission and Immunity
Electrical Connection
Cable with sheath material
-25 °F -180°F
Materials (wetted)
Housing
PVDF/PP
Seals
FKM/EPDM/FFKM (KALREZ®)
Diaphragm
Ceramic AI203
Miscellaneous
Current Consumption
Max. 21 mA
Weight
320g (w/o cable)
Ingress Protection
IP 68
Wiring Diagram
Pin Configuration
Electrical Connection
Cable Colours
Supply+ wh (white)
Supply- bn (brown)
Shield
(green/yellow)
PP/PVDF LEVEL TRANSMITTER
Loading...
+ 1 hidden pages