100 SERIES
Continuous Submersible Level Transmitter
Continuous Level Sensor
Works on Foam / Vapor / Turbulence
Excellent Chemical Resistance
All Plastic Design
PTFE Teflon® Shielded Cable
PVC PP PVDF
SERIES : 100
BODY : PVC / PP / PVDF / 316 SST
LP 100
316SS
RoHS
Compliant
TVL Display
LP 100 Junction Box
PVC Version
The 100 Series Transmitter is designed for
Continuous Level Measurement of Aggressive
Liquid Media
Pressure Measurement
Tanks / Sumps up to 100 ft Range
Output Signal
2 wire / 4-20mA (Std) / Hart / RS485
Features
Suitable for Corrosive Chemicals
Built in Weight / Eliminates Floating
Excellent Long Te
High A
Flush Sensor / Non Clogging Design
Heavy Duty PTFE Cable / 5m / 10m / 15m
Length - Other Lengths Available
Excellent for Foam / Vapor / Condensate
Ceramic Sensing Diaphragm
ccuracy
rm Stability
Applications
Sewage
Foam / Vapor / Turbulence / Condensate
•
Waste Water Treatment
•
Leachate Collection
•
ste Sumps or Pits
Wa
•
Chemical Dosing
•
Inventory Management
•
Aggressive media
Acids + Bases
•
Bulk Chemicals
•
Chemical Day Ta
•
Plating Ta
•
PH Control Ta
•
Storage Ta
•
nks
nks
nks
nk Monitoring
Heavy Duty Rugged Design
No Moving Parts
Automatic Te
mperature Compensation
Excellent for Tanks / Sumps / Large (100') / Small (12")
The Solution to Tough Applications where
Ultrasonic Sensors Simply DO NOT WORK!
No Lost Signals

100 SERIES
Continuous Submersible Level Transmitter
Input Pressure Range
Level ft/H2O
Overpressure psi
Burst Pressure > psi
14.0 20.0 33.5 54
210 290 290 380
290 580 580 720
* Consult Factory for Levels > 54 Ft
Output Signal/Supply
Standard
2-wire / 4-20mA (Loop Powered) Hart / RS 485 / Voltage
Performance
Accuracy
Permissible load
Influence effects
Long term stability
Response time
1
accuracy according to IEC 60770 - limit point adjustment (non-linearity / hysteresis / repeatability)
<± 0.5% Full Scale or Better
Rmax = [(Vs-Vsmin)/0.02 A]
Supply : 0.05% Full Scale/10V
Load : 0.05% Full Scale/K
<± 0.1% Full Scale over One Year
<10 msec or better
Thermal Effects (Offset and Span)
Thermal Error
<± 0.2% FSO/K
in compensated range -25 - 70°C / -13 - 158° F
Permissible Temperatures
Permissible Temperatures
Medium PVC 32°F - 140°F / PP -4° - 178°F / PVDF -30 - 178 °F / 316 SS -30 - 178°F
Storage -10°C - 60°C
Electrical Protection
Short-circuit Protection
Reverse Polarity Protection
Electromagnetic Compatibility
Short-circuit Protection
Permanent
No Damage to Sensor
Emission Immunity according to EN 61326
Permanent
Electrical Connection
Cable with sheath material
3 Wire Cable with integrated air tube for atmospheric pressure reference
PTFE (Teflon®) / (0 - 200°F)
Materials (wetted)
Housing
Seals
Diaphragm
PVC / PP / PVDF / 316 SS
FFKM - Kalrez®
Ceramic AI2 03

100 SERIES
Continuous Submersible Level Transmitter
Miscellaneous
Current Consumption
Weight
Ingress Protection
CE-Conformity
Max. 25mA
approx. 200g (without cable)
IP 68
EMC Directive: 2004/108/EC
Wiring Diagram
Supply +
P
Supply -
I
2-wire-system (current) 4-20mA
Ordering Code 100 Series
V
+
s
(Red)
(Black)
Electrical Connection
Cable Colours
Supply + wh (Red)
Supply - bn (Black)
Shield (yellow)
1 1 3 3
Pressure
ft/H20 1 9 1
Input ft/H20
14.0
20.0
34.0
54.0
Housing
PVC
PP
PVDF
16 SS
3
Cable Length
M-Meters,
Note: Consult Factory for Different Level Ranges Note: 0 - 34' Range comes with 15M Cable
1
4
0
1
1
2
0
1
1
0
0
1
4
0
0
1
A
B
E
1 1 3 3SS
* cable comes with integrated air tube for atmospheric pressure reference
DC Power Only
RoHS
Compliant