LevelOne IGP-0101 User Manual

1
IGP-0101
Industrial Gigabit POE Injector, 802.3at PoE+, 36W
User Manual
2
FCC MARKING
This Equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received; including interference that may cause undesired operation.
CE MARKING
This equipment complies with the requirements relating to electromagnetic compatibility, EN 55022 class A for ITE, the essential protection requirement of Council Directive 2004/108/EC on the approximation of the laws of the Member States relating to electromagnetic compatibility.
Company has an on-going policy of upgrading its products and it may be possible that information in this document is not up-to-date. Please check with your local distributors for the latest information. No part of this document can be copied or reproduced in any form without written consent from the company.
Trademarks: All trade names and trademarks are the properties of their respective companies.
Copyright © 2013, All Rights Reserved.
3
NOTE:
Always make sure the total length of the TX cable DOES NOT exceed 100meter. Total length is defined as length A + length B
PD
Remote Switch A
B
Maximum total cable length is 100meter.
During 100Mbps transmission, the maximum total cable length is 100 meter.
During 1000Mbps speed transmission, recommend maximum cable length less than 90 meter is more desired.
POE signal attenuates every meter, the built-in transformer allows the attenuation to reach 100 meter long to follow IEEE802.3af / at standard. the higher quality of PD you connected to, the more reliable the network will be. When connect to a poor quality PD, it can not generate strong signal to send to remote switch. Always make sure you have a high quality PD to perform a desired network.
Length A + Length B < 100 meter