LevelOne FVT-5001, FVT-5301, GVT-5000 User Manual

Page 1
FVT-5001 / FVT-5301 / GVT-5000
Copper to Fiber
Media Converter Module
User Manual
Part No.
No.
Description
532502 FVT-5001
10/100Base-TX to 100Base-FX SC, Multi-mode 2km (TS-1000)
532530 FVT-5301
10/100Base-TX to 100Base-FX SC, Single-mode 30km (TS-1000)
532500 GVT-5000
1000BaseT to SFP mini-GBIC Converter Module
Ver. 1.02 - 0701
Page 2
FCC Warning
This Equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help.
CE Mark Warning
This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.
Page 3
Table of Contents
1. INTRODUCTION................................................1
1.1. FAST ETHERNET EXPENSION MODULE.............1
1.2. GIGABIT EXPENSION MODULE .........................1
1.3. PACKAGE CONTENTS......................................2
2. HARDWARE DESCRIPTION............................2
2.1. FRONT PANEL.................................................2
2.2. FAST ETHERNET LED INDICATORS ..................3
2.3. GIGABIT LED INDICATORS...............................4
3. INSTALLATION.................................................5
3.1. CHASSIS ........................................................5
3.2. FIBER.............................................................6
4. SPECIFICATION................................................7
4.1. OPTICAL FIBER...............................................7
4.2. OPTIONAL SFP MODULES...............................7
4.3. TECHNICAL SPECIFICATION .............................8
Page 4
1
1. Introduction
These converter modules are for FVT-5000 16 slot Converter Chassis with TS-1000 supported. By this converter module, user can get higher bandwidth from your network infrastructure and extend network available link distance by fiber cable
1.1. Fast Ethernet Expansion Module
Comply with IEEE 802.3, 802.3u standards  Convert between UTP cabling and Fiber-optic cabling  One RJ-45 connector, Auto-MDI/MDIX for UTP port  Support 10/100 Mbps Auto-negotiation for UTP port  Support TS-1000, Loop Back Test  Built in Link Lose Forwarding Technology  Remote Monitor/Control for Terminal side  Hot swappable
1.2. Gigabit Expansion Module
Comply with IEEE 802.3, 802.3u, 802.3ab, 802.3z standards  Convert between UTP cabling and Fiber-optic cabling  One SFP slot for mini-GBIC module  One RJ-45 connector, Auto-MDI/MDIX for UTP port  Support 10/100/1000 Mbps Auto-negotiation for UTP port  Built in Link Lose Forwarding Technology  Remote Monitor/Control for Terminal side  Hot swappable
Note:
Gigabit Module does not support TS-1000
Page 5
2
1.3. Package Contents
- Media Converter Module
- User manual
If any item is damaged or missing, please contact your local dealer for service.
2. Hardware Description
2.1. Front Panel
FVT-5001
FVT-5301
GVT-5000
Page 6
3
2.2. Fast Ethernet LED Indicators
LED Status Meaning PWR Green Power on
Green Link on 100Mbps Speed
SPD (UTP)
OFF Link on 10Mbps Speed Green The unit is linking with it’s link partner. Blinks The unit is transmitting or receiving packets
LK/ACT (UTP)
Off No device attached Green The unit is linking with it’s link partner. Blinks The unit is transmitting or receiving packets
LK/ACT (Fiber)
Off No device attached Orange The UTP port is operating in full-duplex mode. Blinks Collision of Packets occurs in the port.
FDX/COL (UTP)
Off Half-duplex mode or no device attached Orange The fiber port is operating in full-duplex mode. Blinks Collision of Packets occurs in the port.
FDX/COL (Fiber)
Off Half-duplex mode or no device attached
Link Lost Forwarding: When LLF is enable, allow UTP link failures to be reported to the fiber side and also allow Fiber link failure to be reported to the UTP side. Therefore, A link loss forward feature is provided in both UTP and Fiber side.
Page 7
4
2.3. Gigabit LED Indicators
LED Status Meaning
PWR Green Power on
Green Link on 1000Mbps Speed Orange Link on 100Mbps Speed
SPD (UTP)
OFF Link on 10Mbps Speed Green The unit is linking with it’s link partner. Blinks The unit is transmitting or receiving packets
LK/ACT (UTP)
Off No device attached Green The unit is linking with it’s link partner. Blinks The unit is transmitting or receiving packets
LK/ACT (Fiber)
Off No device attached Orange The UTP port is operating in full-duplex mode. Blinks Collision of Packets occurs in the port.
FDX/COL (UTP)
Off Half-duplex mode or no device attached Orange The fiber port is operating in full-duplex mode. Blinks Collision of Packets occurs in the port.
FDX/COL (Fiber)
Off Half-duplex mode or no device attached
Page 8
5
3. Installation
3.1. Chassis
This installation is only for mounting in converter chassis converter module. You can follow the steps below to install modular converters. Remove the module slot cover from the converter chassis. Install the modular converter by inserting it into the guides and sliding it in, and then, press it firmly until the power plug in the chassis plugs into the modular converter receptacle property. Push the thumbscrews in and turn clockwise to tighten. Do not over tighten the thumbscrews.
Front Panel with all modules installed
Page 9
6
3.2. Fiber
For the Fast Ethernet Fiber Port: We provide SC connectors (multi/single mode). Please follow the below figure to connect it. Wrong connection will cause the port cannot work properly.
This is a Class 1 Laser/LED product Do not stare into the Laser/LED beam
ATTENTION
Page 10
7
4. Specification
4.1. Optical Fiber
Model No.
Wavelength
(nm)
Avg. Launch
Power (dB)
Avg.
Sensitivity (dB)
FVT-5001 SC, Multi-mode
1310 (nm) -18 (dB) -30 (dB)
FVT-5301 SC, Single-mode
1310 (nm) -6 (dB) -34 (dB)
Model No.
Avg. Power
Loss Budget
(dBm)
Max. FDX Fiber
Distance (Km)
Fiber Size (um)
FVT-5001 SC, Multi-mode
12 (dBm) 2 (Km)
62.5/125 50/125
FVT-5301 SC, Single-mode
28 (dBm) 30(Km)
10/125
8/125
4.2. Optional SFP Modules
GVT-5000 supports 3.3V mini-GBIC module
Part No. Model No. Description
570622 GVT-0300
Mini-GBIC SFP transceiver Multi-Mode, 550m
551071 GVT-0301
Mini-GBIC SFP transceiver Single-Mode, 10km
551072 GVT-0302
Mini-GBIC SFP transceiver Single-Mode, 70km
Page 11
8
4.3. Technical Specification
Fast Ethernet Module
Standard
IEEE802.3 10Base-T IEEE802.3u 100Base-TX/100Base-FX IEEE802.3x Flow Control and Back pressure TS-1000 Supported
Connector
Fiber: Duplex SC RJ-45 Socket: 10/100Mbps Twisted Pair cable Auto MDI/MDI-X and Auto-Nego tiation
Switch architecture
Store and Forward
Fiber parameters
Fiber Core: Multi-Mode (62.5/125um, 50/125um) Single-Mode (8/125um, 10/125um) Wavelength: 1310nm(Multi-mode) 1310nm(Single-mode) Fiber Distance: Multi-Mode Fiber 2KM Single-Mode Fiber 30KM
Transparent packet
68 to 1522Bytes
Link Lost Forward
UTPÎFiber: If UTP port link down, then converter will forced fiber to link down. Fiber Î UTP: If Fiber port link down, the media converter will force UTP port to link down.
LED
Power, UTP (SPD, LK/ACT, FDX/COL) Fiber (LK/ACT, FDX/COL)
Operation Temp.
0 to 45 (32 to 113℉)
Storage Temp.
-10 to 70
Operation Humidity
10% to 90% (Non-condensing)
EMI & safety CE, FCC Class A
Page 12
9
Gigabit Ethernet Module
Standard
IEEE802.3ab 1000Base-T IEEE802.3z 1000Base-SX/LX IEEE802.3x Flow Control and Back pressure
Connector
Fiber: SFP Slot, 3.3V RJ-45 Socket: 10/100/1000Mbps Twisted Pair cable Auto MDI/MDI-X and Auto-Nego tiation
Switch architecture
Store and Forward
Fiber parameters
Fiber Core: Multi-Mode (62.5/125um, 50/125um) Single-Mode (8/125um, 10/125um) Wavelength: 850nm(Multi-mode) 1310nm(Single-mode) Fiber Distance: Depend on mini-GBIC transceiver type
Transparent packet
68 to 1522Bytes
LED
Power, UTP (SPD, LK/ACT, FDX/COL) Fiber (LK/ACT, FDX/COL)
Operation Temp.
0 to 45 (32 to 113℉)
Storage Temp.
-10 to 70
Operation Humidity
10% to 90% (Non-condensing)
EMI & safety CE, FCC Class A
Loading...