LevelOne FVT-5000 User Manual

Page 1
FVT-5000
16-Slot Managed Converter Chassis
w/ Redundant Power Supply
User Manual
Ver 1.00 - 0701
Page 2
1. INTRODUCTION..................................................................................................................1
1.1. FEATURES ..................................................................................................................... 1
1.2. SOFTWARE FEATURE...................................................................................................... 2
1.3. MANAGEMENT METHODS................................................................................................3
1.3.1. Console and Telnet..................................................................................................3
1.3.2. Web-based .............................................................................................................. 3
1.3.3. SNMP Network........................................................................................................3
1.4. PACKAGE CONTENTS......................................................................................................4
2. HARDWARE DESCRIPTION............................................................................................... 5
2.1. FRONT PANEL................................................................................................................5
2.2. REAR PANEL..................................................................................................................5
2.3. LED INDICATORS ........................................................................................................... 6
3. CONNECTING TO THE NETWORK....................................................................................7
3.1. PRE-INSTALLATION REQUIREMENTS ................................................................................7
3.2. MOUNTING THE DEVICE .................................................................................................. 8
3.2.1. Desktop Installation................................................................................................. 8
3.2.2. Rack Mounting......................................................................................................... 9
3.3. POWER ON ..................................................................................................................10
3.4. DIAGNOSTIC TEST ........................................................................................................ 10
3.4.1. Connecting the Device via Local console..............................................................10
3.4.2. Connecting the Device via Telnet..........................................................................12
3.4.3. Connecting the Device via Web Browser..............................................................13
4. CONSOLE MANAGEMENT............................................................................................... 14
4.1. DEVICE SETTING .......................................................................................................... 14
4.2. MODULES SETTINGS.....................................................................................................16
4.3. REDUNDANT POWER STATUS........................................................................................ 18
4.4. EVENTS LOG................................................................................................................18
4.5. SNMP TRAP................................................................................................................19
4.6. SECURE IP FOR TELNET, HTTP AND SNMP.................................................................. 19
4.7. PORT COUNTERS .........................................................................................................20
4.8. FAN STATUS ................................................................................................................ 20
4.9. SAVE CURRENT SETTINGS............................................................................................20
4.10. FACTORY DEFAULT SETTINGS & REBOOT SYSTEM.........................................................21
4.11. REBOOT SYSTEM .........................................................................................................21
4.12. TFTP CONFIGURATION................................................................................................. 21
5. WEB-BASED MANAGEMENT.......................................................................................... 22
5.1. HOME.......................................................................................................................... 23
5.2. MODULES SETTINGS..................................................................................................... 25
5.2.1. Module................................................................................................................... 25
5.2.2. TS-1000 setting: .................................................................................................... 26
5.2.3. RJ-45 Port..............................................................................................................30
5.2.4. Fiber Port...............................................................................................................30
5.3. PORT COUNTER ...........................................................................................................31
5.4. IP CONFIG ................................................................................................................... 32
5.5. SNMP.........................................................................................................................33
5.6. EVENT LOG..................................................................................................................34
5.7. MISC SETTINGS............................................................................................................ 35
5.8. SAVE AND REBOOT.......................................................................................................38
5.9. UPGRADE ....................................................................................................................39
5.10. HELP ...........................................................................................................................39
6. SNMP MANAGEMENT...................................................................................................... 40
7. SPECIFICATION................................................................................................................ 41
8. OPTIONAL MODULE.........................................................................................................42
8.1. MODULE (TS-1000) FOR FVT-5000 ONLY....................................................................42
8.2. CONVERTER (TS-1000) ............................................................................................... 42
Page 3
1
1. Introduction
The FVT-5000 16 Slots Managed Converter Chassis is a combination of 16-slot host cabinet and optional several of media converter bracket modules. A maximum 16-bracket module can be installed in the cabinet with two redundant power supplies. The Power supply supports AC input type with load sharing redundant feature. The converter supports TS-1000 standard that provides loop back test to ensure the converter failure and remote configuration allows remote set up the module of the converter or the converter.
With build-in Web-based Management, Managing and Configuring the 16 Slots Managed Converter Chassis becomes easier. From cabinet management to each bracket module, user can visually configure and manage your network via Web Browser. The 16 Slots Managed Converter Chassis can also be managed via Telnet, Console, or third-party SNMP Management.
1.1. Features
16 slots converter chassis  Redundant AC power supply  HTTP, Telnet security  IP address security for management station  Web and TFTP firmware upgrade  Link Lost Forwarding (LLF)  Back-door password supported  Module identification  Fiber Module hot-swappable  CPU module hot-swappable  SNMP, Web, Telnet, console management  Optional different converter modules
10/100TX to 100FX module 1000T to SFP fiber module
Support TS-1000 on 10/100TX to 100FX module  Event log and SNMP Trap supported  SNMP MIB II and private MIB supported  Support Simple Network Time Protocol (SNTP)  Power and Fan Detect  Loop Back Test  EIA RS-310C 19 “ standard
Page 4
2
1.2. Software Feature
Management
Telnet Web
Console (RS-232)
Web/Telnet
Can be enabled or disabled
MIBS
RFC 1213 MIB II Private MIB
SNMP Trap
Link down Link up
Power module status change Authorization Fail Module plug in and plug out Chassis configuration change Module configuration change
Software Upgrade
Firmware upgrade by Web interface and TFTP
Link Loose Forward
Each module support LLF feature. It can be set by Web or CLI menu LLF Mode TX Fiber: UTP port link down,
the fiber port will be forced down LLF Mode Fiber UTP : Fiber port link down,
the UTP port will be forced down
Packet counter
UTP port: IN-good / In-bad packet counter out-good /out-bad packet counter
collision counter Fiber port: IN-good / In-bad packet counter out-good /out-bad packet counter
SNMP Trap Node
Up to 4 Trap node
IP security
IP security for telnet HTTP and SNMP access
Up to 4 IP nodes when security is enabled
Module Note
Per module can added notice for allocate information and characters which is up to 32
Back-door password
Supports on CLI mode only
TS-1000
Loop back test, remote configuration
SNTP
RFC2030 Simple Network Time Protocol
Events log
Up to 4095 event records. It can be reviewed by CLI and Web browser mode
Page 5
3
1.3. Management Methods
The FVT-5000 Managed Converter Chassis supports following management methods:
1.3.1. Console and Telnet
Console Management is done through the RS-232 Console Port that requires a direct connection between PC and the Device. The Telnet management is through the network. Once the Device is on the network, you can use Telnet program to Log in and modify the configuration.
1.3.2. Web-based
The 16 Slots Managed Converter Chassis provides an embedded HTML web program in flash memory. It offers advanced management features and allow users to manage the 16 Slots Managed Converter Chassis from anywhere on the network through any HTTP browser such as Microsoft Internet Explorer. For more information, see Section 5 Web-Based Management.
1.3.3. SNMP Network
SNMP (Simple Network Management Protocol) provides a way to monitor and control network device, such as configurations, statistic collection, performance, and security.
Data is collected by SNMP agents, which are hardware & software processes reporting activity in each network device. The agent reports information contained in a MIB format (Management Information Base), which is a data structure that defines what is obtainable from the device and what can be controlled.
Page 6
4
1.4. Package Contents
Unpack the carton of the 16 Slots Managed Converter Chassis and verify them against the checklist below:
- FVT-5000
- Power Cord
- Console cable
- Rack-mount Kit
- Four Rubber Pads
- User Manual
FVT-5000 Power Cord Console cable
Rack-mount Kit Rubber Pads CD User Manual
Compare the contents of your 16 Slots Managed Converter Chassis package with the standard checklist above. If any item is missing or damaged, please contact the local dealer for service.
Note:
Modules are not included. Please refer to Chapter.8 for more information
Page 7
5
2. Hardware Description
The 16 Slots Managed Converter Chassis is a modular unit that contains 16 slots and 2 power slots. All optional models come with the built-in CPU, and the RS-232 port is used for Out-of-Band Management and one Ethernet RJ-45 connector is for In-band management that both in front panel. This section mainly describes the hardware of the 16 Slots Managed Converter Chassis and gives a physical and functional overview on certain module converter.
The physical dimensions of the 16 Slots Managed Converter Chassis is 448mm x 279mm x 89mm (Lx W x H)
2.1. Front Panel
The front panel of 16 Slots Managed Converter Chassis with the cabinet and modules is shown as figure below:
Front Panel (within all modules)
2.2. Rear Panel
The 3-pronged power plug is located at the Rear Panel of the 16 Slots Managed Converter Chassis as figure shown. The power is AC power in the range of 100-240VAC, 50-60Hz (AC power supply). System can install two units with same power type. The factory default has two power module units installed.
Rear Panel
Power Slot B with AC Power Module Power Slot A with AC Power Module
Page 8
6
2.3. LED Indicators
All LED status indicators are located on the front panel of the modules. They display real-time indication of system and operational status.
CPU Panel
LED Description
LED Status Meaning
CPU Ready Blink (Green) System kernel is working correctly PWR Green Power on
Green Power Module A Ready
Good A
Off Power Module A Not Ready Green Power Module B Ready
Good B
Off Power Module B Not Ready Orange Power Module A Fail
Fail A
Off Power Module A Ready Orange Power Module B Fail
Fail B
Off Power Module B Ready Green Ethernet port is connected with the device.
LK/ACT
Blink The port is receiving or transmitting data Yellow Ethernet is linked with Full Duplex mode
FDX
Blink Collision of Packets occurs in the port.
Page 9
7
3. Connecting to the Network
This chapter provides the installation procedure.
3.1. Pre-Installation Requirements
Before to start hardware installation, make sure the installation environment has following items:
PCs with 10/100Base-TX Ethernet cards:
The PC must have a standard Ethernet interface to connect with the Device.
UTP/STP cable with RJ-45 connector:
Check the cable and connectors work properly.
Fiber cable with SC/LC connector:
Check the cable and connector types are correct.
Power outlet:
100 to 240V AC at 50 to 60 Hz power. Make sure that the Device power is accessible and cables can be connected easily.
Dedicated power supply:
Use dedicated power circuits or power conditioners to supply reliable electrical power to the network devices.
A dry cool place:
Keep the device away from moisture. Avoid direct sunlight, heat source, and high amount of electromagnetic interference around.
Mounting tools:
If user intends to mount the device on a rack, make sure have all the tools, such as mounting brackets and screws.
Page 10
8
3.2. Mounting the Device
The 16 Slots Managed Converter Chassis is suitable for an office environment where it can be rack-mounted in standard EIA 19-inch racks or standalone.
3.2.1. Desktop Installation
Set the device on a sufficiently large flat space with a power outlet nearby. And, the surface where user put the device should be clean, smooth, level, and sturdy. Please make sure there is enough spacing around the device to allow attaching of cables, power cord and air circulation.
Attaching Rubber Pads
Make sure mounting surface on the bottom of the device is grease and dust free Remove adhesive backing from Rubber Pads Apply the Rubber Pads to each corner on the bottom of the device. (These footpads can prevent the device from shock/vibration.)
Attaching Rubber Pads to each corner of the Device’s bottom
Page 11
9
3.2.2. Rack Mounting
The 16 Slots Managed Converter Chassis come with a rack-mounted kit and can be mounted in an EIA standard size/19-inch Rack. Perform the following steps for rack mounting the device:
Position one bracket to align with the holes on the side of the device and secure it with the bracket screws. Then attach the remaining bracket to the other side of the Device.
Attach mounting brackets with screws
After attached both mounting brackets, position the device in the rack by lining up the holes in the brackets with the appropriate holes on the rack. Securing the device to the rack with a screwdriver and the rack-mounting screws.
Mount the converter chassis in an EIA standard 19-inch Rack
Note:
For proper ventilation, allow at least 4 inches (10 cm) of clearance on the front and 3.4 inches (8 cm) on the back of the Device. This is especially important for enclosed rack installations.
Page 12
10
3.3. Power On
After all network cables are connected, plug the power cord into the power socket on the back panel and the other end into a power outlet, and then turn the power switch on. Check the front panel Power indicator to see if power is properly supplied. The device with the universal power supply, so there is no more adjustment needed.
3.4. Diagnostic Test
After the installation is completed and AC power is applied to the device properly, the system will automatically perform a diagnostic testing. When the Power LED is on within 4 seconds, the CPU Ready LED will become “Blink” and then the system is ready. On the other hand, if the CPU LED always light on, it means system crash.
3.4.1. Connecting the Device via Local console
The serial console port is a male DB-9 connector that enables the connection from PC or terminal for monitoring and configuring the Device. Use the supplied RS-232 cable with a female DB-9 connector to link the terminal or PC to the console port.(The terminal or PC must support the terminal emulation program)
Connecting the Device to a terminal via RS-232 cable
Page 13
11
After connected to the Console port, turn the PC or terminal on and configure its communications parameters to match the following default characteristics of the console port:
Baud Rate: 9600 bps Data Bits: 8 Stop Bit: 1 Parity: none Flow control: None
Run Hyper Terminal or a terminal emulation program using the above settings for Console Management. After user has finished parameter settings, press Enter and key the login username and password. The default login username and password both is “root”. After authentication, enter “m” to enter main menu.
The Main Menu
Page 14
12
3.4.2. Connecting the Device via Telnet
For the telnet management, user has to set the device IP address that the same network class with PC’s. For example; it factory default IP address is
192.168.16.1, then the PC IP address should be 192.168.16.x
Default Setting:
IP Address: 192.168.16.1 User name: root password: root
For example, click Start Æ Run... from Windows XP desktop Type telnet 192.168.16.1 into Open space and click OK
It shows login screen, enter login name and password, then press Enter
16 Slots Managed Converter Chassis
Login: root Password:
Type 'm' to enter main menu, 'q' to logout or 'exit' to terminate: m ============================================================
[Main]
1. Device Settings
2. Modules Settings
3. Redundant Power Status
4. Event Log
5. SNMP Trap
6. Secure IP for Telnet, HTTP and SNMP
7. Port Counters
8. Fan Status S. Save Current Settings D. Factory Default Settings & Reboot System R. Reboot System U. TFTP Configuration Q. Quit and logout
Select one function (1-8, S, D, R, U, Q):
Page 15
13
3.4.3. Connecting the Device via Web Browser
For the web management, user has to set the device IP address that the same network class with PC’s. For example; it factory default IP address is
192.168.16.1, then the PC IP address should be 192.168.16.x
Default Setting:
IP Address: 192.168.16.1 User name: root password: root
For example, start the Internet Explorer, type http://192.168.16.1 into Address then press Enter
Login window will pop up, type username and password, click OK
Page 16
14
4. Console Management
In this chapter, console management will be described individual function. In fact, console management mode is a line menu mode. User can enter the number of function to configure the function.
4.1. Device Setting
Select Device settings (Type “1” and press “Enter”) from the main menu. It displays the list of device settings items, ex: system name, location, IP and so on. User can enter the number to modify the value.
Device Settings interface
Note: The item “0.1, 0.2, 0.3” can not be modified.
1. Device Name: Set a system name for this device (Character maximum length
is 64)
2. Location: The description for the location of device(Character maximum length is 64)
3. Contact: Description for the contact people of device(Character maximum length is 64)
4. IP Address: The IP address of the device(The default IP is 192.168.16.1)
5. Subnet Mask: The default value is 255.255.255.0
6. Default Gateway: The default value is 192.168.16.254
Page 17
15
7. Change User/Password: User can change to other username or password (The default username and password is root)
8. Get Request Community: The community string for Get (Default is Public)
9. Set Request Community: The community string for Set (Default is Public) A. HTTP Enable: To allow user to configure the converter through Web B. Telnet Enable: To allow user to remote telnet to the converter for configuring C. Set SNTP Config: Configuring the SNTP (Simple Network Time Protocol)
settings. The SNTP allows user to synchronize switch clocks in the Internet
1. Enable/Disable Sntp Client: To enable or disable SNTP function to get the time from the SNTP server
2. Set Sntp Server 1 Ip: Set the SNTP server IP address
3. Set Sntp Server 2 Ip: Set the SNTP server IP address
4. Set Sntp Server 3 Ip: Set the SNTP server IP address
5. Set UTC Timezone: Set the switch location time zone
6. Enable/Disable Daylight Saving: To enable or disable daylight saving function
7. Set Daylight Saving Period: When daylight saving is enabling, user can set up the daylight saving period
8. Set Daylight Saving Offset: Set up the daylight saving time offset value.
A. Enable/Disable Auto Sync to SNTP server: Automatically synchronize time
with the SNTP server
B. Set Auto Sync period: Set up the time that automatically synchronizes time
with SNTP server
Q. Quit: Exit from the current configuration interface
Remember to return the Main Menu to Save the modified settings, and then reboot the device. User may have to press Enter again when the device is finished reboot.
Page 18
16
4.2. Modules Settings
To configure media converter modules operation mode Input “2” and press “Enter “from main menu interface. The system will guide the user to select the module for configuration (Enter the number of module, ex: 1, and then press “Enter”)
After entering the module configuration mode, the module configuration interface will be listed as following figure. 1 ~ 7 selections could be allowed to configure. (From 0.1 ~ 0.5 is read only information. Enter the number of selection to modify the value)
Module setting interface (support TS-1000 module)
1. Module enable/disable: to enable or disable module function(The default is “Enable”)
2. LLF enable/disable: When the RJ-45 or Fiber is link down, it will force the other port disconnect automatically. The forced way is depends on the RJ-45 control Fiber or Fiber control RJ-45 port. The LLF default is “RJ-45 Control FX” and other selections are “Fx Control RJ-45” and “Disable”. On the module that support TS-1000 only can enable or disable the LLF function but can not configure the LLF direction
3. RJ-45 Port Speed/ Duplex: Configuring RJ-45 port speed and mode.(The default is “10M/Half”)
4. Fiber Port Speed/Duplex: Configuring Fiber port speed and mode(The default is “10M/Half”)
5. Reset to default: To reset the module configuration to default value
6. Note: Entering the short description or note for this module
7. TS-1000 Setting: Configuring the TS-1000 functions. Only the module support TS-1000 standard has this configuration item. The module doesn’t support TS-1000 standard don’t have this configuration item
Page 19
17
1. Embedded SSRAM BIST: To test central site converter module status.
When test back value is OK which means the central site converter module is normal. When test back value is fail or didn’t test, it means the central site converter module is fail
2. Power off Alarm (POA): To enable or disable the power off alarm
function. Enable means before the remote converter power off, the remote converter will send out the alarm notice to the central manager converter
3. In-Band Loop Back Test: Checking the fiber port connection status
between remote and central site converter. User needs to set a transfer value, and verify the return value is for verifying if the value the same as user has set
4. Auto Loop Back Test: Checking the fiber port connection status
between remote and central site converter automatically
5. Bandwidth rate control & Terminal Tx port Config: Bandwidth rate
control terminal UTP port
6. Terminal Tx port Table (Read only): Displaying the terminal UTP port
table information
Q. Quit: Exit from the current interface
Page 20
18
4.3. Redundant Power Status
It shows current power supply status. The device has two slots for Power module, on the left is power A, and on the right is power B. In main menu interface, enter “3” and press enter. Then, user will see as the following figure.
Redundant Power Status interface
4.4. Events Log
The system provides 4095 event records
1. Event Log Enabled: The System will start record events when it is “enable”
2. Show Event Log: For viewing event log records. To enable “Event Log Enable” function
3. Delete All Event Log: Removing all event log entries which are stored in system Flash Rom
Q. Quit: Exit from the current interface
Event Log interface
Page 21
19
4.5. SNMP Trap
Configure SNMP Trap station. User can configure up to 4 IP address for trap.
1. Send Trap: To enable or Disable Trap function
2. Trap community: The Trap station must have same community string and can get trap information from this device(The maximum trap community string length is 32 characters. The default community string is “public”)
3~4. Trap IP 1~4: Assign the trap station’s IP address. Only the authorized station can receive the Trap information Q. Quit: Exit from the current interface
SNMP Trap interface
4.6. Secure IP for Telnet, HTTP and SNMP
Configuring security management for Telnet, Web management and SNMP( four would be the maximum number of stations), If the function is enabled, then only the authorized station that with right IP address can manage this device.
Secure IP interface
1. Secure IP for Telnet: To Enable or disable the secure Telnet IP function
2. Secure IP for HTTP: To Enable or disable the secure HTTP IP function
3. Secure IP for SNMP: To Enable or disable the secure SNMP IP function
4~7. Secure IP 1~4: Assigning the IP that can manage the device through Telnet, HTTP and SNMP Q. Quit: Exit from the current interface
Page 22
20
4.7. Port Counters
Viewing UTP and fiber port counter information
1. RJ-45: Viewing all the UTP port counter information
2. Fiber: Viewing all fiber port counter information
3. Reset: Resetting all port counters
Q. Quit: Exit from the current interface
Port Counters interface
4.8. Fan Status
For newest Fan status viewing, press “enter” key to bring it up
Fan Status interface
4.9. Save Current Settings
After modifying, the parameters still not save in the system. User need to do the save action, then all the parameters will be stored in system Flash Rom. The values will be effect after reboot. Enter “R” and press “Enter” key to save the current settings.
Save Current Settings interface
Page 23
21
4.10. Factory Default Settings & Reboot System
To reset the system configuration back to original settings. After reboot, the system configuration will set to default value. Enter “D” and press “Enter” key. There are three optional selections that user can decide to set back to default value or keep current value.
Module settings: User might keep current configure value when the system set to factory default settings. Enter “n” the current configure value will remain after the system set to factory default. Enter “y” the current configure value will be set to the factory default setting. IP settings: User might keep current IP address when the system set to factory default settings. Enter “n” the current IP address will remain after the system set to factory default. Enter “y” the current IP address will be set to the factory default setting.
Factory default settings & Reboot system interface
4.11. Reboot System
To reboot the system without set the system configuration back to default. Enter “R” and press “Enter” key.
4.12. TFTP Configuration
Use TFTP function to update the firmware
1. Set TFTP Server IP: set up the TFTP server IP address
2. Set File Name: set up the firmware file name
3. Update Firmware: execute the TFTP update firmware
Q. Quit: exit from the current interface
TFTP Configuration interface
Page 24
22
5. Web-Based Management
The 16 Slots Managed Converter Chassis support embedded HTML web manage. It offers advanced management features and allows users to manage the device from anywhere on the network through a standard browser such as Microsoft Internet Explorer.
The Web-Based Management supports Internet Explorer 5.0. And, it is applied with Java Applets for reducing network bandwidth consumption, enhance access speed and present an easy viewing screen.
Note:
By default, IE5.0 or later version does not allow Java Applets to activate sockets. In fact, the user has to explicitly modify the browser setting to enable Java Applets to operate network ports.
The user has to download the Java Run Time Environment application to enable Java Applets. Please go to http://java.sun.com, select the Download link and click JAVA SE, select the Java SE Runtime Environment and click Download
System Login
Follow the step below to login system
1. Start Internet Explorer
2. Key in” http://” + “the IP address o
the 16 Slots Managed Co Chassis” (for example, the Factory default is 192. and press “Enter” key.
f
nverter
168.16.1)
. The authentication screen
. Key in the user name and
ot” for
. Press “Enter” or Click ”OK”, then the Home Screen of the Web-based
3
appears
4
password. The default is “ro both
5
management appear right after
Page 25
23
5.1. Home
The Home page displays the configuration of the 16 Slots Managed Converter Chassis.
Device Name: An administratively assigned name of the managed unit that can be modified in SNMP page
Location: The physical location of this managed unit (e.g., laboratory, 3rd floor) that can be modified in SNMP page
Contact: The contact person for this managed unit that can be modified in SNMP page
System Up Time: The time last since the managed unit was re- initialized. It is read only
Sntp Time: Display SNTP time status IP Address: The IP address of the managed unit that can be modified in IP
Config page. Factory Default is 192.168.16.1 Subnet Mask: The subnet mask of the managed unit can be modified in IP
Config page. Default is 255.255.255.0 Default Gateway: The default gateway of the managed unit that can be
modified in IP Config page. Factory Default is 192.168.16.254.
Page 26
24
MAC Address: The MAC address of the managed unit. It is read only Console: Display console parameter information Redundant Power status: Display the redundant power status Firmware Version: The firmware version of the management unit. It is read only.
User can online upgrade the new firmware if the new version is released Hardware Version: The hardware version of the converter. It is read only
Page 27
25
5.2. Modules settings
Modules settings show the modules that installed on the 16 Slots Managed Converter Chassis. In modules settings, it has 4 parts for configure – module, RJ-45 Port, Fiber Port, and Note.
5.2.1. Module
State: It displays the module current status. User can enable or disable the
module state. When the state is disabling, this module cannot be configured Mode: It shows the module mode. The mode was auto detected by system when
installed on the device. When the mode is TS-1000, it means this module supports TS-1000 standard and then click TS-1000 configuration button to configure the TS-1000 function
LLF enable/disable: When the RJ-45 or Fiber is link down, it will force the other port disconnect automatically. The forced way is depends on the RJ-45 control Fiber or Fiber control RJ-45 port. The LLF default is “RJ-45 Control FX” and other selections are “Fx Control RJ-45” and “Disable”. On the module that support TS-1000 only can enable or disable the LLF function but can not configure the LLF direction
Default: set the module back to default value
Page 28
26
5.2.2. TS-1000 setting:
click
conf ig #
button to enter the TS-1000 setting interface
Page 29
27
Central TS-1000 RJ-45 port setting
Link: The port link status Speed: Configure the port speed in force negotiation mode – 100Mbps or
10Mbps Duplex: When the port negotiation is in force mode, user can configure duplex
mode – half or full
Auto-Negotiation: Configure the negotiation mode – auto or force Bandwidth Input Rate: Configure the input bandwidth rate – 10/100Mbps, 2.5/
25Mbps, 5/50Mbps, or 7.5/75Mbps Bandwidth output Rate: Configure the output bandwidth rate – 10/100Mbps,
2.5/ 25Mbps, 5/50Mbps, or 7.5/75Mbps.
Central TS-1000 reset default: Set the configuration back to the default settings
And then, click
Apply
to apply the configuration
Page 30
28
Terminal TS-1000 RJ-45 port setting
When the connection is established between the central site, user are able to configure the terminal site
Link: the port link status Speed: Configure the port speed in force negotiation mode – 100Mbps or
10Mbps Duplex: When the port negotiation is in force mode, you can configure duplex
mode – half or full
Auto-Negotiation: Configure the negotiation mode – auto or force Bandwidth Input Rate: Configure the input bandwidth rate – 10/100Mbps, 2.5/
25Mbps, 5/50Mbps, or 7.5/75Mbps Bandwidth output Rate: Configure the output bandwidth rate – 10/100Mbps,
2.5/ 25Mbps, 5/50Mbps, or 7.5/75Mbps
Terminal TS-1000 reset default: Set the configuration back to the default settings
And then, click
Apply
to apply the configuration
Page 31
29
Verify Test Set up some TS-1000 loop back test
Embedded SSRAM BIST: To test central site converter module status. When test back value is OK, it means the central site converter module is normal. When test back value is fail or didn’t test, it means the central site converter module is fail
In-Band Loop Back Test: Checking the fiber port connection status between remote and central site converter. User needs to set a transfer value and verify the return value same as user has set
Auto Loop Back Test: Checking the fiber port connection status between remote and central site converter automatically
When all items are set, click
Test
button to start the testing
TS-1000 POA setting
Set up the power off alarm function Power off Alarm (POA): To enable or disable the power off alarm function.
Enable -- before the remote converter power off, the remote converter will send out the alarm notice to the central manager converter
And then, click
Apply
to apply the configuration
Page 32
30
5.2.3. RJ-45 Port
Link: Showing the RJ-45 port current link status Nego: Select the negotiation mode
Auto means the system automatically select the speed(Default) Force means the user can select the speed
Speed: Select the speed of port (Make sure the “Nego” column is set as “Force”;
Otherwise, the speed function will be disable) Duplex: Select the Duplex mode. (Make sure the “Nego” column is “Force”;
Otherwise, the duplex function is disabling)
5.2.4. Fiber Port
Link: It shows the RJ-45 port current link status Nego: Select the negotiation mode Speed: Select the speed of port Duplex: Select the Duplex mode Note: A note can be filled in for this module within maximum characters is 32
After modifying, click
Apply
button to apply the new settings
Page 33
31
5.3. Port Counter
Display all port counter information in here
Click
Refresh
button to get current information
Rx Good Pkts(R): Amount of good packets has received/R means RJ-45 port Rx Bad Pkts(R): Amount of good packets has received/R means RJ-45 port Tx Good Pkts(R): Amount of good packets has transmitted/R means RJ-45 port Tx Bad Pkts(R): Amount of bad packet has transmitted/R means RJ-45 port Tx Collision (R): Amount of transmit collision/R means RJ-45 port Rx Collision (R): Amount of receive collision/R means RJ-45 port Rx Good Pkts(F): Amount of good packets has received/F means Fiber port Rx Bad Pkts(F): Amount of good packets has received/F means Fiber port Tx Good Pkts(F): Amount of good packets has transmitted/F means Fiber port Tx Bad Pkts(F): Amount of bad packet has transmitted/F means Fiber port Tx Collision (F): Amount of transmit collision/F means Fiber port Rx Collision (F): Amount of receive collision/F means Fiber port
Page 34
32
5.4. IP Config
Changing of the IP address, subnet mask, and default gateway.
Just simply fill in the new IP address, subnet or default gateway in corresponding column. Then, click
Apply
button to apply new configuration. User should click Save & Reboot to save and reboot system for the new settings to take effect.
Page 35
33
5.5. SNMP
Configuring device name, location, contact, the "get request", "set request" and Trap community string.
The default value of get request, set request and Trap community is “public”. These three parameters must be correctly to performed "get request" from the management unit, "set request" to the management unit and send trap to the
management unit, then click
Apply
button to apply the new settings.
There are up to 4-trap management stations could set to receive the trap packets from the 16-slot chassis converter.
Check marks the “Send traps to the following management stations” and fill in the IP address of trap management station. Remember to set the Trap community while send and receive trap packet between the converters and trap management stations. The trap community must be same between the
converters and trap management station. Last, click
Apply
button to apply
the configuration.
Page 36
34
5.6. Event Log
To enable the event log function and view the event logs
Click
Enable
button to enable event log function
Press
Refresh
button to get the event logs. The system will not auto refresh
the event log
To stop the event log function, click
Disable
button
To clear all event logs in the display frame, press
Clear Al l
button
Page 37
35
5.7. Misc Settings
Enable/Disable Telnet: User can enable or disable the remote telnet function.
The default value is “enable” And then, click
Apply
button to apply new configuration
Enable/Disable HTTP: To enable or disable the remote HTTP function. The
default value is “enable” And then, Click
Apply
button to apply new configuration
Page 38
36
SNTP Configuration: Configure the SNTP (Simple Network Time Protocol)
settings. The SNTP allows user to synchronize switch clocks in the Internet.
Enable/Disable Sntp Client: To enable or disable SNTP function to get
the time from the SNTP server
Sntp Server 1 IP: Set the SNTP server IP address Sntp Server 2 IP: Set the SNTP server IP address Sntp Server 3 IP: Set the SNTP server IP address UTC Timezone: Set the switch location time zone Enable/Disable Daylight Saving: To enable or disable daylight saving
function
Daylight Saving Period: When daylight saving is enabling, you can set
up the daylight saving period
Daylight Saving Offset (minutes): Set up the daylight saving time
offset value
Update System Time: click [Update] button to update the system time SNTP auto sync: To enable or disable automatically synchronize time
with the SNTP server
SNTP auto sync period (minutes): Set up the time that automatically
synchronizes time with SNTP server
Page 39
37
Change Password: Re-set the login username and password. Mark the check
box to enable password change setting
Username (max 15): Key in the new username(The maximum of length
is 15 characters)
Password (max 15): Key in the new password(The maximum of length
is 15 characters)
Confirm Password: Re-enter the new password for confirmation
Security IP: Configure security management for Telnet, Web management and
SNMP, and the maximum number of stations are 4, if the function is enabled then only the authorized station that with right IP address can manage this device.
Secure IP 1~4: Assign the IP that can manage the device through
Telnet, HTTP and SNMP
Secure IP for Telnet: To enable or disable the secure Telnet IP
function
Secure IP for HTTP: To enable or disable the secure HTTP IP function Secure IP for SNMP: To enable or disable the secure SNMP IP
function
Page 40
38
5.8. Save and Reboot
Save Current Settings: To save current settings by click the "Save Current
Settings" and click the [Apply] button, then current settings will be executed automatically
Factory Default Settings & Reboot: To use the factory default settings, check
the "Factory Default Settings& reboot" checkbox then click the[Apply]. There are two optional selections for user to choose from, which are restoring modules back to default value or just IP address back to default value
Default all Modules: Leave it unchecked to keep current configure
value when the system is set as factory default settings
Reset to default IP address: Leave it unchecked to keep current IP
address when the system is set as factory default settings
Reboot system: To reboot system, check the "Reboot System" checkbox then
click the [Apply] button. Please wait a moment (about 15 seconds) then continue to operate the device
Page 41
39
5.9. Upgrade
User can upgrade the firmware by Online or TFTP
Upgrade Firmware (using HTTP to update the firmware)
1. Using http to download the new version of firmware from vendor web site
2. Enter password in the "Password" box (Please note that the default
password is root, and it follows the user password change it could be changed by individual user.)
3. Enter the update firmware file in the "File Path" box. (Clicking
Browse
button to find the file)
4. Click the
Upgrade
button to start updating
Note: If user can't upgrade the new firmware successfully, please try again (Do
not shut down the device)!
Tftp Update (using tftp to update the firmware)
1. TFTP Server IP: set up the TFTP server IP address
2. File Name: set up the firmware file name
3. Click the
Tftp Upgrade
button to start updating.
5.10. Help
In each configuration section, user can click “Help” and the help window will pop up.
Page 42
40
6. SNMP Management
This section describes how to configure and manage the device by accessing Management Information Base (MIB) objects with the SNMP protocol.
SNMP Management
The device’s MIB options are accessible through SNMP. Also, instead of defining a large set of commands, SNMP performs all operations using the “GET”, “GETNEXT” and “SET” commands. And, the SNMP agent that resides on the device can respond to MIB-related queries being sent by the network management software.
The SNMP agent gathers data from the MIB, which keeps information about device parameters and network data. And then, the agent can send traps or notification of certain events to the manager.
SNMP Network
The SNMP manager uses information in the MIB to perform the operations described below:
Operation Description
GET
Retrieve values of SNMP objects from a network device
GETNEXT
Specify an SNMP object in a network device and then retrieve information about the rest of SNMP objects in the device
SET
Modify and store values of SNMP objects in a network device
GET RESPONSE
Replying the GET, GETNEXT, and SET commands are sent by SNMP agent
TRAP
A message sent by an SNMP agent to an SNMP manager indicating some event occurred
Page 43
41
7. Specification
This section provides the specifications of the converter
Standards
IEEE802.3 10BASE-T IEEE802.3u 100BASE-TX and 100BASE-FX IEEE802.3ab Gigabit copper with N-way auto-negotiation IEEE802.3z for Gigabit fiber
Connector
100FX Module:
Fiber: Duplex SC RJ-45: CAT-5 (10/100Mbps) Twisted Pair cable
Gigabit Module:
Fiber: Duplex SC RJ-45 Socket: CAT- 5 (1000Mbps)
CPU Board
RJ-45 for 10/100Mbps, Full/Half Duplex Mini GBIC module: (for 3.3v only) Fiber: Mini GBIC (Duplex LC) RJ-45: CAT- 5 (1000Mbps)
Switch architecture
Store and Forward Internal Packet Gap 960ns Filter illegal Error packet
LED Indicators
CPU Module
CPU Ready, Power Good (A, B) Power Fail (A, B) TX (link/Act, FDX)
100FX Module
Power, TX (Link /Act, speed, FDX), FX (Link /Act, FDX)
100/1000TX to MINI GBIC module
Power, Gigabit Copper (Speed, 1000Mbps, LK/ACT, FDX/COL), Fiber (Link/Act, FDX/COL)
Fiber parameters
Fiber Core
Multi-Mode (62.5/125um, 50/125um) Single-Mode (8/125um, 10/125um)
Wavelength
100Mbps multi-mode: 1310nm / 100Mbps single-mode: 1310nm
Fiber Distance
100Mbps module: Single-Mode Fiber (30 KM) / Multi-Mode (2KM) Gigabit Fiber: SX (Multi-mode) 500 Meters
Optical Transceiver parameter
100Mbps Multi-Mode: TX (–19dBm), RX (-31dBm) Power budget (12dBm) 100Mbps Single-mode (30KM): TX (–15 dBm), RX (-34 dBm) Power budget (19dBm) Gigabit SX Transceiver: TX (–9.5dBm), RX (12.5 dBm) Power budget (3dBm)
Page 44
42
Transparent packet
64 to 1518 Bytes for Non-VLAN Ethernet packet
68 to 1522 Bytes for VLAN-Tag type Ethernet packet
Dimensions
448mmx 279mm x 89mm (W x D x H)
Operational Temperature
0ºC to 45ºC (32ºF to 113ºF)
Transparent packet
64 to 1518 Bytes for Non-VLAN Ethernet packet
68 to 1522 Bytes for VLAN-Tag type Ethernet packet
Power Supply
Redundant and Load Sharing function support (AC)
AC 90~240 VAC, 50/60 HZ @ 20A (max)
EMI & Safety
FCC Class A
CE
8. Optional Module
8.1. Module for FVT-5000 Only
Part No. Model No. Description
532502 FVT-5001
10/100Base-TX to 100Base-FX SC, Multi-mode 2km (TS-1000)
532530 FVT-5301
10/100Base-TX to 100Base-FX SC, Single-mode 30km (TS-1000)
532500 GVT-5000
10/100/1000BaseT to SFP mini-GBIC Converter Module
Note: The TS-1000 applied for 100FX module only
8.2. Converter (TS-1000)
Part No. Model No. Description
532602 FVT-6001
10/100Base-TX to 100Base-FX SC, Multi-mode 2km (TS-1000)
532630 FVT-6301
10/100Base-TX to 100Base-FX SC, Single-mode 30km (TS-1000)