Leuze electronicTechnical description LSIS 22x5
General information
1General information
1.1Explanation of symbols
The symbols used in this technical description are explained below.
Attention!
This symbol precedes text messages which must strictly be observed. Failure to comply
with this information results in injuries to persons or damage to the equipment.
Notice!
This symbol indicates text passages containing important information.
1.2Declaration of Conformity
The code readers of the LSIS 22x series have been developed and manufactured in
accordance with the applicable European standards and directives.
Notice!
You can find the Declaration of Conformity of the devices in chapter 13.1 on page 83.
The manufacturer of the product, Leuze electronic GmbH & Co. KG in D-73277 Owen,
possesses a certified quality assurance system in accordance with ISO 9001.
U
L
C
US
LISTED
6Technical description LSIS 22xLeuze electronic
2Safety notices
2.1General safety notices
Documentation
All entries in this technical description must be heeded, in particular the present chapter
"Safety notices". Keep this technical description in a safe place. It should be available at all
times.
Safety regulations
Observe the locally applicable regulations and the rules of the employer's liability insurance
association.
Repair
Repairs must only be carried out by the manufacturer or an authorized representative.
2.2Safety standards
The code readers of the LSIS 22x series were developed, manufactured and tested in
accordance with the applicable safety standards. They correspond to the state of the art.
2.3Approved purpose
Safety notices
Attention!
The protection of personnel and the device cannot be guaranteed if the device is operated
in a manner not complying with its intended use.
Code readers of the LSIS 22x series are designed for all applications involving industrial
code reading of 1- and 2-dimensional codes, e.g., in storage and materials handling.
In particular, unauthorized uses include:
• in rooms with explosive atmospheres
• operation for medical purposes
Leuze electronicTechnical description LSIS 22x7
TNT 35/7-24V
Safety notices
2.4Working safely
Attention!
Access to or changes on the device, except where expressly described in this operating
manual, is not authorized.
Safety regulations
Observe the locally applicable legal regulations and the rules of the employer's liability
insurance association.
Qualified personnel
Mounting, commissioning and maintenance of the device must only be carried out by qualified personnel.
Electrical work must be carried out by a certified electrician.
Notice!
The code readers of the LSIS 22x family conform with the free group acc.to EN 62471:2008.
Illumination systems of the free group pose no photobiological danger.
8Technical description LSIS 22xLeuze electronic
3Device description
3.1About the code readers of the LSIS 22x series
Code readers of the LSIS 22x series perform numerous tasks in industrial code reading
such as:
• automatic handling and testing machines
• manual reading by having the worker hold up the code
• automatic reading in robot systems
• reading stationary codes
• in analysis automation
• part traceability with code labels
• reading moving codes
• omnidirectional reading of bar codes
Code readers from the LSIS 22x 2 series are available with various interface models:
• LSIS 222 M5M-R1 with RS 232 interface
• LSIS 223 M5M-R1 with USB interface
The extensive options for device configuration using configuration codes enable adaptation
to a multitude of reading tasks.
Device description
Leuze electronicTechnical description LSIS 22x9
TNT 35/7-24V
Device description
Functions overview
General performance characteristics
Sturdy metal housingXX
RS 232 interfaceX
Voltage supply 10 … 30VDCX
USB interfaceX
Voltage supply 5VDCX
Figure 3.1:Application example: omnidirectional reading of 1D-codes
Figure 3.1 shows the omnidirectional reading of 1D-codes.
Device description
Figure 3.2:Application example: reading 1D-codes in automatic handling machines
Figure 3.2 shows the reading of 1D-codes in automatic handling machines.
Leuze electronicTechnical description LSIS 22x11
TNT 35/7-24V
Device description
2D-code reading application examples
Figure 3.3:Application example: reading 2D-codes in presentation mode
Figure 3.3 shows the reading of 2D-codes in presentation mode.
Figure 3.4:Application example: reading of 2D-codes in intralogistics
Figure 3.4 shows the reading of 2D-codes in intralogistics.
12Technical description LSIS 22xLeuze electronic
Device description
3.2Characteristics of the code readers of the LSIS 22x series
Performance characteristics:
• Diverse mounting options with dovetail technology or mounting threads on the rear,
bottom and narrow side of the device.
• Integrated red LED illumination for homogeneous illumination of the rectangular field
of view.
• Green target LED (aimer) for perfect alignment on the code.
• Trigger button for manual triggering.
• Adjustment of all device parameters via configuration codes.
No additional software needs to be installed.
• M12 connection.
• 1 switching input for activation (trigger).
• 1 switching output for the signaling of states.
• Heavy-duty housing of protection class IP 65.
Notice!
Information on technical data and characteristics can be found in chapter 12.1 on page 81.
General information
Code reading occurs by actuating the trigger button, by a trigger signal at the switching
input, by a trigger command via the serial interface and in the permanent reading mode
(presentation mode).
Two LEDs provide optical information on the current operating state of the device.
The read code contents are output via the serial interface and, depending on device,
RS 232 or USB (either keyboard emulation or COM port emulation).
A switching input SWI and a switching output SWO control, e.g., the triggering of the
LSIS 22x or the communication with external devices such as a PLC.
Leuze electronicTechnical description LSIS 22x13
TNT 35/7-24V
Device description
LEDs and buttons
Reading window with
LED illumination
and aimer
4 mounting threads below
Dovetail mounts and
2 mounting threads on
the rear
M12 connection technology
2 dovetail mounts on the
left and right side
3.3Device construction
14Technical description LSIS 22xLeuze electronic
Figure 3.5:Device construction
3.4Stand-alone connection
Turning connector, turnable by 90°
Host interface (RS 232 or USB),
supply voltage + 2 I/O
The code readers of the LSIS 22x series can be operated as individual "stand alone"
devices. The LSIS 22x features an 8-pin M12 connector for the electrical connection of the
supply voltage, the interface and the switching input and output. The connector can be
turned 90°, thereby allowing cables to be laid optimally even in constrained spaces.
Device description
Figure 3.6:Stand-alone connection
Typically, the configuration codes are used to configure the LSIS 22x. Configuration via
online commands is also possible.
The switching input and output are used for reading-gate control and for signaling
successful reading.
The LSIS 22x can exchange data with the host computer via the RS 232 or USB interface.
The framing protocol used for this purpose can be adapted to the specific application. With
the USB interface, keyboard emulation is also possible.
Leuze electronicTechnical description LSIS 22x15
TNT 35/7-24V
Installation and mounting
4Installation and mounting
4.1Storage, transportation
Attention!
When transporting or storing, package the device so tha t it is p rotec ted against collision and
humidity. Optimal protection is achieved when using the original packaging. Heed the
required environmental conditions specified in the technical data.
Unpacking
Check the packaging for any damage. If damage is found, notify the post office or ship-
ping agent as well as the supplier.
Check the delivery contents using your order and the delivery papers:
• Delivered quantity
• Device type and model as indicated on the name plate
•Package insert
The name plate provides information as to what LSIS type your device is. For specific information, please refer to chapter 10.
Name plates of the code readers of the LSIS 22x series
Figure 4.1:Device name plate LSIS 22x
Save the original packaging for later storage or shipping.
If you have any questions concerning your shipment, please contact your supplier or your
local Leuze electronic sales office.
Observe the applicable local regulations when disposing of the packaging materials.
16Technical description LSIS 22xLeuze electronic
4.2Mounting the LSIS 22x
M4, thread depth 3.5mm
The LSIS 22x code readers can be mounted in various ways:
• Via four M4 mounting threads on the bottom of the device
• Via two M4 mounting threads on the rear side of the device
• Via three dovetail mounts on the housing sides and the sensor back.
Appropriate mounting devices are available for all types of fastening.
4.2.1Fastening with M4 screws
Figure 4.2:Fastening options using M4 threaded holes
Installation and mounting
Notice!
Dimensioned drawing can be found in chapter 12.2 on page 82.
Leuze electronicTechnical description LSIS 22x17
TNT 35/7-24V
Installation and mounting
Clamped holding device
for dovetail fitting of the
LSIS 22x
All dimensions in mm
Dovetail fitting
of the LSIS 22x
4.2.2Mounting devices
The following mounting devices are available for fastening the LSIS 22x to the dovetail
fittings:
• BT 8-0mounting block for dovetail (part no. 50036196)
• BTU 300M - D10through hole fastening for rod D = 10 mm or cheek 1.5 … 4mm
• BTU 300M - D12through hole fastening for rod D = 12 mm or cheek 1.5 … 4mm
• BTU 300M - D14through hole fastening for rod D = 14 mm or cheek 1.5 … 4mm
BT 8-0 mounting device
(part no. 50117253)
(part no. 50117252)
(part no. 50117251)
Figure 4.3:BT 8-0 mounting device
18Technical description LSIS 22xLeuze electronic
BTU 300M - D… mounting device
All dimensions in mm
Figure 4.4:BTU 300M - D… mounting device
Installation and mounting
4.3Device arrangement
4.3.1Selecting a mounting location
In order to select the right mounting location, several factors must be considered:
• The reading distance resulting from the code size and code type (see figure 4.5).
• The permissible cable lengths between the LSIS 22x and the host system depending
on which interface is used.
• The control panel with LEDs and trigger button should be very visible and
accessible.
• Mount the LSIS 22x so that the codes that are to be read are not exposed to direct
sunlight or strong ambient light.
When selecting a mounting location, pay further attention to:
• Maintaining the required environmental conditions (temperature, humidity).
• Possible soiling of the viewing window due to liquids, abrasion by boxes, or
packaging-material residues.
• Lowest possible chance of damage to the LSIS 22x by mechanical collision or
jammed parts.
Leuze electronicTechnical description LSIS 22x19
TNT 35/7-24V
Installation and mounting
10 Mil (0.
254
mm) Code 128
010020030050150250350400
2D-Codes
1D-Codes
20 Mil (0.508 mm) Data Matrix Code
10 Mil (0.254 mm) Data Matrix Code
13 Mil (0.330 mm) UPC-A / EAN-13
Reading distance [mm]
4.3.2Determining the reading distance
The typical reading distances are shown in figure 4.5.
In general, the read field increases with the reading distance. This also results in a decrease
in the resolution, however.
For reading distances between 100 mm and 130 mm, particularly homogeneous illumination of the image field is ensured by the integrated illumination.
Figure 4.5:Reading distance as a function of resolution/code type
Notice!
Please notice that the real reading distances are also influenced by factors such as labeling
material, printing quality, scanning angle, printing contrast etc., and may thus deviate from
the reading distances specified here.
Depending on code type, code size, cell or modulus size and position of the code in the
field of view, reading can also occur while in motion.
4.4Cleaning
Clean the housing window of the LSIS 22x with a soft cloth after mounting. Remove all
packaging remains, e.g. carton fibers or Styrofoam balls. In doing so, avoid leaving
fingerprints on the front cover of the LSIS 22x.
Attention!
Do not use aggressive cleaning agents such as thinner or acetone for cleaning the device.
Use of improper cleaning agents can damage the housing window and display.
20Technical description LSIS 22xLeuze electronic
5Electrical connection
The code readers of the LSIS 22x series are connected using an 8-pin, A-coded M12
connector.
Notice!
Ready-made cables are provided for the 8-pin M12 connection.
See "Ready-made cable accessories" on page 78.
For order codes, see chapter 10.3 on page 78.
Electrical connection
Figure 5.1:Location of the electrical connection
Leuze electronicTechnical description LSIS 22x21
TNT 35/7-24V
Electrical connection
5.1Safety notices for the electrical connection
Attention!
Do not open the device yourself under any circumstances! The housing of the LSIS 22x contains no parts that need to be adjusted or maintained by the user.
Before connecting the device please ensure that the supply voltage matches the value printed on the nameplate.
Connection of the device and cleaning must only be carried out by a qualified electrician.
Ensure that the functional earth (FE) is connected correctly. Unimpaired operation is only
guaranteed when the functional earth is connected properly.
If faults cannot be corrected, the device should be removed from operation and protected
against possible commissioning.
Attention!
For UL applications, use is only permitted in class 2 circuits in accordance with the NEC
(National Electric Code).
The code readers of the LSIS 22x series are designed in accordance with safety class III for
supply by PELV (protective extra-low voltage).
Notice!
Protection class IP 65 is only achieved with screwed-on connector!
The LSIS 22x is equipped with an A-coded M12 connector.
•The voltage supply (10 … 30VDC) is connected at pin 1 and pin 3 (VB, GND).
•The switching input is connected at pin 2 (SWI).
•The switching output is connected at pin 4 (SWO).
•The RS 232 interface is the host interface of the LSIS 222 M5M-R1.
It is connected at pin 6 and pin 7 (TXD - data, RXD - data).
•The USB interface is the host interface of the LSIS 223 M5M-R1.
It is connected at pin 6 and pin 7 (D+ - data, D– - data).
Electrical connection
Leuze electronicTechnical description LSIS 22x23
Figure 5.2:Connections of the LSIS 22x
Described in detail in the following are the individual connections.
Attention!
Ensure that the functional earth (FE) is connected correctly. Unimpaired operation is only
guaranteed when the functional earth is connected properly.
Preferably, use the ready-made connection cables from Leuze electronic (see chapter 10.3
on page 78).
Supply voltage
Attention!
For UL applications, use is only permitted in class 2 circuits in accordance with the NEC
(National Electric Code).
The code readers of the LSIS 22x … series are designed in accordance with safety class III
for supply by PELV (protective extra-low voltage).
TNT 35/7-24V
Electrical connection
Switching input
5 V DC (LSIS 223 M5M-R1)
10…30 V DC (LSIS 222 M5M-R1)
LSIS 22x
SWO
VB
GND
max. 20 mA !
Switching output
Connecting functional earth FE
Attention!
Ensure that the functional earth (FE) is connected correctly. Unimpaired operation is only
guaranteed when the functional earth is connected properly. All electrical disturbances
(EMC couplings) are discharged via the functional earth connection.
Switching input/output
The LSIS 22x code readers are equipped with both an opto-decoupled SWI switching input
and SWO switching output.
The LSIS 22x can be activated with the switching input (triggering of code reading).
The switching output is used to signal 'good read' read processes. If a read process is
successful, a high pulse lasting 80 ms is output at the switching output.
External wiring of the switching input
10…30 V DC (LSIS 222 M5M-R1)
5 V DC (LSIS 223 M5M-R1)
VB
SWI
GND
LSIS 22x
Figure 5.3:External wiring of the switching input
External wiring of the switching output
Figure 5.4:External wiring of the switching output
Attention!
24Technical description LSIS 22xLeuze electronic
The switching output is short-circuit proof! However, do not load the switching output of
the LSIS 22x with more than 20mA in normal operation!
5.2.1LSIS 222 M5M-R1 - RS 232 interface
SWI
SWOVB
n. c.
RXD
TXD
GNDFE
7
Host
GND
FE
Tx
Rx
up to 10m!
shield
The RS 232 interface is used primarily for outputting the read and decoded code contents
of the activated code types.
Notice!
Preferably, use the ready-made connection cables from Leuze electronic (see chapter 10.3
on page 78).
Attention!
Observe the maximum cable length of 10m!
If using self-made cables, observe the following notice:
Notice for connecting the RS 232 interface!
Ensure adequate shielding. The entire connection cable must be shielded and earthed.
RS 232 cable assignments
Electrical connection
Figure 5.5:RS 232 pin assignments
MA 2 / MA 4… / MA 2xxi modular interfacing units
To convert the RS 232 to other interfaces (RS 485, RS 422, …) or to connect to fieldbus
systems (PROFIBUS, PROFINET, Ethernet, etc.), an entire series of Leuze connector units
are available .
The KB JST-M12A-8P-3000 system connection cable (part no. 50111225) can be used to
directly connect the LSIS 222 M5M-R1 to these connector units.
Leuze electronicTechnical description LSIS 22x25
TNT 35/7-24V
Electrical connection
SWI
SWOVB
n. c.
D+ Data
D
-
Data
GNDFE
7
Host
4
SH
1
3
2
GND
VB
D+
D
-
rt/RD
ws/WH
gn/GN
sw/BK
up to 3m!
shield
5.2.2LSIS 223 M5M-R1 - USB interface
The USB interface is used primarily for outputting the read and decoded code contents of
the activated code types.
Notice!
Preferably, use the ready-made connection cables from Leuze electronic (see chapter 10.3
on page 78).
Attention!
Observe the maximum cable length of 3m!
If using self-made cables, observe the following notice:
Notice for connecting the USB interface!
Ensure adequate shielding. The entire connection cable must be shielded and earthed. Use
only full-/high-speed data lines acc. to USB 2.0 specifications.
USB cable assignments
Figure 5.6:USB pin assignment
26Technical description LSIS 22xLeuze electronic
6Commissioning
6.1Starting the LSIS 222 M5M-R1 - RS 232 interface
Connect the voltage supply and, if applicable, the switching input and the serial interface
as described in chapter 5.
Notice!
For the host and LSIS 222 to be able to communicate with one another, the interface
parameters (transmission rate, data format) must match!
Factory setting LSIS 222:
• 9600 baud
• 8 data bits
•no parity
•1 stop bit
Set the host interface to the same parameters as the LSIS 222 or set the LSIS 222 to the
same parameters as the host (see chapter 7.1 "Configuration of interface").
Start the Leuze operating software BCLconfig on the connected host (PC/terminal) and call
up the terminal function.
Connect the +10 … +30V DC supply voltage (typ. +24VDC).
The LSIS 222 starts up; readiness for operation is indicated by the illumination of the green
PWR LED.
By default, the LSIS 222 is in manual trigger mode after switching on for the first time.
Press and hold down the trigger button or apply a high signal to the SWI switching input to
now activate the code reader (reading gate open). Further information on possible operating modes can be found in chapter 7.1 on page 30.
Hold a sample code in front of the LSIS 222 at a distance of approx. 100mm (see chapter
13.3 "Sample codes" in the appendix). If the read operation is successful, the green alignment aid and red illumination are switched off. The read result is displayed on the screen.
Close the reading gate by releasing the trigger button or, if applied, removing the high
signal at the SWI switching input.
Commissioning
TNT 35/7-24V
Leuze electronicTechnical description LSIS 22x27
Commissioning
6.2Starting the LSIS 223 M5M-R1 - USB-interface
USB keyboard emulation
Connect the voltage supply and, if applicable, the switching input and the USB interface as
described in chapter 5.
Start the display software (e.g., Editor) on the connected host (PC/terminal).
Connect the +4.75 … +5.25 V DC supply voltage (typ. +5 V DC). A Windows driver is
installed.
The LSIS 223 starts up; readiness for operation is indicated by the illumination of the green
PWR LED.
By default, the LSIS 223 is in streaming presentation mode (permanent reading) after
switching on for the first time; illumination is activated. Further information on possible
operating modes can be found in chapter 7.2 on page 37.
Hold a sample code in front of the LSIS 223 at a distance of approx. 100 mm (see chapter
13.3 "Sample codes" in the appendix). If the read operation is successful, the I/O LED
briefly illuminates green for 80ms. The read result is displayed on the screen.
The LSIS 223 is then immediately again ready for further code readings. The reading gate
remains open.
Notice!
With USB keyboard emulation, data can only be sent in one direction: from the LSIS 22x to
the host.
USB COM port emulation
You can optionally operate the LSIS 223 in the USB COM port emulation operating mode
without considerable configuration effort. You can then operate the code reader with the
BCLconfig software; data can be sent bidirectionally.
First install the USB COM port driver for the LSIS 223, which you can download from the
Leuze home page www.leuze.com
"Configuration code for USB COM port emulation" on page 33.
. Then simply read in the configuration code in figure 7.5
6.3Operating modes
The LSIS 22x can be configured for various operating modes.
• Manual/serial trigger mode
• Presentation mode
• Streaming presentation mode
Notice!
The description of the operating modes and instructions on configuring them can be found
in chapter 7.2 "Configuration of the reading gate control (trigger)" on page 34.
28Technical description LSIS 22xLeuze electronic