Leuze 50127219 Data Sheet

Part no.: 50127219 – AMS 348i 40 SSI – Optical distance sensor

Technical data

Basic data
Series AMS 300i
Application Positioning of skillet systems and side-tracking skates
Characteristic parameters
Optical data
Light source Laser, Red
Laser class 2, IEC/EN 60825-1:2007
Measurement data
Measurement range 200 ... 40,000 mm
Absolute measurement accuracy 2 mm
Reproducibility (3 sigma) 0.9 mm
Max. traverse rate 10 m/s
Collision protection of cranes / gantry cranes Positioning of electroplating plants Positioning of high-bay storage devices
Electrical data
Performance data
Supply voltage 18 ... 30 V, DC
Interface
Type PROFINET, SSI
Profinet
Conformance class B
Protocol PROFINET RT
Switch functionality Integrated
Transmission speed 100 Mbit/s
SSI
Clock frequency 80 ... 800 kHz
Connection
Number of connections 5 Piece(s)
Connection 1
Type of connection Connector
Designation on device BUS IN
Function Data interface
Thread size M12
Type Female
No. of pins 4 -pin
Encoding D-coded
BUS IN
eng 2018-03-27
2 / 13
Part no.: 50127219 – AMS 348i 40 SSI – Optical distance sensor
Connection 2
Type of connection Connector
Designation on device BUS OUT
Function BUS OUT
Thread size M12
Type Female
No. of pins 4 -pin
Encoding D-coded
Connection 3
Type of connection Connector
Designation on device PWR
Function PWR / SW IN/OUT
Thread size M12
Type Male
No. of pins 5 -pin
Encoding A-coded
Connection 4
Type of connection Connector
Designation on device SERVICE
Function Service interface
Thread size M12
Type Female
No. of pins 5 -pin
Encoding A-coded
Connection 5
Type of connection Connector
Designation on device SSI
Function Data interface
Thread size M12
Type Male
No. of pins 5 -pin
Encoding B-coded
Data interface
Voltage supply
SSI
Mechanical data
Design Cubic
Dimension (W x H x L) 84 mm x 166.5 mm x 159 mm
Housing material Metal
Net weight 2,450 g
Type of fastening Through-hole mounting
Operation and display
Type of display LED
LC Display
Operational controls Membrane keyboard
Environmental data
Ambient temperature, operation -5 ... 50 °C
Ambient temperature, storage -30 ... 70 °C
eng 2018-03-27
3 / 13
Part no.: 50127219 – AMS 348i 40 SSI – Optical distance sensor
Relative humidity (non-condensing) 90 %
Certifications
Degree of protection IP 65
Protection class III
Certifications c UL US
Classification
eCl@ss 8.0 27270801
eCl@ss 9.0 27270801
ETIM 5.0 EC001825

Dimensioned drawings

All dimensions in millimeters
eng 2018-03-27
4 / 13
Part no.: 50127219 – AMS 348i 40 SSI – Optical distance sensor
A M 5 screw for alignment B Knurled nut with WAF 4 hexagon socket and M 5 nut for securing C Optical axis D Zero point of the distance to be measured
eng 2018-03-27
5 / 13
Part no.: 50127219 – AMS 348i 40 SSI – Optical distance sensor

Electrical connection

Connection 1 BUS IN
Type of connection Connector
Function Data interface
Thread size M12
Type Female
Material Metal
No. of pins 4 -pin
Encoding D-coded
Pin Pin assignment
1 TD+
2 RD+
3 TD-
4 RD-
BUS IN
Connection 2 BUS OUT
Type of connection Connector
Function BUS OUT
Thread size M12
Type Female
Material Metal
No. of pins 4 -pin
Encoding D-coded
Pin Pin assignment
1 TD+
2 RD+
3 TD-
4 RD-
Connection 3 PWR
Type of connection Connector
Function PWR / SW IN/OUT
Thread size M12
Type Male
Material Metal
No. of pins 5 -pin
Encoding A-coded
Data interface
Voltage supply
eng 2018-03-27
6 / 13
Part no.: 50127219 – AMS 348i 40 SSI – Optical distance sensor
Pin Pin assignment
1 VIN
2 I/O 1
3 GND
4 I/O 2
5 FE
Connection 4 SERVICE
Type of connection Connector
Function Service interface
Thread size M12
Type Female
Material Metal
No. of pins 5 -pin
Encoding A-coded
Pin Pin assignment
1 n.c.
2 RS 232-TX
3 GND
4 RS 232-RX
5 n.c.
Connection 5 SSI
Type of connection Connector
Function Data interface
Thread size M12
Type Male
Material Metal
No. of pins 5 -pin
Encoding B-coded
Pin Pin assignment
1 DATA+
2 DATA-
3 CLK+
4 CLK-
5 FE
SSI

Operation and display

LE
Ds
LED Display Mean
1 PWR Off No supply voltage
ing
eng 2018-03-27
7 / 13
Part no.: 50127219 – AMS 348i 40 SSI – Optical distance sensor
LED Display Meaning
Green, flashing Voltage connected / no measurement value output / initialization running
Green, continuous light Device OK, measurement value output
Red, flashing Device OK, warning set
Red, continuous light No measurement value output
Orange, flashing PROFINET wave function activated
Orange, continuous light Configuration via display
2 BUS Off No supply voltage
Green, flashing Device ok, initialization phase
Green, continuous light Device OK
Red, flashing Communication error
Red, continuous light Bus error
Orange, flashing PROFINET wave function activated
3 BUSINGreen, continuous light Link OK
Orange, flashing Data exchange active
4 BUS
Green, continuous light Link OK
OUT
Orange, flashing Data exchange active

Part number code

Part designation: AMS 3XXi YYY Z AAA
AMS Operating principle:
3XXi Series/interface (integrated fieldbus technology)::
YYY Operating range:
Z Special equipment:
AAA Interface:
AMS: absolute measurement system
300i: RS 422/RS 232 301i: RS 485 304i: PROFIBUS DP / SSI 308i: TCP/IP 335i: CANopen 338i: EtherCAT 348i: PROFINET RT 355i: DeviceNet 358i: EtherNet/IP 384i: Interbus
40: max. operating range in m 120: max. operating range in m 200: max. operating range in m 300: max. operating range in m
H: with heating
SSI: with SSI interface

Accessories

Connection technology - Connection cables
Part no. Designation Article Description
50104169 KB SSI/
IBS-15000-BA
Interconnection cable
Suitable for interface: SSI, Interbus-S Connection 1: Connector, M12, Axial, Female, B-coded, 5 -pin Connection 2: Open end Shielded: Yes Cable length: 15,000 mm Sheathing material: PUR
eng 2018-03-27
8 / 13
Part no.: 50127219 – AMS 348i 40 SSI – Optical distance sensor
Part no. Designation Article Description
50108446 KB SSI/
IBS-30000-BA
50104171 KB SSI/
IBS-5000-BA
50132077 KD U-M12-5A-
V1-020
50132079 KD U-M12-5A-
V1-050
50132080 KD U-M12-5A-
V1-100
Interconnection cable
Interconnection cable
Connection cable Connection 1: Connector, M12, Axial, Female, A-coded, 5 -pin
Connection cable Connection 1: Connector, M12, Axial, Female, A-coded, 5 -pin
Connection cable Connection 1: Connector, M12, Axial, Female, A-coded, 5 -pin
Suitable for interface: SSI, Interbus-S Connection 1: Connector, M12, Axial, Female, B-coded, 5 -pin Connection 2: Open end Shielded: Yes Cable length: 30,000 mm Sheathing material: PUR
Suitable for interface: SSI, Interbus-S Connection 1: Connector, M12, Axial, Female, B-coded, 5 -pin Connection 2: Open end Shielded: Yes Cable length: 5,000 mm Sheathing material: PUR
Connection 2: Open end Shielded: No Cable length: 2,000 mm Sheathing material: PVC
Connection 2: Open end Shielded: No Cable length: 5,000 mm Sheathing material: PVC
Connection 2: Open end Shielded: No Cable length: 10,000 mm Sheathing material: PVC
50135073 KS ET-M12-4A-
P7-020
50135074 KS ET-M12-4A-
P7-050
50135075 KS ET-M12-4A-
P7-100
50135076 KS ET-M12-4A-
P7-150
50135077 KS ET-M12-4A-
P7-300
Connection cable Suitable for interface: Ethernet
Connection 1: Connector, M12, Axial, Male, D-coded, 4 -pin Connection 2: Open end Shielded: Yes Cable length: 2,000 mm Sheathing material: PUR
Connection cable Suitable for interface: Ethernet
Connection 1: Connector, M12, Axial, Male, D-coded, 4 -pin Connection 2: Open end Shielded: Yes Cable length: 5,000 mm Sheathing material: PUR
Connection cable Suitable for interface: Ethernet
Connection 1: Connector, M12, Axial, Male, D-coded, 4 -pin Connection 2: Open end Shielded: Yes Cable length: 10,000 mm Sheathing material: PUR
Connection cable Suitable for interface: Ethernet
Connection 1: Connector, M12, Axial, Male, D-coded, 4 -pin Connection 2: Open end Shielded: Yes Cable length: 15,000 mm Sheathing material: PUR
Connection cable Suitable for interface: Ethernet
Connection 1: Connector, M12, Axial, Male, D-coded, 4 -pin Connection 2: Open end Shielded: Yes Cable length: 30,000 mm Sheathing material: PUR
eng 2018-03-27
9 / 13
Part no.: 50127219 – AMS 348i 40 SSI – Optical distance sensor
Connection technology - Interconnection cables
Part no. Designation Article Description
50106905 KB
ET-30000-SSA
50137077 KSS ET-M12-4A-
M12-4A-P7-020
50137078 KSS ET-M12-4A-
M12-4A-P7-050
50137079 KSS ET-M12-4A-
M12-4A-P7-100
50137080 KSS ET-M12-4A-
M12-4A-P7-150
Interconnection cable
Interconnection cable
Interconnection cable
Interconnection cable
Interconnection cable
Suitable for interface: Ethernet Connection 1: Connector, M12, Axial, Male, D-coded, 4 -pin Connection 2: Connector, M12, Axial, Male, D-coded, 4 -pin Shielded: Yes Cable length: 30,000 mm Sheathing material: PUR
Suitable for interface: Ethernet Connection 1: Connector, M12, Axial, Male, D-coded, 4 -pin Connection 2: Connector, M12, Axial, Male, D-coded, 4 -pin Shielded: Yes Cable length: 1,000 mm Sheathing material: PUR
Suitable for interface: Ethernet Connection 1: Connector, M12, Axial, Male, D-coded, 4 -pin Connection 2: Connector, M12, Axial, Male, D-coded, 4 -pin Shielded: Yes Cable length: 1,000 mm Sheathing material: PUR
Suitable for interface: Ethernet Connection 1: Connector, M12, Axial, Male, D-coded, 4 -pin Connection 2: Connector, M12, Axial, Male, D-coded, 4 -pin Shielded: Yes Cable length: 10,000 mm Sheathing material: PUR
Suitable for interface: Ethernet Connection 1: Connector, M12, Axial, Male, D-coded, 4 -pin Connection 2: Connector, M12, Axial, Male, D-coded, 4 -pin Shielded: Yes Cable length: 15,000 mm Sheathing material: PUR
50135080 KSS ET-M12-4A-
RJ45-A-P7-020
50135081 KSS ET-M12-4A-
RJ45-A-P7-050
50135082 KSS ET-M12-4A-
RJ45-A-P7-100
50135083 KSS ET-M12-4A-
RJ45-A-P7-150
Interconnection cable
Interconnection cable
Interconnection cable
Interconnection cable
Suitable for interface: Ethernet Connection 1: Connector, M12, Axial, Male, D-coded, 4 -pin Connection 2: RJ45 Shielded: Yes Cable, crossed: Connection 1, pin 2 <-> connection 2, pin 3 Cable length: 2,000 mm Sheathing material: PUR
Suitable for interface: Ethernet Connection 1: Connector, M12, Axial, Male, D-coded, 4 -pin Connection 2: RJ45 Shielded: Yes Cable, crossed: Connection 1, pin 2 <-> connection 2, pin 3 Cable length: 5,000 mm Sheathing material: PUR
Suitable for interface: Ethernet Connection 1: Connector, M12, Axial, Male, D-coded, 4 -pin Connection 2: RJ45 Shielded: Yes Cable, crossed: Connection 1, pin 2 <-> connection 2, pin 3 Cable length: 10,000 mm Sheathing material: PUR
Suitable for interface: Ethernet Connection 1: Connector, M12, Axial, Male, D-coded, 4 -pin Connection 2: RJ45 Shielded: Yes Cable, crossed: Connection 1, pin 2 <-> connection 2, pin 3 Cable length: 15,000 mm Sheathing material: PUR
eng 2018-03-27
10 / 13
Part no.: 50127219 – AMS 348i 40 SSI – Optical distance sensor
Part no. Designation Article Description
50135084 KSS ET-M12-4A-
RJ45-A-P7-300
Interconnection cable
Connection technology - Connectors
Part no. Designation Article Description
50038538 KD 02-5-BA Connector Suitable for interface: PROFIBUS DP, MultiNet Plus
50038537 KD 02-5-SA Connector Suitable for interface: PROFIBUS DP, MultiNet Plus
50020501 KD 095-5A Connector Connection: Connector, M12, Axial, Female, A-coded, 5 -pin
Suitable for interface: Ethernet Connection 1: Connector, M12, Axial, Male, D-coded, 4 -pin Connection 2: RJ45 Shielded: Yes Cable, crossed: Connection 1, pin 2 <-> connection 2, pin 3 Cable length: 30,000 mm Sheathing material: PUR
Connection: Connector, M12, Axial, Female, B-coded, 5 -pin
Connection: Connector, M12, Axial, Male, B-coded, 5 -pin
50112155 S-M12A-ET Connector Suitable for interface: Ethernet
Connection technology - Adapters
Part no. Designation Article Description
50109832 KDS ET-M12 /
RJ45 W-4P
Adapter Suitable for: Ethernet
Mounting technology - Other
Part no. Designation Article Description
50107255 MW OMS/AMS 01 Mounting bracket Design of mounting device: Angle, L-shape
Connection: Connector, M12, Axial, Male, D-coded, 4 -pin
Number of connections: 2 Piece(s) Connection 1: Connector, M12, Angled, Female, D-coded, 4 -pin Connection 2: RJ45
Mounting bracket, at system: Through-hole mounting Mounting bracket, at device: Screw type Material: Metal
eng 2018-03-27
11 / 13
Part no.: 50127219 – AMS 348i 40 SSI – Optical distance sensor
Reflective tapes for distance sensors
Part no. Designation Article Description
50115020 Reflexfolie
200x200mm-H
50104364 Reflexfolie
200x200mm-M
50104361 Reflexfolie
200x200mm-S
50115021 Reflexfolie
500x500mm-H
50104365 Reflexfolie
500x500mm-M
Reflector Special design: Heating
Supply voltage: 230 V, AC Design: Rectangular Reflective surface: 200 mm x 200 mm Base material: Aluminum composite Fastening: Mounting plate, Through-hole mounting
Reflector Design: Rectangular
Reflective surface: 200 mm x 200 mm Base material: Aluminum composite Fastening: Through-hole mounting, Mounting plate
Reflective tape Design: Rectangular
Reflective surface: 200 mm x 200 mm Chemical designation of the material: PMMA Fastening: Adhesive
Reflector Supply voltage: 230 V, AC
Design: Rectangular Reflective surface: 500 mm x 500 mm Base material: Aluminum Fastening: Mounting plate, Through-hole mounting Special design: Heating
Reflector Design: Rectangular
Reflective surface: 500 mm x 500 mm Base material: Aluminum composite Fastening: Through-hole mounting, Mounting plate
50104362 Reflexfolie
50115022 Reflexfolie
50104366 Reflexfolie
50108988 Reflexfolie
Deflecting mirror
Part no. Designation Article Description
500x500mm-S
914x914mm-H
914x914mm-M
914x914mm-S
Reflective tape Design: Rectangular
Reflective surface: 500 mm x 500 mm Chemical designation of the material: PMMA Fastening: Adhesive
Reflector Special design: Heating
Supply voltage: 230 V, AC Design: Rectangular Reflective surface: 914 mm x 914 mm Base material: Aluminum composite Fastening: Mounting plate, Through-hole mounting
Reflector Design: Rectangular
Reflective surface: 914 mm x 914 mm Base material: Aluminum Fastening: Through-hole mounting, Mounting plate
Reflective tape Design: Rectangular
Reflective surface: 914 mm x 914 mm Chemical designation of the material: PMMA Fastening: Adhesive
50035630 US 1 OMS Deflecting mirror Type of fastening: Screw type
eng 2018-03-27
12 / 13
Part no.: 50127219 – AMS 348i 40 SSI – Optical distance sensor
Part no. Designation Article Description
50104479 US AMS 01 Deflecting mirror Type of fastening: Through-hole mounting

Notes

Observe intended use!
This product is not a safety sensor and is not intended as personnel protection.
The product may only be put into operation by competent persons.
Only use the product in accordance with its intended use.
WARNING! LASER RADIATION – LASER CLASS 2
Never look directly into the beam!
The device satisfies the requirements of IEC 60825-1:2007 (EN 60825-1:2007) safety regulations for a product of laser class 2 as well as the U.S. 21 CFR 1040.10 regulations with deviations corresponding to "Laser Notice No. 50" from June 24, 2007.
Never look directly into the laser beam or in the direction of reflected laser beams! If you look into the beam path over a longer time period, there is a risk of injury to the retina.
Do not point the laser beam of the device at persons!
Interrupt the laser beam using a non-transparent, non-reflective object if the laser beam is accidentally directed towards a person.
When mounting and aligning the device, avoid reflections of the laser beam off reflective surfaces!
CAUTION! Use of controls or adjustments or performance of procedures other than specified herein may result in hazardous light exposure.
Observe the applicable statutory and local laser protection regulations.
The device must not be tampered with and must not be changed in any way. There are no user-serviceable parts inside the device. Repairs must only be performed by Leuze electronic GmbH + Co. KG.
NOTE
Affix laser information and warning signs!
Laser information and warning signs are affixed to the device. In addition, self-adhesive laser information and warning signs (stick-on labels) are supplied in several languages.
Affix the laser information sheet to the device in the language appropriate for the place of use. When using the device in the US, use the stick-on label with the "Complies with 21 CFR 1040.10" note.
Affix the laser information and warning signs near the device if no signs are attached to the device (e.g. because the device is too small) or if the attached laser information and warning signs are concealed due to the installation position.
Affix the laser information and warning signs so that they are legible without exposing the reader to the laser radiation of the device or other optical radiation.
For UL applications, use is only permitted in Class 2 circuits in accordance with the NEC (National Electric Code).
Use as safety-related component within the safety function is possible, if the component combination is designed correspondingly by the machine manufacturer.
eng 2018-03-27
13 / 13
Loading...