Before using this information and the product it supports, read Appendix B, “Notices“ of this manual. Also
read the product Warranty Information document and the Important Notices document included with the
product.
LIMITED AND RESTRICTED RIGHTS NOTI CE: If data o r soft ware is delivered pursuant a General
Services Administration “GSA” contract, use, reproduction, or disclosure is subject to restrictions set forth
in Contract No. GS-35F-05925.
Lenovo and the Lenovo logo are trademarks of Lenovo in the United States, other countries, or both.
Note: This equipment has been tested and found to comply with the limits for a
class A digital device, pursuant to Part 15 of the FCC rules. These limits are
designed to provide reasonable protection against harmful interference when the
equipment is operated in a commercial environment. This equipment uses,
generates, and can radiate radio frequency energy and if not installed in
accordance with the Installation Guide, may cause harmful interference to radio
communications. Operation of this equipment in a residential area is likely to
cause interference. In this case, the user is required to correct the interference at
their own expense.
Warn ing
Changes or modifications made to this device that are not expressly approved by
the party responsible for compliance could void the user’s authority to operate the
equipment.
CE Mark Warning
BSMI Notice
警告
Class A product
In a domestic environment, this product may cause radio interference. In this case,
the user may be required to take adequate measures.
When using a fiber optic media expansion module, never look at the transmit laser
while it is powered on. Also, never look directly at the fiber TX port and fiber cable
ends when they are powered on.
Ne regardez jamais le laser tant qu’il est sous tension. Ne regardez jamais
directement le port TX (Tramsmission) à fibres optiques et les embouts de câbles à
fibres optiques tant qu’ils sont sous tension.
SFP and SFP+ Regulatory Compliance
Class 1
EN60825-1:2007 2
FCC 21 CFR Chapter 1, Subchapter J in accordance with FDA and CDRH
requirements
Application of CE Mark in accordance with 2004/108/EEC EMC Directive and
the 2006/95/EC Low Voltage Directives
nd
Edition or later, European standard
UL and/or CSA registered component for North America
47 CFR Part 15, Class A when installed into Canary products
This product is not intended for use in the direct field of view at visual display
workplaces.
The acoustic measurement is 63.5 dB (A) for CE0152PB, 63.9 dB (A) for CE0152TB,
65.2 dB (A) for CE0128PB), 65.3 dB (A) for CE0128TB.
Installing the system as described in this guide meets the protective earth
grounding requiremetns of National Electrical Code(NEC), UL/CSA/IEC/EN
60950-1 standards.
Machinenlärminformations-Verordnung—3. GPSGV, der höchste Shalldruckpegel
beträgt 63.5 dB (A) oder weniger(CE0152PB), 63.9 dB (A) oder weniger(CE0152TB),
65.2 dB (A) oder weniger(CE0128PB), 65.3 dB (A) oder weniger(CE0128TB).
Die Installation des Systems wie in dieser Anleitung beschrieben erfüllt die
Anforderungen an die Schutzerdung nach NEC (National Electrical Code), UL /
CSA / IEC / EN 60950-1.
Acoustique information sur le bruit Ordonnance tiers GPSGV, le niveau de pression
acoustique le plus élevé est de 63,5 dB (A) ou moins.
L'installation du système tel que décrit dans ce guide est conforme aux exigences de
mise à la terre de protection des normes NEC (Code national de l'électricité), UL /
CSA / IEC / EN 60950-1.
Risk of explosion if battery is replaced by an incorrect type. Dispose of used
batteries according to the instructions
Risque d'explosion si la piles est remplacée par un type incorrect. Jetez les piles
usagées selon les instructions.
Explosionsgefahr durch batterie bei unbeabsichtigter art. Entsorgen sie
gebrauchte batterien gemäss der anleitung.
Riesgo de explosión si la batería es de un tipo incorrente. Deseche las baterías
usadas según la instrucción.
The following sections provide safety precautions to follow when installing the
switch.
Safety Precautions
For your protection, observe the following safety precautions when setting up your
equipment:
Follow all cautions and instructions marked on the equipment.
Only trained and qualified personnel are allowed to install or to replace this
equipment.
Never push objects of any kind through openings in the equipment. Dangerous
voltages may be present. Conductive foreign objects could produce a short
circuit that could cause fire, electric shock, or damage to your equipment.
This product is intended for restricted access whereby access is controlled
through the use of a means of security (for example, key, lock, tool, badge access)
and personnel authorized for access have been instructed on the reasons for the
restrictions and any precautions that need to be taken.
Remove all metal jewelry, such as rings and watches, before installing or
removing the device.
Do not look directly at the fiber optic cable ends or inspect the cable ends with
an optical lens.
Do not install in direct sunlight, or a damp or dusty place.
Do not expose the device to moisture or water.
Disconnect all power supply cords before servicing.
Electrical Safety Precautions
For your protection, observe the following electrical safety precautions when
setting up your equipment:
Ensure that the voltage and frequency of your power source match the voltage
and frequency inscribed on the equipment’s electrical rating label.
This switch is designed to work with power systems having a grounded neutral.
To reduce the risk of electric shock, do not plug the switch into any other type of
power system. Contact your facilities manager or a qualified electrician if you
are not sure what type of power is supplied to your building.
Not all power cords have the same current ratings. Do not use the power cord
provided with your equipment for any other products or use. Household
extension cords do not have overload protection and are not meant for use with
these switches. Do not use household extension cords with this product.
To prevent electric shock, do not remove the cover of this product. There are no
user-serviceable parts inside. This unit contains hazardous voltages and should
only be opened by a trained and qualified technician.
Do not work on equipment or cables during periods of lightning activity.
Check to see if there are any exposed copper strands coming from the installed
wire. When this installation is done correctly there should be no exposed copper
wire strands extending from the terminal block. Any exposed wiring can
conduct harmful levels of electricity to persons touching the wires.
The power source for the device should be located near the unit and should be
easily accessible.
Circuit Overloading: Consideration should be given to the connection of the
equipment to the supply circuit and the effect that overloading of circuits might
have on overcurrent protection and supply wiring. Appropriate consideration
of equipment nameplate ratings should be used when addressing this concern.
Rack-mount Safety Precautions
For your protection, observe the following rack-mount safety precautions when
setting up your equipment:
Elevated Operating Ambient - If installed in a closed or multi-unit rack
assembly, the operating ambient temperature of the rack environment may be
greater than room ambient. Therefore, consideration should be given to
installing the equipment in an environment compatible with the maximum
ambient temperature (Tma) specified by the manufacturer.
Reduced Air Flow - Installation of the equipment in a rack should be such that
the amount of air flow required for safe operation of the equipment is not
compromised.
Mechanical Loading - Mounting of the equipment in the rack should be such
that a hazardous condition is not achieved due to uneven mechanical loading.
Circuit Overloading - Consideration should be given to the connection of the
equipment to the supply circuit and the effect that overloading of the circuits
might have on overcurrent protection and supply wiring.
Appropriate consideration of equipment nameplate ratings should be used
when addressing this concern.
Reliable Earthing of rack-mounted equipment should be maintained. Particular
attention should be given to supply connections other than direct connections to
the branch circuit (for example, use of power strips).
For safety, equipment should always be loaded from the bottom up. That is,
install the equipment that will be mounted in the lowest part of the rack first,
then the next higher systems, etc.
To prevent the rack from tipping during equipment installation, the anti-tilt bar
on the rack must be deployed.
The mounting brackets provided must be used to mount the device securely in a
The CE0128TB/CE0128PB/CE0152TB/CE0152PB Series switches are targeted for
deployment in Small-to-Medium Businesses (SMB) providing 1 Gbps Ethernet
wire-speed connections that can be used to uplink servers or to interconnect
switches within the local network. For medium-to-large scale enterprise
deployment, these switches provide an excellent means to interconnect edge and
core switches.
Switches in this series support the latest IEEE 802.3az Energy-Efficient Ethernet
(EEE) standard to save power while links are online or to automatically notify
selective ports to enter standby mode when no traffic is transmitted or received.
Package Contents
After purchasing any of the switches in the series, the following items are included
in the package:
One CE0128TB/CE0128PB/CE0152TB/CE0152PB Series Switch
One Open Source Information EULA document
One Regulatory Compliance Notices documents
One DB9-to-RJ45 console cable
One pair of rack-mount brackets
Eight Phillips-head rack-mount bracket screws
Note: If any of the above specified items are not found inside the package contents