CARE AND OPERATION INSTRUCTIONS
F
R
E
E
See Page 2 For Details
SAFETY
GUARD
PROTECTS AGAINST BURNS
AVERTISSEMENT : Assurez-vous de bien suivre les instructions données dans cette notice pour réduire au minimum le risque d’incindie ou d’explosion ou pour éviter tout dommage matériel, toute blessure ou la mort.
WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result, causing property damage, personal injury, or death.
WARNING /AVERTISSEMENT/AVISO
• HOT GLASS WILL CAUSE BURNS.
• DO NOT TOUCH GLASS UNTIL COOLED.
• NEVER ALLOW CHILDREN TO TOUCH GLASS.
• UNE SURFACE VITRÉE CHAUDE PEUT CAUSER DES BRÛLURES.
• LAISSER REFROIDIR LA SURFACE VITRÉE AVANT D'Y TOUCHER.
• NE PERMETTEZ JAMAIS À UN ENFANT DE TOUCHER LA SURFACE VITRÉE.
• EL VIDRIO CALIENTE CAUSARÁ QUEMADURAS.
• USTED DEBE NUNCA TOCAR EL VIDRIO CALIENTE.
• LOS NIÑOS DEBEN NUNCA TOCAR EL VIDRIO.
- Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other appliance.
- WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any
phone in your building.
• Immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fire
department.
- Installation and service must be performed by a qualified installer, service agency or the gas supplier.
- Ne pas entreposer ni utilizer d’essence ni d’autres vapeurs ou liquides inflammables dans le voisinage de cet appareil ou de tout autre appareil.
- QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ :
• Ne pas tenter d’allumer d’appareil.
• Ne touchez à aucan interrupteur. Ne pas vous servir des
téléphones se trouvant dans le bâtiment où vous trouvez.
• Appelez immédiatement votre fournisseur de gaz depuis
un voisin. Suivez les instructions du fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de gaz,
appelez le service des incindies.
- L’installation et l’entretien doivent être assurés par un installateur ou un service d’entretien qualifié ou par le fournisseur de gaz.
P/N 506017-02 Rev. G 02/2012
This manual is one of a set of three supporting this product. Refer to P/N 506015-03 for Installation Instructions and 506019-40 for additional instructions.
Ce manuel est disponible en francais, simplement en faire la demande. Numéro de la pièce 506223-06.
WHAT'S INSIDE
Table of Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Safety and Your Fireplace. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
FREE Safety Guard Offer (Protects Against Burns) . . . . . . . . . . . . . . . . . 2
Important Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Attaching the Safety-in-Operation Warnings . . . . . . . . . . . . . . . . . . . . . 5
[EN FRANÇAIS] L’information de sûreté importante . . . . . . . . . . . . . . . 3–4
Apposition des mises en garde relatives à la sécurité d’utilisation . . . . 5
[EN ESPAÑOL] Información importante de seguridad . . . . . . . . . . . . . . 3–4
Colocación de advertencias de seguridad en operación . . . . . . . . . . . . 5
Wait...
DON’T THROW IT AWAY!
This manual contains
important operating
and safety
information.
INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference.
INSTALLATEUR : Laissez cette notice avec l'appareil. CONSOMMATEUR : Conservez cette notice pour consultation ultérieure.
MLDVTCD Direct-Vent Contemporary Design Gas Fireplaces
MODELS
MILLIVOLT:
Report No. 100353019PRT-002
ELECTRONIC:
MLDVTCD-35NE
Page 2
LENNOX HEARTH PRODUCTS • MERIT® SERIES DIRECT-VENT CONTEMPORARY DESIGN GAS FIREPLACES • MODEL MLDVTCD-35 • CARE AND OPERATION
Thank you for your purchase. We appreciate your business! Please carefully read and follow all instructions in this manual.
Pay special attention to all warnings and safety information.
Following these safety, care, and operation instructions will help ensure many years of dependable and enjoyable service from your fireplace.
FREE
severe burns and injuries by preventing direct contact
To receive your FREE SAFETY GUARD, call 1-800-786-7976
or visit www.lennox.com
TABLE OF CONTENTS
Safety and Your Fireplace. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Important Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Attaching the Safety-in-Operation Warnings . . . . . . . . . . . . . . . . . . 5
Appliance Installation, Service, and Maintenance Notices . . . . . . . . . . 6
Appliance Operation Notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Warranty Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Operation/Care of Your Appliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Variable Flame Adjustment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Front Glass Enclosure Panel, Removal and Installation . . . . . . . . . . . 11
Install Contemporary Media . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Burner Flame Appearance/Sooting . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Burner Air Shutter Adjustments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Millivolt Appliance Checkout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Electronic Appliance Checkout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Replacement Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Product Reference Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Accessory Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Lighting Instructions – Millivolt . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Lighting Instructions – Electronic . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Maintenance Schedule . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Troubleshooting Guide – Millivolt. . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Troubleshooting Guide – Electronic . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Replacement Parts List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
SAFETY GUARD
The Lennox® SAFETY GUARD protects against
with the front glass surface of your fireplace.
(Lennox Hearth Products / Owner Resources)
OFFER
Safety and
Your Fireplace
All parts of your Lennox
Hearth Products fireplace
get EXTREMELY HOT!
To prevent severe burns and injuries, install
a screen or physical barrier to prevent direct contact with the glass.
To order a FREE Lennox® SAFETY GUARD for your fireplace, see details at left.
Follow the safety instructions below
and be sure everyone in your household understands this burn hazard:
• The surfaces on your fireplace get EXTREMELY HOT!
• The glass on the front of the fireplace reaches EXTREMELY HIGH temperatures and can cause severe burns if touched.
• Keep children away from an operating fireplace. Closely supervise children in any room where a fireplace is operating to prevent contact with glass.
• Keep clothing, furniture, gasoline, and other flammable liquids away from the fireplace.
• Even after the gas is turned off, fireplace surfaces remain extremely hot.
Be sure to attach the enclosed Safety-in-
Operation Warnings where you turn on your
fireplace, to help remind everyone of the dangers associated with high temperatures (see page 5).
Read Important Safety Information on
page 4.
2
Page 3
LENNOX HEARTH PRODUCTS • MERIT® SERIES DIRECT-VENT CONTEMPORARY DESIGN GAS FIREPLACES • MODEL MLDVTCD-35 • CARE AND OPERATION
[FRENCH] [SPANISH]
La sécurité et
votre foyer
Toutes les parties de votre foyer
Lennox Hearth Products deviennent
EXTRÊMEMENT CHAUDES !
Afin d'éviter de vous brûler gravement ou de
vous blesser, installez une grille ou une barrière physique pour empêcher tout contact direct avec la vitre.
Pour commander un PANNEAU DE PROTECTION Lennox® GRATUIT pour votre foyer, consultez les détails dans la partie gauche.
Suivez les instructions de sécurité ci-dessous
et veillez à ce que tous les membres de votre famille soient conscients du danger de brûlure encouru :
• Les surfaces de votre foyer deviennent EXTRÊMEMENT CHAUDES !
• La vitre située à l'avant du foyer atteint des températures EXTRÊMEMENT ÉLEVÉES et peut causer de graves blessures en cas de contact.
• Tenez les enfants à l'écart du foyer lorsqu'il fonctionne. Surveillez attentivement les enfants dans les pièces où un foyer est utilisé afin d'éviter qu'ils ne soient en contact avec la vitre.
• Tenez tous les vêtements, les meubles, l'essence et tout autre liquide inflammable à l'écart du foyer.
• Même après fermeture du gaz, les surfaces du foyer restent extrêmement chaudes.
Seguridad y
su chimenea
¡Todas las partes de la chimenea
Lennox Hearth Products se ponen
MUY CALIENTES!
Instale una malla o barrera física para evitar
el contacto directo con el vidrio y prevenir las quemaduras y lesiones graves.
Ver los detalles a la izquierda para ordenar un Lennox® SAFETY GUARD GRATIS para su chimenea.
Siga las instrucciones de seguridad a
continuación y asegúrese de que todos en su hogar sepan acerca de este peligro de quemadura:
• ¡Las superficies de la chimenea se ponen MUY CALIENTES!
• El vidrio delante de la chimenea alcanza temperaturas EXTREMADAMENTE ALTAS y puede causar quemaduras graves si se toca.
• Mantenga a los niños alejados de la chimenea en funcionamiento. Supervise en forma cercana a los niños en cualquier cuarto donde haya una chimenea funcionando para impedir el contacto con el vidrio.
• Mantenga la ropa, mobiliario, gasolina y otros líquidos inflamables alejados de la chimenea.
• Aún después de haber apagado el gas, las superficies de la chimenea permanecen extremadamente calientes.
Veillez à coller les Étiquettes de mise en garde
relatives à la sécurité d'utilisation à l'endroit
où vous utilisez le foyer, pour rappeler à tous les utilisateurs les dangers liés aux températures élevées (voir page 5).
Lisez la section Informations importantes
relatives à la sécurité, page 4.
Asegúrese de colocar las Etiquetas de
advertencia de seguridad de operación en
el lugar donde enciende la chimenea, para que todos recuerden los peligros asociados con las altas temperaturas (ver la página 5).
Lea la Información importante de seguridad
en la página 4.
3
Page 4
LENNOX HEARTH PRODUCTS • MERIT® SERIES DIRECT-VENT CONTEMPORARY DESIGN GAS FIREPLACES • MODEL MLDVTCD-35 • CARE AND OPERATION
Important Safety Information
1. WARNING: Do not operate appliance with the glass front removed, cracked or broken. Replacement of the glass should be done by a licensed or qualified service person .
2. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.
3. Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies.
4. Children and adults should be alerted to the hazards of high surface temperature and should stay away to avoid burns or clothing ignition.
5. Clothing or other flammable material should not be placed on or near the appliance.
6. Young children should be carefully supervised when they are in the same room as the appliance. Toddlers, young children, and others may be susceptible to accidental contact burns. A physical barrier is recommended if there are at-risk individuals in the house. To restrict access to a fireplace or stove, install an adjustable safety gate to keep toddlers, young children, and other at-risk individuals out of the room and away from hot surfaces.
7. Any safety screen or guard removed for servicing an appliance must be replaced prior to operating the appliance.
8. Installation and repair should be done by a qualified service person. The appliance should be inspected before use and at least annually by a professional service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, et cetera. It is imperative that control compartments, burners, and circulating air passageways of the appliance be kept clean. See maintenance instructions on page 10.
L'information de sûreté importante
1. AVERTISSEMENT. Ne pas utiliser l’appareil si le panneau frontal en verre n’est pas en place, est craqué ou brisé. Confiez le remplacement du panneau à un technicien agréé
2. Ne pas utiliser cet appareil s’il a été plongé, même partiellement, dans l’eau. Appeler un technicien qualifié pour inspecter l’appareil et remplacer toute partie du système de commande et toute commande qui a été plongée dans l’eau.
3. En raison des températures élevées, l’appareil devrait être installé dans un endroit où il y a peu de circulation et loin du mobilier et des tentures.
4. Les enfants et les adultes devraient être informés des dangers que posent les températures de surface élevées et se tenir à distance afin d’éviter des brûlures ou que leurs vêtements ne s’enflamment.
5. On ne devrait pas placer de vêtements ni d’autres matières inflammables sur l’appareil ni à proximité.
6. Les jeunes enfants devraient être surveillés étroitement lorsqu’ils se trouvent dans la même pièce que l’appareil. Les tout petits, les jeunes enfants ou les adultes peuvent subir des brûlures s’ils viennent en contact avec la surface chaude. Il est recommandé d’installer une barrière physique si des personnes à risques habitent la maison. Pour empêcher l’accès à un foyer ou à un poêle, installez une barrière de sécurité ; cette mesure empêchera les tout petits, les jeunes enfants et toute autre personne à risque d’avoir accès à la pièce et aux surfaces chaudes.
7. Tout écran ou protecteur retiré pour permettre l’entretien de l’appareil doit être remis en place avant de mettre l’appareil en marche.
8. L’installation et la réparation devrait être confiées à un technicien qualifié. L’appareil devrait faire l’objet d’une inspection par un technicien professionnel avant d’être utilisé et au moins une fois l’an par la suite. Des nettoyages plus fréquents peuvent être nécessaires si les tapis, la literie, et cetera produisent une quantité importante de poussière. Il est essentiel que les compartiments abritant les commandes, les brûleurs et les conduits de circulation d’air de l’appareil soient tenus propres. Voyez les instructions d’entretien à la page 10.
[SPANISH]
Información importante de seguridad
1. ADVERTENCIA: No opere el artefacto con el frente de vidrio quitado, agrietado o roto. Un técnico de servicio licenciado o capacitado debe reemplazar el vidrio.
2. No use este artefacto si alguna de sus partes ha estado bajo agua. Llame de inmediato a un técnico de servicio calificado para que inspeccione el artefacto y reemplace cualquier parte del sistema de control y cualquier control de gas que haya estado bajo agua.
3. Debido a las altas temperaturas, el artefacto debe situarse fuera de las áreas de tráfico y lejos del mobiliario y cortinas.
4. Se debe alertar a los niños y adultos sobre los peligros de las altas temperaturas en la superficie y que se mantengan alejados para evitar quemaduras o ignición de la ropa.
5. No debe colocarse ropa u otros materiales inflamables
4
sobre y cerca del artefacto.
6. Se debe supervisar de cerca a los niños cuando estén en el mismo cuarto que el artefacto. Los niños pequeños, los jóvenes y otras personas pueden ser susceptibles a quemaduras por contacto accidental. Se recomienda instalar una barrera física si hay personas en riesgo en la casa. Para restringir el acceso a una chimenea o estufa, instale una puerta de seguridad ajustable para mantener a los niños pequeños, jóvenes y otras personas en riesgo fuera del cuarto y lejos de las superficies calientes.
7. Cualquier malla o resguardo de seguridad quitado para dar servicio a un artefacto, debe reinstalarse antes de operar el artefacto.
8. Una persona de servicio competente debe realizar la instalación y reparación. Una persona de servicio profesional debe inspeccionar el artefacto antes de usar al menos una vez por año. Se puede requerir limpieza más frecuente debido a la pelusa excesiva del alfombrado, del material de cobijas, etc. Es imprescindible mantener limpios los compartimientos de control, los quemadores y los pasajes de circulación del aire del artefacto. Ver las instrucciones de mantenimiento en la página 10.
Page 5
LENNOX HEARTH PRODUCTS • MERIT® SERIES DIRECT-VENT CONTEMPORARY DESIGN GAS FIREPLACES • MODEL MLDVTCD-35 • CARE AND OPERATION
HOMEOWNER’S INSTRUCTIONS - ATTACHING SAFETY-IN-OPERATION WARNINGS
ATTACHING SAFETY-IN-OPERATION WARNINGS
Your fireplace has been furnished with safety instruc­tion labels that are to be affixed to the operation and control point of the fireplace. A safety instruction label should be affixed to the wall switch plate where the fireplace is turned on and off (See Figure A) or wall thermostat (See Figure B) and if used on the remote control handheld transmitter (Figure C). The warnings should already have been put in place when the fireplace initial set-up was completed. If they are not affixed at these spots, locate the multi-lingual adhesive labels provided with these instructions and proceed as follows:
1. Locate the wall switch or wall thermostat that controls the fireplace (verify the switch operates the fireplace by turning it on and off). Clean the wall switch plate or wall thermostat thoroughly to remove any dust and oils. Affix the label to the surface of the plate of the wall switch that controls the fireplace (Figure A) or the wall thermostat (Figure B). Choose the language primarily spoken in the home.
2. If a remote control is used to control the fireplace, locate the transmitter and clean it thoroughly to remove any dust and oils. Affix the label to the surface of handheld transmitter (Figure C). Choose the language primarily spoken in the home.
3. If you are unable to locate the labels, please call Lennox Hearth Products or your nearest Lennox Hearth Products dealer to receive additional safety instruction labels free of charge.
Cat. No. H8024 Replacement Label Kit
LENNOX HEARTH PRODUCTS 1-800-9-LENNOX
Note: English is red text on clear label. French and Spanish are white text on black label.
APPOSITION DES MISES EN GARDE RELATIVES À LA SÉCURITÉ D’UTILISATION
Votre foyer a été livré avec des étiquettes de sécurité qui doivent être collées à côté des dispositifs de contrôle du foyer. Une étiquette de sécurité doit être collée sur la plaque de l’interrupteur contrôlant l’allumage du foyer (voir Figure A) ou sur le thermostat mural (voir Figure B) et, le cas échéant, sur le boîtier de la télé- commande (Figure C). Les mises en garde auraient dû être collées au moment de l’installation initiale du foyer. Si ce n’est pas le cas, prenez les étiquettes adhésives multilingues fournies avec ces instructions et procédez comme suit:
1. Repérez l’interrupteur ou le thermostat mural qui contrôle le foyer (vérifiez que l’interrupteur contrôle le fonctionnement du foyer en le faisant basculer de Marche à Arrêt, et vice-versa). Nettoyez soigneusement la plaque murale de l’interrupteur ou le thermostat mural pour éliminer la poussière et les traces de graisse ou d’huile. Collez l’étiquette sur la surface de la plaque de l’interrupteur mural qui contrôle le foyer (Figure A) ou du thermostat mural (Figure B). Choisissez la langue qui est principalement parlée dans la résidence du propriétaire.
2. Si une télécommande est utilisée pour contrôler le foyer, nettoyez la soigneusement pour éliminer la poussière et les traces de graisse ou d’huile. Collez l’étiquette sur le boîtier de la télécommande (Figure C). Choisissez la langue qui est principale- ment parlée dans la résidence du propriétaire.
3. Si vous ne trouvez pas les étiquettes, veuillez appeler Lennox Hearth Products ou votre distribu­teur Lennox Hearth Products local pour recevoir gratuitement des étiquettes supplémentaires.
Étiquettes de remplacement, n° cat. H8024
LENNOX HEARTH PRODUCTS 1-800-9-LENNOX
Remarque : Le texte anglais est rouge sur un support transparent. Le texte français et espagnol est blanc sur un support noir.
COLOCACIÓN DE ADVERTENCIAS DE SEGURIDAD EN OPERACIÓN
Su chimenea incluye etiquetas de instrucciones de seguridad que deben colocarse en el punto de operación y control de la chimenea. Se debe colocar una etiqueta de instrucciones de seguridad en la placa del interruptor de pared desde el cual se enciende y se apaga la chimenea
(ver la Figura A) o en el termostato de pared (ver la Figura B) y en el transmisor de control remoto (Figura C) si
se usa. Las advertencias ya deben haberse colocado cuando se completó la instalación inicial de la chimenea. Si no están colocadas en estos lugares, encuentre las etiquetas adhesivas multilingües proporcionadas con estas instrucciones y prosiga de la siguiente manera:
1. Identifique el interruptor o el termostato de pared que controla la chimenea (verifique que el interruptor opera la chimenea encendiéndola y apagándola). Limpie bien la placa del interruptor o el termostato de pared para quitar el polvo y aceite. Pegue la etiqueta en la superficie de la placa del interruptor que controla la chimenea (Figura A) o en el termostato de pared (Figura B). Seleccione el idioma que más se habla en la casa.
2. Si se usa un control remoto para controlar la chimenea, encuentre el transmisor y límpielo bien para quitar el polvo y aceite. Pegue la etiqueta en la superficie del transmisor (Figura C). Seleccione el idioma que más se habla en la casa.
3. Si no puede encontrar las etiquetas, sírvase llamar a Lennox Hearth Products o al distribuidor de Lennox Hearth Products más cercano para recibir etiquetas de instrucciones de seguridad adicionales gratuitas.
Juego de etiquetas de repuesto - Nº de cat. H8024
LENNOX HEARTH PRODUCTS 1-800-9-LENNOX
Nota: La etiqueta en inglés es transparente con texto rojo. Las etiquetas en francés y español son negras con texto blanco.
Figure A
SAFETY LABEL
DIAGRAMS
DIAGRAMMES DES ÉTIQUETTES
DE SÉCURITÉ
Figure B
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
DIAGRAMAS DE ETIQUETAS
DE SEGURIDAD
Figure C
5
Page 6
LENNOX HEARTH PRODUCTS • MERIT® SERIES DIRECT-VENT CONTEMPORARY DESIGN GAS FIREPLACES • MODEL MLDVTCD-35 • CARE AND OPERATION
Appliance Installation, Service, and Maintenance Notices
IMPORTANT: Improper installation, adjustment, alteration, service, or main­tenance can cause injury or property damage. Refer to this manual. For assist­ance or additional information, consult a qualified installer, service agency or the gas supplier.
Only trim kit(s) supplied by the manufac­turer shall be used in the installation of this appliance.
Draft relief openings must not be covered or blocked.
These appliances must not be connected to a chimney or flue serving a separate solid fuel burning appliance.
Any change to this appliance and/or its operating controls is dangerous. Improper installation or use of this appliance can cause serious injury or death from fire, burns, explosion or carbon monoxide poisoning.
Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning are simi­lar to the flu with headaches, dizziness and/or nausea. If you have these signs, obtain fresh air immediately. Turn off the gas supply to the appliance and have it serviced by a qualified professional, as it may not be operating correctly. Some people are more affected by carbon monoxide than others, including pregnant women, people with heart or lung disease or anemia, those under the influence of alcohol, and those at high altitudes.
Turn off gas and electrical power to the fireplace and allow it to cool before clean­ing or servicing the appliance.
Appliance Operation Notices
Do not operate appliance with the glass front removed, cracked, or broken.
These fireplaces are vented gas appli­ances. Do not burn wood or other material in these appliances.
These fireplaces are decorative and are designed to provide supplemental heat. Therefore, it is advisable to have an alternate primary heat source when installed in a dwelling.
This appliance is only for use with the type of gas indicated on rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used.
These appliances are designed to oper­ate on natural gas or propane gas only. The use of other fuels or combinations of fuels will degrade the performance of this system and may be dangerous.
Provide adequate clearances around air openings and adequate accessibility clearance for service and proper opera­tion. Never obstruct the front openings of the appliance.
Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control that has been under water.
The vent termination is hot while in opera­tion and for a period of time following the use of the fireplace. To prevent contact with hot surfaces, we recommend the use of a termination guard. See Page 19 for ordering information.
Warranty Information
Your gas appliance is covered by a limited twenty-year warranty. You will find a copy of the warranty accompanying this manual. Please read the warranty to be familiar with its coverage.
Retain this manual. File it with your other docu­ments for future reference.
Failure to comply with the installation and operating instructions provided will result in an improperly installed and operating appliance, voiding its warranty.
Do not attempt to alter or modify the construction of the appliance or its com­ponents. Any modification or alteration may void the warranty, certification, and listings of this unit.
6
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Page 7
LENNOX HEARTH PRODUCTS • MERIT® SERIES DIRECT-VENT CONTEMPORARY DESIGN GAS FIREPLACES • MODEL MLDVTCD-35 • CARE AND OPERATION
GENERAL INFORMATION
The fireplace models covered in this manual are direct-vent sealed combustion gas fire­places designed for residential application. These direct-vent appliances operate with the combustion chamber completely isolated from the indoor environment.
All air for combustion is brought in from the outside and exhaust gases are vented through the same direct-vent, co-axial (intake/exhaust) vent system.
The Millivolt appliances have a millivolt gas control valve with piezo ignition system. If any optional accessories which require electrical power are being installed, the electrical power must be provided at the time of appliance installation.
The Electronic appliances have a battery backed-up electronic intermittent pilot sys­tem. The battery back-up will allow you to continue operation of the appliance during a power outage.
These appliances comply with National Safety Standards and are tested and listed by ETL/ Intertek (Report No. 100353019PRT-002) to ANSI ZZ21.50 (in Canada, CSA-2.22), and CAN/CGA-2.17-M91 in both USA and Canada, as vented gas fireplaces.
The Installation must conform to local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54-latest edition, or the Natural Gas and Pro­pane Installation Code, CAN/CSA B149.1-latest edition. The appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, the latest edition of the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.1 - latest editions.
BTU Input
Millivolt and electronic models come standard with a manually-modulated gas valve; flame appearance and heat output can be controlled at the gas valve. The BTU inputs for these ap­pliances are shown in Table 1.
Input (BTU/HR) Manually Modulated
Gas Valves (all models)
Model
MLDVTCD-35
Table 1
Input Rate (BTU / HR)
Nat. Gas Prop. Gas
14,500 high
11,500 low
13,500 high
10,500 low
Gas Pressure Requirements
(All Models)
Gas pressure requirements are listed in Tables 2 and 3.
Test gauge connections are provided on the front of the millivolt gas control valve, identi­fied IN for the inlet and OUT for the manifold side (see Figure 3 on Page 9). A 1/8" NPT Test gauge connection is provided at the inlet and outlet (manifold) ports on the electronic gas control valve (see Figure 4 on Page 9).
Inlet Gas Supply Pressure (all models)
Fuel # Minimum Maximum
Natural Gas
Propane
4.5" WC
(1.12 kPa)
11.0" WC
(2.74 kPa)
10.5" WC
(2.61 kPa)
13.0" WC
(3.23 kPa)
Table 2
Manifold Gas Supply Pressure (all models)
Fuel # Low High
Natural
Gas
Propane
(Lo) 2.2" WC
(0.55 kPa)
(Lo) 6.3" WC
(1.57 kPa)
(Hi) 3.5" WC
(0.87 kPa)
(Hi) 10.0" WC
(2.49 kPa)
Table 3
These appliances must be isolated from the gas supply piping system (by closing their individual manual shut-off valve) during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.5 kPa).
These appliances and their individual shut-off valves must be disconnected from the gas supply piping system dur­ing any pressure testing of that system at pressures greater than 1/2 psig (3.5 kPa).
Burn-in Period
During the first few fires in this appliance, there will be some odor due to the curing of the paint and burning off of lubricants used in the manufacturing process. Depending on your use, the burn-in period may take a few hours or a few days.
KEEP YOUR HOUSE WELL VENTILATED DURING THE BURN-IN PROCESS. THE ODOR AND HAZE EMITTED DURING THE BURN-IN PROCESS CAN BE QUITE NOTICEABLE AND MAY SET OFF A SMOKE DETECTOR.
If an optional blower is installed, do NOT turn it on during the burn-in period.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Orifice Sizes
(Sea Level to High Altitude – All Models)
These appliances are tested and approved for installation at elevations of 0-4500 feet (0-1372 meters) above sea level using the standard burner orifice sizes (marked with an "*" in Table 4). For elevations above 4500 feet, contact your gas supplier or qualified service technician.
Deration
At higher elevations, the amount of BTU fuel value delivered must be reduced by either:
• Using gas that has been derated by the gas company.
• Changing the burner orifice to a smaller size as regulated by the local authorities having jurisdiction and by the (USA) National Fuel Gas Code NFPA 54/ANSI Z223.1 - latest edition or, in Canada, the CAN/CSA-B149.1 codes - latest edition.
Install the appliance according to the regulations of the local authorities having jurisdiction and, in the USA, the National Fuel Gas Code NFPA 54 / ANSI Z223.1 - latest edition or, in Canada, the CAN/CSA-B149.1 - latest edition.
NOTE: Flame appearance will diminish 4% per thousand feet.
Burner Orifice Sizes
Elevation 0-4500 feet ( 0-1372 meters)
Model
Series
MLDVTCD-35
Table 4
Nat.Gas
drill size (inches)
#49 (0.073")
21L82 •
* Standard size installed at factory. ** Standard size in LP conversion kit.
• Part /Cat. Number.
Propane
drill size (inches)
0.045"
*
**
75L10
IMPORTANT NOTE!
A white film may develop on the glass enclosure panel during the first few fires as part of the burn-in process.
The first few times you use the fireplace, clean the glass after each use (AFTER THE GLASS HAS COMPLETELY COOLED); otherwise, the white film will bake onto the glass and become difficult to remove.
See “Cleaning Glass” on Page 10.
7
Page 8
LENNOX HEARTH PRODUCTS • MERIT® SERIES DIRECT-VENT CONTEMPORARY DESIGN GAS FIREPLACES • MODEL MLDVTCD-35 • CARE AND OPERATION
OPERATION AND CARE OF YOUR APPLIANCE
WARNING
Young children should be carefully supervised when they are in the same room as the appliance. Toddlers, young children and others may be susceptible to accidental contact burns. A physical barrier is recommended if there are at risk individuals in the house. To restrict access to a fireplace or stove, install an adjustable safety gate to keep toddlers, young children and other at risk individuals out of the room and away from hot surfaces.
AVERTISSEMENT
Les jeunes enfants devraient être surveillés étroitement lorsqu’ils se trou­vent dans la même pièce que l’appareil. Les tout petits, les jeunes enfants ou les adultes peuvent subir des brûlures s’ils viennent en contact avec la surface chaude. Il est recommandé d’installer une barrière physique si des personnes à risques habitent la maison. Pour empêcher l’accès à un foyer ou à un poêle, installez une barrière de sécurité; cette mesure empêchera les tout petits, les jeunes enfants et toute autre personne à risque d’avoir accès à la pièce et aux surfaces chaudes.
On millivolt systems, the piezo igniter, HI/LO flame adjustment knob, and pilot and main gas OFF/ON control knob are located below the glass panel enclosure. The gas valve for electronic systems is also located below the glass enclosure panel. See Figure 1.
Reinstalling Control Compartment Door:
To reinstall, insert the tabs on each side of the door into the corresponding holes in the control compartment opening, one side first then the other. To close, pull the door gently up and close by pushing forward and pushing the top edge down into the groves at the brackets until it locks in place.
The standard controls for appliance operation are located behind the panel below the appli­ance front glass enclosure panel (Figure 1). Optional control switches are also available (see Page 17 - Remote Wall Switch, Remote
Control, Unit Mounted Rocker Switch or Wall Thermostat).
Operation of millivolt and electronic gas con­trol systems are different. Before lighting and operating your appliance determine if you have a millivolt or electronic appliance. Familiarize yourself with the gas control valve that your appliance uses. Refer to Figure 1 for access to the gas control valve.
Millivolt Appliances - Appliances with
Millivolt systems will be fitted with the gas control valve shown in Figure 3.
Gas Shut-Off Valve
Gas Flex Line
Figure 1
Control Compartment Door Tab
Figure 2
Valve
Piezo
Lower Control
Compartment
Spring Door
Latch
Gas Controls/Control Compartment Access
The gas controls can be found behind the control compartment access door.
Removing Control Compartment Door:
Open the panel by gently lifting it upward and forwards. Slide the door, first to one side and then the other, so the tabs clear both of the locating holes.
Electronic Appliances - Appliances with
electronic systems will be fitted with the electronic valve shown in Figure 4.
Millivolt Appliances - To light millivolt ap­pliances refer to Figure 1. Detailed lighting instructions are found on Pages 20 and 21.
Millivolt appliance lighting instructions may also be found on the pull out lighting instruc­tion labels attached to the gas control valve.
Once the pilot is lit, the main burner may be turned ON and OFF using a wall switch, remote control, on unit rocker switch (FRS), or wall thermostat. To operate: Toggle the switch between its ON and OFF positions.
If your millivolt appliance is equipped with an optional remote switch kit (wall switch, remote control, rocker switch, or wall thermostat) and the pilot is lit, the appliance main burner may be turned on and off using the optional switch.
Note: To prevent excessive resistance in burner circuit (which can cause burner operation problems), only one burner control switch should be wired to valve.
8
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Page 9
LENNOX HEARTH PRODUCTS • MERIT® SERIES DIRECT-VENT CONTEMPORARY DESIGN GAS FIREPLACES • MODEL MLDVTCD-35 • CARE AND OPERATION
Gas Inlet
Terminals TPTH, TP and TH
Gas Outlet
PILOT
OUT
VENT
LO
TH
TP
TH
TP
HI
IN
IN
Electronic Appliances
To light electronic appliances refer to the detailed lighting instructions found on Pages 22 and 23 of these instructions. Electronic appliance lighting instructions may also be found on the pull out lighting instruction labels attached to the gas control valve.
If your electronic appliance is equipped with an optional remote wall switch or remote control kit the appliance main burner may be turned on and off with the wall switch or remote control.
If your electronic appliance is not equipped with a wall switch or remote control, the main burner must be turned off and on with a gas control switch located in some other location by the installer. Contact the installer for directions. Check batteries, if installed, routinely (every three months).
TO LIGHT YOUR APPLIANCE IN A POWER
OUTAGE DO THE FOLLOWING:
• Install batteries in battery pack.
• Turn unit mounted switch or wall switch to the ON Position.
• Unit should spark at pilot and light.
• Operate Normally.
• Replace batteries if needed.
• After power is restored, remove batteries.
Main Gas Control Knob
O
L
I
P
N
O
Inlet Pressure Port
T
O
it
L
I
P
O
F
F
OUT
IN
Manifold Pressure Port
O
W
L
H
I
Variable Flame Height Adjustment
Gas Inlet
Terminals TPTH, TP and TH
Figure 3 - SIT Millivolt Gas Valve
Supply Gas Inlet
Pressure-Tap (Manifold)
Regulator Mounting Screw
Burner Stage Terminal
T
Gas Outlet
Gas
Outlet
To Burner
Variable Flame Height Adjustment
All millivolt and electronic appliances are equipped with a variable gas control valve. Flame height for these models may be adjusted through a range between fixed low and high settings while the appliance is in operation.
TPTH TP TH
Adjust the flame height as desired after lighting the appliance by rotating the variable adjustment control knob (HI/LO) located on the front of the valve (refer to Figures 3 and 4).
Note: It is recommended that batteries not be installed in the battery holder until a power outage, or if the appliance is to be operated solely with two (2) "D" batteries.
Pilot Gas Outlet
Refer to the Lighting Instructions on Page 22 to light the appliance in the event of a power failure.
Figure 4 - Dexen Electronic Gas Valve
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Pressure-Tap (Inlet)
Pilot Stage Terminal
Ground (TP)
9
Page 10
LENNOX HEARTH PRODUCTS • MERIT® SERIES DIRECT-VENT CONTEMPORARY DESIGN GAS FIREPLACES • MODEL MLDVTCD-35 • CARE AND OPERATION
MAINTENANCE
(See Maintenance Schedule, Page 24)
Refer to the maintenance schedule for mainte­nance tasks, procedures, frequency and by whom they should be performed. Always verify proper operation of the appliance after servicing.
WARNING
Turn off gas and electrical power to the fireplace and allow it to cool before cleaning or servicing the appliance.
CAUTION: Wear gloves and safety glasses for protection while doing required maintenance.
Verify proper operation after servicing.
S'assurer que l'appareil fonctionne adé­quatement une fois l'entretien terminé.
Always turn off gas to the pilot (millivolt appliances) before cleaning. Before re­lighting, refer to the lighting instructions in this manual. Instructions are also found on a pull-out panel located in the control compartment.
Inspect Venting System
The appliance and venting system should be thoroughly inspected before initial use and at least annually by a qualified service techni­cian (inspection should include ensuring that exhaust or intake passages are unobstructed and vent components are properly assembled and not damaged). Homeowner must contact
a qualified service technician at once if any abnormal condition is observed.
If the venting system is disassembled for any reason, a qualified service technician should follow vent installation instructions for proper reassembly and proper sealing of the venting system components. However, more frequent periodic inspections and cleanings should be performed by the homeowner.
Cleaning Glass
(Also see Front Glass Enclosure Panel, Removal and Installation on Page 11.)
Note: Clean glass after first two weeks of opera- tion (after Burn-In period is over) and then only when necessary and when the fireplace is cool. Wipe surface with clean, dampened, soft cloth. Follow with a dry, soft towel as desired. Take care not to scratch the glass surface.
IMPORTANT: Do not use abrasive clean­ers on glass. Never clean the glass when it is hot.
The viewing glass should be cleaned periodi­cally to remove any build-up caused from the following:
• During start-up, it is normal for condensa­tion to form on the inside of the glass (this condensation and fog will usually disappear in a few minutes). The moisture can cause lint, dust and other airborne particles to cling to the glass surface.
• Initial curing of the high temperature paint and burning off of lubricants used in the manufacturing process may result in a film on the glass.
• A white coating may form on the glass as a result of impurities and minerals in the fuel.
It is recommended that the glass be cleaned two or three times during each heating season, depending on the circumstances present. The following cleaning solutions are approved for use to clean glass:
• Non-ammonia based household cleaner
• 50%-50% mix of white vinegar and water
• Gas fireplace/stove glass cleaner
Inspect Glass Gasket
Visually inspect the gasket on the backside of the glass enclosure panels. The gasket surface must be clean, free of irregularities and seated firmly.
Clean Control Compartment
Keep control compartment clean by vacuuming or brushing at least twice a year. More frequent cleaning may be required due to excessive lint from carpeting, bedding materials, etc. It is important that control compartments, burners and circulating air passageways of the appliance be kept clean.
Clean Sub-Floor And Burner
Carefully remove the contemporary media covering the firebox sub-floor. Place it in a container for future use. Vacuum out any foreign matter (lint, carbon, etc.) on the burner. Ensure the burner ports are “open.” Remove any carbon deposits from the burner outlet using a vacuum cleaner, or a soft bristled brush (i.e. paint brush).
Replacing Contemporary Media
Replace the contemporary media previously removed. See Pages 12 and 13. Use only the proper replacement materials from the manufacturer (see Pages 19 and 27 for order- ing information).
Note: Improper positioning of media can create carbon build-up and will alter the performance of the appliance.
Inspect Wiring
Refer to wiring diagrams on Page 16.
CAUTION: When servicing controls, label all wires prior to disconnection. Wiring errors can cause improper and danger­ous operation. Verify proper operation after servicing.
ATTENTION: Au moment de l'entretien des commandes, étiquetez tous les fils avant de les débrancher. Des erreurs de cáblage peuvent entraîner un fonc­tionnement inadéquat et dangereux.
Inspect and clean all wire connections. Ensure that there is no melting or damage. Inspection should include:
• Terminals at the Valve
• OFF/ON Switch
• (Optional Control Switch) Wall Thermostat, Remote Control or Remote Wall Switch Kit
Inspect Burner Flame Appearance
Ensure that the burner flame appearance resembles the flame shown in Figures 6 and 7 on Pages 13 and 14 and as described in Flame Appearance and Sooting on Page 14. The Homeowner must contact a qualified service technician at once if any abnormal condition is observed.
Small Area Paint Touch-up
Only use a factory supplied paint kit for touch­ups. Paint is available at your local authorized Lennox Hearth Products dealer. Never attempt to paint a hot fireplace.
If the surface later becomes stained or marred, it may be lightly sanded and touched up with spray paint.
10
Page 11
LENNOX HEARTH PRODUCTS • MERIT® SERIES DIRECT-VENT CONTEMPORARY DESIGN GAS FIREPLACES • MODEL MLDVTCD-35 • CARE AND OPERATION
Front Glass Enclosure Panel, Removal and Installation
WARNING
Do not attempt to substitute the materials used on this door, or replace cracked or broken glass.
Handle this glass with extreme care! Glass is susceptible to damage – Do not scratch or handle roughly while reinstall­ing the glass door frame.
The glass door(s) of this appli- ance must only be replaced as a complete unit as provided by the manufacturer. Do not attempt to replace broken, cracked or chipped glass sepa­rately.
Do not attempt to touch the front enclosure glass with your hands while the fireplace is in use.
WARNING
Do not operate appliance with the glass front removed, cracked or broken.
AVERTISSEMENT
Ne pas utiliser l'appareil si le panneau frontal en verre n'est pas en place, est craqué ou brisé.
WARNING
Any safety screen or guard removed for servicing the appli­ance must be replaced prior to operating the appliance.
AVERTISSEMENT
Tout écran ou protecteur retiré pour permettre l’entretien de l’appareil doit être remis en place avant de mettre l’appareil en marche.
Only doors certified with the appliance shall be used.
Seules des portes certifiées pour cet appareil doivent être utilisées.
CAUTION: DO NOT abuse glass door by striking or slamming shut.
These are direct-vent appliances. They are designed to operate only when the front glass enclosure panels are installed. Generally the front glass enclosure panel should not be re­moved except to gain access to the components within the firebox.
Removing Glass Enclosure Panels (see Figure 5)
1. To access the glass door securing latches,
first open the lower control compartment door (Figure 5) by sliding and pulling the bottom panel forward.
2. Pull the latches forward and down to release
them from the door channel.
3. Pull the bottom of the door out a few inches
and grasp it on the right and left. Gently lift to release the door from its channel above the door. Pull the door forward.
4. Retrieve the glass door. Visually inspect the
gasket on the backside of the frame. Gasket surface must be clean, free of irregularities and seated firmly.
5. Inspect the gasket for defects. Ensure it
is properly located. Make sure the bead is not rolled up into the channel at the top of the door, but remains flat against the top of the glass (see Figure 5).
6. Position the door in front of the firebox
opening with the bottom of the door held away from the fireplace (Figure 5). Hook the top flange of the door frame over the top of the firebox frame.
7. Let the bottom of the door frame swing
gently in towards the fireplace ensuring that the gasket seats evenly as the door frame draws shut. Fasten the two latches located underneath the firebox floor to the door's vee-flange. Close both the latches securely.
8. If desired, install the optional hood. Note
the location of the three clips inside the top air channel above the door. The clips are equally spaced on the top surface of the air channel opening. Use a screwdriver to open the clips slightly if needed. Engage the back edge of the eyebrow into the clips to secure.
Ensure Gasket Is Not Rolled
Up Into Door Frame Channel
Header Spacing Top Standoffs
5/8” Nailing Flange
1/2” Nailing Flange
Glass Door
Flush
Hood
Nailing Flange
Glass Door Spring Latch
Control Compartment Panel
Note: When installing the glass door, ensure the spacing on both sides are equal.
Figure 5 -
INSTALLING OR REMOVING GLASS DOOR
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
11
Page 12
LENNOX HEARTH PRODUCTS • MERIT® SERIES DIRECT-VENT CONTEMPORARY DESIGN GAS FIREPLACES • MODEL MLDVTCD-35 • CARE AND OPERATION
INSTALLING CONTEMPORARY MEDIA
NOTE: Turn off all electricity to the appliance before you install contemporary floor media.
WARNING
• DO NOT attempt to install the contemporary media until the appliance installation has been completed, the gas line con­nected and tested for leaks and the initial burner operation has been checked out.
• The size and position of the contemporary media was engi­neered to give the appliance a safe, reliable and attractive flame pattern. Any attempt to use a different media in the fireplace will void the warranty and will result in incomplete combustion, sooting, and poor flame quality.
• Contemporary media get very hot and will remain hot up to one hour after gas supply is turned off. Handle only when contemporary media are cool.
• This appliance is not designed to burn wood. Any attempt to do so could cause irreparable damage to the appliance and prove hazardous to your safety.
• If contemporary media are not installed according to the installation instructions, flame impingement and improper combustion could occur and result in soot and/or excessive production of carbon monoxide (CO), a colorless, odorless, toxic gas.
• Only use materials listed here. Only contemporary media authorized have been tested for use within the firebox and its environment. Do not attempt to use any different materials in the fireplace. Doing so may be dangerous and will void the warranty and will result in incomplete combustion, soot­ing, and poor flame quality.
Table Of Contemporary Media
Cat.
No.
H7536 MTRS Tumbled River Stone
H7537 MCCG-OB
H7538 MBSK
H7578 MCCG-DW
H7579 MCCG-SB
H7581 MBLPK-35ZG
Remove the front glass enclosure panel (see
Removing Glass Enclosure Panels on Page 11).
This fireplace is designed to accept a number of alternate contemporary media options, allowing the homeowner to customize this product to fit any decor.
Install Zen Garden Refractory Panels (MBLPK-35ZG)
1. Porcelain panels come installed in the ap-
pliance. Remove them by bending the tab, sliding the left and right side panels out first, then removing the rear panel.
2. Install Zen Garden panels:
• Remove the lintel by removing two screws.
• Insert the rear panel into firebox and po­sition against the rear wall of the firebox (see Figure 6 - Detail A on Page 13).
• Carefully insert the left side panel into firebox, at a slight angle away from the sidewall. Position the side panel as far back along the wall as it will go (until it is against the rear panel) and lower it into place, while standing it upright and press­ing it down over the knife edge at the rear of the sub-floor. The sub-floor knife edge will cut into the refractory panel. Repeat the same procedure for the right side pan­el (see Figure 6 - Detail B on Page 13).
• Re-install the lintel.
Model Contemporary Media
Name
Contemporary Glass Obsidian Black
Contemporary Beach Sand
Contemporary Glass Diamond White
Contemporary Glass Deep Sea Blue
Merit Liner Kit, Zen Garden
Install Tumbled River Stone (MTRS)
IMPORTANT: Refractory panels should be
installed before any of the contemporary media are installed.
1. Place stones on the firebox sub-floor, in
any atheistically pleasing manner to suite individual taste. See Figure 6 - Detail C on Page 13 for an example.
IMPORTANT: Be sure stones do not im-
pinge on the burner outlet.
Install Crushed Glass And Sand (MCCG and MBSK)
IMPORTANT: Refractory panels should be
installed before any of the contemporary media are installed.
1. Pour out glass or sand on firebox sub-
floor, completely covering the sub-floor. See Figure 6 - Detail D on Page 13 for an example.
IMPORTANT: Avoid letting glass or sand
fall into the burner outlet. Make sure no glass or sand falls into the burner ports.
Install Contemporary Facade
1. Refer to the Facade Installation Instruc-
tions (P/N 506019-40) to install the Con­temporary Facade.
12
Page 13
LENNOX HEARTH PRODUCTS • MERIT® SERIES DIRECT-VENT CONTEMPORARY DESIGN GAS FIREPLACES • MODEL MLDVTCD-35 • CARE AND OPERATION
MLDVTCD-35 REFRACTORY PANELS AND CONTEMPORARY MEDIA PLACEMENT
Rear Zen Garden Panel
Black Obsidian Contemporary Glass
Detail A
Left Zen Garden Panel
Diamond White Contemporary Glass
Detail B
Burner Outlet
Right Zen Garden Panel
Burner Outlet
Tumbled River Stone
(Note: River Stone And Beach Sand May Be Used Together)
Detail C
Contemporary Beach Sand
(Note: Beach Sand And River Stone May Be Used Together)
Detail D
Burner Outlet
Burner Outlet
Figure 6
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
13
Page 14
LENNOX HEARTH PRODUCTS • MERIT® SERIES DIRECT-VENT CONTEMPORARY DESIGN GAS FIREPLACES • MODEL MLDVTCD-35 • CARE AND OPERATION
BURNER ADJUSTMENTS
(QUALIFIED TECHNICIANS ONLY)
Flame Appearance and sooting
Proper flame appearance is a flame which is blue at the base and becomes yellowish-orange in the body of the flame.
When the appliance is first lit, the entire flame may be blue and will gradually turn yellowish­orange during the first 15 minutes of operation. After 15 minutes of operation, if the flame is blue, or if the flame is orange with evidence of sooting (black tip), the air shutter opening may need to be adjusted.
If the air shutter openings is closed too far, sooting may develop. Sooting is indicated by black puffs developing at the tips of very long orange flames. Sooting results in black deposits forming on the appliance inside sur­faces and on exterior surfaces adjacent to the vent termination.
Sooting is caused by incomplete combustion in the flames and lack of combustion air enter­ing the air shutter opening. To achieve a warm yellowish-orange flame with an orange body that does not soot, the shutter opening must be adjusted between these two extremes.
Figure 7 - Burner Flame Appearance Model MLDVTCD-35
(River Stone And Beach Sand With Porcelain Panels Shown)
Air Shutter Adjustment Guidelines
• If there is smoke or soot present, the air shutter opening should be increased.
• The more offsets in the vent system, the larger the air shutter opening will need to be.
• An appliance operated with the air shutter opened too far, may have flames that appear blue and transparent. These weak, blue and transparent flames are termed anemic.
• Propane models may exhibit flames which candle or appear stringy. If this is present and persists, adjust the air shutter to a more closed position, then operate the appliance for a few more minutes to ensure that the flame normalizes and the flames do not appear sooty.
The following chart is provided to aid you in achieving the correct air shutter adjustment for your installation.
Air Shutter Adjustment Guidelines:
Amount of
Primary Air
If air shutter is closed too far
If air shutter is open too far
Flame
Color
Flame will be orange
Flame will be blue
Air Shutter Adjustment
Air shutter gap should be increased
Air shutter gap should be decreased
14
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Page 15
LENNOX HEARTH PRODUCTS • MERIT® SERIES DIRECT-VENT CONTEMPORARY DESIGN GAS FIREPLACES • MODEL MLDVTCD-35 • CARE AND OPERATION
ELECTRONIC
Burner Air Shutter Adjustment Procedure
WARNINGS
Air shutter adjustment should only be performed by a quali­fied professional service tech­nician.
Ensure front glass panel are in place and sealed during adjustment.
CAUTIONS
Soot will be produced if the air shutter is closed too much. Any damage due to carboning resulting from improperly setting the air shutter is not covered under the warranty.
The air shutter door and nearby appliance surfaces are hot. Exercise caution to avoid injury while adjusting flame appearance.
Ensure the air shutter setting is at least equivalent to 1/2 of the air hole exposed when operat­ing the unit with propane gas.
1. Locate and adjust the air shutter to the
standard setting, as shown in Figure 8.
2. Light appliance (follow lighting procedure on
lighting label in control compartment or see the lighting instructions, Pages 20 and 22 in this manual).
3. Allow the burner to operate for at least 15 min-
utes while observing the flame continuously to ensure that the proper flame appearance has been achieved (see Figure 7 on Page 14). If the following conditions are present, adjust accordingly.
• If flame appears weak or sooty, adjust the air shutter, incrementally, to a more open position until the proper flame appearance is achieved.
• If flame stays lowered blue, adjust the air shutter, incrementally, to a more closed position until the proper flame appearance is achieved.
4. Leave the control knob (off/pilot/on) in the
ON position and the burner OFF/ON switch OFF (and remote switches, if applicable).
5. When satisfied that the burner flame ap-
pearance is normal, close the lower control compartment door.
Adjustment Set-Screw
Adjustment Rod Up (closed min. position)
Burner Tube
Air Shutter
Ref. Air shutter Patent: U.S. Pat. 5,553,603
Main Burner Factory Air Shutter
Opening Setting - Inches (millimeter)
Model Natural Gas Propane Gas
MLDVTCD-35 (Closed)
Expose Half Of The Hole
Figure 8 - Burner Air Shutter Adjustment
Millivolt Appliance Checkout
The pilot flame should be steady, not lifting or floating. Flame should be blue in color with traces of orange at the outer edge.
The top 3/8" (10 mm) at the pilot generator (thermopile) and the top 1/8" minimum (tip) of the quick drop out thermocouple should be engulfed in the pilot flame. The flame should project 1" (25 mm) beyond the hood at all three ports. See Figure 9.
To light the burner, refer to the lighting instruc­tions on Page 20.
SIT MILLIVOLT PILOT ASSEMBLY
Proper Pilot Flame Appearance
Hood
Thermocouple
Pilot Nozzels
Thermopile
Igniter Rod
3/8" Min.
(9 mm)
Figure 9
Electronic Appliance Checkout
To light the burner, refer to the lighting instruc­tions on Page 22. Ensure the igniter lights the pilot. The pilot flame should engulf the flame sensor as shown in Figure 10.
ELECTRONIC PILOT ASSEMBLY
Sensor
Igniter
Note: If the igniter is damaged, a replacement kit is available, order Catalog Number 87L54.
Pilot Hood
Figure 10
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
15
Page 16
LENNOX HEARTH PRODUCTS • MERIT® SERIES DIRECT-VENT CONTEMPORARY DESIGN GAS FIREPLACES • MODEL MLDVTCD-35 • CARE AND OPERATION
JUNCTION BOX
W
GR
BK
120 VAC
BK
R
TRANSFORMER 3V
INTERMITTENT ELECTRONIC WIRING DIAGRAM
BROWN
BROWN
BLACK
BATTERY BACK-UP
TO WALL
SWITCH, FRS
OR THERMOSTAT
BLACK (SENSOR)
BLACK (IGNITER)
SPARK TO PILOT IGNITER
IGNITER MODULE
3V
RED
BK
W
GR
OPTIONAL BLOWER SWITCH
FAN
(OPTIONAL)
PILOT
IN
OUT
VENT
LO
HI
TH
TP
TH
TP
IN
ORANGE (THTP)
BLACK (TP)
GREEN (TH)
TP-TH
TP
TH
OPTIONAL APPLIANCE­MOUNTED ON/OFF SWITCH
BK/W(1)
BK/W(1)
WALL-MOUNTED ON/OFF SWITCH (OPTIONAL) THERMOSTAT (OPTIONAL)
JUNCTION BOX
BLACK
W
GR
120 V
AC
WALL MOUNTED CONFIGURATION FOR FAN SWITCH (OPTIONAL)
BK
R
WIRING DIAGRAM MILLIVOLT GAS VALVES
THERMOPILE
GAS VALVE
FAN
(OPTIONAL)
ORDERING REPLACEMENT PARTS
A complete parts list is found at the end of this manual. Use only parts supplied from the manufacturer.
With proper care and maintenance, your appli­ance will provide many years of enjoyment. If you should experience any problem, first refer to the troubleshooting guide in this manual. If the problem persists, contact your Lennox Hearth Products dealer or distributor.
Order parts through your Lennox Hearth Prod­ucts distributor or dealer. Parts will be shipped at prevailing prices at time of order.
When ordering parts, provide the following information:
1. Appliance model number.
2. Appliance serial number.
3. Part number.
4. Part description.
5. Quantity required.
6. Appliance installation date.
If you encounter any problems or have any questions concerning the installation or ap­plication of this system, please contact your dealer or distributor.
Please call Lennox Hearth Products for the phone number of your nearest LHP dealer, who will answer your questions or address your concerns.
LENNOX HEARTH PRODUCTS
PRODUCT REFERENCE INFORMATION
We recommend that you record the important
1508 Elm Hill Pike, Suite 108 Nashville, TN 37210 Visit us at www.Lennox.com 1-800-9-LENNOX
reference information about your fireplace in the space provided below.
PRODUCT REFERENCE INFORMATION
Model Number ________________________________________________________
Serial Number ________________________________________________________
Date Installed _________________________________________________________
Gas Type Used ________________________________________________________
Dealer Name _________________________________________________________
WIRING DIAGRAMS
Wiring diagrams are provided here for reference purposes only. This information is also provided on schematics attached directly to the appliance on a pullout panel located within the control compartment.
CAUTION: LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING CONTROLS. WIRING ERRORS CAN CAUSE IMPROPER AND DANGEROUS APPLIANCE OPERATION.
ATTENTION : AU MOMENT DE L'ENTRETIEN DES COMMANDES, ÉTIQUETEZ TOUS LES FILS AVANT DE LES DÉBRANCHER. DES ERREURS DE CÁBLAGE PEU-VENT ENTRAÎNER UN FONCTIONNEMENT INADÉQUAT ET DANGEREUX.
16
Figure 11
Figure 12
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Page 17
LENNOX HEARTH PRODUCTS • MERIT® SERIES DIRECT-VENT CONTEMPORARY DESIGN GAS FIREPLACES • MODEL MLDVTCD-35 • CARE AND OPERATION
ACCESSORY COMPONENTS
Product Reference Information
Cat.
No.
H7514 MLDVTCD-35NM 86 lb. 10.61 cu. ft.
H7515 MLDVTCD-35NE 86 lb. 10.61 cu. ft.
Model Ship.
Weight
Ship.
Volume
Standard Remote Control System
Digital Wall Thermostat
The wall thermostat kit provides temperature control for optimum comfort.
Wall Thermostat, Millivolt
Cat. No. Model No. Description
H4635 DWTK Wall Thermostat Kit,
White
Unit-Mountable Rocker Switch
The Model RCL (Standard) Remote Control System, features a simplistic OFF/ON control function for the fireplace. This model includes a hand-held transmitter, a remote receiver with wall-mount cover plate and all hardware required to install the unit. The remote receiver can be wall or hearth mounted.
The transmitter has ON and OFF functions that are activated by pressing either button on the face of the transmitter. When a button on the transmitter is pressed, a signal light illuminates briefly to verify that a signal has been sent.
The Model RCL is designed to operate with all mil­livolt ignition systems, as well as electronic ignition systems. It may be installed with use for either natural gas or propane gas appliances. The RCL offers ease of installation and allows you to execute on-off commands to the fireplace effortlessly with one simple motion.
The Model RCL comes complete with detailed operat­ing instructions.
Remote Control Kit, Standard
Cat. No. Model No. Description
H0249 RCL Remote Control System
(Standard)
(ref. Kit Instruction P/N 750127M)
Deluxe Remote Control System
The Model RCL-T (Deluxe) Remote Control System has all of the features of the standard system along with an added easy to read LCD screen which presents access to many enhancements, including; battery power level indicator, timer, mode of operation, thermostatic display including room temperature in either metric of English units, flame indicator and clock. Fully programmable, the Model RCL-T allows for virtual command over nearly all operational and temperature variables, using the hand held remote control transmitter.
The Model RCL-T (Deluxe) remote control system is installed in the same manner as the standard system, may be operated with electronic and millivolt systems with either natural gas or propane gas. The RCL-T comes complete with detailed operating instructions.
Remote Control Kit, Deluxe
Cat. No. Model No. Description
H0251 RCL-STAT Remote Control System
(Deluxe)
(ref. Kit Instruction P/N 750129M)
This rocker switch kit can be installed directly in the gas valve mounting bracket (millivolt gas valve equipped fireplaces) to provide On/Off operation in lieu of a wall switch.
Rocker Switch Kit
Cat. No. Model No. Description
80L41 FRS Rocker Switch Kit
(ref. Kit Instruction P/N 750037M)
OFF/ON Wall Switch Kit
The OFF/ON wall switch kit may be used to control the operation of the fireplace burner or blower. Install the OFF/ON wall switch in a convenient location near the fireplace.
White Wall Switch Kit
Cat. No. Model No. Description
85L87 FWSK OFF/ON Wall Switch Kit
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Variable Speed Wall Switch
Provides variable speed control if optional blower kit is purchased.
Variable Speed Wall Switch
Cat. No. Model No. Description
045571H VSWS Rocker Switch Kit
17
Page 18
LENNOX HEARTH PRODUCTS • MERIT® SERIES DIRECT-VENT CONTEMPORARY DESIGN GAS FIREPLACES • MODEL MLDVTCD-35 • CARE AND OPERATION
ACCESSORY COMPONENTS CONTINUED
Pull Screen Panel Kit
This easy to install optional decorative screen kit installs over the standard glass enclosure panel. These screen kits cannot be used in conjunction with
Cat. No. Model No. Models Where Used
H6113 PSFPKM35 MLDVTCD-35
Screen Panel Kits
the arch door kits or door frame kits.
Style View Screen Doors -
These Style View doors are easy to install and will not require hardware to attach them to the standard glass door frame. The Style View door installs over the standard glass enclosure panel and provides a barrier to prevent direct contact with the hot glass surface. The door includes heavy duty magnet door latches and functional twin-pane screen doors.
Arch Pane Design
ARCH PANE DESIGN KITS
Cat. No. Model Description Model Series
APDML35C
H6106
APDML35SP
H6107
(ref. Kit Instruction P/N 750215M)
35” Arch Pane Door, Charcoal
35” Arch Pane Door, Satin Pewter
MLDVTCD-35
Cat. No. Model Description Model Series
H6098 SPDML35C
SPDML35SP
H6099
Square Pane Design
SQUARE PANE DESIGN KITS
35” Square Pane Door, Charcoal
35” Square Pane Door, Satin Pewter
MLDVTCD-35
Trim
Frame
Base
Barrier Screen Panel Kit
This easy to install optional screen panel installs over the standard glass enclosure panel and provides a barrier to prevent direct contact with the hot glass surface. These screen panels cannot be used in conjunction with the arch door kits or door frame kits.
Contemporary Facade Kit
This easy to install optional Contemporary Facade kit installs over the front face of the MLDVTCD-35 fireplace.
Barrier Screen Panel Kits
Cat. No. Model No. Models Where Used
H6095 35MSPK MLDVTCD-35
(ref. Kit Instruction P/N 750042M)
Contemporary Facade Kits
Cat. No. Model No. Description
H7732 CDFBBK-35 Facade Base, Black
H7733 CDFBSS-35 Facade Base, Stainless
H7730 CDFFBK-35 Facade Frame, Black
H7731 CDFFSS-35 Facade Frame, Stainless
H7727 CDTKBK-35 Facade Trim, Black
H7728 CDTKSS-35 Facade Trim, Stainless
H7729 CDTKBR-35 Facade Trim, Polished Brass
(ref. Kit Instruction P/N 506019-40)
18
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Page 19
LENNOX HEARTH PRODUCTS • MERIT® SERIES DIRECT-VENT CONTEMPORARY DESIGN GAS FIREPLACES • MODEL MLDVTCD-35 • CARE AND OPERATION
ACCESSORY COMPONENTS CONTINUED
Termination Shroud
(Fits H1968)
(ref. Kit Instruction P/N 750246M)
Deluxe Termination
Guard (Fits 94L10)
(ref. Kit Instruction P/N 750055M)
Square Termination
Guard (Fits 94L10)
(ref. Kit Instruction P/N 750109M)
Termination Guard Kits
The vent termination guards may be used to cover the vent termination on the exterior of the home to mini­mize exposure to the hot surface of the termination.
Refractory Panel Kit
The Zen Garden Refractory Panel Kit includes panels similar in appearance to the illustration. The panels have vertical design features in relief.
Refractory Panel Kit
Cat.
Model No. Description
No.
H7581 MBLPK-35ZG Zen Garden MLDVTCD-35
(ref. Kit Instruction P/N 506019-36)
Bag of Contemporary Media (Stone, Sand or Glass)
Replacement contemporary materials or beach sand are available for use with these appliances. Order kits as part of the periodic maintenance of the appliance.
Replacement Contemporary Media
Cat. No. Model No. Description
H7536 MTRS Tumbled River Stone
H7538 MBSK Contemoporary Beach Sand
H7537 MCCG-OB Contemoporary Glass,
H7578 MCCG-DW Contemoporary Glass,
H7579 MCCG-SB Contemoporary Glass,
(ref. Kit Instruction P/N 506019-29)
(ref. Kit Instruction P/N 506019-31)
Obsidian Black
(ref. Kit Instruction P/N 506019-30)
Diamond White
(ref. Kit Instruction P/N 506019-30)
Deep Sea Blue
(ref. Kit Instruction P/N 506019-30)
Forced Air Kit
The FBK-100 blower provides constant velocity forced air circulation. The FBK-200 assembly with variable speed, wall-mountable switch provides variable speed forced air circulation.
Forced Air Blower Kits
Cat.
Model No. Description
No.
80L84 FBK-100 Blower, Standard
80L85 FBK-200 Blower, Variable Speed
(ref. Kit Instruction P/N 750028M)
(single speed)
(w/wall-mounted switch)
P
T
A
N
I
Touch-Up Paint Kit
Repair of minor scratches and discoloration of the appliance black painted surfaces may be accomplished with the touch-up paint kit.
Touch-Up Paint Kits
(all models)
Cat. No. Model No. Description
90L73 TPK-B Touch-Up Paint (Black)
(ref. Kit Instruction P/N 750050M)
Termination Guard Kits
(all models)
Cat. No. Model No. Description
H5820 4.5HTSK Termination Shroud
87L02 SV4.5HGS Termination Guard,
Deluxe
17M52 SV4.5HGS-1 Termination Guard,
Square
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
19
Page 20
LENNOX HEARTH PRODUCTS • MERIT® SERIES DIRECT-VENT CONTEMPORARY DESIGN GAS FIREPLACES • MODEL MLDVTCD-35 • CARE AND OPERATION
H
I
L
O
W
TPTH TP TH
P
I
L
O
T
P
I
L
O
T
O
N
it
O
F
F
OUT
IN
LIGHTING INSTRUCTIONS – MILLIVOLT GAS VALVE
FOR YOUR SAFETY READ BEFORE LIGHTING
WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY
RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.
A. This appliance has a pilot which must be lighted with a piezo
igniter. When lighting the pilot, follow these instructions exactly.
B. BEFORE LIGHTING smell all around the appliance area for gas.
Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electric switch; do not use any phone in your
building.
LIGHTING INSTRUCTIONS
1. STOP! Read the safety information above on this page.
2. Access the lower control compartment.
3. Turn remote wall switch to “OFF.”
4. Verify main line shut-off valve is open.
5. Push in gas control knob slightly and turn clockwise
to “OFF.”
6. Wait five (5) minutes to clear out any gas. Then smell for gas, includ-
7. Push in gas control knob slightly and turn counterclockwise
8. Push in control knob all the way and hold in. Immediately light the
Immediately call your gas supplier from a neighbor’s phone.
Follow the gas supplier’s instructions.
If you cannot reach your gas supplier, call the fire department.
C. Use only your hand to push in or turn the gas control knob.
Never use tools. If the knob will not push in or turn by hand, do not try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or an explosion.
D. Do not use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.
ing near the floor. If you smell gas, STOP! Follow “B” in the safety information above (to the left) on this label. If you don’t smell gas, go to the next step.
to “PILOT.”
pilot by triggering the spark igniter (pushing the button) until pilot lights. Continue to hold the control knob in for about 1-1/2 minutes after the pilot is lit. Release knob and it will pop back up. Pilot should remain lit. If it goes out, repeat steps 5 through 8.
If knob does not pop up when released, stop
and immediately call your service technician or gas supplier.
If pilot will not stay lit after several
tries, turn the control knob to “OFF” and call your service technician or gas supplier.
20
Note: Knob cannot be turned from “PILOT” to “OFF” unless the knob is pushed in slightly. Do not force.
1. Turn remote wall switch “OFF.” The pilot will remain lit for nor-
mal service.
2. For complete shutdown, turn remote wall switch to “OFF.”
3. Access the lower control compartment.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
9. Turn gas control knob counterclockwise to “ON.”
10. Close lower control compartment.
11. If the appliance will not operate, follow the instructions "To Turn Off
Gas To Appliance" and call your service technician or gas supplier.
TO TURN OFF GAS TO APPLIANCE
4. Depress gas control knob slightly and turn clockwise
to “OFF.” Do not force.
5. Close lower control compartment.
Page 21
LENNOX HEARTH PRODUCTS • MERIT® SERIES DIRECT-VENT CONTEMPORARY DESIGN GAS FIREPLACES • MODEL MLDVTCD-35 • CARE AND OPERATION
H
I
L
O
W
TPTH TP TH
P
I
L
O
T
P
I
L
O
T
O
N
it
O
F
F
OUT
IN
INSTRUCTIONS D’ALLUMAGE – VANNE GAZ MILLIVOLT
POUR PLUS DE SÉCURITÉ, LIRE AVANT D’ALLUMER
AVERTISSEMENT. QUICONQUE NE RESPECTE PAS À LA LETTRE LES INSTRUCTIONS DANS LA PRÉSENTE NOTICE RISQUE
DE DÉCLENCHER UN INCENDIE OU UNE EXPLOSION ENTRAÎNANT DES DOMMAGES, DES BLESSURES OU LA MORT.
A. Cet appareil est muni d’une veilleuse qui doit être allumée avec un
allumeur piézo-électrique. Lorsque vous allumez la veilleuse, suivre exactement ces instructions.
B. AVANT L’ALLUMAGE: Avant d’allumer la veilleuse, reniflez tout autour
de l’appareil pour déceler une odeur de gaz. Reniflez près du plancher, car certains gaz sont plus lourds que l’air et peuvent s’accumuler au niveau du sol.
QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ :
• Ne pas tenter d’allumer d’appareil.
• Ne touchez à aucun interrupteur ; ne pas vous servir des téléphones se trouvant dans le bâtiment.
INSTRUCTIONS D'ALLUMAGE
1. ARRÊTEZ ! Lisez les instructions de sécurité sur la portion supéri-
eure de cette étiquette..
2. Ouvrez le compartiment de contrôle du bas.
3. Tournez l’interrupteur mural à la position d’arrêt “OFF”.
4. Assurez-vous que la soupape d’arrêt de la canalisation principale est
ouverte.
5. Enfoncez légèrement le bouton de réglage du gaz et tournez-le dans
le sens des aiguilles d’une montre jusqu’à la position d’arrêt “OFF”.
Appelez immédiatement votre fournisseur de gaz depuis un voisin.
Suivez les instructions du fournisseur.
Si vous ne pouvez rejoindre le fournisseur, appelez le service des
incendies.
C. Ne pousser ou tourner la manette d’admission du gaz qu’à la main. Ne
jamais employer d’outil à cette fin. Si la manette reste coincée, ne ten­tez pas de la réparer; appelez un technicien qualifié. Quiconque tente de forcer la manette ou de la réparer peut provoquer une explosion ou un incendie.
D. N’utilisez pas cet appareil s’il a été plongé dans l’eau, même partielle-
ment. Faites inspecter l’appareil par un technicien qualifié et remplacez toute partie du système de contrôle et toute commande qui ont été plongés dans l’eau.
8. Enfoncez le bouton de réglage jusqu’au fond et gardez-le enfoncé.
Allumez immédiatement la veilleuse en déclenchant l’allume-gaz à étincelle (en poussant le bouton) jusqu’à ce que la veilleuse s’enflamme. Continuez de tenir le bouton de réglage enfoncé pen­dant environ 90 secondes après l’allumage de la veilleuse. Relâ­chez le bouton et il sortira subitement. La veilleuse devrait rester allumée. Si elle s’éteint, répétez les étapes 5 à 8 inclusivement.
Si le bouton ne sort pas automatiquement après avoir été relâché,
arrêtez immédiatement et téléphonez à votre technicien de service ou à votre fournisseur de gaz.
Remarque: Il est impossible de tourner le bouton de “PILOT” à “OFF” à moins qu’il ne soit légèrement enfoncé. Ne le forcez pas.
6. Attendez cinq (5) minutes pour l’evacuation du gaz. Si vous décelez
une odeur de gaz, ARRÊTEZ ! Retournez au point “B” des con­signes de sécurité au verso de cette plaque. Si vous ne remarquez aucune odeur de gaz, passez à l’étape suivante.
7. Enfoncez légèrement le bouton de réglage du gaz et tournez-le en
sens inverse des aiguilles d’une montre jusqu’à la position de veil­leuse “PILOT”.
POUR FERMER LE GAZ QUI ALIMENTE L’APPAREIL
1. Tournez l’interrupteur mural à la position d’arrêt “OFF”. La veilleuse
restera allumée jusqu’au retour du service normal.
2. Pour une fermeture complète, tournez l’interrupteur mural à la posi-
tion d’arrêt “OFF”.
3. Ouvrez le compartiment de contrôle du bas.
REMARQUE : LES SCHÉMAS ET LES ILLUSTRATIONS NE SONT PAS À L’ÉCHELLE
Si la veilleuse refuse de rester al-
lumée après plusieurs tentatives, tournez le bouton de réglage jusqu’à sa position d’arrêt “OFF” et télé­phonez à votre technicien de service ou à votre fournisseur de gaz.
9. Tournez le bouton de réglage du gaz
en sens inverse des aiguilles d’une montre jusqu’à sa position de marche “ON”.
10. Fermez le compartiment de contrôle du bas.
11. Si l’appareil ne fonctionne pas, suivre les instructions intitulées
“Pour fermer le gaz qui alimente l’appareil” et appeler un tech­nicien ou le fournisseur de gaz.
4. Enfoncez légèrement le bouton de réglage du gaz et tournez-le dans
le sens des aiguilles d’une montre jusqu’à la position d’arrêt “OFF”. Ne forcez pas le bouton.
5. Fermez le compartiment de contrôle du bas.
21
Page 22
LENNOX HEARTH PRODUCTS • MERIT® SERIES DIRECT-VENT CONTEMPORARY DESIGN GAS FIREPLACES • MODEL MLDVTCD-35 • CARE AND OPERATION
PILOT
OUT
VENT
LO
TH
TP
TH
TP
HI
IN
IN
OPERATING INSTRUCTIONS — ELECTRONIC
FOR YOUR SAFETY READ BEFORE OPERATING
WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY
RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.
A. This appliance is equipped with an ignition device which
automatically lights the pilot. Do not try to light the pilot by hand.
B. BEFORE OPERATING smell all around the appliance area
for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electric switch; do not use any phone
in your building.
OPERATING INSTRUCTIONS
1. STOP! Read the safety information above on this page.
2. Turn remote wall switch to “OFF" or set wall thermostat
to lowest setting. If used, remove the batteries from the battery holder.
3. This appliance is equipped with an ignition device which
automatically lights the pilot. Do not try to light the pilot by hand.
4. Push the unit mounted "ON/OFF" switch to the "OFF" posi-
tion.
Immediately call your gas supplier from a neighbor’s
phone. Follow the gas supplier’s instructions.
If you cannot reach your gas supplier, call the fire depart-
ment.
C. If any portion of this appliance does not operate as the
instructions indicate, do not try to repair it, call a qualified service technician. Do not use tools. Force or attempted repair may result in a fire or explosion.
D. Do not use this appliance if any part has been under
water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.
6. Push the unit mounted "ON/OFF" switch back to the "ON"
position. (The "ON/OFF" switch may include a wall switch if so equipped). Replace the batteries in the battery holder, if used. If the burner does not light or stay lit after several tries, turn the unit mounted "ON/OFF" switch to the "OFF" position and call your service technician or gas supplier. NOTE: Sufficient time must be allowed for air to escape from lines if the unit is being lit for the first time.
7. Turn HI-LO burner control knob to desired setting and
close control door.
8. Set thermostat to desired setting if applicable.
9. If the appliance will not operate, follow the in-
structions "To Turn Off Gas To Appliance" and call your service technician or gas supplier.
TO SHUT OFF
5. Wait five (5) minutes to clear out any gas. Then smell
for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information above (to the left) on this label. If you don’t smell gas, go to the next step.
1. Turn off all electrical power to the appliance (remote wall
switch) or set the thermostat to the lowest setting, if ap­plicable. Or remove batteries, if used.
TO TURN OFF GAS TO APPLIANCE
1. For complete shut-down, turn remote wall switch to “OFF"
or set the thermostat to the lowest setting, if applicable.
3. Turn off all electric power to the appliance and remove
backup batteries if service is to be performed or for extended shutdown.
2. Turn the ON/OFF switch to “OFF”. If step 1 is not applicable.
22
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Page 23
LENNOX HEARTH PRODUCTS • MERIT® SERIES DIRECT-VENT CONTEMPORARY DESIGN GAS FIREPLACES • MODEL MLDVTCD-35 • CARE AND OPERATION
PILOT
OUT
VENT
LO
TH
TP
TH
TP
HI
IN
IN
INSTRUCTIONS D’ALLUMAGE — ELECTRONIC
POUR PLUS DE SÉCURITÉ LIRE AVANT DE METTRE EN MARCHE
AVERTISSEMENT. QUICONQUE NE RESPECTE PAS À LA LETTRE LES INSTRUCTIONS DANS LA PRÉSENTE NOTICE RISQUE DE DÉCLENCHER UN INCENDIE OU UNE EXPLOSION ENTRAÎNANT DES DOMMAGES, DES BLESSURES OU LA MORT.
A. Cet appareil est muni d’un dispositif d’allumage qui allume
automatiquement la veilleuse. Ne tentez pas d’allumer la veil­leuse manuellement.
B. AVANT DE FAIRE FONCTIONNER: reniflez tout autour de
l’appareil pour déceler une odeur de gaz. Reniflez près du plancher, car certains gaz sont plus lourds que l’air et peuvent s’accumuler au niveau du sol.
QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ :
• Ne pas tenter d’allumer d’appareil.
• Ne touchez à aucun interrupteur; ne pas vous servir des téléphones se trouvant dans le bâtiment.
INSTRUCTIONS DE MISE EN MARCHE
1. ARRÊTEZ ! Lisez les instructions de sécurité sur la portion
supérieure (à gauche) de cette étiquette.
2. Tournez l interrupteur mural à distance à la position arrêt (OFF)
ou placez le thermostat à la plus basse température possible, si requis.
3. Cet appareil est muni d’un dispositif d’allumage qui allume
automatiquement la veilleuse. Ne tentez pas d’allumer la veil­leuse manuellement..
4. Tournez la manette de réglage du gaz à la position d’arrêt “OFF”.
Appelez immédiatement votre fournisseur de gaz depuis un
voisin. Suivez les instructions du fournisseur.
Si vous ne pouvez rejoindre le fournisseur, appelez le service
des incendies.
C. Si un élément de cette unité ne fonctionne pas tel que décrit
dans les instructions, n’essayez pas de le réparer, appelez un technicien qualifié. N’utilisez-pas d’outils. Le fait de forcer la manette ou de la réparer peut déclencher une explosion ou un incendie.
D. N’utilisez pas cet appareil s’il a été plongé dans l’eau, même
partiellement. Faites inspecter l’appareil par un technicien qualifié et remplacez toute partie du système de contrôle et toute commande qui ont été plongés dans l’eau.
6. Poussez le commutateur de l unité à la position marche (ON).
Le commutateur de l unité peut aussi être complémenté d un interrupteur mural. si le brûleur ne s allume pas ou ne reste pas allumeé après plusieurs essais, tournez le commutateur de l unité à la position arrêt (OFF) et appelez votre fournisseur de gaz ou votre technicien de service. Note : Si vous allumez l unité pour la premiére fois, vous devrez attendre un certain temps afin que l air puisse s échapper des conduits.
7. Tournez le bouton de commande du brûleu HI-LO à la posi-
tion désirée et fremez la porte.
.
8. Ajustez le thermostat à la température désiré, si requis.
9. Si l appareil ne fonctionne pas, suivez les in-
structions Comment fermer le gaz qui alimente appareil et contactez votre fournisseur de gaz ou technicien de service.
5. Attendre cinq (5) minutes pour laisser échapper tout le gaz.
Reniflez tout autour de l’appareil, y compris près du plancher, pour déceler une odeur de gaz. Si vous sentez une odeur de gaz, ARRÊTEZ ! Passez à l’étape B des instructions de sécurité sur la portion supérieure (à gauche) de cette étiquette. S’il n’y a pas
POUR ÉTEINDRE L’APPAREIL
1. Coupez le courant électrique qui alimente l appareil (interrupteur
mural) ou placez le thermostat à la plus basse température, si requis.
d’odeur de gaz, passez à l’étape suivante.
COMMENT COUPER L’ADMISSION DE GAZ DE L’APPAREIL
1. Pour une fermeture compléte, tournez l'interrupteur mural à la position arrêt (OFF) ou placez le thermostat à la plus basse température.
3. Coupez l'alimentation électrique du foyer et retirez les batteries de sécurité si vous prévoyez faire le service de' appareil ou si vous ne l'utilisez pas à long terme.
2. Tournez le commutateur de l unité à la position arrêt (OFF) si l'étape l n est pas requise.
REMARQUE : LES SCHÉMAS ET LES ILLUSTRATIONS NE SONT PAS À L’ÉCHELLE
23
Page 24
LENNOX HEARTH PRODUCTS • MERIT® SERIES DIRECT-VENT CONTEMPORARY DESIGN GAS FIREPLACES • MODEL MLDVTCD-35 • CARE AND OPERATION
MAINTENANCE SCHEDULE Turn off gas and electrical power to the fireplace and allow it to cool before cleaning or servicing the appliance.
Annually (Before the onset of the Burning Season)
MAINTENANCE TASK ACCOMPLISHING PERSON PROCEDURE
Inspect/Clean Burner and Controls
Check Flame Patterns and Flame Height Qualified Service Technician Refer to Figure 7 (MLDVTCD-35) on Page 14 and verify the
Inspect/Clean Pilot and Burner Qualified Service Technician Refer to Figure 9 (SIT Millivolt) or Figure 10 (Electronic) on Page
Check Vent System Qualified Service Technician Inspect the vent system at the top and at the base (within the
Appliance Checkout Qualified Service Technician Perform the appropriate appliance checkout procedure detailed
Periodically (After the Burning Season)
Qualified Service Technician Inspect valve and ensure it is properly operating. Check piping
for leaks. Vacuum the control compartment and burner area.
flame pattern and height displayed by the appliance conforms to the picture. Ensure flames are steady (not lifting or floating).
15. Remove any surface build-up on pilot and burner assembly. Wipe the pilot nozzles, igniter/flame rod and hood. Ensure the pilot flame engulfs the flame sensor as shown.
firebox) for signs of blockage or obstruction. Look for any signs of dislocation or deterioration of the vent components. Note:
Excessive condensation can cause corrosion of caps, pipe and fittings (excessive condensation can be caused by long lateral runs, too many elbows and/or exterior portions of the system being exposed to cold weather). Also inspect wall straps or plumbers's tape to ensure it is secure and in place.
in this manual.
MAINTENANCE TASK ACCOMPLISHING PERSON PROCEDURE
Clean Firebox Interior Homeowner Carefully remove contemporary media. Vacuum out interior of
the firebox. Clean firebox walls. Replace contemporary media as detailed in this manual.
Check Flame Patterns and Flame Height Homeowner Refer to Figure 7 (MLDVTCD-35) on Page 14 and verify the
flame pattern and height displayed by the appliance conforms to the picture.
Check Vent System Homeowner Inspect the vent system at the top and at the base (within the
firebox) for signs of blockage or obstruction. Look for any signs of dislocation of the vent components.
Clean Front Glass Enclosure Panel Homeowner Clean as necessary following the directions provided in this
manual. DO NOT TOUCH OR ATTEMPT TO CLEAN GLASS
WHILE HOT.
24
Page 25
LENNOX HEARTH PRODUCTS • MERIT® SERIES DIRECT-VENT CONTEMPORARY DESIGN GAS FIREPLACES • MODEL MLDVTCD-35 • CARE AND OPERATION
TROUBLESHOOTING THE MILLIVOLT CONTROL SYSTEM
Note: Before troubleshooting, be sure that the appliance main line gas shut-off valve, the gas control valve and the wall
switch are in the “ON” position.
Important: Valve system troubleshooting should only be accomplished by a qualified service technician.
SYMPTOM POSSIBLE CAUSES CORRECTIVE ACTION
1. Spark igniter will not light pilot after
repeated triggering of igniter button.
WARNING: if the pilot will not light
after 1 minute of attempting, wait for at least 5 minutes for gas to clear before attempting again.
2. Pilot will not stay lit after
carefully following the lighting instructions.
3. Pilot burning, no gas to burner, Valve
knob “ON,” and the (standard) burner OFF/ON switch is “ON." Read impor­tant note below.
IMPORTANT NOTE: If an optional
*remote switch is used for burner operation, the unit-mounted burner OFF/ON switch (if installed) must be in the "OFF" position.
*Optional remote switch kits - wall
switch, wall thermostat or remote control.
4. Frequent pilot/burner outage prob-
lem.
A. Defective igniter (no spark at electrode).
B. Defective or misaligned electrode at pilot
(spark at electrode).
C. Gas supply pressure errant. Check inlet gas pressure. It should be within the limits
D. Pilot orifice plugged. Clean or replace pilot orifice. A. Defective pilot generator
(thermocouple).
A. Wall switch or wires defective. Check wall switch and wires for proper connections.
B. Thermopile may not be generating suf-
ficient millivolts.
C. Plugged burner orifice. Check burner orifice for blockage and remove. D. OFF/ON Switch and *Remote Switch are
in the "ON" position resulting in excessive resistance.
A. Pilot flame may be too low or blowing (high)
causing the pilot/valve safety to drop out.
Check for spark at electrode and pilot; if no spark and electrode wire is properly connected, replace igniter.
Using a match, light pilot. If pilot lights, turn off pilot and trigger the igniter button again. If pilot lights, an improper gas mixture caused the bad lighting and a longer purge period is recommended. If pilot will not light – check gap at electrode and pilot – should be 1/8" to have a strong spark. If gap does not measure 1/8", replace pilot (see Figures 9 or 10 on Page 15).
as marked on the rating plate.
Check pilot flame, it must impinge on thermocouple (see Figures 9 or 10 on Page 15). Clean and/or adjust pilot for maximum flame impingement on thermocouple. Ensure that the connection between the valve and thermocouple are tight and secure.
Jumper wire across terminals at wall switch, if burner comes on, replace defective wall switch. If okay, jumper wires across wall switch wires at valve, if burner comes on, wires are faulty or connections are bad.
Check thermopile with millivolt meter. Take reading at thermopile terminals of gas valve. Should read 325 millivolts minimum with optional wall switch “OFF.” Replace faulty thermopile if reading is below specified minimum.
When turning on the burner using a *remote switch, ensure that the standard OFF/ON switch is in the "OFF" position. If both switches are in the ON position, it may result in excessive resistance (and millivolt drainage) and the burner may not come on.
Clean and/or adjust pilot flame for maximum flame impingement on thermocouple (see Figures 9 or 10 on Page 15).
25
Page 26
LENNOX HEARTH PRODUCTS • MERIT® SERIES DIRECT-VENT CONTEMPORARY DESIGN GAS FIREPLACES • MODEL MLDVTCD-35 • CARE AND OPERATION
TROUBLESHOOTING THE ELECTRONIC IGNITION SYSTEM
Note: Before troubleshooting, be sure that the appliance main line gas shut-off valve, the gas control valve and the wall
switch are in the “ON” position.
Important: Valve system troubleshooting should only be accomplished by a qualified service technician.
SYMPTOM POSSIBLE CAUSES CORRECTIVE ACTION
1. Nothing happens when
ON/OFF switch is turned on (pilot does not spark).
2. The main burner does
not light and the igniter is sparking.
3. The main burner come
"ON" but then go "OFF".
A. Low voltage/or bad lead
wires.
B. Damaged igniter wire.
C. Damaged pilot assembly.
D. Batteries Low
A. No fuel supply.
B. Loose sensor wire.
C. Lose wires to valve.
D. Loose wires to ignition
module.
E. Air in the gas line.
F. Low voltage.
A. Gas supply is turned
"OFF".
B. Loose wire connection on
valve or ignition module.
Check voltage on AC terminals of module an/or batteries. The value should be around 2.7 to 3.2 VAC. Confirm that wire connections are secure.
Check for visible cracked casing, cuts, etc.
Check pilot assembly for visibly broken spark electrode, etc.
Check voltage on D.C. terminal of batteries. The value should be around 3.0V
Ensure that the gas supply is turned on.
Ensure sensor wire connection is secure.
Ensure black, green and orange wires connection is secure to valve.
Ensure black sensor wire (S) and black igniter wire (I) is secure to ignition module.
Purge gas line of air.
Test voltage at AC terminals of module and/or batteries. It should be around
2.7 to 3.2 VAC.
Turned gas supply to "ON".
Check wire connection.
26
4. Glass soot.
C. Flame does not engulf
flame sensor.
D. Obstructed vent system.
A. Improper air shutter
opening.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Check location of sensor.
Check vent system for obstructions.
Check for proper air shutter openings.
Page 27
LENNOX HEARTH PRODUCTS • MERIT® SERIES DIRECT-VENT CONTEMPORARY DESIGN GAS FIREPLACES • MODEL MLDVTCD-35 • CARE AND OPERATION
REPLACEMENT PARTS LIST
Item
Description MLDVTCD-35
No.
1 Hood H7266 1 2 Lower Control Compartment Panel 3 Enclosure, Glass Front (Complete) H7264 1 4 Door Latch Spring H1264 2
5 Burner Assembly H7676 1 6 Orifice, Main Burner - Natural Gas 21L82 1
Orifice, Main Burner - Propane Gas 75L10 1
7 Bag of Contemporary Media (Tumbled River
Stone) Bag of Contemporary Media (Beach Sand) H7538 1 Bag of Contemporary Media (Obsidian Black
Glass) Bag of Contemporary Media (Diamond White
Glass) Bag of Contemporary Media (Deep Sea Blue
Glass) 8 Orifice Holder H7257 1 9 Gas Line Flexible Connector 93L32 1
10 Sub-Floor Front Panel H7747 1 11 Sub-Floor H7677 1
12 Porcelain Panel Kit H7740 1 12A Porcelain Panel, Left 1 12B Porcelain Panel, Right 1 12C Porcelain Panel, Rear 1
Part No. Qty.
H7262
H7536 1
H7537 1
H7578 1
H7579 1
Gas Controls - SIT Millivolt
Item
Description Natural Gas Propane Gas
No.
15 Gas Valve, SIT H6209 1 88J53 1 16 Piezo Igniter 10K86 1 10K86 1
1
17 Pilot Assembly 69L17 1 69L18 1 18 Pilot Generator 60J79 1 60J79 1 19 Thermocouple 74L57 1 74L57 1 20 Pilot Tube 74L56 1 74L56 1 21 Electrode and Cable H6212 1 H6212 1
Part No. Qty. Part No. Qty.
Gas Controls - Dexen Electronic
Item
Description Natural Gas
No.
28 Gas Valve, Dexen H4681 1
29 Pilot Assembly H4673 1 30 Igniter Module H4674 1 31 Battery Holder H4675 1 32 Wire Harness H4676 1 33 Adapter H4677 1
Part No. Qty.
WARNING
Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury.
Contact an Authorized Lennox Hearth Products dealer to obtain any of these parts. Never use substitute materials. Use of non-approved parts can result in poor performance and safety hazards.
AVERTISSEMENT
Risque de dommages ou de blessures si les pièces ne sont pas installées conformément à ces schémas et ou si des pièces autres que celles spécifiquement approuvées avec cet appareil sont utilisées.
27
Page 28
LENNOX HEARTH PRODUCTS • MERIT® SERIES DIRECT-VENT CONTEMPORARY DESIGN GAS FIREPLACES • MODEL MLDVTCD-35 • CARE AND OPERATION
REPLACEMENT PARTS
5
Dexen Valve
Assembly
9
28
SIT Valve Assembly
9
(Ref.)
15
16
29
12A
8
6
17
18
19
12B
6
4
7
11
12
12C
10
31
1
2
30
3
32
33
28
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Page 29
LENNOX HEARTH PRODUCTS • MERIT® SERIES DIRECT-VENT CONTEMPORARY DESIGN GAS FIREPLACES • MODEL MLDVTCD-35 • CARE AND OPERATION
NOTES
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
29
Page 30
LENNOX HEARTH PRODUCTS • MERIT® SERIES DIRECT-VENT CONTEMPORARY DESIGN GAS FIREPLACES • MODEL MLDVTCD-35 • CARE AND OPERATION
Lennox Hearth Products reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products. Consult your local distributor for fireplace code information.
Printed in U.S.A. © 2009/2012 Lennox Hearth Products
P/N 506017-02 Rev. G 02/2012
30
1508 Elm Hill Pike, Suite 108 • Nashville, TN 37210
Loading...