Unplug or disconnect the appliance from the power
supply before replacing filters or UV-C emitter, or when
appliance is not in use.
WARNING:
To reduce the risk of fire or electric shock, do not use
this fan with any solid-state speed control device.
Do not operate any purifier with a damaged cord or
plug, or if the wall socket is loose. If the supply cord is
damaged, it must be replaced by the manufacturer, its
service agent or similarly qualified persons in order to
avoid a hazard.
Do not run cord under carpeting, throw rugs, runners,
or similar coverings. Do not run cord under furniture
or appliances. Arrange cord away from traffic area and
where it will not be tripped over.
WARNING: Skin or eye damage may result from
directly viewing the light produced by the UV-C
emitter in this apparatus. Unintended use of the
appliance or damage to the housing may result in the
escape of dangerous UV-C radiation. UV-C radiation
may, even in little doses, cause harm to the eyes and
skin. Always disconnect power before relamping or
servicing. Replace UV-C emitter with item 2415105,
Manufactured by ACCO Brands.
• Remove all packaging, including the filter bag,
before use.
• Appliances that are obviously damaged must not be
operated.
• This appliance must only be connected to a wall
socket outlet matching the supply plug type and
rating stated on the rating plate.
• Locate air purifier near the outlet wall socket and do
not use extension cords.
• This appliance can be used by children aged from 8
years and above and persons with reduced physical,
sensory or mental capabilities or lack of experience
and knowledge if they have been given supervision
or instruction concerning use of the appliance in a
safe way and understand the hazards involved.
• Children shall not play with, clean, or try to maintain
the appliance.
• Replace the UV-C emitter with the model specified
within this manual.
• Do not attempt to service or repair this product
yourself.
• Only use the purifier with the power cable provided.
• Only clean this machine with a damp cloth, do not
use solvents or bleach.
• Ensure appliance is always placed on firm level
surface before operation.
• Do not block or obstruct the air intake or outlet vents.
• Do not insert fingers or other items into the air intake
or outlet vents.
PureDirect™ Technology
Independent lab testing confirms that two airflow streams are
better than one, moving air effectively and more comfortably
throughout the room.
360° Purification
DuPont
gases/odours from all directions. UV light kills germs
and bacteria that can get trapped in the filter.
Thoughtful Execution
Exceptional functionality wrapped in a contemporary
design that fits any environment.
™
HEPA filter captures pollutants and VOC
54
CONTROL PANEL
PRODUCT OVERVIEW
Power Button
Fan Speed Settings
Select fan speed: 1, 2, or Turbo.
UV Mode
UV bulb within the purifier’s filter chamber is on when
the symbol is white. The symbol will glow red
when it is time to replace the UV bulb.
(See page 13 for replacement instructions)
Filter and UV Indicator Reset
HEPA, Carbon and UV indicators glow red when it is
time for each to be replaced.
When 1 indicator is on, simply hold Reset button for 3
seconds to reset that indicator. When 2+ indicators are
on, tap the Reset button to select the correct indicator
(selected indicator will blink) before holding 3 seconds
to reset that indicator.
(See pages 11-13 for replacement instructions. Follow above Reset
button instructions aer replacing filter.)
Air Purifier
Filter & Ultraviolet Sterilisation
Carbon Prefilter
Easy-carry handle
Simple touch control panel
360° air intake
Filter cover & knob (underneath)
HEPA Filter
UV Sterilisation
76
GETTING STARTED
1. Remove plastic bag from filter
Unscrew the bottom cover and remove the plastic bag from the filter.
2. Re-attach filter
Secure filter on the bottom cover and replace inside the purifier.
3. Set up
Plug-in your air purifier unit and power on.
Place the purifier on a flat surface, free from obstructions:
- where air can flow freely into the purifier from all sides
- avoiding furnishings like bedding and curtains, as well as sources of
heat or moisture
4. Start living with cleaner air!
Select your preferred fan speed and proprietary PureDirect™ technology will
deliver purified air throughout the room!
98
SPECIFICATIONSCARE & MAINTENANCE
Air Inlet
Air changed 2 times per hr
Air Delivery Type
Fan Speed Settings
Purification Levels
Filter Change Indicators
Noise
Dimensions
Weight
Motor Type
Power Requirements
Power Consumption
Warranty
Replacement Filters & UV Bulb
2-in-1 HEPA drum filter
Carbon Prefilter (3-pack)
360°
23 m²
PureDirect
™
1, 2, Turbo
Carbon Prefilter, HEPA, UV
Carbon, HEPA, UV
39 - 65 dB
195 x 195 x 451 mm
3.5 kg
AC motor
220-240v 50/60Hz 0.5A
40 W
2 years
2415104
2415103
Accessing the filter chamber
1. Always power off the purifier by pressing the Power
Button and unplugging the power cord.
2. Gently place the unit on its side on the floor so that
the filter chamber cover and knob are exposed.
3. Turn the knob counter-clockwise and remove the
filter cover and 360° HEPA filter drum (Fig. A).
REPLACING HEPA FILTER
1. The HEPA indicator will glow red when it is time to
change the entire HEPA drum filter.
2. Gently pull the HEPA drum filter away from its place
secured to the filter cover (Fig. B).
3. Secure the replacement HEPA filter onto the filter
cover (Fig. C).
4. Gently replace the filter cover with filter drum into
the filter chamber and onto the threading, and turn
the knob clockwise until the knob and filter chamber
cover are securely tightened (Fig. D).
Fig. A
Fig. B
Fig. C
UV Bulb
2415105
5. Plug-in and power on your purifier, and hold the
Reset button until the red HEPA indicator turns off.
Note: HEPA drum filter (on page 10) will include 2 layers: Carbon
Prefilter and HEPA
Fig. D
1110
REPLACING CARBON PREFILTERREPLACING UV BULB
1. The Carbon indicator will glow red when it is time to replace
the Carbon layer.
2. Gently peel away the used Carbon layer from the fastener
strips (Fig. E).
3. Wrap a new Carbon layer around the filter drum and attach
to the same fastener strips (Fig. F).
4. Once the purifier is powered-on, hold the Reset button until
the red Carbon indicator turns off.
Note: Carbon Prefilter 3-pack (on page 10) will cover 3 Carbon
changes between replacing the entire HEPA drum filter assemly
(on page 11).
Fig. E
Fig. F
1. The indicator will glow red when it is time to
replace the UV bulb.
2. Remove HEPA filter drum (Fig. A), and use a
screwdriver to remove the screw securing the UV
housing (Fig. G).
3. Gently remove the UV housing (Fig. H) and
disconnect the UV bulb from the socket (Fig. I).
Fig. G
Fig. HFig. I
4. Release carriage from the UV bulb (Fig. J).
5. Secure carriage to new UV bulb (on page 10)
(Fig. K) and connect UV bulb into purifier (Fig L).
6. Replace the UV housing and use a screwdriver to
tighten the fastening screw.
7. Once the purifier is powered-on, hold the Reset
button until the indicator turns white.
Fig. J
Fig. KFig. L
1312
FAQ & TROUBLESHOOTINGGUARANTEE
Operation of this machine is guaranteed for two years from date of purchase, subject to normal use.
How oen do I need to change the
filters?
That’s easy! The purifier’s replacement indicators will notify you when it is
time to replace the Carbon or HEPA filters, or the UV bulb.
Plan on replacing the Carbon every 3-4 months, HEPA every 12-15 months,
and UV bulb every 1-3 years.
Within the guarantee period, ACCO Brands Europe will at its own discretion either repair or replace
the defective machine free of charge. Defects due to misuse or use for inappropriate purposes are
not covered under the guarantee. Proof of date of purchase will be required. Repairs or alterations
made by persons not authorized by ACCO Brands Europe will invalidate the guarantee. It is our aim to
ensure that our products perform to the specifications stated. This guarantee does not affect the legal
rights which consumers have under applicable national legislation governing the sale of goods.
Purifier won’t turn on.
Check that the power cord is connected securely to both the wall outlet and
the purifier. Check if there is a power outage in the outlet by trying a nearby
light or device, or by trying a working device in the same outlet.
Check that the HEPA filter is fitted properly into filter chamber.
SUPPORT
Please contact us if you’re still having a problem! (page 15)
Thank you for welcoming TruSens™ into your home. Our customers
are at the heart of what we do, and we strive to design products that fit
your lifestyle. If you have any questions or feedback, please reach out!
Visit our website at www.trusens.com
Email us at service.uk@acco.com
Call us at 0800 279 5102
Ireland: (01) 6038010
M-Th 09:00 - 16:30
F 09:00-16:00
1514
www.trusens.com
ACCO Brands Europe
Oxford House
Aylesbury HP21 8SZ
United Kingdom
www.accobrands.com