Leica 764558, 764555 User Manual

Leica DISTO™ D8
The original laser distance meter
1
2
3
15
14
16
4
5
6
8
10
7
9
11
12
13
6
Leica DISTO™ D8
User Manual
English
Congratulations on the purchase of your Leica DISTO™ D8.
Carefully read the Safety Instructions and the User Manual before using this product.
The person responsible for the instrument must ensure that all users understand these directions and adhere to them.
Contents
Safety Instructions...................................................................... 1
Start-up........................................................................................... 4
Menu functions............................................................................ 6
Operation...................................................................................... 9
Measuring....................................................................................... 9
Functions...................................................................................... 10
Working with BLUETOOTH®.......................................... 15
Appendix...................................................................................... 16
Safety Instructions
Symbols used
The symbols used in the Safety Instructions have the following meanings:
WARNING:
Indicates a potentially hazardous situation or an unintended use
which, if not avoided, will result in death or serious injury.
CAUTION:
Indicates a potentially hazardous situation or an unintended use which, if not avoided, may result in minor injury and/or in appreciable mate­rial, financial and environmental damage.
Important paragraphs which must be adhered to in practice as they
)
enable the product to be used in a technically correct and efficient manner.
Use of the instrument
Permitted use
•Measuring distances
Computing functions, e. g. areas and volumes
Storing measurements (BLUETOOTH®)
Measuring tilts
Prohibited use
Using the instrument without instruction
Using outside the stated limits
Deactivation of safety systems and removal of explanatory and hazard
labels
Opening of the equipment by using tools (screwdrivers, etc.), as far as
not specifically permitted for certain cases
Carrying out modification or conversion of the product
D
GB
F
I
E
P
NL
CN
Leica DISTO™ D8 LCA782205a gb
1
Safety Instructions
Use of accessories from other manufacturers without the express
D
GB
F
I
E
P
NL
CN
approval of Leica Geosystems.
Deliberate or irresponsible behaviour on scaffolding, when using ladders, when measuring near machines which are running, or near parts of machines or installations which are unprotected
Aiming directly into the sun
Deliberate dazzling of third parties; also in the dark
Inadequate safeguards at the surveying site (e.g. when measuring on roads, construction sites, etc.)
Limits of use
See section “Technical Data“.
)
The Leica DISTO™ is designed for use in areas permanently habitable by humans, do not use the product in explosion hazardous areas or in aggres­sive environments.
Areas of responsibility
Responsibilities of the manufacturer of the original equipment Leica Geosystems AG, CH-9435 Heerbrugg (for short Leica Geosystems): Leica Geosystems is responsible for supplying the product, including the
User Manual and original accessories, in a completely safe condition. (addi­tional language versions can be found at: www.disto.com.)
Responsibilities of the manufacturer of non-Leica accessories:
The manufacturers of non-Leica accessories for the Leica DISTO™
)
are responsible for developing, implementing and communicating safety concepts for their products. They are also responsible for the effectiviness of these safety concepts in combination with the Leica Geosystems equip­ment.
Responsibilities of the person in charge of the instrument:
WARNING
The person responsible for the instrument must ensure that the equipment is used in accordance with the instructions. This person is also accountable for the deployment of personnel and for their training and for the safety of the equipment when in use.
The person in charge of the instrument has the following duties:
To understand the safety instructions on the product and the instruc-
tions in the User Manual.
To be familiar with local safety regulations relating to accident preven-
tion.
To inform Leica Geosystems immediately if the equipment becomes
unsafe.
Hazards in use
CAUTION:
Watch out for erroneous distance measurements if the instrument is defective or if it has been dropped or has been misused or modified.
Precautions:
Carry out periodic test measurements. Particularly after the instrument has been subject to abnormal use, and before, during and after important measurements.
Make sure the Leica DISTO™ optics are kept clean and that there is no mechanical damage to the bumpers.
CAUTION:
In using the instrument for distance measurements or for positioning moving objects (e.g. cranes, building equipment, platforms, etc.) unforeseen events may cause erroneous measurements.
Precautions:
Only use this product as a measuring sensor, not as a control device. Your system must be configured and operated in such a way, that in case of an
Safety Instructions
2
Leica DISTO™ D8 LCA782205a gb
erroneous measurement, malfunction of the device or power failure due to installed safety measures (e.g. safety limit switch), it is assured that no damage will occur.
WARNING:
Flat batteries must not be disposed of with household waste. Care for the environment and take them to the collection points provided in accordance with national or local regulations.
The product must not be disposed of with household waste. Dispose of the product appropriately in accordance with the
national regulations in force in your country. Always prevent access to the product by unauthorised
personnel. Product specific treatment and waste management information can be
downloaded from the Leica Geosystems home page at http://www.leica-geosystems.com/treatment or received from your Leica
Geosystems dealer.
Electromagnetic Compatibility (EMC)
The term "electromagnetic compatibility" is taken to mean the capability of the product to function smoothly in an environment where electromagnetic radiation and electrostatic discharges are present, and without causing electromagnetic interference to other equipment.
WARNING:
The Leica DISTO™ conforms to the most stringent requirements of the relevant standards and regulations. Yet, the possibility of it causing inter­ference in other devices cannot be totally excluded.
CAUTION:
Never attempt to repair the product yourself. In case of damage, contact the local dealership.
Use of the product with BLUETOOTH®:
WARNING:
Electromagnetic radiation can cause disturbances in other equipment, in installations (e.g. medical ones such as pacemakers or hearing aids) and in aircraft. It can also affect humans and animals.
Precautions:
Athough this product conforms to the most stringent standards and regu­lations, Leica Geosystem cannot totally exclude the possibility of harm to people and animals.
Do not use the product near petrol stations, chemical plants, in areas
with a potentially explosive atmosphere and where blasting takes place.
Do not use the product near medical equipment.
Do not use the product in airplanes.
Do not use the product near your body for extended periods.
CAUTION:
Never attempt to repair the product yourself. In case of damage, contact the local dealership.
Laser classification
Integrated distancemeter
The Leica DISTO™ produces a visible laser beam which emerges from the front of the instrument.
It is a Class 2 laser product in accordance with:
IEC60825-1 : 2007 "Radiation safety of laser products"
Laser Class 2 products:
Do not stare into the laser beam or direct it towards other people unnecessarily. Eye protection is normally afforded by aversion responses including the blink reflex.
D
GB
F
I
E
P
NL
CN
Leica DISTO™ D8 LCA782205a gb
3
Safety Instructions
D
Laser Radiation
Do not stare into the beam
Laser class 2
acc. IEC 60825-1:2007
Maximum radiant power: <1mW Emitted wavelength: 620-690nm Beam divergence: 0.16 x 0.6 mrad Pulse duration: 1 x 10 -9 s
GB
F
I
E
P
NL
WARNING:
Looking directly into the beam with optical aids (e.g. binoculars,
telescopes) can be hazardous.
Precautions:
Do not look directly into the beam with optical aids.
CAUTION:
Looking into the laser beam may be hazardous to the eyes.
Precautions:
Do not look into the laser beam. Make sure the laser is aimed above or below eye level. (particularly with fixed installations, in machines, etc.)
CN
Labelling
Start-up
Inserting/replacing batteries
See figure {A} 1 Remove battery compartment lid and attach handstrap.
2 Insert batteries, observing correct polarity. 3 Close the battery compartment again. Replace the batteries when the
symbol flashes permanently in the display.
Remove the batteries before any long period of non-use
)
to avoid the danger of corrosion.
We recommend the usage of AA size max. 1,5V lithium batteries
)
or rechargable NiMH batteries. The Leica DISTO™ also works
with Alkaline batteries but the battery lifetime will be reduced.
WARNING:
This Leica DISTO™ was delivered with high quality non-rechargable lithium batteries. Wrong usage of lithium batteries can be hazardous.
Precautions:
Please do not recharge these batteries.
Do not mix lithium batteries with other types of batteries.
Do not use batteries if their casing is damaged.
Position of the product label see last page!
Start-up
Changing the reference point (multifunctional endpiece)
See figure {B} The instrument can be adapted for the following measuring situations:
For measurements from an edge, fold out the positioning bracket until
it first locks in place. See figure {C}.
4
Leica DISTO™ D8 LCA782205a gb
For measurements from a corner, open the positioning bracket until it locks in place, then push the positioning bracket lightly to the right to fold it out fully. See figure {D}.
A built-in sensor automatically detects the orientation of the positioning bracket and adjusts the zero point of the instrument accordingly.
Keypad
See figure {E}: 1 ON / DIST (On/measuring) button
2 Digital pointfinder - button 3 Timer button 4 Plus (+) button 5 Minus (-) button 6 Area / volume button 7 Indirect measurement (Pythagoras) button 8 Trapezium button 9 Functions button 10 Reference button 11 Storage/Memory button 12 Clear/Off button 13 Menu/Equal button 14 Bluetooth button 15 Second function button 16 Indirect measurement with tilt sensor button
Display in normal mode
See drawing {F.1}. The graphics screen of the measurement window is split into different
areas. Top left is the brightest field, which contains the currently selected measuring program. Just to the right appears the program submenu, which shows the measuring programs that can be selected by pressing the same key the required number of times.
The measurement field contains the individual measurements of the measuring program with reference to a series of separate distance measu­rements. Three lines are provided for this. A horizontal line separates the measurement field and the result bar from one another. A red triangle indicates whether the selected measuring program has a detailed display available.
1 Program selection with measurement instructions 2 Program selection submenu 3 Level 4Timer 5 Measurement field 6 Result bar 7 Detailed display 8 Status bar with (Laser ON, Reference plane, Display Long range mode,
Offset, Plus / Minus, Battery status, Bluetooth, 2nd)
D
GB
F
I
E
P
NL
CN
Leica DISTO™ D8 LCA782205a gb
5
Start-up
Loading...
+ 16 hidden pages