Legrand AC1023 User Manual

INSTRUCTION / INSTALLATION SHEET
Intercom / Unity Relay Module (P/N
301Fulling Mill Road, Suite G Middletown, PA 17057 Phone (800) 321-2343 / Fax (717) 702-2546 www.onqlegrand.com
1. Introduction
The Legrand AC1023 Intercom/Unity Relay Module (see Figure 1) provides the relay interface between the SCI Intercom Module (IC5001) or Unity Integration Module (HA6001) and a third party electronic door strike. This relay module supports a remote door release capability as part of an SCI Intercom or Unity system. It supports a 12 VDC door strike and is powered by an appropriate third party AC to DC power supply.
2. Description
Provides one 2.5mm DIN jack (or 2-pin cage connector labeled “POWER”) for connection to a third party 12 VDC AC to DC power adapter.
Provides one 2-pin cage connector (labeled “CTRL”) for connection to the SCI or Unity Integration Module.
Provides one 2-pin cage connector (labeled “OUT”) for connection (up to 2A) to the electronic door strike.
Provides one 4-pin cage connector (labeled “DRY CONTACT”) that supports a Normally Closed (plus Common)
and Normally Open (plus Common) connections for use when a dry contact is used to initiate the door strike (rather than the SCI or Unity system).
3. Installation
Installation of the Legrand AC1023 and related components is best accomplished at multiple times during new construction, at “Rough-in” before the drywall is installed, and at “Trim-out” after the drywall is installed and painted (see Figure 2).
IMPORTANT: Read the manuals that are included with all associated Unity products before installation of any single component. If you are unsure of any of the following installation procedures contact Legrand Technical Support @ 1-800-321-2343 option 1 or contact a Legrand installer.
A. “Rough-in” steps:
1. AC1023: Run a 16/2 cable from the door release location to the enclosure housing the
2. AC1023 (optional): Run a 16/2 cable from the optional Normally Closed or Normally Open contact
B. “Trim-out” steps:
NOTE: Make sure that the 12VDC Power Supply is not connected to the AC1023 Module.
1. Install the AC1023 in the enclosure by first attaching it to a single bay opening in an existing bracket using the four corner plungers.
AC1023)
IS-0504 Rev. B
Figure 1
AC1023.
location to the enclosure housing the AC1023.
©Copyright 2011 by Legrand All Rights Reserved. Page 1 of 2
INSTRUCTION / INSTALLATION SHEET
Intercom / Unity Relay Module (P/N
301Fulling Mill Road, Suite G Middletown, PA 17057 Phone (800) 321-2343 / Fax (717) 702-2546 www.onqlegrand.com
2. Connect the 16/2 cable from the door strike location to the 2-pin cage connector labeled “OUT” on the AC1023 module.
3. Connect the 16/2 cable from the back of the SCI Module or bottom of the Unity Integration Module (“A” connection pins) to the cage connector pins labeled “CTRL” on the AC1023 module.
4. OPTIONAL: If being connected to a dry contact for control, connect the 16/2 cable from the Normally Open or Normally Closed dry contact to the cage connector pins labeled “DRY CONTACT” on the AC1023 module.
5. After all connections have been made, plug the 12VDC power supply cable into the 2.5mm DIN power jack (or connect the cable to the “POWER” cage connector pins on the AC1023 module and plug the power supply into an AC outlet.
NOTE: All AC powered devices in a Unity system should be powered up at the same time (i.e. use a common power strip for the individual AC adapters).
6. Verify door strike functionality.
AC1023)
IS-0504 Rev. B
Figure 2
©Copyright 2011 by Legrand All Rights Reserved. Page 2 of 2
Figure 2