L.B. White 115 User Manual

All Models are
available in
either Propane
Vapor Withdrawal
or Natural Gas
Configurations.
Congratulations!
You have purchased the finest heater available.
We, at L.B. White, thank you for your confidence in our products and welcome any suggestions or comments you may have...call us, toll-free, at 1-800-345-7200.
Owner's Manual and Instructions
Certification by:
ATTENTION ALL USERS
This heater* has been tested and evaluated by C.S.A. International in accordance with Standard ANSI Z83.7zCSA 2.14 and is listed and approved as a direct gas-fired circulating construction heater with intended use for primarily the temporary heating of buildings under construction, alteration, or repair. As an alternative use, this heater has also been tested and evaluated by the L.B. White Co., Inc. for the heating of agricultural animal confinement buildings and has been used in such applications for many years. If you are considering using this product for any applications other than those previously stated, then please contact your fuel gas supplier or the L.B. White Co., Inc.
150-23259-A
MODELS OUTPUT (Btuh) FUEL
377, 379* 115,000
* The --3 and --4 versions of these heaters are not listed
and approved heaters.
WARNING
Fire and Explosion Hazard
Not for home or recreational vehicle use.
Installation of this heater in a home or
recreational vehicle may result in a fire or explosion.
Fire or explosions can cause property
damage or loss of life.
FOR YOUR SAFETY
If you smell gas:
1. Open windows.
2. Don't touch electrical switches.
3. Extinguish any open flame.
4. Immediately call your gas supplier.
FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
WARNING
Fire and Explosion Hazard
Keep solid combustibles a safe distance
away from the heater.
Solid combustibles include wood or paper
products, feathers, straw, and dust.
Do not use the heater in spaces which
contain or may contain volatile or airborne combustibles.
Volatile or airborne combustibles include
gasoline, solvents, paint thinner, dust particles or unknown chemicals.
Failure to follow these instructions may
result in a fire or explosion.
Fire or explosions can lead to property
damage, personal injury or loss of life.
GENERAL HAZARD WARNING
Failure to comply with the precautions and instructions provided with this heater, can result
in: — Death — Serious bodily injury or burns — Property damage or loss from fire or explosion — Asphyxiation due to lack of adequate air supply or carbon monoxide poisoning — Electrical shock
Read this Owner’s Manual before installing or using this product.
Only properly-trained service people should repair or install this heater.
Save this Owner’s Manual for future use and reference.
Owner’s Manuals and replacement labels are available at no charge. For assistance, contact
L.B. White at 800-345-7200.
WARNING
Proper gas supply pressure must be provided to the inlet of the heater.
Refer to rating plate for proper gas supply pressure.
Gas pressure in excess of the maximum inlet pressure specified at the heater inlet can cause
fires or explosions.
Fires or explosions can lead to serious injury, death, building damage or loss of livestock.
Gas pressure below the minimum inlet pressure specified at the heater inlet may cause
improper combustion.
Improper combustion can lead to asphyxiation or carbon monoxide poisoning and therefore
serious injury or death to humans and livestock.
2
This Owner’s Manual includes all options and accessories commonly used on this heater. However, depending on the configuration purchased, some options and accessories may not be included.
When calling for technical service assistance, or for other specific information, always have model number and serial number available. This information is contained on the dataplate.
This manual will instruct you in the operation and care of your unit. Have your qualified installer review this manual with you so that you fully understand the heater and how it functions.
The gas supply line installation, installation of the heater, and repair and servicing of the heater requires continuing expert training and knowledge of gas heaters and should not be attempted by anyone who is not so qualified. See page 6 for definition of the necessary qualifications. A detailed Installation and Service Guide is available, at no charge, to qualified personnel by contacting the local L.B. White distributor, dealer or the L.B. White Company.
Contact your local L.B. White distributor or the L.B. White Co., Inc. for assistance, or if you have any questions about the use of the equipment or its application.
The L.B. White Co., Inc. has a policy of continuous product improvement. It reserves the right to change specifications and design without notice.
SECTION
PAGE
General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Heater Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Installation Instructions
General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Air Diverter Installation Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Hanging Installation Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Sediment Trap Assembly Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Thermostat Installation Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Start-Up Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Shut-Down Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Cleaning Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
Maintenance Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
Electrical Connection and Ladder Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
Heater Component Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
Parts Identification
Parts Schematic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
Parts List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
Warranty Policy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
Replacement Parts and Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
Table of Contents

General Information

3
SPECIFICATIONS
Maximum Input (BTUH) 115,000
480 CFM
11 in. 7 in.
W.C. W.C.
10 in. 4 in.
W.C. W.C.
5.32 115 lbs. cu. ft.
1/5 H.P.
1100 RPM
6.0
1.6
23
x 16 1/2 x 24
TOP 6 in. SIDES 6 in. BACK 6 in. BLOWER
OUTLET
GAS Propane Gas Supply — 6 ft. (1.83 m) SUPPLY Natural Gas Supply — N/A
90
100
Minimum Ambient Temperature In Which Heater May be Operated
377 379
Propane Natural
Gas Gas
MMooddeell
Ventilation Air Required to Support Combustion
Burner Manifold Pressure
Net Weight (lbs.) Shipping Weight (lbs.)
Electrical Supply (Volts/Hz/Phase)
Amp Draw (Starting Amps Includes Igniter)
Dimensions (Inches) L x W x H
Minimum Safe Distances From Nearest Combustible Materials
STARTING
CONTINUOUS OPERATION
Motor Characteristics
Fuel Consumption Per Hour
Inlet Gas Supply Pressure Acceptable at the Inlet of the Heater for Purpose of Input Adjustment
MAX.
MIN.
MAX.
13.5 in. W.C.
Ball Bearing
6 ft.
-20º F.
115/60/1
4

Heater Specifications

ATTENTION -- CRITICAL POINTS TO REMEMBER!
Propane gas and natural gas have a distinctive odor.
Learn to recognize these odors. (Reference “Fuel Gas Odor” and “Odor Fading” sections above.
If you have not been properly trained in repair and service of propane gas and natural gas fueled heaters, then do not attempt to light heater, perform service or repairs, or make any adjustments to the heater on propane gas or natural gas fuel system.
Even if you are not properly trained in the service and
repair of the heater, ALWAYS be consciously aware of the odors of propane gas and natural gas.
A periodic “sniff test” around the heater or at the
heater’s joints; i.e. hose, connections, etc., is a good safety practice under any conditions. If you smell even a small amount of gas, CONTACT YOUR FUEL GAS SUPPLIER IMMEDIATELY. DO NOT WAIT!
Propane ggas aand nnatural ggas hhave mman-mmade oodorants aadded sspecifically ffor ddetection oof ffuel ggas lleaks.
If aa ggas lleak ooccurs, yyou sshould bbe aable tto ssmell tthe ffuel ggas.
THAT’S YYOUR SSIGNAL TTO GGO IINTO IIMMEDIATE AACTION!
Do not take any action that could ignite the fuel gas. Do
not operate any electrical switches. Do not pull any power supply or extension cords. Do not light matches or any other source of flame. Do not use your telephone.
Get everyone out of the building and away from the area
immediately.
Close all propane gas tank or cylinder fuel supply valves,
or the main fuel supply valve located at the meter if you use natural gas.
Propane gas is heavier than air and may settle in low
areas. When you have reason to suspect a propane leak, keep out of all low areas.
Natural gas is lighter than air and can collect around
rafters or ceilings.
Use your neighbor’s phone and call your fuel gas
supplier and your fire department. Do not re-enter the building or area.
Stay out of the building and away from the area until
declared safe by the firefighters and your fuel gas
supplier.
FINALLY,
let the fuel gas service person and the firefighters check for escaped gas. Have them air out the building and area before you return. Properly trained service people must repair the leak, check for further leakages, and then relight the appliance for you.
WARNING
Do not use this heater for heating human living quarters.
Do not use in unventilated areas.
The flow of combustion and ventilation air must not be
obstructed.
Proper ventilation air must be provided to support the
combustion air requirements of the heater being used.
Refer to the specification section of the heater’s Owner’s
Manual, heater dataplate, or contact the L.B. White
Company to determine combustion air ventilation requirements of the heater.
Lack of proper ventilation air will lead to improper
combustion.
Improper combustion can lead to carbon monoxide
poisoning in humans leading to serious injury or death. Symptoms of carbon monoxide poisoning can include headaches, dizziness and difficulty in breathing.
Symptoms of improper combustion affecting livestock
can be disease, lower feed conversion, or death.
Asphyxiation HHazard
Some ppeople ccannot ssmell wwell. SSome ppeople ccannot smell tthe oodor oof tthe mman-mmade cchemical aadded tto propane oor nnatural ggas. YYou mmust ddetermine iif yyou ccan smell tthe oodorant iin tthese ffuel ggases.
Learn to recognize the odor of propane gas and natural
gas. Local propane gas dealers and your local natural gas supplier (utility) will be more than happy to give you a “scratch and sniff” pamphlet. Use it to become familiar with the fuel gas odor.
Smoking can decrease your ability to smell. Being
around an odor for a period of time can affect your sensitivity to that particular odor. Odors present in animal confinement buildings can mask fuel gas odor.
The oodorant iin ppropane ggas aand nnatural ggas iis ccolorless and tthe iintensity oof iits oodor ccan ffade uunder ssome circumstances.
If there is an underground leak, the movement of gas
through the soil can filter the odorant.
Propane gas odor may differ in intensity at different
levels. Since propane gas is heavier than air, there may be more odor at lower levels.
Always bbe ssensitive tto tthe sslightest ggas oodor.
If you continue to detect any gas odor, no matter how small, treat it as a serious leak. Immediately go into action as discussed previously.
5

Safety Precautions

FUEL GAS ODOR
ODOR FADING -- NO ODOR DETECTED
Loading...
+ 11 hidden pages