DPM 959B 3½ Digit LED Module
A compact meter ideally suited to applications where excellent readability under all lighting conditions is required. The
meter is fitted with high efficiency LEDs which, together with the integral red filter, give a high contrast display with 19mm
digit height. The meter can be easily scaled by the user to indicate volts, amps orotherengineeringunitsandmaybeusedin
single-ended, differential, ratio-metric or floatinginputmodes.
19mm (0.75“) Digit Height
Programmable Decimal Points
Auto-zero
Auto-polarity
200mV d.c. Full Scale Reading (F.S.R.)
SCALING
Two resistors Ra and Rb may be fitted in order to
alter the full scale reading (F.S.R.) of the meter - see
table. The meter will need re-calibration by
adjusting thecalibrationpotentiometer.
Required F.S.R. Ra Rb
2V Note
20V Note 1M 10k
200V Note 1M 1k
2kV Note
200 A LINK 1k
m
2mA LINK 100R
20mA LINK 10R
200mA LINK 1R
NOTE
Ensure thatsolderlink 10acrossRa is OPEN.
910k 100k
1M 100R
Standard Meter DPM 959B
Specification Min. Typ. Max. Unit
Accuracy (overall error) * 0.1 % (±1 count)
Linearity ±1 count
Sample rate 2.5 samples/sec
Operating temperature range 0 50 °C
Warm-up time 10 minute
Temperature s 150 ppm/°C
Supply 4.75 5 5.25 V
Supply 50 90 mA
Input leakage current (Vin = 0V) 1 10 pA
tability
voltage (V+ to V-)
current
* To ensure maximum accuracy, re-calibrate periodically.
SAFETY
To comply with the Low Voltage Directive (LVD 93/68/EEC), input voltages to the module’s pins must not exceed 60Vdc. If
voltages to the measuring inputs do exceed 60Vdc, then fit scaling resistors externally to the module. The user must ensure
that the incorporation of the DPM into the user ’s equipment conforms to the relevant sections of BS EN 61010 (Safety
Requirements for ElectricalEquipmentforMeasuring, Control andLaboratory Use).
Stock Number
DIMENSIONS All dimensions in mm (inches)
40.5 (1.59)
44.0 (1.73)
39.0 (1.54)
24.2 (0.95)
76.0 (2.99)
72.5 (2.85)
51.0 (2.01)
Display in Test Mode
61.5 (2.42)
51.0 (2.01)
71.5 (2.81)
24.0 (0.94)
Ø5.7
(0.22)
24.5 (0.96)
Ø3.0
(0.12)
Panel cut-out 72 x 40 (2.83 x 1.57)
Maximum panel thickness 3mm (0.12).
www.lascarelectronics.com
a
b
d
c
a. 1.0 (0.04)
b. 2.0 (0.08)
c. 6.5 (0.26)
d. 11.5 (0.45)
e. 9.5 (0.37)
e
REAR
VIEW
REAR
VIEW
1
11
POL
SCALING RESISTORS
ON TOPSIDE OF BOARD
ON-BOARD SOLDER LINKS
DE
DP2
DP3
2.54 pin pitch
2
7
16
DP COM
DP1
3
REF LO
VNEG
+SEG
IN LO
COM
GND
REF HI
POL
NC
IN HI
TEST
V+
10
Rb
1
DP1
2.54 pin pitch
21.5
12
Ra
DP3
DP2
LASCAR ELECTRONICS LTD.
MODULE HOUSE
WHITEPARISH WILTSHIRE SP5 2SJ
UK
TEL: +44 (1794) 884567
FAX: +44 (1794) 884616
E-mail: sales@lascar.co.uk
LASCAR ELECTRONICS INC.
3750 WEST 26th STREET
ERIE PA 16506
USA
TEL: +1 (814) 835 0621
FAX: +1 (814) 838 8141
E-mail: us-sales@lascarelectronics.com
PIN FUNCTIONS
1. +SEG Use to indicatepositive polarity-see "VARIOUS OPERATINGMODES" for details.
2. POL To completely disablethe negative polaritysign, cutsolder linkPOL.
3. GND Negative power supplyconnection (0V).
4. V+ Positivepower supplyconnection (+5V).
5. V NEG Output from negativerail generator(-5V nom).This is aninversion ofV+.
6. TEST When taken toV+ all segments,exceptdecimal points, shouldlight i.e. "-1888".
7. IN LO Negative measuring input. Analogueinputs must beno closer than1.5V tothe positiveor negative supply.
8. IN HI Positive measuring input. The negative supply is generated internally and mirrors the positive supply voltage.
9. COM Ground foranalogue section ofthe A/Dconverter,it is activelyheld at 3.05Vbelow V+and mustnot be allowedto sink
excessivecurrent (>100 A)by,for instance, connectingto a highervoltage.
m
10. NC Do not connect.
11. REF LO Negative input forreference voltage. (Connected viaLink 3to COM.)
12. REF HI Positiveinput forreference voltage. (Connected via Link1 tointernal reference.)
13. DP COM Connectto Pins14, 15 or16 toilluminate therequired decimal point,alternatively usethe on-board solderlinks DP1,2 or3.
14. DP1 Connect to Pin13 todisplay DP1 (199.9).
15. DP2
16. DP3
Connect to Pin13 todisplay DP2(19.99).
Connect to Pin13 todisplay DP3(1.999).
SOLDER LINKS
1. Normally closed. Open this linkto disablethe internalreference. Then applyan externalreference to REFHI (pin12).
2. Normally open. Close thislink to connectIN LO (pin7) toCOM (pin9).
3. Normally closed. Open this linkto disconnectCOM (pin9) from REFLO (pin11).
7. Normally open. Close thislink connect INLO (pin 7)to GND(pin 3).
10. Normally closed. Openthis link whenfitting scaling resistorRa.
DP1-2-3. Normally open. Close one ofthese linksto display decimalpoints DP1(199.9), DP2(19.99) orDP3 (1.999) respectively.
POL. Normally closed. Openthis linkto disablethe polaritysign. See Pin Functions 1and 2above.
VARIOUS OPERATING MODES
ON-BOARD SOLDER LINKS: In order to quickly and easily change operating
modes for different applications the meter has several on-board solder links.
They are designedto beeasily opened(cut) or shorted(soldered). Do notconnect
more than one meter to the same power supply if the meters cannot use thesame
signal ground. Taking any input beyond the power supply rails will damage the
meter.
+4.75 to +5.25V +4.75 to +5.25V +4.75 to +5.25V
4
V+
INPUT
VOLTAGE
+
Check solder link 2 is OPEN.
8
IN HI
7
-
IN LO
GND
3
0V 0V
Operation with input referenced to panel
meter supply (Single ended mode).
Preferably link IN LO to GND at signal
source (to reduce loop noise), otherwise
make link 7.
4
V+
8
IN HI
R
7
0.2
R=
FSR
I
Check solder links 2 & 3 are SHORTED.
IN LO
GND
3
Measuring current.
Supply MUST be isolated.
Measuring 4-20mA to read 0-999
(supply MUST be isolated).
Measuring the ratio of two voltages.
Reading = 1000 V /V
50mV< V <200mV
V <2V .
IIN
220k
6R2
Set
5k
Zero
I
OUT
+4.75 to +5.25V+4.75 to +5.25V
+
V
1
-
+
V
2
-
Check solder links 1 & 3 are OPEN.
2
12
8
7
9
8
7
12
11
12
IN HI
IN LO
COM
GND
IN HI
IN LO
REF HI
REF LO
GND
V+
V+
4
3
4
3
0V0V
+4.75 to +5.25V
(Pin 4)
POL
(Pin 2)
0V
(Pin 3)
V+
GND
4
3
Normally
OPEN
Solder to
SHORT
0V
Normally
SHORTED
Cut to
OPEN
Input
Voltage
Check solder link 2 is SHORTED.Check solder link 2 is OPEN.
+
8
IN HI
7
-
IN LO
Operation with input floating
with respect to power supply.
(Pin 1)
1K0
BC307
BC307
10K
1K5
10K
The above circuit can be used to
indicate both positive and negative
polarity, by illuminating either the
+ or - segment on the meter.
+SEG
Specifications liable to change without prior warning DPM 959B Issue 8 October/2003 M.C. Applies to DPM 959B/1