DPM 2000 3½ Digit LCD Module
The DPM 2000 uses advanced components and construction techniques to provide an unrivalled combination of high performance, elegant appearance and low cost. The module uses a bandgap reference for extra temperature stability. For single rail operation, the DPM 2000S featuresabuilt-innegativerail generator,enabling themeter to measurea signal referenced toits ownpower supply 0V.
15mm (0.6“) Digit Height
Programmable Decimal Points
Auto-zero
Auto-polarity
200mV d.c. Full Scale Reading (F.S.R.)
Single Rail Version
SCALING
Two resistors Ra and Rb may be fitted in order to alter the full scale reading (F.S.R) of the meter - see table. The meter will need re-calibration.
Required F.S.R. Ra Rb
2V Note 910k 100k 20V Note 1M 10k 200V Note 1M 1k 2kV Note 1M 100R 200 A link 1k
µ
2mA link 100R 20mA link 10R 200mA link 1R
NOTE
Ensure that link 10 is open if fitting Ra.
Standard Meter DPM 2000 Single Rail Version DPM 2000S
Specification Min. Typ. Max. Unit
Accuracy (overall error) * 0.05 0.1 % (±1 count) Linearity ±1 count Sample rate 3 samples/sec Operating temperature range 0 50 °C Temperature s 30 ppm/°C Supply DPM 2000 7.5 9 14 (V+ to V-) DPM 2000S 3.5 5 6.5 Supply current DPM 2000 150
Input leakage current (Vin = 0V) 1 10 pA
* To ensure maximum accuracy, re-calibrate periodically.
tability
voltage
DPM 2000S 500
Stock Number
V
A
µ
SAFETY
To comply with the Low Voltage Directive (LVD 93/68/EEC), input voltages to the module’s pins must not exceed 60Vdc. If voltages to the measuring inputs do exceed 60Vdc, then fit scaling resistors externally to the module. The user must ensure that the incorporation of the DPM into the user’s equipment conforms tothe relevantsections ofBS EN61010 (Safety Requirementsfor Electrical Equipmentfor Measuring, Controland LaboratoryUse).
DIMENSIONS All dimensions in mm (inches)
32.5 (1.28)
36.0 (1.42)
27.5 (1.08)
72.0 (2.83)
Display in TEST mode
67.5 (2.66)
60.0 (2.36)
53.0 (2.09)
62.5 (2.46)
Ø2.50
(0.10)
19.0 (0.75)
29.5 (1.16)
ab
cd e
29.5 (1.16)
8
+
LMP
TEST
9
H5
12
13
fg
­pH
XB3
XDP
6
11 4 2 7
14
Rb Ra
g
µ
V
%
°F
°C
-5V
CLK
XG3V+RBG
REF-
A
m
M
REF+E3BPABPOL
K
DP1
REF HI
3
1
5
10
:
-
~
DP2
DP3
L
H
REF LO
COM
V-II
ON BOARD SOLDER LINKS
SCALING RESISTORS
a. 1.00 (0.04) b. 9.00 (0.35) c. 1.25 (0.05) d. 5.50 (0.22) e. 4.00 (0.16)
f. 0.50 (0.02)
g. 2.54 (0.10)
LASCAR ELECTRONICS LTD.
MODULE HOUSE, WHITEPARISH,
TEL: +44 (0)1794 884567 FAX: +44 (0)1794 884616
WILTSHIRE SP5 2SJ UK
E-mail: sales@lascar.co.uk
LASCAR ELECTRONICS INC.
3750 West 26th Street,
TEL: +1 (814) 835 0621 FAX: +1 (814) 838 8141
Erie, PA 16506 USA
E-mail: us-sales@lascarelectronics.com
LASCAR ELECTRONICS (HK) LIMITED
FLAT C, 5/FL., LUCKY FTY. bldg., 63-65 HUNG TO ROAD
KWUN TONG, KOWLOON, HONG KONG
TEL: +852 2797 3219 FAX: +852 2343 6187
E-mail: b4lascar@samsongroup.com.hk
PIN FUNCTIONS
1. V- Negative power supply connection.
2. IH Positivemeasuringinput. Analogue inputs mustbe nocloser than1V toeither the positiveor negativesupply. The negative
3. IL Negativemeasuring input. supply of anS-type meteris generatedinternally and mirrorsthe positivesupply voltage.
4. COM The ground forthe analoguesection ofthe A/Dconverter, heldactively at2.8V (nom.)below V+. COM mustnot beallowed tosink
5. REF LO Negative inputforreference voltage.
excessivecurrent (>100 A) byconnecting it directly toa higher voltage.
6. REF HI Positiveinput forreference voltage(connected via Link 1to REF+).
7. POL Drivefor negative(-) annunciator. Internally connectedvia Link 11 tothe annunciator.
8, 10, 15,19 Outputs for autorangingapplications.
9. BP LCD backplane drive waveform.
11. REF+ Positiveoutput frominternal reference (connectedvia Link1 toREFHI).
12. REF- Negative output frominternal reference. MUST betied to a suitableground return tobias bandgap(normally COM).
13. R BG Ouput of bandgapreference (1.22Vnom).
14. V+ Positive power supplyconnection.
16. CLOCK Clock output. Maybe usedfor systemstiming oras an inputto overridethe internal oscillatorand control the samplerate.
17. -5V Outputfrom negativerail generatorcircuit (DPM 2000Sonly). This isaninversion of V+.
18. XDP Connectto requiredannunciators/DPs(see Special Note- Annunciators).
20. TEST Connect to V+to momentarilyturn on segments asillustrated. It should notbe operatedfor morethan a few secondsas the D.C. voltage applied tothe LCDmay 'burn'the display. This pinis 5V (nom)below V+and istheground for thedigital sectionof the meter. It can beused topower externallogicup to amaximumof 1mA.
µ
SPECIAL NOTE - ANNUNCIATORS.
The DPM annunciators (DPs, °C, etc.) can be displayed either by connecting to XDP or by applying a solder blob link to the XDP pads located under the annunciator input
pads. However, as these annunciators are normally 'floating', under certain conditions
they may appear when not wanted. To suppress unwanted annunciators, apply a
solder blob to the backplane pads located in-between the annunciator input pads. If the annunciators are being switched, connect them via M resistor to the BP
(Pin 9), the annunciators will then operate normally when connected to XDP. Ensure
that an annunciator is not connected directly to the XDP and BP at the same time. Note - if suppressing POL (-) annunciator by direct connection to BP then Link 11 MUST be cut first.
VARIOUS OPERATING MODES
ON-BOARD LINKS: In order to quickly and easily change operating modes for different applications, the meter has several on-board links. They are designed to be easily opened (cut) orshorted (soldered). Do notconnect morethan onemeter to the same power supply if the meters cannot use the same signal ground. Taking any input beyond the power supply rails willdamage the meter.
2
±200mV
Check Links 2,3&4areSHORTED.
+
3
-
Measuring a floating voltage source of 200mV full scale.
2
R
3
0.2
R=
I
FSR
Check Links 2,3&4areSHORTED.
Measuring current (supply MUST be isolated).
IN HI
IN LO
IN HI
IN LO
V+
14
V+
V-
1
V-
+
±200mV
Check Links 3 & 4 are SHORTED. Check Links 3 & 4 are SHORTED.
-
0V
1vmin.
2
3
IN HI
IN LO
V+
V-
14
1
Split supply operation (DPM 2000).
V+
14
V+
V-
1
V-
+
V1
-
+
V2
-
Check Link 1 is OPEN.
2
3
6
5
IN HI
IN LO
REF HI
REF LO
14
V+
V-
1
Measuring the ratio of two voltages. Reading = 1000 V /V
50mV < <200mV V<2V
V
12.
12
2
V+
V-
ANNUNCIATOR
XDP
Link either BP or XDP
to annunciator.
V+
14V max. 7V min.
V-
RIGHT
ANNUNCIATOR
BP
XDP
Normally SHORTED Cut to OPEN
+
±200mV
-
Measuring a single ended input referenced to supply (DPM 2000S).
IIN
13
100K
6R2
Check Links 3 & 4 are SHORTED.
Measuring 4-20mA to read 0-999 (supply MUST be isolated).
IOUT
SET
5K
ZERO
WRONG
ANNUNCIATOR
XDP
Do not link BP & XDP
to the annunciator
at the same time
V+
14
V+
2
IN HI
3
IN LO
V-
1
V-
V+
14
V+
2
IN HI
REF BG
3
IN LO
4
COM
V-
1
V-
ANNUNCIATOR
BP
Normally OPEN Solder to SHORT
XDP
Specifications liable to change without prior warning DPM 2000 Issue 4 August/2002 M.C. Applies to DPM 2000/5