Lantronix LMR8TT Installation Manual

LMR8TT
Mini 10BASE-T
Hub/Repeater
1
LMR8TT Ethernet Mini Hub/Repeater Installation Guide
The Lantronix LMR8TT is a 10BASE-T Mini hub that provides wiring connections for up to eight unshielded twisted pair (UTP) ports. An uplink port is provided for cascading two hubs.
The LMR8TT constantly monitors each port for signal quality and will automatically disconnect a device producing noise or excessive collisions. The device will automatically be reconnected when the error condition has cleared.
Data packets that exceed the maximum legal length for IEEE 802.3 Ethernet packets are automatically truncated. This prevents a device from blocking the network by transmitting a continuous data stream or extra long packet. The LMR8TT retimes and restores full amplitude wave forms for each retransmitted packet. A full length preamble is also generated ensuring packet integrity across the network.
Compact, light and robust, the LMR8TT provides the ideal solution for small and medium 10BASE-T LAN environments.
2
Features
The LMR8TT is a cost-effective
unmanaged repeater that allows the interconnection of 10BASE-T segments.
The LMR8TT provides an additional UTP
uplink port to enable LMR8TT hubs to be cascaded together using a standard 'straight' cable.
The LMR8TT accommodates cascaded
bus or daisy-chain topologies. Up to 98 ports can be easily daisy-chained per Ethernet segment
The LMR8TT includes preamble
regeneration, signal retiming and restoration, extension of fragmented packets and jabber function for automatic partitioning.
Power, collision, activity LEDs and
individual port link LEDs aid network diagnosis and management
The LMR8TT complies with IEEE 802.3
10BASE-T twisted pair standards.
The LMR8TT comes with a 5 year
warranty.
3
Cable Requirements
The LMR8TT is for use with standard EIA/TIA category 3, 4,or 5 10BASE-T cable with an RJ45 connector.
Power Requirements
The LMR8TT comes with a 5VAC external power adapter with a frequency range of 47Hz to 63Hz.
Installation
Connecting a 10BASE-T Device
1. Verify that the straight-through cable distance between the LMR8TT and the device is not greater than 100 meters, including all patch cables and cross connect wires.
2. Connect one end of the straight-through cable to the RJ45 connector on the LMR8TT and the other end of the cable to the station.
4
Cascading the LMR8TT
1. A straight-through cable may be used to interconnect two LMR8TTs as long as the cable distance between the two LMR8TT repeaters is not be greater than 100 meters.
2. The LMR8TT may be interconnected as long as the path between any two network stations does not exceed four repeaters and five cable segments. The diagram below demonstrates two cascaded LMR8TTs.
7
654321
X
8
8
765432
1
X
UTP Port Cascade Port
Fig. 1.1 LMR8TTs in cascade configuration.
5
Modular Jack Pinout
Pin Signal Pin Signal 1 TD+ 5 No Connection 2 TD- 6 RD­3 RD+ 7 No Connection 4 No Connection 8 No Connection
LED Explanation
The LMR8TT has 10 LEDs that are visible from the front of the unit. The following chart explains their meanings.
LED Color LED Name Meaning When Lit
Green Power Lit solidly when
LMR8TT is receiving power.
Yellow Collision Lit when a collision
occurs
Green Activity/Link Lit when normal data
packets are received or when link-integrity pulse is detected
Agency Approvals
FCC Class A, TÜV, UL, CSA, CE
Warranty Information
The LMR8TT comes with a limited 5-year warranty. If you experience problems with your unit, check our website (www.lantronix.com) or call Lantronix for assistance.
Copyright 1997, Lantronix. All rights reserved. No part of the contents of this guide may be transmitted or reproduced in any form or by any means without the written permission of Lantronix.
WARNING!
This device complies with part 15 of the FCC rules. Operation is subject to the following conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including that which may cause undesired operation. Operation of this equipment in a residential area is likely to cause interference in which case the user, at his or her own expense, will be required to take whatever measures may be required to correct the interference.
Note: The RJ45 port is not for telephone use.
CAUTION:
Not for installation in air ducts or plenums or other environmental air handling spaces. Changes or modifications to this device not explicitly approved by Lantronix will void the user’s authority to operate this device.
6
Declaration of Conformity
(according to ISO/IEC Guide 22 and EN 45014)
Manufacturer’s Name: Lantronix
Manufacturer’s Address: 15353 Barranca Parkway
Irvine, CA 92618 USA
declares, that the product:
Product Name: Ethernet Repeater Model Number(s): LMR8TT
conforms to the following standards: EMC Directive 89/336/ECC as attested by conformity with the follow-
ing harmonized standards: EN 55022: Class A, 1986: Limits and Methods of Measurement of
Radio Interference characteristics of Information Technology Equipment and
EN 50082/1: 1992: Generic Immunity Standard - Part 1: Domestic Commercial and Light Industry.
Manufacturer’s Contact: Director of Quality Assurance
Lantronix 15353 Barranca Parkway Irvine, CA 92618 USA Tel: 949-453-3990 Fax: 949-453-3995
15353 Barranca
Parkway, Irvine CA 92618
949-453-3990
Fax: 949-453-3995
Direct Sales: 800-422-7055
sales@lantronix.com
International Sales: 949-450-7227
intsales@lantronix.com
Tech Support: 800-422-7044
support@lantronix.com
Part No. 900-124
7
Loading...