Lanner LEC-3034A, LEC-3034B, LEC-3034C, LEC-3034D, LEC-3034E User Manual

Page 1
LEC-3034_user manual
LEC-3034 User Manual
Industrial Communication Platforms
1
Page 2
This manual describes the overview of the various functionalities of this product, and the information you
Example
Convention
Usage
iptables –F
Monospace, shaded
A command to be entered at a shell command-line
Setup page
Bold
A title of a dialog box or a page
<Enter>
Between a pair of inequality signs
A physical keyboard button
“Menu”
Between a pair of quotation marks
A menu option or a software button to be clicked
Readme.txt
In Italic
A filename or a file path
IPMI User Guide
Underlined
The name of another document or a chapter in this document
Icon
Usage
This mark indicates that there is something you should pay special attention to while using the product.
This mark indicates that there is a caution or warning and it is something that could damage your property or product.
Note or Information
Warning or Important
need to get it ready for operation. It is intended for those who are:
- responsible for installing, administering and troubleshooting this system or Information Technology
professionals.
- assumed to be qualified in the servicing of computer equipment, such as professional system
integrators, or service personnel and technicians.
The latest version of this document can be found on Lanner’s official website, available either through the product page or through the Lanner Download Center page with a login account and password.
This document utilizes different font types and icons in order to make selected text more transparent and explicable to users. Please note that this document contains the following conventions:
2
Page 3
LEC-3034_user manual
To obtain additional documentation resources and software updates for your system, please visit the
Lanner Download Center. As certain categories of documents are only available to users who are logged in,
please be registered for a Lanner Account at http://www.lannerinc.com/ to access published
documents and downloadable resources.
For troubleshooting the issues with your system, please check the Lanner Q&A page for a diagnostic procedure and troubleshooting steps.
In addition to contacting your distributor or sales representative, you could use submit a Ticket To Lanner Technical Support page at http://www.lannerinc.com/technical-support where you can fill in a
support ticket to our technical support department.
This document is copyrighted © 2019 by Lanner Electronics Inc. All rights are reserved. The original manufacturer reserves the right to make improvements to the products described in this manual at any time without notice. No part of this manual may be reproduced, copied, translated or transmitted in any form or by any means without the prior written permission of the original manufacturer. Information provided in this manual is intended to be accurate and reliable. However, the original manufacturer assumes no responsibility for its use, nor for any infringements upon the rights of third parties that may result from such use.
Your feedback is valuable to us, as it will help us continue to provide you with more accurate and relevant documentation. To provide any feedback, comments or to report an error, please email to
[email protected], Thank you for your time.
3
Page 4
Corporate
Lanner Electronics Inc. 7F, No.173, Sec.2, Datong Rd. Xizhi District, New Taipei City 221, Taiwan T: +886-2-8692-6060 F: +886-2-8692-6101 E: [email protected]
China
区
层
T: +86 010-82795600 F: +86 010-62963250 E: [email protected]
USA
Lanner Electronics Inc. 47790 Westinghouse Drive Fremont, CA 94539 T: +1-855-852-6637 F: +1-510-979-0689 E: [email protected]
Taiwan
T: +886-2-8692-6060 F: +886-2-8692-6101 E: [email protected]
Canada
LEI Technology Canada Ltd 3160A Orlando Drive Mississauga, ON L4V 1R5 Canada T: +1 877-813-2132 F: +1 905-362-2369 E: [email protected]
Intel® and Intel® Atom are trademarks of Intel Corporation or its subsidiaries in the U.S. and/or other countries. Microsoft Windows and MS-DOS are registered trademarks of Microsoft Corp. All other product names or trademarks are properties of their respective owners.
4
Page 5
LEC-3034_user manual
Note
1. An unshielded-type power cord is required in order to meet FCC emission limits and also to prevent
interference to the nearby radio and television reception. It is essential that only the supplied power cord be
used.
2. Use only shielded cables to connect I/O devices to this equipment.
3. Changes or modifications not expressly approved by the party responsible for compliance could void the
user’s authority to operate the equipment.
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help.
Any changes or modifications not expressly approved by the party responsible for compliance could
void the user's authority to operate this equipment.
This transmitter must not be co-located or operating in conjunction with any other antenna or
transmitter.
Operations in the 5.15-5.25GHz band are restricted to indoor usage only. This device meets all the other requirements specified in Part 15E, Section 15.407 of the FCC Rules.
5
Page 6
Follow these guidelines to ensure general safety:
Keep the chassis area clear and dust-free during and after installation. Do not wear loose clothing or jewelry that could get caught in the chassis. Fasten your tie or scarf and
roll up your sleeves.
Wear safety glasses if you are working under any conditions that might be hazardous to your eyes. Do not perform any action that creates a potential hazard to people or makes the equipment unsafe. Disconnect all power by turning off the power and unplugging the power cord before installing or
removing a chassis or working near power supplies
Do not work alone if potentially hazardous conditions exist. Never assume that power is disconnected from a circuit; always check the circuit.
Suivez ces consignes pour assurer la sécurité générale :
Laissez la zone du châssis propre et sans poussière pendant et après l’installation. Ne portez pas de vêtements amples ou de bijoux qui pourraient être pris dans le châssis. Attachez votre
cravate ou écharpe et remontez vos manches.
Portez des lunettes de sécurité pour protéger vos yeux. N’effectuez aucune action qui pourrait créer un danger pour d’autres ou rendre l’équipement
dangereux.
Coupez complètement l’alimentation en éteignant l’alimentation et en débranchant le cordon
d’alimentation avant d’installer ou de retirer un châssis ou de travailler à proximité de sources d’alimentation.
Ne travaillez pas seul si des conditions dangereuses sont présentes. Ne considérez jamais que l’alimentation est coupée d’un circuit, vérifiez toujours le circuit. Cet appareil
génère, utilise et émet une énergie radiofréquence et, s’il n’est pas installé et utilisé conformément aux
instructions des fournisseurs de composants sans fil, il risque de provoquer des interférences dans les communications radio.
There is a risk of Explosion if Battery is replaced by an incorrect type. Dispose of used batteries according to the instructions. Installation only by a trained electrician or only by an electrically trained person who knows all
Installation and Device Specifications which are to be applied.
Do not carry the handle of power supplies when moving to another place. Please conform to your local laws and regulations regarding safe disposal of lithium BATTERY. Disposal of a battery into fire or a hot oven, or mechanically crushing or cutting of a battery can result in
6
Page 7
LEC-3034_user manual
an explosion.
Leaving a battery in an extremely high temperature surrounding environment can result in an explosion
or the leakage of flammable liquid or gas.
A battery subjected to extremely low air pressure that may result in an explosion or the leakage of
flammable liquid or gas.
Risque d’explosion si la pile est remplacée par une autre d’un mauvais type. Jetez les piles usagées conformément aux instructions. L’installation doit être effectuée par un électricien formé ou une personne formée à l’électricité
connaissant toutes les spécifications d’installation et d’appareil du produit.
Ne transportez pas l’unité en la tenant par le câble d’alimentation lorsque vous déplacez l’appareil.
Electrical equipment generates heat. Ambient air temperature may not be adequate to cool equipment
to acceptable operating temperatures without adequate circulation. Be sure that the room in which you choose to operate your system has adequate air circulation.
Ensure that the chassis cover is secure. The chassis design allows cooling air to circulate effectively. An
open chassis permits air leaks, which may interrupt and redirect the flow of cooling air from internal components.
Electrostatic discharge (ESD) can damage equipment and impair electrical circuitry. ESD damage occurs
when electronic components are improperly handled and can result in complete or intermittent failures. Be sure to follow ESD-prevention procedures when removing and replacing components to avoid these problems.
Wear an ESD-preventive wrist strap, ensuring that it makes good skin contact. If no wrist strap is
available, ground yourself by touching the metal part of the chassis.
Periodically check the resistance value of the antistatic strap, which should be between 1 and 10
megohms (Mohms).
L’équipement électrique génère de la chaleur. La température ambiante peut ne pas être adéquate pour
refroidir l’équipement à une température de fonctionnement acceptable sans circulation adaptée. Vérifiez que votre site propose une circulation d’air adéquate.
Vérifiez que le couvercle du châssis est bien fixé. La conception du châssis permet à l’air de
refroidissement de bien circuler. Un châssis ouvert laisse l’air s’échapper, ce qui peut interrompre et rediriger le flux d’air frais destiné aux composants internes.
Les décharges électrostatiques (ESD) peuvent endommager l’équipement et gêner les circuits
7
Page 8
électriques. Des dégâts d’ESD surviennent lorsque des composants électroniques sont mal manipulés et
peuvent causer des pannes totales ou intermittentes. Suivez les procédures de prévention d’ESD lors du
retrait et du remplacement de composants.
Portez un bracelet anti-ESD et veillez à ce qu’il soit bien au contact de la peau. Si aucun bracelet n’est
disponible, reliez votre corps à la terre en touchant la partie métallique du châssis.
Vérifiez régulièrement la valeur de résistance du bracelet antistatique, qui doit être comprise entre 1 et
10 mégohms (Mohms).
Mounting Installation Precaution
Environment:
Do not install and/or operate this unit in any place that flammable objects are stored or used in. If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack
environment may be greater than room ambient. Therefore, consideration should be given to installing the equipment in an environment compatible with the maximum ambient temperature (Tma) specified by the manufacturer.
Installation of the equipment (especially in a rack) should consider the ventilation of the system’s intake
(for taking chilled air) and exhaust (for emitting hot air) openings so that the amount of air flow required for safe operation of the equipment is not compromised.
To avoid a hazardous load condition, be sure the mechanical loading is even when mounting. Consideration should be given to the connection of the equipment to the supply circuit and the effect
that overloading of the circuits might have on over-current protection and supply wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing this concern.
Reliable earthing should be maintained. Particular attention should be given to supply connections
other than direct connections to the branch circuit (e.g. use of power strips).
Installation & Operation:
The installation of this product must be performed by trained specialists; otherwise, a non-specialist
might create the risk of the system’s falling to the ground or other damages.
Lanner Electronics Inc. shall not be held liable for any losses resulting from insufficient strength for
supporting the system or use of inappropriate installation components.
8
Page 9
LEC-3034_user manual
Before turning on the device, ground the grounding cable of the equipment. Proper grounding (grounding) is very important to protect the equipment against the harmful effects of external noise and to reduce the risk of electrocution in the event of a lightning strike. To uninstall the equipment, disconnect the ground wire after turning off the power. A ground wire is required and the part connecting the conductor must be greater than 4 mm2 or 10 AWG.
Avant d’allumer l’appareil, reliez le câble de mise à la terre de l’équipement à la terre. Une bonne mise à la terre (connexion à la terre) est très importante pour protéger l’équipement contre
les effets néfastes du bruit externe et réduire les risques d’électrocution en cas de foudre.
Pour désinstaller l’équipement, débranchez le câble de mise à la terre après avoir éteint l’appareil. Un câble de mise à la terre est requis et la zone reliant les sections du conducteur doit faire plus de 4
mm2 ou 10 AWG.
Loosen the screw of the earthing point. Connect the grounding cable to the ground. The protection device for the DC power source must provide 30 A
current.
This protection device must be connected to the power source
before DC power.
Desserrez la vis du terminal de mise à la terre. Branchez le câble de mise à la terre à la terre. L’appareil de protection pour la source d’alimentation CC doit
fournir 30 A de courant.
Cet appareil de protection doit être branché à la source
d’alimentation avant l’alimentation CC.
9
Page 10
This equipment must be grounded. The power cord for the product should be connected to a
socket-outlet with earthing connection. Cet équipement doit être mis à la terre. La fiche d'alimentation doit être connectée à une prise de terre correctement câblée
Suitable for installation in Information Technology Rooms in accordance with Article 645 of the National
Electrical Code and NFPA 75. Peut être installé dans des salles de matériel de traitement de l'information conformément à l'article 645 du National Electrical Code et à la NFPA 75.
The machine can only be used in a restricted access location and has installation instructions by a skilled
person (for Fan side). Les matériels sont destinés à être installés dans des EMPLACEMENTS À ACCÈS RESTREINT.
10
Page 11
LEC-3034_user manual
Key Features ............................................................................................................................... 12
Package Content ......................................................................................................................... 12
Ordering Information ................................................................................................................. 12
System Specifications ................................................................................................................. 12
Physical Overview ....................................................................................................................... 14
Motherboard Information .......................................................................................................... 20
Opening the Chassis ................................................................................................................... 28
Installing the Key Components ................................................................................................... 29
Installing the SSD ........................................................................................................................ 31
Main ............................................................................................................................................ 33
Advanced .................................................................................................................................... 34
Security Configuration ................................................................................................................ 46
Chipset ........................................................................................................................................ 47
Security ....................................................................................................................................... 51
Boot Menu .................................................................................................................................. 52
Save and Exit Menu .................................................................................................................... 53
Warranty Policy .......................................................................................................................... 56
RMA Service ................................................................................................................................ 56
RMA Service Request Form ........................................................................................................ 57
11
Page 12
Chapter 1: Product Overview
SKU No.
Main Features
LEC-3034A
DIN rail Fanless Box PC with Intel Atom E3825 processor, 4x RS-232/422/485 COM, 4x GbE LAN ports, 1x USB 2.0 ports, 1xUSB 3.0 port
LEC-3034B
DIN rail Fanless Box PC with Intel Atom E3825 processor, 6x RS-232/422/485 COM, 4x GbE LAN ports, 1 x USB 2.0 ports, 1x USB 3.0 port
LEC-3034C
DIN rail Fanless Box PC with Intel Atom E3825 processor, 8x RS-232/422/485 COM ports, 2x GbE LAN ports, 1x USB 2.0 ports, 1 x USB 3.0 port
LEC-3034D
DIN rail Fanless Box PC with Intel Atom E3825 processor, 4x Isolated RS-485, 2x GbE LAN ports, 3x USB 2.0 ports, 1x USB 3.0 ports
LEC-3034E
DIN rail Fanless Box PC with Intel Atom E3825 processor, 2x GbE LAN ports, 2x Isolated RS-232/485, 8x Isolated RS-485, 3x USB 2.0 ports, 1x USB 3.0 port
Note
If any component is missing or damaged, please contact your dealer immediately for assistance.
Lanner LEC-3034 Series is a wireless rugged fanless edge gateway featuring dual-core Intel® Atom E3825 (codenamed BayTrail), optional 4G-LTE Mobile Connectivity, DDR3L SO-DIMM memory up to 8GB, 1 x SATA
connector with 2.5” drive bay, mSATA mini socket, VGA display, wide operating temperature, DIN
Rail/Wall-mounting options and a variety of isolated protection serial COM/LAN configurations for various industrial IoT needs.
Fanless and compact design Onboard Intel® Atom™ E3825 CPU Optional 4G-LTE Mobile Connectivity Multiple Isolated RS-232/422/485 ports 4x or 2x 1.5KV Magnetic Isolated GbE LAN ports, 2x USB ports Wide operating temperature: -40 ~ 70ºC DIN rail or wall mount VGA output 1x or 3x USB 2.0 type A + 1x USB 3.0 Type A
Your package contains the following items:
1x LEC-3034 1x Accessory Pack 1x Power Adapter
12
Page 13
LEC-3034_user manual
Processor System
Processor Options
Intel® Atom™ Processor E3825 1.33 GHz CPU with Heat-sink fanless thermal solution
Frequency
1.33 GHz
Core Number
2
Chipset
SoC
BIOS
AMI SPI Flash BIOS
Memory
Technology
DDR3L 1067MHz
Max. Capacity
8GB
Socket
1x 204-pin SO-DIMM
Ethernet
Controller
Intel i210-IT
Speed
10/100/1000 Mbps
Interface
2 x RJ45
Isolation Protection
1.5 KV magnetic protection
Hi-Pot test, 1 KV pass Surge, 2KV pass Impulse, 2KV pass
Power
Power Supply Voltage
12 ~ 36 Vdc, Hi-Pot test with adapter,1KV pass
Connector
Phoenix contact 2-pin connector with lock
Power Consumption (Idle)
12V: 7.5W / 36V: 9.2W
Power Consumption(Full Load)
12V: 10.1W / 36V: 11.2W
Power Adaptor
Input 100~240Vac, Output 24V, 2.5A 60W
I/O Interface
Serial Port
4/6/8 x RS-232/422/485 COM(SKU A/B/C), 4x Isolated RS-485 (SKU D), 8x Isolated RS-485 + 2x isolated-232/485 (SKU E)
Isolation Protection
Hi-Pot test, 1 KV pass Surge, 2KV pass Impulse, 2KV pass
ESD Protection
15KV ESD Protection (Contact:8KV, Air:15KV)
USB
1x or 3x USB 2.0 type A + 1x USB 3.0 Type A
Power-On/Reset Button
Internal reset button
LED
PWR,RUN,HDD,L1~2, RX/TX 1~4
Expansion Socket
1x m.2 connector with nano SIM slot
Storage
Type
SATA
Installation
1x SATA connector with 2.5”drive bay
Type
mSATA mini
Installation
1x mSATA mini socket
Watchdog Timer
Watchdog timer 256 level time interval system reset, software programmable
Graphics
Controller
Intel HD Graphics
VGA
1x VGA port
Mechanical
Dimension (W x H x D)
69 x 169.5 x 127 mm
Fanless
Yes
Construction
Aluminum + SGCC
Weight
1.8 kg
Mounting
DIN rail or Wall mount
Environmental
Operating Temperature
-40 ~ 70ºC
Storage Temperature
-40 ~ 80ºC
Relative Humidity
5% ~ 95%, non-condensing
Driver Support
Microsoft Windows
Windows 7
Linux
Linux 2.6
Certification
EMC
CE/FCC Class A
Safety
None
13
Page 14
Chapter 1: Product Overview
F1
F2
F2
F4
F2
F2
F2
F3
F3
F3
F5
F6
F8
F7
F8
F9
F9
14
Page 15
LEC-3034_user manual
No.
Description
F1
LED Indicators
Once powered, this system will then start running automatically with the PWR LED lit up. Wait for several minutes until System Status LED lights up to indicate that your system is up and running.
F2
COM Port
RS-232/422/485 COM Port
F3
COM Port
Isolated RS 485 COM Port
F4
COM Port
Isolated -232/ 485 COM Port
F5
Display Port
D-sub VGA Port
F6
RJ45 Port
10/100/1000Mbps Ethernet port
F7
USB Port
USB 3.0 Port
F8
USB Port
USB 2.0 Port
F9
Antenna Port
To connect antennas
System Status Indicator
COM Transmission Indicator
AUX Main
15
Page 16
Chapter 1: Product Overview
16
Page 17
LEC-3034_user manual
17
Page 18
Chapter 1: Product Overview
18
Page 19
LEC-3034_user manual
No.
Description
S1
Reset Button
Use a pin to reset the system
S2
DC Input
For power supply
S3
Grounding Point
For a proper cable to connect the ground
S3
S2
S1
19
Page 20
Chapter 1: Product Overview
PPWWRR11
CCLLRR11
JJUUSSBB11
SSPPIIRROOMM11
LLPPCC11
JJ33 MM22__1
1
SSIIMM11
MMPPCCIIEE11
((FFoorr mmSSAATTAA))
The motherboard layout shows the connectors and jumpers on the board. Refer to the following picture as a reference of the pin assignments and the internal connectors.
20
Page 21
LEC-3034_user manual
JJ11 JJ33 JJ22
The daughterboard carries SATA port and serial COM ports, the pin definition of which can be found in COM Port Pin-out.
21
Page 22
PWR1: Power Button
Pin No.
Description
1-2 (Default)
RS485 Enable
NC
Jumper
Description
1-2
Power ON/OFF system
NC (Default)
Normal
Jumper
Description
1-2
Clear CMOS
NC (Default)
Normal
CLR1: Clear CMOS
Chapter 1: Product Overview
J3 (Daughterboard):RS485 Switch
22
Page 23
LEC-3034_user manual
Pin
Description
Pin
Description
1
SPI_HOLD_N
2
SPI_CS1_R_N
3
SPI_CS0_R_N
4
V_3P3_SPI_R
5
SPI_MISO_R
6
SPI_HD0_N
7
NC
8
SPI_CLK
9
GND
10
SPI_MOSI_R
Pin
Description
Pin
Description
1
LPC_CLK_1
2
LPC_AD1
3
PLTRST_P80_N
4
LPC_AD0
5
LPC_FRAME_N
6
P3V3
7
LPC_AD3
8
GND
9
LPC_AD2
10
GND
SPIROM1: SPI ROM Connector (For RD debug)
LPC1: LPC Connector (For RD debug)
J3 (Motherboard): Board to Board Connector 2x50P
23
Page 24
Chapter 1: Product Overview
PIN
Description
PIN
Description
PIN
Description
PIN
Description
A1
LAN2_L1000_N_R
A26
GND
B1
COM4_RXD
B26
GND
A2
LAN2_ACTLED_N
A27
SW3_PCIE_TX_DN
B2
COM4_TXD
B27
SWLAN_PCIE_TX_DN
A3
LAN1_L100_N_R
A28
SW3_PCIE_TX_DP
B3
COM4_RTS#
B28
SWLAN_PCIE_TX_DP
A4
LAN1_L1000_N_R
A29
GND
B4
COM4_CTS#
B29
GND
A5
LAN1_ACTLED_N
A30
SW3_PCIE_RX_DN
B5
COM3_RXD
B30
SWLAN_PCIE_RX_DN
A6
LAN1_L100_N_R
A31
SW3_PCIE_RX_DP
B6
COM3_TXD
B31
SWLAN_PCIE_RX_DP
A7
SMB_SOC_CLK_3P3
A32
GND
B7
COM3_RTS#
B32
GND
A8
SMB_SOC_DATA_3P3
A33
CLK_SWCOM_PCIE_DN
B8
COM3_CTS#
B33
CLK_100M_PCIE2_DN
A9
COM5_DSR#
A34
CLK_SWCOM_PCIE_DP
B9
COM2_RXD
B34
CLK_100M_PCIE2_DP
A10
COM5_DTR#
A35
GND
B10
COM2_TXD
B35
GND
A11
COM5_RI#
A36
SWCOM_PCIE_TX_DN
B11
COM2_RTS#
B36
PCIE2_TX_DN
A12
COM5_DCD#
A37
SWCOM_PCIE_TX_DP
B12
COM2_CTS#
B37
PCIE2_TX_DP
A13
COM5_RXD
A38
GND
B13
COM1_RXD
B38
GND
A14
COM5_TXD
A39
SWCOM_PCIE_RX_DN
B14
COM1_TXD
B39
PCIE2_RX_DN
A15
COM5_RTS#
A40
SWCOM_PCIE_RX_DP
B15
COM1_RTS#
B40
PCIE2_RX_DP
A16
COM5_CTS#
A41
GND
B16
COM1_CTS#
B41
GND
A17
GND
A42
P3V3
B17
GND
B42
GND
A18
USB_P1_DN
A43
P3V3
B18
SATA_TX1_DN
B43
GND
A19
USB_P1_DP
A44
NC
B19
SATA_TX1_DP
B44
GND
A20
GND
A45
P5V
B20
GND
B45
GND
A21
USB_P0_DN
A46
P5V
B21
SATA_RX1_DN
B46
PE_RST_OUT_82
A22
USB_P0_DP
A47
P5V
B22
SATA_RX1_DP
B47
NC
A23
GND
A48
NC
B23
GND
B48
NC
A24
CLK_SW3_PCIE_DN
A49
P12V
B24
CLK_SWLAN_PCI
E_DN
B49
NC
A25
CLK_SW3_PCIE_DP
A50
P12V
B25
CLK_SWLAN_PCI
E_DP
B50
NC
M2_1: M.2 NGFF Connector (B Key)
24
Page 25
LEC-3034_user manual
Pin No.
Description
Pin No.
Description
1
NC
2
P3V3SB_M2
3
GND
4
P3V3SB_M2
5
GND
6
PWROFF#
7
USB_P0_DP
8
NC
9
USB_P0_DN
10
NC
11
GND
12
NC
13
NC
14
NC
15
NC
16
NC
17
NC
18
NC
19
NC
20
NC
21
NC
22
NC
23
NC
24
NC
25
NC
26
NC
27
GND
28
NC
29
NC
30
UIM1_RST1
31
NC
32
UIM1_CLK1
33
GND
34
UIM1_DAT1
35
NC
36
UIM1_PWR
37
NC
38
NC
39
GND
40
NC
41
NC
42
NC
43
NC
44
NC
45
GND
46
NC
47
NC
48
NC
49
NC
50
NC
51
GND
52
NC
53
NC
54
NC
55
NC
56
NC
57
GND
58
NC
59
NC
60
NC
61
NC
62
NC
63
NC
64
NC
65
NC
66
NC
67
NC
68
NC
69
NC
70
P3V3SB_M2
71
GND
72
P3V3SB_M2
73
GND
74
P3V3SB_M2
75
NC
25
Page 26
SIM1: Nano SIM Card Reader
Pin
Description
Pin
Description
C1
UIM_PWR
C5
GND
C2
UIM_RST#
C6
NC
C3
UIM_CLK
C7
UIM_DATA
Pin
Description
Pin
Description
1
VCC_USB5
2
GND
3
NC 4 NC
5
USBDN5
6
NC
7
USBDP5
8
NC
9
GND
10
NC
Please insert the SIM card into the socket as shown in the picture. Its golden contacts should face down.
Chapter 1: Product Overview
JUSB1: USB2.0 pin header
26
Page 27
LEC-3034_user manual
Pin No.
Description
Pin No.
Description
1
RSVD
2
VCC3
3
RSVD
4
GND
5
RSVD
6
RSVD
7
RSVD
8
RSVD
9
GND
10
RSVD
11
RSVD
12
RSVD
13
RSVD
14
RSVD
15
GND
16
RSVD
Mechanical Key
17
RSVD
18
GND
19
RSVD
20
RSVD
21
GND
22
RSVD
23
SATA RX+
24
VCC3
25
SATA RX-
26
GND
27
GND
28
RSVD
29
GND
30
RSVD
31
SATA TX-
32
RSVD
33
SATA TX+
34
GND
35
GND
36
RSVD
37
GND
38
RSVD
39
VCC3
40
GND
41
VCC3
42
RSVD
43
GND
44
RSVD
45
RSVD
46
RSVD
47
RSVD
48
RSVD
49
RSVD
50
GND
51
RSVD
52
VCC3
MPCIE1: MSATA Connector (Half Size)
27
Page 28
Chapter 2: Hardware Installation
1. Unscrew the five screws on the
system’s side panels and back panel.
2. Lift the cover to remove it.
To reduce the risk of personal injury, electric shock, or damage to the system, please remove all power connections to shut down the device completely. Also, please wear ESD protection gloves when conducting the steps in this chapter.
28
Page 29
LEC-3034_user manual
1 2 3
DDaauugghhtteerrbbooaarrdd
MMootthheerrbbooaarrdd
In order to install the key components including M.2 card, mSATA card, the Nano SIM card and memory module, please remove (1) the heat sink that secures the daughter board, (2) the screws that secure the
VGA connector on front panel and (3) the screws that secure the daughterboard on the standoffs.
Carefully lift up the daughterboard to have it disconnected from the board-to-board connector (J3).
29
Page 30
Chapter 2: Hardware Installation
mSATA
Memory
M.2
SIM
Install the key parts and make sure you replace the heatsink originally attached to the sockets
30
Page 31
LEC-3034_user manual
BBrraacckkeett
1. Remove the SSD bracket originally attached to the top cover and install the SSD onto it. Make sure you
secure the disk onto the bracket with four disk screws.
2. Fix the bracket with SSD loaded onto the top cover, and connect the SATA cable and SATA power cable
as shown in the picture.
31
Page 32
Chapter 3: BIOS Setup
Control Keys
Description

select a setup screen
select an item/option on a setup screen
<Enter>
select an item/option or enter a sub-menu
+/-
adjust values for the selected setup item/option
F1
display General Help screen
F2
retrieve previous values, such as the last configured parameters during the last time you entered BIOS
F3
load optimized default values
F4
save configurations and exit BIOS
<Esc>
exit the current screen
To enter the BIOS setup utility, follow the steps below:
1. Boot up the system.
2. Pressing the <Tab> or <Del> key immediately allows you to enter the Setup utility, then you will be
directed to the BIOS main screen. The instructions for BIOS navigations are as below:
32
Page 33
LEC-3034_user manual
Item
Description
BIOS Information
BIOS Vendor: American Megatrends Core Version: AMI Kernel version, CRB code base, X64 Compliancy: UEFI version, PI version Project Version: BIOS release version Build Date and Time: MM/DD/YYYY Access Level: Administrator / User
System Date
To set the Date, use <Tab> to switch between Date elements. Default range of Year: 2005-2099 Default range of Month: 1-12 Days: dependent on Month.
System Time
To set the Date, use <Tab> to switch between Date elements.
Setup main page contains BIOS information and project version information.
(The screenshots presented in this section are for reference only)
33
Page 34
Chapter 3: BIOS Setup
Select the Advanced menu item from the BIOS setup screen to enter the “Advanced” setup screen. Users can select any of the items in the left frame of the screen.
34
Page 35
LEC-3034_user manual
This option allows you to configure parameters about Super IO Chip. Press <Enter> to access the submenu.
Select the desired Serial Port Configuration item to enter sub setting screen.
35
Page 36
Serial port 1 Configuration
Item
Option
Description
Serial Port
Enabled
Disabled
Enables or disables Serial Port 1.
Device Settings
NA
IO=3F8h; IRQ = 4
Chapter 3: BIOS Setup
36
Page 37
LEC-3034_user manual
Item
Description
SYS1 Temp
This value reports the CPU temperature.
SYS2 Temp
This value reports the System temperature.
CPU VCORE
This value reports the CPU VCORE.
5V
This value reports the 5V Input voltage.
DCIN
This value reports the DC Input voltage.
VBAT
This value reports the VBAT Input voltage.
3.3V
This value reports the 3.3V Input voltage.
VSB3.3V
This value reports the VSB3.3V Input voltage.
VBAT
This value reports the VBAT Input voltage.
37
Page 38
Chapter 3: BIOS Setup
Item
Description
On Board LAN
Boot
Disabled
LAN1 LAN2
Select On Board LAN # boot
38
Page 39
LEC-3034_user manual
Feature
Options
Description
COM1 Mode
232
485 422
Select Com Mode as
RS-232/485/422
COM1 Termination
Disabled
Enabled
COM RS-485/422 Receiver Termination
COM2 Mode
232
485 422
Select Com Mode as
RS-232/485/422
COM2 Termination
Disabled
Enabled
COM RS-485/422 Receiver Termination
COM3 Mode
232
485 422
Select Com Mode as
RS-232/485/422
COM3 Termination
Disabled
Enable
COM RS-485/422 Receiver Termination
COM4 Mode
232
485 422
Select Com Mode as
RS-232/485/422
39
Page 40
COM4 Termination
Disabled
Enabled
COM RS-485/422 Receiver Termination
COM5 Mode
232
485 422
Select Com Mode as
RS-232/485/422
COM5 Termination
Disabled
Enabled
COM RS-485/422 Receiver Termination
COM6 Mode
232
485 422
Select Com Mode as
RS-232/485/422
COM6 Termination
Disabled
Enabled
COM RS-485/422 Receiver Termination
Chapter 3: BIOS Setup
40
Page 41
LEC-3034_user manual
Item
Description
Limit CPUID
Maximum
Disabled
Enabled
Disable for Windows XP
Execute Disable Bit
Disabled
Enabled
Execute Disable Bit
Intel Virtualization
Technology
Disabled
Enabled
When enabled, a VMM can utilize the additional
hardware capabilities provided by Vanderpool
Technology
41
Page 42
Socket 0 CPU Information
Chapter 3: BIOS Setup
42
Page 43
LEC-3034_user manual
Feature
Options
Description
Serial-ATA (SATA)
Disabled
Enabled
Enable/Disable Serial ATA
SATA Speed Support
Gen1
Gen2
SATA Speed Support Gen1 or Gen2
SATA MODE
IDE Mode
AHCI Mode
Select EDE/AHCI
Serial-ATA Port 0
Disabled
Enabled
Enable/Disable Serial ATA PORT 0
Serial-ATA Port 1
Disabled
Enabled
Enable/Disable Serial ATA PORT 1
43
Page 44
Chapter 3: BIOS Setup
Feature
Options
Description
Legacy USB Support
Enabled
Disabled
Auto
Enables Legacy USB support. Auto option disables legacy support if no USB devices are connected; Disabled option will keep USB devices available only for EFI applications.
XHCI Hand-off
Enabled
Disabled
This is a workaround for OSes without XHCI hand-off support. The XHCI ownership change should be claimed by XHCI driver.
EHCI Hand-off
Enabled
Disabled
This is a workaround for OSes without EHCI hand-off support. The EHCI ownership change should be claimed by EHCI driver
USB Mass Storage
Driver Support
Enabled
Disabled
Enables or disables USB Mass Storage Driver Support.
USB transfer time-out
1 sec
5 sec 10 sec
20 sec
The time-out value for Control, Bulk, and Interrupt transfers
Device reset time-out
1 sec
5 sec
USB mass storage device Start Unit command time-out
44
Page 45
LEC-3034_user manual
10 sec
20 sec
Device power-up delay
Auto
Manual
Maximum time the device will take before it properly reports itself to the Host Controller. Auto uses default value: for a Root port, it is 100 ms, for a Hub port the delay is taken from Hub descriptor.
45
Page 46
Chapter 3: BIOS Setup
Feature
Options
Description
TXE
Enabled
Disabled
Enables TXE function.
TXE HMRFPO
Enabled
Disabled
When user wants to update TXE to set this item to enable, but this item only can active once.
TXE firmware Update
Enabled
Disabled
TXE firmware update
TXE EOP Message
Enabled
Disabled
Send EOP Message Before Enter OS.
INTEL(R) AT
Enable
Disable
Intel Anti-Theft Technology.
INTEL(R) AT platform
PBA
Enable
Disable
Intel Anti-Theft Technology platform PBA function.
46
Page 47
LEC-3034_user manual
Select the Chipset menu item from the BIOS setup screen to enter the “Chipset” setup screen. Users can select any of the items in the left frame of the screen.
47
Page 48
Chapter 3: BIOS Setup
Feature
Options
Description
Max TOLUD
Dynamic
2 GB
2.25 GB
2.5 GB
2.75 GB 3 GB
Maximum Value of TOLUD.
48
Page 49
LEC-3034_user manual
49
Page 50
Chapter 3: BIOS Setup
Feature
Options
Description
XHCI Mode
Enabled
Disabled
Auto
Smart Auto
Mode of operation of xHCI controller.
50
Page 51
LEC-3034_user manual
Feature
Description
Administrator Password
If ONLY the Administrator's password is set, it only limits
access to Setup and is only asked for when entering Setup.
User Password
If ONLY the User's password is set, it serves as a power-on
password and must be entered to boot or enter Setup. In
Setup, the User will have Administrator rights.
Select the Security menu item from the BIOS setup screen to enter the Security Setup screen. Users can select any of the items in the left frame of the screen.
51
Page 52
Chapter 3: BIOS Setup
Feature
Options
Description
Setup Prompt Timeout
1
The number of seconds to wait for setup activation key. 65535 means indefinite waiting.
Quiet Boot
Disabled
Enabled
Enable or disables Quiet Boot option.
Boot mode select
LEGACY
UEFI
DUAL
Select boot mode for LEGACY or UEFI.
Select the Boot menu item from the BIOS setup screen to enter the Boot Setup screen. Users can select any of the items in the left frame of the screen.
Choose boot priority from boot option group. Choose specifies boot device priority sequence from available Group device.
52
Page 53
LEC-3034_user manual
Select the Save and Exit menu item from the BIOS setup screen to enter the Save and Exit Setup screen. Users can select any of the items in the left frame of the screen.
■ Save Changes and Reset When Users have completed the system configuration changes, select this option to save the changes and exit from BIOS Setup in order for the new system configuration parameters to take effect. The following window will appear after selecting the “Save Changes and Exit” option is selected. Select “Yes” to Save Changes and Exit Setup.
■ Discard Changes and Exit
Select this option to quit Setup without saving any modifications to the system configuration. The following window will appear after the “Discard Changes and Exit” option is selected. Select “Yes” to Discard changes and Exit Setup.
Page 54
Note
The items listed under Boot Options will depend on the devices connected to this system.
■ Restore Defaults
Restore default values for all setup options. Select “Yes” to load Optimized defaults.
Chapter 3: BIOS Setup
54
Page 55
LEC-3034_user manual
Product Name Keyword
I210
Download Type
Drivers
Operating System
Linux*
Product page
Downloads for Intel® Ethernet Controller I210 Series
To install the Intel® LAN controller base driver for the Red Hat® and Linux operating system, please visit
http://www.lannerinc.com/support/download-center/drivers, enter the product category and download the
utility package of this system.
For the latest driver update, please visit Intel® download center at https://downloadcenter.intel.com/, use the keyword search or the filter to access the driver’s product page, and then download the latest controller driver as well as the ReadMe document.
55
Page 56
Appendix B: Terms and Conditions
Note
Customer is responsible for shipping damage(s) resulting from inadequate/loose packing of the defective unit(s). All RMA# are valid for 30 days only; RMA goods received after the effective RMA# period will be rejected.
1. All products are under warranty against defects in materials and workmanship for one year
from the date of purchase.
2. The buyer will bear the return freight charges for goods returned for repair within the warranty period;
whereas the manufacturer will bear the after service freight charges for goods returned to the user.
3. The buyer will pay for the repair (for replaced components plus service time) and transportation charges
(both ways) for items after the expiration of the warranty period.
4. If the RMA Service Request Form does not meet the stated requirement as listed on “RMA Service,“ RMA
goods will be returned at customer’s expense.
5. The following conditions are excluded from this warranty:
Improper or inadequate maintenance by the customer Unauthorized modification, misuse, or reversed engineering of the product Operation outside of the environmental specifications for the product.
1. To obtain an RMA number, fill out and fax the “RMA Request Form“ to your supplier.
2. The customer is required to fill out the problem code as listed. If your problem is not among the codes
listed, please write the symptom description in the remarks box.
3. Ship the defective unit(s) on freight prepaid terms. Use the original packing materials when possible.
4. Mark the RMA# clearly on the box.
56
Page 57
LEC-3034_user manual
When requesting RMA service, please fill out the following form. Without this form enclosed, your RMA cannot be processed.
57
Loading...