Lang Manufacturing LG Installation Manual

Lang Griddle
Start-Up
1) Verify connections at plug in outlet are tight.
2) Incoming Volt - Single Phase L1______
3) Gas pressure is set for 4.5" WC (Natural Gas), (9" WC (Propane) Ensure that the regulator is installed in the correct direction.
4) Ensure griddle body is tilted 1/ 8" lower in front. Confirm there is 4" clearance below griddle
Flames must not lift off of burner ports.
6) Ensure spark electrode does not continue to spark . The tip of the spark electrode and sensor electrodes must have flame on them and glowing red.
Model #____________ Date_______ Serial #___________
Store #__________________ Tech Name____________________________
Contact__________________ Company _____________________________
Store Phone #______________ Service Company Phone #________________
Address_____________________
______________________
______________________
Please fax to Lang Manufacturing @ 425-349-2483