Post in a prominent location, a set of instructions to be followed in the event
the user smell gas. Obtain these instructions from your local gas supplier.
FOR YOUR SAFETY: Do not store or use gasoline or other flammable vapors
and liquids in the vicintiy of this or any other gas appliance.
In the event a gas odor is detected, shut down units at the main shut-off valve
and contact the local gas company or supplier for service.
WARNING: Improper installation, adjustment, alteration, service or
maintenance can cause property damage, injury or death. Read the
installation, operating and maintenance intructions thoroughly before installing
or servicing this equipment.
Installation, startup and adjustments of this appliance should be accomplished
by personnel qualified to install gas equipment.
Retain this manual for future reference.
Section A
GENERAL INSTRUCTIONS
1. Preliminary operations
Make sure the appliance is supplied complete and has not been
damaged in transit.
2. Positioning
Keep the appliance area free and clear of combustible material and do not obstruct the flow of
combustion or ventilation air.
The installation of any components such as a vent hood, grease extractors, and/or fire
extinguisher systems, must conform to the their applicable nationally recognized installation
standards.
3. Gas connection
☞
For the exact position and size of connections, consult the gas connection chart
enclosed in Section B.
All gas connections must be in accordance with local codes and comply with the National
Fuel Gas Code ANSI Z223.1 latest edition, Natural Gas Installation Code CAN/CGA - B149.1
or Propane Installation Code CAN/CGA - B149.2.
Connect each oven separately. A gas shut off valve must be installed to the oven(s) and
located in an accessible area.
This appliance and its individual shutoff valve must be disconnected from the gas supply
piping system during any pressure testing of that system at test pressures in excess of 1/2
PSGI (3.45 kPA) and the appliance must be isolated from the gas supply piping system by
closing its individual manual shutoff valve during any pressure testing of the gas supply
system at test pressures equal to or less than 1/2 PSIG (3.45 kPA).
3.1 Test gas
Model
XXX
NAT. - 7" 4.5"
123
Btu/h
Serial number
120V1N 60 Hz A
1) Gas type and supply pressure
2) Injector pressure
3) Input rating Btu/h
☞
gas with wich it is to be operated.
Always check the pressure of the the gas supply. For this purpose, use the pressure test
outlet provided on the appliance, following procedure outlined in section B.
Test for gas leaks. Use a commercial leak detector or a soap and water solution.
Check the data plate to make sure that the appliance has been tested for the type of
WARNING
DO NOT USE AN OPEN FLAME TO TEST FOR GAS LEAKS.
- 1 -
Section A
GENERAL INSTRUCTIONS
4. Electrical connection
The appliace must be electrically grounded in accordance with local codes, or in the absence
of local codes, with the
Code, CSA C22.1
-.2.
National Electrical Code, ANSI/NFPA 70
, or the
Canadian Electrical
4.1 Operating voltage
Model
XXX Serial number
NAT. - 7" 4.5" Btu/h
120V1N 60 Hz A
☞
☞
☞
Check the data plate to make sure the operating voltage and frequency of the
appliance correspond to those of mains supply.
Adhere scrupulously to the indications in the technical chart and in the wiring diagram,
and the instructions contained in section B.
In the notes for the customer service is indicated the location of the wiring diagram on
the appliance.
Check the current absorption indicated on the data plate to determine the crosssectional area of the supply cable.
XXXXXXXXXX 0000
208V3
~ A Hz kW
0000000000000000000
5. Water connection
This appliance is to be installed to comply with the applicable Federal, state, or local
plumbing codes having jurisdiction.
☞
☞
☞
☞
Always install a stop-valve upstream of the appliance.
Downstream of the stop-cock, install appropriate fittings for easy disconnection of the
appliance and filters which can easily be inspected and cleaned.
Use materials, seals and fittings approved according to applicable standards. Use
suitable pipes which have properly treated in order to prevent the release of iron
oxides into the water (as these can alter the taste of the food and mark stainless
steel).
Make sure the water specifications are within the limits indicated in section B.
If necessary, install a suitable water treatment system.
- 2 -
1. INSTALLATION
1.1 Connections
LCE-241M
LCE-241D
LCE-241DP
46.4"
Water inlet
Water drain
Terminal board 3 Ph
Cable gland
Equipotential terminal
Ø
Ø 1"
1.2 Positioning
• leave at least 4" clearance
between the rear of the appliance and the
wall
• leave at least 20" clearance at the
sides of the appliance
The cooling outlets of the control
section of the oven (side panel)
must not be near sources of
hot fumes or steam.
3
/4"
1
/
2
43.3"
15.7"
9.4"
5.7"
2.9"
2"
46.4"
5.1"
14"
59"
22.8"
35"
1.9"
All clearance requirements are the same for combustible or non combustible constructions.
For use only on non combustible foor.
1.3 Specifications (total weight of the appliance is marked on the packaging)
ELECTRICAL RATING
VOLTAGEPOWER RATINGMAX. LOAD (A)
208V 3 Ph 60Hz26.5 kW74 A
240V 3 Ph 60Hz26.5 kW64 A
480V 3 Ph 60Hz26.5 kW33 A
Maximum sound pressure is no higher than 70 dB (A)
- 1 -
1. INSTALLATION
1.4 Installation - procedure
Fit the following units on the top of the
oven:
1) Steam vent pipe
Connecting the water supply
2) Remove the lh side panel by unscrewing the two fixing screws at the bottom (if the optional spray gun is fitted also the relative fixing screws must be
removed).
3) Fit the supplied filters on the water inlet
connections in an accessible position.
21
Spray gun
support
The appliance must be supplied exclusively with
3
cold water conforming to the following specifications:
Pressure:
between 200 and 600 kPa
(30 ÷ 80 PSI);
pH: from 7 to 7.5;
Conductivity: less than 200 µS/cm;
t.d.s. < 100 ppm
Hardness: from 9 to 13°f (= 5÷7 °d = 6,3÷8,8 °e
= 90÷125 ppm)(5 ÷ 10° clark);
Max. salinity and ion content in mg/l:
- chlorides < 30; sulphates < 40; Fe (iron) < 0.1; Cu
(copper) < 0.05; Mn (manganese) < 0.05.
The internal pressure gauge must show a pressure of
100 kPa (15 PSI); if it shows a different value,
adjust to the correct pressure by means of the
pressure regulator screw.
Pressure
gauges
Water
pressure
regulator
screws
3/4"
min. Ø 1"
min. 5% (3°)
max. 5 ft
1/2
1-1
min. Ø 1"
Water drain
WARNING: to ensure the
appliance operates
correctly and to avoid the
risk of serious damage,
the drain must be vented
(i.e. in communication with
the atmosphere).
The material of the
drainage pipe must be
1/2
heat resistant type and not
flexible.
1. INSTALLATION
1.5 Electrical connection
Equipotential connection
• The equipotential terminal ( ) is located
beneath the appliance at the rear lh corner.
Mains connection
• Remove the lh side panel as indicated in
heading 1.4.
• Read the general precautionary notes in
Chapter 4, Section A. of this
handbook.
• Fit the suitable cable gland in the relative
hole.
• Route the cable from the main power
switch through the cable gland, and connect the wires to the terminal board (see
electrical diagram on next page).
terminal board
cable gland
N.B.: After making the connection ensure that the motor
turns in the direction indicated by the arrow on the fan
shroud (in the oven chamber).
1-2
1.5.1 Wiring diagram
1. INSTALLATION
1-3
SAFETY
THERMOSTAT
WATER DRAIN
SOLENOID VALVE
WATER INLET
SOLENOID VALVE
-Y1
-Y2
48
3a3
-Q3
P3
14
EV.S
EV.S
EV.C
EV.C
39
38
-K1
MOTOR
CONTACTOR
24
U1 V1 W1
-M1
FAN
MOTOR
-Q1-Q2
A2
A1
PE
M
3~
U2 V2 W2
56 57 5859 60 61
97
6
969598
12345
44
-K2-K3
22
SLOW
12345621
SPEED
2828
7
8
9
53
62
A2
A1
6
12345
12345621
969598
22
90
89
91
PE
97
FAST
SPEED
28
40
25
26
27
83 84 85
3736
A2
A1
-R2
49 50 51
22
12345621
3333
90
89
91
MICRO-SWITCH
PE
35
31
30
29
86 87 88
21436
80 81 82
21436
5
5
-R1
-K5
A1
SAFETY
CONTACTOR
A2
34
-K4
A2
A1
H. ELEMENT
CONTACTOR
DOOR
42
-K8
1
76
U1 U2
PE
LC FILTER
L1L2
12
-N2
16 15
68
F3
LN
64 6545 46 32 52 23 22 21 47 19 18
R3
STB CHAMBER
DOOR SWITCH
R2
F2
R1
F1
R4
R7
R5
1234567891011121314151617
-N1
ELECTRONIC BOARD
DRAIN
CHAMBER
PROBE
PROBE
18 19 20 21 22 2324 25 26
11
43
75
CORE
PROBE
WATER INLET
PRESSURE SWITCH
27 28 29 30
41 63 55 54
PC
DRAIN
PRESSURE
C
SWITCH
PS
-K7-K6
C
42
-E2
66
74
737271
4
PE
PEPE
1
-H2-H1-H3
2
65
LAMPLAMPLAMP
3
-E1
ELECTRIC CABINET
F1 1A
F2 1A
FUSE HOLDER
F3 20A
F4 20A
F5 20A
77 78 79
95
-X1
L1
L2
L3
PE
POWER SUPPLY
TERMINAL BOARD
LCE-241D & -DP 208/240V 3Ph
-E3-E4
ELECTRIC CABINET
PANEL SX