IMPORTANT READ FIRST IMPORTANT
CAUTION: EACH UNIT IS EXTREMLY HEAVY. FOR SAFE
HANDLING, INSTALLER SHOULD OBTAIN HELP AS
NEEDED, OR EMPLOY APPROPRIATE MATERIALS
HANDLING EQUIPMENT (SUCH AS A FORKLIFT, DOLLY,
OR PALLET JACK) TO REMOVE THE UNIT FROM THE
SKID AND MOVE IT TO THE PLACE OF INSTALLATION.
CAUTION: ANY STAND, COUNTER OR OTHER DEVICE ON WHICH
GRIDDLE WILL BE LOCATED MUST BE DESIGNED TO
SUPPORT THE WEIGHT OF THE GRIDDLE.
CAUTION: SHIPPING STRAPS ARE UNDER TENSION AND CAN
SNAP BACK WHEN CUT.
DANGER: THIS APPLIANCE MUST BE GROUNDED AT THE
TERMINAL PROVIDED. FAILURE TO GROUND THE
APPLIANCE COULD RESULT IN ELECTROCUTION AND
DEATH.
WARNING: INSTALLATION OF THE UNIT MUST BE DONE BY
PERSONNEL QUALIFIED TO WORK WITH ELECTRICITY
AND PLUMBING. IMPROPER INSTALLATION CAN
CAUSE INJURY TO PERSONNEL AND/OR DAMAGE TO
EQUIPMENT. UNIT MUST BE INSTALLED IN
ACCORDANCE WITH ALL APPLICABLE CODES.
NOTICE: The data plate is located behind access panel between
controls and grease drawer. The grill voltage, wattage,
serial number, wire size, and clearance specifications are
on the data plate. This information should be carefully
read and understood before proceeding with the
installation.
NOTICE: The installation of any components such as a vent hood,
grease extractors, fire extinguisher systems, must
conform to their applicable National, State and locally
recognized installation standards.
NOTICE: During the first few hours of operation you may notice a
small amount of smoke coming off the grill, and a faint
odor from the smoke. This is normal for a new grill and
will disappear after the first few hours of use.
CAUTION: ALWAYS KEEP THE AREA NEAR THE APPLIANCE FREE
FROM COMBUSTIBLE MATERIALS.
CAUTION: KEEP FLOOR IN FRONT OF EQUIPMENT CLEAN AND
DRY. IF SPILLS OCCUR, CLEAN IMMEDIATELY, TO
AVOID THE DANGER OF SLIPS OR FALLS.
2
IMPORTANT READ FIRST IMPORTANT
WARNING:KEEP WATER AND SOLUTIONS OUT OF CONTROLS.
NEVER SPRAY OR HOSE CONTROL CONSOLE,
ELECTRICAL CONNECTIONS, ETC.
CAUTION:MOST CLEANERS ARE HARMFUL TO THE SKIN, EYES,
MUCOUS MEMBRANES AND CLOTHING.
PRECAUTIONS SHOULD BE TAKEN TO WEAR RUBBER
GLOVES, GOGGLES OR FACE SHIELD AND
PROTECTIVE CLOTHING. CAREFULLY READ THE
WARNING AND FOLLOW THE DIRECTIONS ON THE
LABEL OF THE CLEANER TO BE USED.
NOTICE:Service on this, or any other, LANG appliance must be
performed by qualified personnel only. Consult your
authorized service station directory or call the factory at
1-800-224-LANG (5264), or WWW.LANGWORLD.COM for
the service station nearest you.
WARNING:BOTH HIGH AND LOW VOLTAGES ARE PRESENT
INSIDE THIS APPLIANCE WHEN THE UNIT IS
PLUGGED/WIRED INTO A LIVE RECEPTACLE. BEFORE
REPLACING ANY PARTS, DISCONNECT THE UNIT
FROM THE ELECTRIC POWER SUPPLY.
CAUTION:USE OF ANY REPLACEMENT PARTS OTHER THAN
THOSE SUPPLIED BY LANG OR THEIR AUTHORIZED
DISTRIBUTORS CAN CAUSE BODILY INJURY TO THE
OPERATOR AND DAMAGE TO THE EQUIPMENT AND
WILL VOID ALL WARRANTIES.
3
EQUIPMENT DESCRIPTION
ELECTRIC GRIDDLE
EXTERIOR
♦ Griddle
The griddle dimensions are 17” (43.18cm) High, 30” (76.20cm) Deep, and width is dependent on
the actual model number.
The Sides, Bottom, and Rear wall are constructed of double wall stainless steel, which allows
closer installation to combustible surfaces.
The griddle surface is made of 1” thick, highly polished steel to reduce hot and cold spots, recovery
problems, warping, and ensure even heat to the edges of the griddle.
♦ XL Hood
The Hood dimension (including griddle) are 22¼” (55.88cm) High with hood down, 44¾”
(113.67cm) High with hood up, 31½” (80cm) Deep, and 24” (61cm) Wide.
The Hood wrap is constructed of stainless steel and uses infrared heat to broil the product.
♦ Pane Bella
The Pane Bella dimensions are 12” (30.5cm) High with hood down, 24.5” (62.25cm) with hood up,
16” (40.5 cm) Deep and width is dependent on model number.
CONTROLS
The Electric Griddle is available either with the Lang Accu-Temp (LG-24, 36, 48, 60, 72) controls or the
Lang Selectronic (LG-24S, 36S, 48S, 60S, 72S):
♦ LG (ACCU-TEMP)
Each twelve-inch section has its own easy to use manual thermostat with a temperature range from
175°F to 450°F in 50° increments.
Each twelve-inch section has a set of 6 K.W. elements for high efficiency, quick recovery and
outstanding performance.
♦ LGS (SELECTRONIC)
Each twelve-inch section has its own temperature selector switch that snaps into place to lock in
any temperature from 175°F to 450°F in 25° increments.
Each twelve-inch section of the griddle is controlled by an area sensitive RTD probe, which can
sense and react to a temperature change of +/- 4°F.
Each twelve-inch section has a set of 6 K.W. elements for high efficiency, quick recovery and
outstanding performance.
♦ Pane Bella
Each twelve-inch section has its own easy to use manual thermostat with a knob.
Each 12” section has its own 900 Watt element in the bottom and 720 Watt in the top.
4
INSTALLATION
RECEIVING THE GRIDDLE
Upon receipt, check for freight damage, both visible and concealed. Visible damage should be noted on the freight
bill at the time of delivery and signed by the carrier's agent. Concealed loss or damage means loss or damage, which
does not become apparent until the merchandise has been unpacked.
If concealed loss or damage is discovered upon unpacking, make a written request for inspection by the carrier's
agent within 15 days of delivery. All packing material should be kept for inspection.
Do not return damaged merchandise to Lang Manufacturing Company. File your claim with the carrier.
Prior to un-crating, move the range as near its intended location as practical. The crating will help protect the unit
from the physical damage normally associated with moving it through hallways and doorways.
ELECTRICAL CONNECTION
LG / LGS
There is one power supply connection on 2, 3 and 4 foot griddles. There are two power supply connections on 5 and
6-foot griddles. Refer to the power supply chart in the Technical Data portion of this manual, for proper power
supply size.
There is (1) one 1 1/4-inch conduit knockout on 2, 3, and 4-foot griddles located at the rear of the griddle, through
the back and the bottom of the griddle body. There are (2) two 1 1/4-inch conduit knockouts provided on the 5 and 6
foot griddles. Use a supply wire suitable for at least 90 degree centigrade.
The model LG-S griddle is shipped from the factory wired for 208/240 or 480 volts, the 208/240 griddle is a dual
voltage design. Jumper wires on terminal strip next to the main power supply connection determine the griddle
voltage. For a 208 volt power supply, leave the jumpers in place. For a 240 volt power supply disconnect the
jumpers as indicated on the tag to the terminal strip. The 480 volt griddle can be operated on 480 volts only.
PB
All PB-24 grills are supplied with a 48” 10 gauge cord and a NEMA L6-30P plug.
The PB-12 grill is supplied with a 48” 12 gauge cord and a NEMA L6-30P plug on the 240 Volt and NEMA 5-15P
plug on the 120 Volt
XL HOOD
Power connection can be made at a two pole terminal block located next to the power connection on the grill.
All XL Hoods are single phase and come in either 208 Volt or 240 Volt.
5
PHASING
INSTALLATION CONT’D
LG / LGS
All griddles are shipped from the factory set up for a three- phase service. Rearrange the wires in the power supply
terminal block to convert the griddle to single phase. Rephasing the griddle is not chargeable to Lang Manufacturing
Company as warranty. To convert to single phase follow the chart below.
2) Incoming Volt - Single Phase L1-L2______
Three Phase L1-L2______ L2-L3______ L3-L1______
3) Amp draw L1______
L2______
L3______
6) Verify actual temperature at 350 °F ________ °F.
Note: Install thermocouple wire in center of 12 section for that control area.
Let griddle cycle off and on 3 times before recording temperature.
Model #_______ Date_______ Serial #________
Store #___________ Tech Name___________________
Contact_______________ Company _________________________
Store Phone #___________ Service Company Phone #______________
The suggested time and temperature chart (below) is provided as a guide for the products
listed only.
CAUTION:ALWAYS KEEP THE AREA NEAR THE APPLIANCE FREE
FROM COMBUSTIBLE MATERIALS.
CAUTION:KEEP FLOOR IN FRONT OF EQUIPMENT CLEAN AND
DRY. IF SPILLS OCCUR, CLEAN IMMEDIATELY, TO
AVOID THE DANGER OF SLIPS OR FALLS.
SUGGESTED TIMES AND TEMPERATURES
PRODUCTS
HAMBURGER
2 patties per LB 3506 to 8
4 patties per LB 3504 to 6
6 patties per LB 3503 to 4
STEAKS
1/2 to 3/4 inch thick, cooked medium3755 to 7
3/4 to 1 inch thick, cooked medium3758 to 10
Lamb Chops 3506 to 8
Pork Chops 3506 to 8
TEMPERATURE
350
TIME (MIN)
Salmon 3506 to 8
Halibut 3256 to 8
Snapper 3256 to 8
Hashbrown Potatoes3753 to 4
Bacon 3503 to 4
Sausage Links or Patties3503 to 4
Ham (Pre-cooked
Eggs 2752 to 4
Note: The times and temperatures in this chart are intended as a general guide and starting
point. Your actual times and temperatures may vary from this chart.
If different temperature settings are to be used, select one side of the griddle and
operate at the lowest temperature. Adjoining sections should be set at
progressively higher temperatures. Do not try to operate the end sections hot and
the center sections cool.
8